Juniper Networks EX4200, EX3200 User Manual

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches
Juniper Networks, Inc.
1194 North Mathilda Avenue
Sunnyvale, California 94089
USA
408-745-2000
www.juniper.net
This product includes the Envoy SNMP Engine, developed by Epilogue Technology, an Integrated Systems Company. Copyright © 1986-1997, Epilogue Technology Corporation. All rights reserved. This program and its documentation were developed at private expense, and no part of them is in the public domain.
This product includes memory allocation software developed by Mark Moraes, copyright © 1988, 1989, 1993, University of Toronto.
This product includes FreeBSD software developed by the University of California, Berkeley, and its contributors. All of the documentation and software included in the 4.4BSD and 4.4BSD-Lite Releases is copyrighted by the Regents of the University of California. Copyright © 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994. The Regents of the University of California. All rights reserved.
GateD software copyright © 1995, the Regents of the University. All rights reserved. Gate Daemon was originated and developed through release 3.0 by Cornell University and its collaborators. Gated is based on Kirtons EGP, UC Berkeleys routing daemon (routed), and DCNs HELLO routing protocol. Development of Gated has been supported in part by the National Science Foundation. Portions of the GateD software copyright © 1988, Regents of the University of California. All rights reserved. Portions of the GateD software copyright © 1991, D. L. S. Associates.
This product includes software developed by Maker Communications, Inc., copyright © 1996, 1997, Maker Communications, Inc.
Juniper Networks, the Juniper Networks logo, JUNOS, NetScreen, ScreenOS, and Steel-Belted Radius are registered trademarks of Juniper Networks, Inc. in the United States and other countries. JUNOSe is a trademark of Juniper Networks, Inc. All other trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners.
Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice.
Products made or sold by Juniper Networks or components thereof might be covered by one or more of the following patents that are owned by or licensed to Juniper Networks: U.S. Patent Nos. 5,473,599, 5,905,725, 5,909,440, 6,192,051, 6,333,650, 6,359,479, 6,406,312, 6,429,706, 6,459,579, 6,493,347, 6,538,518, 6,538,899, 6,552,918, 6,567,902, 6,578,186, and 6,590,785.
EX3200 and EX4200 Ethernet Switches Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches
Copyright © 2010, Juniper Networks, Inc. All rights reserved. Printed in USA.
Writing: Appumon Joseph, Aviva Garrett, Greg Houde, Hemraj Rao S, Hareesh Kumar K N, Keldyn West, Shikha Kalra, Steve Levine Editing: Cindy Martin, Rajan V K Illustration: Faith Bradford Brown Cover Design:
Revision History 15 March 2008Revision 1 28 April 2008Revision 2 12 August 2008Revision 3 30 January 2009Revision 4 14 April 2009Revision 5 20 July 2009Revision 6 4 November 2009Revision 7 18 December 2009Revision 8 17 February 2010Revision 9
The information in this document is current as of the date listed in the revision history.
YEAR 2000 NOTICE
Juniper Networks hardware and software products are Year 2000 compliant. The JUNOS Software has no known time-related limitations through the year
2038. However, the NTP application is known to have some difficulty in the year 2036.
SOFTWARE LICENSE
The terms and conditions for using this software are described in the software license contained in the acknowledgment to your purchase order or, to the extent applicable, to any reseller agreement or end-user purchase agreement executed between you and Juniper Networks. By using this software, you indicate that you understand and agree to be bound by those terms and conditions.
Generally speaking, the software license restricts the manner in which you are permitted to use the software and may contain prohibitions against certain uses. The software license may state conditions under which the license is automatically terminated. You should consult the license for further details.
