Juniper Networks, the Juniper Networks logo, NetScreen, and ScreenOS are registered trademarks of Juniper Networks, Inc. in the United States and
other countries. All other trademarks, service marks, registered trademarks, or registered service marks in this document are the property of Juniper
Networks or their respective owners. All specifications are subject to change without notice. Juniper Networks assumes no responsibility for any
inaccuracies in this document or for any obligation to update information in this document. Juniper Networks reserves the right to change, modify,
transfer, or otherwise revise this publication without notice.
FCC Statement
The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. The equipment generates, uses, and can radiate radio-frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.
The following information is for FCC compliance of Class B devices: The equipment described in this manual generates and may radiate radio-frequency
energy. If it is not installed in accordance with Juniper Networks’ installation instructions, it may cause interference with radio and television reception.
This equipment has been tested and found to comply with the limits for a Class B digital device in accordance with the specifications in part 15 of the FCC
rules. These specifications are designed to provide reasonable protection against such interference in a residential installation. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Consult the dealer or an experienced radio/TV technician for help.
Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
Caution: Changes or modifications to this product could void the user's warranty and authority to operate this device.
Disclaimer
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED
WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED
WARRANTY, CONTACT YOUR JUNIPER NETWORKS REPRESENTATIVE FOR A COPY.
Table of Contents
About This Guidexi
Audience......................................................................................................... xi
Conventions.................................................................................................... xi
Documentation .............................................................................................. xii
Web Access for Documentation............................................................... xii
Requesting Technical Support ........................................................................ xii
Self-Help Online Tools and Resources..................................................... xiii
This guide describes the physical features of Juniper Networks Intrusion Detection
and Prevention (IDP) solution: the IDP 75, IDP 250, IDP 800, and IDP 8200
sensors. It also explains how to install, configure, update/reimage, and service the
IDP system.
This preface has the following sections:
Audience on page xi
Conventions on page xi
Documentation on page xii
Requesting Technical Support on page xii
Audience
This guide is intended for experienced system and network specialists.
Conventions
The term sensor is used to denote an IDP 75, 250, 800, or 8200 appliance.
Table 1 defines notice icons used in this guide.
Table 1: Notice Icons
IconMeaningDescription
Informational noteIndicates important features or instructions.
CautionIndicates that you may risk losing data or damaging your
hardware.
WarningAlerts you to the risk of personal injury.
Audience xi
IDP 75, 250, 800, and 8200 Installation Guide
Documentation
This guide is shipped in the box with all new IDP sensors. It provides the basic
procedures for getting your IDP system running.
With each major software release, Juniper Networks provides the IDP
Documentation CD. The CD contains the documentation set in PDF format.
The IDP documentation set includes the following books:
Release Notes—Contain the latest information about features, changes, known
problems and resolved problems. If the information in the Release Notes differs
from the information found in the documentation set, follow the Release Notes.
Intrusion Detection and Prevention Concepts & Examples Guide—Explains
basic concepts of the IDP system and provides examples of how to use the
system.
IDP 75, 250, 800, and 8200 Installation Guide (this manual)—Describes the
hardware components of the IDP 75, 250, 800, and 8200 sensors. Provides
instructions for rack-mounting, cabling, basic configuration, management
server installation, and user interface installation.
Online Help—Available through the IDP Appliance Configuration Manager
(ACM). The online help provides explanations for sensor configuration options
as well as step-by-step directions for performing common tasks.
Technical product support is available through the Juniper Networks Technical
Assistance Center (JTAC). If you are a customer with an active J-Care or JNASC
support contract, or are covered under warranty, and need post sales technical
support, you can access our tools and resources online or open a case with JTAC.
JTAC policies—For a complete understanding of our JTAC procedures and
JTAC hours of operation—The JTAC centers have resources available 24 hours a
day, 7 days a week, 365 days a year.