For complete product documentation, please see the Juniper Networks Web site at www.juniper.net/techpubs.
ii
END USER LICENSE AGREEMENT
READ THIS END USER LICENSE AGREEMENT (AGREEMENT) BEFORE DOWNLOADING, INSTALLING, OR USING THE SOFTWARE. BY DOWNLOADING, INSTALLING, OR USING THE SOFTWARE OR OTHERWISE EXPRESSING YOUR AGREEMENT TO THE TERMS CONTAINED HEREIN, YOU (AS CUSTOMER OR IF YOU ARE NOT THE CUSTOMER, AS A REPRESENTATIVE/AGENT AUTHORIZED TO BIND THE CUSTOMER) CONSENT TO BE BOUND BY THIS AGREEMENT. IF YOU DO NOT OR CANNOT AGREE TO THE TERMS CONTAINED HEREIN, THEN (A) DO NOT DOWNLOAD, INSTALL, OR USE THE SOFTWARE, AND (B) YOU MAY CONTACT JUNIPER NETWORKS REGARDING LICENSE TERMS.
1. The Parties. The parties to this Agreement are (i) Juniper Networks, Inc. (if the Customers principal office is located in the Americas) or Juniper Networks (Cayman) Limited (if the Customers principal office is located outside the Americas) (such applicable entity being referred to herein as Juniper), and (ii) the person or organization that originally purchased from Juniper or an authorized Juniper reseller the applicable license(s) for use of the Software (Customer) (collectively, the Parties).
2. The Software. In this Agreement, Software means the program modules and features of the Juniper or Juniper-supplied software, for which Customer has paid the applicable license or support fees to Juniper or an authorized Juniper reseller, or which was embedded by Juniper in equipment which Customer purchased from Juniper or an authorized Juniper reseller. Software also includes updates, upgrades and new releases of such software. Embedded Software means Software which Juniper has embedded in or loaded onto the Juniper equipment and any updates, upgrades, additions or replacements which are subsequently embedded in or loaded onto the equipment.
3. License Grant. Subject to payment of the applicable fees and the limitations and restrictions set forth herein, Juniper grants to Customer a non-exclusive and non-transferable license, without right to sublicense, to use the Software, in executable form only, subject to the following use restrictions:
a. Customer shall use Embedded Software solely as embedded in, and for execution on, Juniper equipment originally purchased by Customer from Juniper or an authorized Juniper reseller.
b. Customer shall use the Software on a single hardware chassis having a single processing unit, or as many chassis or processing units for which Customer has paid the applicable license fees; provided, however, with respect to the Steel-Belted Radius or Odyssey Access Client software only, Customer shall use such Software on a single computer containing a single physical random access memory space and containing any number of processors. Use of the Steel-Belted Radius or IMS AAA software on multiple computers or virtual machines (e.g., Solaris zones) requires multiple licenses, regardless of whether such computers or virtualizations are physically contained on a single chassis.
c. Product purchase documents, paper or electronic user documentation, and/or the particular licenses purchased by Customer may specify limits to Customers use of the Software. Such limits may restrict use to a maximum number of seats, registered endpoints, concurrent users, sessions, calls, connections, subscribers, clusters, nodes, realms, devices, links, ports or transactions, or require the purchase of separate licenses to use particular features, functionalities, services, applications, operations, or capabilities, or provide throughput, performance, configuration, bandwidth, interface, processing, temporal, or geographical limits. In addition, such limits may restrict the use of the Software to managing certain kinds of networks or require the Software to be used only in conjunction with other specific Software. Customers use of the Software shall be subject to all such limitations and purchase of all applicable licenses.
d. For any trial copy of the Software, Customers right to use the Software expires 30 days after download, installation or use of the Software. Customer may operate the Software after the 30-day trial period only if Customer pays for a license to do so. Customer may not extend or create an additional trial period by re-installing the Software after the 30-day trial period.
e. The Global Enterprise Edition of the Steel-Belted Radius software may be used by Customer only to manage access to Customers enterprise network. Specifically, service provider customers are expressly prohibited from using the Global Enterprise Edition of the Steel-Belted Radius software to support any commercial network access services.
The foregoing license is not transferable or assignable by Customer. No license is granted herein to any user who did not originally purchase the applicable license(s) for the Software from Juniper or an authorized Juniper reseller.
4. Use Prohibitions. Notwithstanding the foregoing, the license provided herein does not permit the Customer to, and Customer agrees not to and shall not: (a) modify, unbundle, reverse engineer, or create derivative works based on the Software; (b) make unauthorized copies of the Software (except as necessary for backup purposes); (c) rent, sell, transfer, or grant any rights in and to any copy of the Software, in any form, to any third party; (d) remove any proprietary notices, labels, or marks on or in any copy of the Software or any product in which the Software is embedded; (e) distribute any copy of the Software to any third party, including as may be embedded in Juniper equipment sold in the secondhand market; (f) use any locked or key-restricted feature, function, service, application, operation, or capability without first purchasing the applicable license(s) and obtaining a valid key from Juniper, even if such feature, function, service, application, operation, or capability is enabled without a key; (g) distribute any key for the Software provided by Juniper to any third party; (h) use the Software in any manner that extends or is broader than the uses purchased by Customer from Juniper or an authorized Juniper reseller; (i) use Embedded Software on non-Juniper equipment; (j) use Embedded Software (or make it available for use) on Juniper equipment that the Customer did not originally purchase from Juniper or an authorized Juniper reseller; (k) disclose the results of testing or benchmarking of the Software to any third party without the prior written consent of Juniper; or (l) use the Software in any manner other than as expressly provided herein.
5. Audit. Customer shall maintain accurate records as necessary to verify compliance with this Agreement. Upon request by Juniper, Customer shall furnish such records to Juniper and certify its compliance with this Agreement.
iii
6. Confidentiality. The Parties agree that aspects of the Software and associated documentation are the confidential property of Juniper. As such, Customer shall exercise all reasonable commercial efforts to maintain the Software and associated documentation in confidence, which at a minimum includes restricting access to the Software to Customer employees and contractors having a need to use the Software for Customers internal business purposes.
7. Ownership. Juniper and Junipers licensors, respectively, retain ownership of all right, title, and interest (including copyright) in and to the Software, associated documentation, and all copies of the Software. Nothing in this Agreement constitutes a transfer or conveyance of any right, title, or interest in the Software or associated documentation, or a sale of the Software, associated documentation, or copies of the Software.
8. Warranty, Limitation of Liability, Disclaimer of Warranty. The warranty applicable to the Software shall be as set forth in the warranty statement that accompanies the Software (the Warranty Statement). Nothing in this Agreement shall give rise to any obligation to support the Software. Support services may be purchased separately. Any such support shall be governed by a separate, written support services agreement. TO THE MAXIMUM EXTENT PERMITTED BY LAW, JUNIPER SHALL NOT BE LIABLE FOR ANY LOST PROFITS, LOSS OF DATA, OR COSTS OR PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES, OR FOR ANY SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THIS AGREEMENT, THE SOFTWARE, OR ANY JUNIPER OR JUNIPER-SUPPLIED SOFTWARE. IN NO EVENT SHALL JUNIPER BE LIABLE FOR DAMAGES ARISING FROM UNAUTHORIZED OR IMPROPER USE OF ANY JUNIPER OR JUNIPER-SUPPLIED SOFTWARE. EXCEPT AS EXPRESSLY PROVIDED IN THE WARRANTY STATEMENT TO THE EXTENT PERMITTED BY LAW, JUNIPER DISCLAIMS ANY AND ALL WARRANTIES IN AND TO THE SOFTWARE (WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE), INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NONINFRINGEMENT. IN NO EVENT DOES JUNIPER WARRANT THAT THE SOFTWARE, OR ANY EQUIPMENT OR NETWORK RUNNING THE SOFTWARE, WILL OPERATE WITHOUT ERROR OR INTERRUPTION, OR WILL BE FREE OF VULNERABILITY TO INTRUSION OR ATTACK. In no event shall Junipers or its suppliers or licensors liability to Customer, whether in contract, tort (including negligence), breach of warranty, or otherwise, exceed the price paid by Customer for the Software that gave rise to the claim, or if the Software is embedded in another Juniper product, the price paid by Customer for such other product. Customer acknowledges and agrees that Juniper has set its prices and entered into this Agreement in reliance upon the disclaimers of warranty and the limitations of liability set forth herein, that the same reflect an allocation of risk between the Parties (including the risk that a contract remedy may fail of its essential purpose and cause consequential loss), and that the same form an essential basis of the bargain between the Parties.