Self-Help Online Tools and Resources
For quick and easy problem resolution, Juniper Networks has designed an online
self-service portal called the Customer Support Center (CSC) that provides you with
the following features:
This chapter provides an overview of IDP configuration options. This chapter has
the following sections:
Installation Roadmap on page 1
IDP Configuration Basics on page 2
Installation Roadmap
This section provides a high-level roadmap of an IDP sensor installation. With each
step is a reference to more information.
1. Install the NetScreen-Security Manager (NSM) server onto a dedicated host or
hosts. See the NetScreen-Security Manager Installation Guide for installation
instructions.
2. Install the NSM GUI on a Windows or Linux client machine. See the
NetScreen-Security Manager Installation Guide for installation instructions.
3. Decide on a place in your network for the sensor. Choose which mode you will
run. See Chapter 4, “Installing the Sensor,” on page 17.
4. Install the sensor on a rack. See Chapter 4, “Installing the Sensor,” on page 17.
5. Log into the sensor using the console port to run the EasyConfig script. This
script lets you specify a sensor mode, IP address, netmask, default gateway,
and date or time. See “Using the Console Serial Port to Configure the Sensor”
on page 22. You can use the default login name (root) and password (abc123)
for the sensor.
6. (Optional) If you want to change your default login and password, change port
speeds, or do more advanced configuration of the sensor, use a Web browser
to log into the sensor’s Appliance Configuration Manager (ACM). You can reach
it by typing
browser.
7. Start the NSM GUI. The default login ID is super. Use the password you
specified when you installed the NSM server.
https://SensorIPAddress in the Address or Location box of your
Installation Roadmap 1
IDP 75, 250, 800, and 8200 Installation Guide
8. Add the sensor as an object in NSM using the Add Device wizard. Select Device
Manager > Security Devices from the left navigational pane, and then click
the + button. See “Adding Your Sensor to NSM” on page 29. The Add Device
Wizard creates a database entry in NSM for the sensor, imports the sensor’s
configuration, and loads the Juniper Networks Recommended policy onto the
sensor. At that point, your sensor is actively protecting your network.
To improve the performance and accuracy of your protection, use the IDP Concepts & Examples Guide and the NetScreen-Security Manager Administrator’s Guide to tailor
your security policy to your network.
NOTE: You must update your attack objects to get the latest protection.
IDP Configuration Basics
This section provides an introduction to IDP configuration basics. An IDP
configuration consists of the following components:
IDP sensor placement—Decide where to position the sensor in the network.
IDP sensor placement mode—Decide to use passive or active mode when
deploying your IDP sensor.
NetScreen-Security Manager—Use NetScreen-Security Manager (NSM) to
administer the sensor.
IDP Sensor Placement
Juniper Networks IDP sensor is an ideal solution to be implemented inline between
gateway firewalls and DMZ or internal networks. IDP sensor placement is an
important part of the installation.
You should choose a location for your IDP sensor based on your existing network
hardware and the networks you want to protect. The examples provided in this
guide place the IDP sensor behind the firewall or router.
IDP Sensor Deployment Mode
IDP sensors can be installed individually or in high availability (HA) clusters of two
or more.
2 IDP Configuration Basics
For configurations without high availability, you can deploy the IDP sensor as a
passive sniffer or as an active gateway.
Passive Mode—The sniffer mode is passive. In sniffer mode, the IDP is not
directly involved with packet flow. While it can send resets, protection is not
guaranteed as attacks may have already happened before the reset can be
acted upon. In addition, attacker machines may ignore resets.
Chapter 1: Planning an Installation
To use an IDP sensor as a passive intrusion detection system without
prevention capabilities, deploy the sensor in passive sniffer mode to monitor
and log network traffic. If the sensor is attached to a network switch, you must
configure the switch to mirror all traffic to that port. The IDP sensor defaults to
sniffer mode.
Active mode—The gateway (inline) mode is active. This mode takes full
advantage of IDP attack prevention capabilities and multimethod detection
mechanisms.
With inline modes, the sensor is directly involved in the packet flow. The
sensor can stop attacks by dropping malicious packets before they reach their
target.