9. Termination. Any breach of this Agreement or failure by Customer to pay any applicable fees due shall result in automatic termination of the license granted herein. Upon such termination, Customer shall destroy or return to Juniper all copies of the Software and related documentation in Customers possession or control.
10. Taxes. All license fees payable under this agreement are exclusive of tax. Customer shall be responsible for paying Taxes arising from the purchase of the license, or importation or use of the Software. If applicable, valid exemption documentation for each taxing jurisdiction shall be provided to Juniper prior to invoicing, and Customer shall promptly notify Juniper if their exemption is revoked or modified. All payments made by Customer shall be net of any applicable withholding tax. Customer will provide reasonable assistance to Juniper in connection with such withholding taxes by promptly: providing Juniper with valid tax receipts and other required documentation showing Customers payment of any withholding taxes; completing appropriate applications that would reduce the amount of withholding tax to be paid; and notifying and assisting Juniper in any audit or tax proceeding related to transactions hereunder. Customer shall comply with all applicable tax laws and regulations, and Customer will promptly pay or reimburse Juniper for all costs and damages related to any liability incurred by Juniper as a result of Customers non-compliance or delay with its responsibilities herein. Customers obligations under this Section shall survive termination or expiration of this Agreement.
11. Export. Customer agrees to comply with all applicable export laws and restrictions and regulations of any United States and any applicable foreign agency or authority, and not to export or re-export the Software or any direct product thereof in violation of any such restrictions, laws or regulations, or without all necessary approvals. Customer shall be liable for any such violations. The version of the Software supplied to Customer may contain encryption or other capabilities restricting Customers ability to export the Software without an export license.
12. Commercial Computer Software. The Software is commercial computer software and is provided with restricted rights. Use, duplication, or disclosure by the United States government is subject to restrictions set forth in this Agreement and as provided in DFARS 227.7201 through 227.7202-4, FAR 12.212, FAR 27.405(b)(2), FAR 52.227-19, or FAR 52.227-14(ALT III) as applicable.
13. Interface Information. To the extent required by applicable law, and at Customer's written request, Juniper shall provide Customer with the interface information needed to achieve interoperability between the Software and another independently created program, on payment of applicable fee, if any. Customer shall observe strict obligations of confidentiality with respect to such information and shall use such information in compliance with any applicable terms and conditions upon which Juniper makes such information available.
14. Third Party Software. Any licensor of Juniper whose software is embedded in the Software and any supplier of Juniper whose products or technology are embedded in (or services are accessed by) the Software shall be a third party beneficiary with respect to this Agreement, and such licensor or vendor shall have the right to enforce this Agreement in its own name as if it were Juniper. In addition, certain third party software may be provided with the Software and is subject to the accompanying license(s), if any, of its respective owner(s). To the extent portions of the Software are distributed under and subject to open source licenses obligating Juniper to make the source code for such portions publicly available (such as the GNU General Public License (GPL) or the GNU Library General Public License (LGPL)), Juniper will make such source code portions (including Juniper modifications, as appropriate) available upon request for a period of up to three years from the date of distribution. Such request can be made in writing to Juniper Networks, Inc., 1194
N. Mathilda Ave., Sunnyvale, CA 94089, ATTN: General Counsel. You may obtain a copy of the GPL at http://www.gnu.org/licenses/gpl.html, and a copy of the LGPL at http://www.gnu.org/licenses/lgpl.html.
15. Miscellaneous. This Agreement shall be governed by the laws of the State of California without reference to its conflicts of laws principles. The provisions of the U.N. Convention for the International Sale of Goods shall not apply to this Agreement. For any disputes arising under this Agreement, the Parties hereby consent to the personal and exclusive jurisdiction of, and venue in, the state and federal courts within Santa Clara County, California. This Agreement constitutes the entire and sole agreement between Juniper and the Customer with respect to the Software, and supersedes all prior and contemporaneous
iv
agreements relating to the Software, whether oral or written (including any inconsistent terms contained in a purchase order), except that the terms of a separate written agreement executed by an authorized Juniper representative and Customer shall govern to the extent such terms are inconsistent or conflict with terms contained herein. No modification to this Agreement nor any waiver of any rights hereunder shall be effective unless expressly assented to in writing by the party to be charged. If any portion of this Agreement is held invalid, the Parties agree that such invalidity shall not affect the validity of the remainder of this Agreement. This Agreement and associated documentation has been written in the English language, and the Parties agree that the English version will govern. (For Canada: Les parties aux présentés confirment leur volonté que cette convention de même que tous les documents y compris tout avis qui s'y rattaché, soient redigés en langue anglaise. (Translation: The parties confirm that this Agreement and all related documentation is and will be in the English language)).
v
vi

Table of Contents

About This Topic Collection xxi
How to Use This Guide .................................................................................xxi
List of EX Series Guides for JUNOS Release 10.1 ..........................................xxi
Downloading Software ...............................................................................xxiii
Documentation Symbols Key .....................................................................xxiii
Documentation Feedback ............................................................................xxv
Requesting Technical Support ......................................................................xxv
Self-Help Online Tools and Resources ...................................................xxv
Opening a Case with JTAC ....................................................................xxvi
Part 1 Switch and Components Overview and Specifications
Chapter 1 EX3200 and EX4200 Switches Overview 3
EX3200 and EX4200 Switches Hardware Overview ........................................3
EX3200 and EX4200 Switch Types ...........................................................3
EX3200 Switches ......................................................................................4
EX4200 Switches ......................................................................................4
Uplink Modules .........................................................................................5
Power over Ethernet (PoE) Ports ...............................................................5
EX3200 Switch Models ....................................................................................6
EX4200 Switch Models ....................................................................................6
Chassis Physical Specifications for EX3200 and EX4200 Switches ..................7
Front Panel of an EX3200 Switch ....................................................................8
Rear Panel of an EX3200 Switch .....................................................................9
Front Panel of an EX4200 Switch ..................................................................10
Rear Panel of an EX4200 Switch ...................................................................11
Chapter 2 Component Descriptions 13
LCD Panel in EX3200 and EX4200 Switches .................................................13
LCD Panel Modes ....................................................................................14
LCD Panel Menus ....................................................................................15
Field-Replaceable Units in EX3200 and EX4200 Switches .............................16
Chassis Status LEDs in EX3200 Switches .......................................................17
Chassis Status LEDs in EX4200 Switches .......................................................18
Network Port LEDs in EX3200 and EX4200 Switches ....................................20
Management Port LEDs in EX3200 and EX4200 Switches ............................24
Table of Contents vii
Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches
Power Supply in EX3200 and EX4200 Switches ............................................26
AC Power Supply LEDs in EX3200 and EX4200 Switches .............................29
DC Power Supply LEDs in EX3200 and EX4200 Switches .............................30
Cooling System and Airflow in an EX3200 Switch .........................................31
Cooling System and Airflow in an EX4200 Switch .........................................32
Uplink Modules in EX3200 and EX4200 Switches .........................................33
SFP Uplink Module ..................................................................................34
SFP+ Uplink Module ..............................................................................35
XFP Uplink Module .................................................................................36