Inline sensors are typically configured in transparent mode. For other inline
modes, see “Advanced Configuration” on page 43.
NOTE: For IDP 8200 Release 4.2, only transparent mode is available.
One step in setting up IDP on your network is to decide on a deployment mode.
Figure 1 and Figure 2 illustrate the possible deployment modes and their primary
advantages and disadvantages.
Figure 1: Sniffer Mode (Passive)
Internet
Hub or
eth2
Switch
Management
Server
IP 2.2.2.4
User Interface
IP 2.2.2.5
Firewall
Hub or
Switch
IP 1.1.1.1
IP 2.2.2.1
Mirror or SPAN port, if a switch
straight-through cable
IDP Sensor
MGT
port
eth0 IP 2.2.2.7
Server1
IP 1.1.1.2
GW 1.1.1.1
Server2
IP 1.1.1.3
GW 1.1.1.1
Protected Machines
Server3
IP 1.1.1.4
GW 1.1.1.1
Table 2 lists the advantages and the disadvantages of using the sensor in passive
sniffer mode.
IDP Configuration Basics 3
IDP 75, 250, 800, and 8200 Installation Guide
Management Server
IP 2.2.2.4
User Interface
IP 2.2.2.5
Protected Machines
Hub or
Switch
Firewall
eth2
No ip address
Forwarding Interface
Server1
IP 1.1.1.2
GW 1.1.1.1
Server2
IP 1.1.1.3
GW 1.1.1.1
Server3
IP 1.1.1.4
GW 1.1.1.1
IP 2.2.2.1
IP 1.1.1.1
IDP Sensor
Hub or
Switch
eth3
No IP address
Forwarding Interface
eth0 IP 2.2.2.7 MGT
Interface
Internet
Table 2: Advantages and Disadvantages of Sniffer Mode (Passive)
AdvantagesDisadvantages
Seamlessly replaces the current intrusion
detection
Causes minimal network changes
Does not create an additional
point-of-failure gateway
Monitors and logs suspicious network
activity
Figure 2: Transparent Mode (Inline Active)
Passively monitors with limited prevention
only
Requires a hub or the Switched Port Analyser
(SPAN) port of a switch
4 IDP Configuration Basics
Table 3 lists the advantages and the disadvantages of using the sensor in active
transparent (inline) mode.
Table 3: Advantages and Disadvantages of Transparent Mode (Inline Active)
AdvantagesDisadvantages
Reliably responds to and prevents attacks
Simple, transparent deployment
Allows Layer 2 broadcasts
No changes to routing tables or network
equipment
Forwards non-IP traffic
NetScreen-Security Manager
Use NetScreen-Security Manager to administer the sensor. See the
NetScreen-Security Manager Administrator’s Guide to tailor your security policy to
your network. See the IDP Concepts & Examples Guide to improve the performance
and accuracy of your protection.
Chapter 1: Planning an Installation
Cannot connect IP networks with different
address spaces
IDP Configuration Basics 5
IDP 75, 250, 800, and 8200 Installation Guide
6 IDP Configuration Basics
Chapter 2
Hardware Overview
This chapter provides detailed descriptions of the Juniper Networks IDP sensors
and their components.
This chapter has the following sections:
IDP Sensors on page 7
Traffic Ports (Forwarding Interfaces) on page 10
Management Ports on page 13
Hard Drives and USB Ports on page 13
Power Supplies on page 13
IDP Sensor LEDs on page 14
IDP Sensors
This section provides an overview of the following IDP sensors:
IDP 75 Sensor on page 8
IDP 250 Sensor on page 8
IDP 800 Sensor on page 8
IDP 8200 Sensor on page 9
Each sensor contains a USB port you can use for reimaging the sensors.
CAUTION: Both the console serial port and the management network interface
port use the same RJ-45 connector. Do not plug a network cable into the console
serial port.
IDP Sensors 7
Loading...
+ 47 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.