Chapter 3 Component Specifications 39
USB Port Specifications for an EX Series Switch ............................................39
Network Port Connector Pinout Information for an EX3200 or EX4200
Switch .....................................................................................................40
Console Port Connector Pinout Information for an EX Series Switch .............41
Management Port Connector Pinout Information for an EX3200 or EX4200
Switch .....................................................................................................42
Optical Interface Support in EX3200 and EX4200 Switches ..........................43
Uplink Modules Connector Pinout Information for EX3200 and EX4200
Switches .................................................................................................67
Virtual Chassis Ports Connector Pinout Information for EX4200 Switches .....74
Part 2 Planning for Switch Installation
Chapter 4 Site Preparation 81
Site Preparation Checklist for EX3200 and EX4200 Switches ........................81
General Site Guidelines for EX Series Switches ..............................................83
Site Electrical Wiring Guidelines for EX Series Switches ................................83
Environmental Requirements and Specifications for EX Series Switches .......85
Chapter 5 Mounting and Clearance Requirements 87
Rack Requirements for EX3200 and EX4200 Switches .................................87
Cabinet Requirements for EX3200 and EX4200 Switches .............................89
Requirements for Mounting an EX3200 or EX4200 Switch on a Desktop or
Wall ........................................................................................................90
Clearance Requirements for Airflow and Hardware Maintenance for EX3200
and EX4200 Switches .............................................................................91
Chapter 6 Cable Specifications 95
Network Cable Specifications for EX3200 and EX4200 Switches ...................95
viii Table of Contents
Table of Contents
Chapter 7 Planning Power Requirements 97
Power Specifications for EX3200 and EX4200 Switches ................................97
AC Power Cord Specifications for EX3200 and EX4200 Switches ..................98
Chapter 8 Planning the Virtual Chassis 101
Understanding Virtual Chassis Hardware Configuration on an EX4200
Switch ...................................................................................................101
Planning the Virtual Chassis ........................................................................102
Virtual Chassis Cabling Configuration Examples for EX4200 Switches ........103
Adding a New Switch to an Existing Virtual Chassis Configuration (CLI
Procedure) ............................................................................................105
Adding a New Switch to an Existing Virtual Chassis Configuration Within
the Same Wiring Closet ..................................................................105
Adding a New Switch from a Different Wiring Closet to an Existing Virtual
Chassis Configuration .....................................................................106
Adding a New Switch to an Existing Preprovisioned Virtual Chassis
Configuration Using Autoprovisioning ............................................108
Part 3 Installing and Connecting the Switch and Switch Components
Chapter 9 Installing the Switch 113
Installing and Connecting an EX3200 or EX4200 Switch .............................113
Unpacking an EX3200 or EX4200 Switch ....................................................114
Mounting an EX3200 or EX4200 Switch .....................................................116
Mounting an EX3200 or EX4200 Switch on a Desk or Other Level
Surface ..................................................................................................117
Mounting an EX3200 or EX4200 Switch on Two Posts in a Rack or
Cabinet .................................................................................................118
Mounting an EX3200 or EX4200 Switch on Four Posts in a Rack or
Cabinet .................................................................................................121
Mounting an EX3200 or EX4200 Switch in a Recessed Position in a Rack or
Cabinet .................................................................................................124
Mounting an EX3200 or EX4200 Switch on a Wall ......................................125
Chapter 10 Installing Switch Components 129
Installing and Removing EX3200 and EX4200 Switch Hardware
Components .........................................................................................129
Installing a Power Supply in an EX3200 or EX4200 Switch .........................130
Installing a Fan Tray in an EX3200 or EX4200 Switch .................................132
Installing an Uplink Module in an EX3200 or EX4200 Switch ......................133
Installing a Transceiver in an EX Series Switch ............................................136
Table of Contents ix
Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches
Connecting a Virtual Chassis Cable to an EX4200 Switch ............................137
Chapter 11 Connecting the Switch 141
Connecting Earth Ground to an EX Series Switch ........................................141
Connecting Earth Ground to an EX2200 or EX3200 Switch ..................142
Connecting Earth Ground to an EX4200 Switch ....................................142
Connecting Earth Ground to an EX8208 Switch ....................................144
Connecting Earth Ground to an EX8216 Switch ....................................145
Connecting AC Power to an EX3200 or EX4200 Switch ..............................146
Connecting DC Power to an EX3200 or EX4200 Switch ..............................148
Connecting an EX Series Switch to a Network for Out-of-Band
Management .........................................................................................152
Connecting an EX Series Switch to a Management Console ........................153
Connecting an EX Series Switch to a Modem ..............................................155
Setting the Serial Console Speed for the Switch ....................................155
Configuring the Modem ........................................................................156
Connecting the Modem to the Console Port ..........................................157
Connecting a Fiber-Optic Cable to an EX Series Switch ...............................159
Chapter 12 Performing Initial Configuration 161
Connecting and Configuring an EX Series Switch (CLI Procedure) ...............161
Connecting and Configuring an EX Series Switch (J-Web Procedure) ...........163
Configuring the LCD Panel Display on EX Series Switches (CLI
Procedure) ............................................................................................166
Disabling the Maintenance Menu ..........................................................166
Enabling the Maintenance Menu ...........................................................166
Configuring a Custom Display Message ................................................167
Setting the Mode on an SFP+ Uplink Module (CLI Procedure) ....................168
Part 4 Removing Switch Components
Chapter 13 Removing Switch Components 171
Installing and Removing EX3200 and EX4200 Switch Hardware
Components .........................................................................................171
Removing a Power Supply from an EX3200 or EX4200 Switch ...................172
Removing a Fan Tray from an EX3200 or EX4200 Switch ..........................174
Removing an Uplink Module from an EX3200 or EX4200 Switch ...............175
Removing a Transceiver from an EX Series Switch .....................................177
Disconnecting a Fiber-Optic Cable from an EX Series Switch ......................179
x Table of Contents
Table of Contents
Disconnecting a Virtual Chassis Cable from an EX4200 Switch ...................180
Replacing a Member Switch of a Virtual Chassis Configuration (CLI
Procedure) ............................................................................................182
Remove, Repair, and Reinstall the Same Switch ...................................182
Remove a Member Switch, Replace with a Different Switch, and Reapply
the Old Configuration .....................................................................182
Remove a Member Switch and Make Its Member ID Available for
Reassignment to a Different Switch ................................................183
Part 5 Switch and Component Maintenance
Chapter 14 Routine Maintenance 187
Maintaining Fiber-Optic Cables in EX Series Switches .................................187
Part 6 Troubleshooting Switch Components
Chapter 15 Troubleshooting Switch Components 191
Troubleshooting Network Interfaces on EX3200 and EX4200 Switches ......191
The interface on one of the last four built-in network ports in an EX3200
switch (for example, interface ge-0/0/23) is down ..........................191
The interface on the port in which an SFP or SFP+ transceiver is installed
in an SFP+ uplink module is down ................................................192
Troubleshooting Uplink Module Installation or Replacement on EX3200 and
EX4200 Switches ..................................................................................192
Virtual Chassis port (VCP) connection does not work ............................192
One of the last four network ports on an EX3200 switch with an SFP or
SFP+ uplink module installed is disabled ......................................193
Part 7 Returning Hardware
Chapter 16 Returning the Switch or Switch Components 197
Returning an EX3200 or EX4200 Switch or Component for Repair or
Replacement .........................................................................................197
Locating the Serial Number on an EX3200 or EX4200 Switch or
Component ...........................................................................................198
Listing the Switch and Components Details with the CLI .......................198
Locating the Chassis Serial Number ID Label on an EX3200 or EX4200
Switch ............................................................................................198
Table of Contents xi
Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches
Locating the Serial Number ID Labels on FRUs in an EX3200 or EX4200
Switch ............................................................................................199
Contacting Customer Support to Obtain Return Materials Authorization for
EX Series Switches ................................................................................199
Packing an EX3200 or EX4200 Switch or Component for Shipping .............201
Packing an EX3200 or EX4200 Switch for Shipping ..............................201
Packing EX3200 or EX4200 Switch Components for Shipping ..............202
Part 8 Safety Information
Chapter 17 General Safety Information 207
General Safety Guidelines and Warnings for EX Series Switches .................207
Definitions of Safety Warning Levels for EX Series Switches .......................208
Fire Safety Requirements for EX Series Switches ........................................210
Qualified Personnel Warning for EX Series Switches ...................................211
Warning Statement for Norway and Sweden for EX Series Switches ...........212
Chapter 18 Radiation and Laser Warnings 213
Laser and LED Safety Guidelines and Warnings for EX Series Switches .......213
General Laser Safety Guidelines ............................................................213
Class 1 Laser Product Warning .............................................................214
Class 1 LED Product Warning ...............................................................214
Laser Beam Warning ............................................................................215
Radiation from Open Port Apertures Warning for EX Series Switches .........216
Chapter 19 Installation and Maintenance Safety Information 219
Installation Instructions Warning for EX Series Switches .............................219
Chassis Lifting Guidelines for EX3200 and EX4200 Switches ......................220
Ramp Warning for EX Series Switches ........................................................221
Rack-Mounting and Cabinet-Mounting Warnings for EX Series Switches .....221
Wall-Mounting Warning for EX3200 and EX4200 Switches .........................225
Grounded Equipment Warning for EX Series Switches ................................226
Maintenance and Operational Safety Guidelines and Warnings for EX Series
Switches ...............................................................................................227
Battery Handling Warning ....................................................................227
Jewelry Removal Warning .....................................................................228
Lightning Activity Warning ...................................................................230
Operating Temperature Warning ..........................................................231
Product Disposal Warning ....................................................................232
xii Table of Contents
Table of Contents
Chapter 20 Power and Electrical Safety Information 235
General Electrical Safety Guidelines and Warnings for EX Series
Switches ...............................................................................................235
Prevention of Electrostatic Discharge Damage on EX Series Switches .........236
AC Power Electrical Safety Guidelines for EX Series Switches ......................238
AC Power Disconnection Warning for EX Series Switches ...........................239
Multiple Power Supplies Disconnection Warning for EX Series Switches .....240
Power Sources for Redundant Power Supplies Warning for EX4200
Switches ...............................................................................................240
DC Power Electrical Safety Guidelines for EX Series Switches .....................241
DC Power Disconnection Warning for EX Series Switches ...........................242
DC Power Grounding Requirements and Warning for EX Series Switches ....244
DC Power Wiring Sequence Warning for EX Series Switches ......................245
DC Power Wiring Terminations Warning for EX Series Switches .................246
TN Power Warning for EX Series Switches ..................................................247
In Case of Electrical Accident: Action to Take on an EX Series Switch .........248
Part 9 Compliance Information
Chapter 21 Compliance Information 253
Agency Approvals for EX Series Switches ....................................................253
Compliance Statements for EMC Requirements for EX Series Switches .......254
Canada .................................................................................................254
European Community ...........................................................................255
Japan ....................................................................................................255
United States ........................................................................................255
FCC Part 15 Statement .........................................................................255
Non-Regulatory Environmental Standards ............................................256
Compliance Statements for Acoustic Noise for EX Series Switches ..............256
Table of Contents xiii
Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches
xiv Table of Contents

List of Figures

Part 1 Switch and Components Overview and Specifications
Chapter 1 EX3200 and EX4200 Switches Overview 3
Figure 1: EX3200 Switch with 48 Gigabit Ethernet Ports .................................8
Figure 2: EX3200 Switch with 24 Gigabit Ethernet Ports .................................8
Figure 3: EX3200 Switch Rear Panel ...............................................................9
Figure 4: EX4200 Switch with 48 Gigabit Ethernet Ports ...............................10
Figure 5: EX4200 Switch with 24 Gigabit Ethernet Ports ...............................10
Figure 6: EX4200-24F Switch with 24 SFP Ports ...........................................11
Figure 7: EX4200 Switch Rear Panel .............................................................12
Chapter 2 Component Descriptions 13
Figure 8: LCD Panel in EX3200 and EX4200 Switches ..................................13
Figure 9: Chassis Status LEDs in an EX3200 Switch ......................................17
Figure 10: Chassis Status LEDs in an EX4200 Switch ....................................19
Figure 11: LEDs on the Network Ports on the Front Panel .............................20
Figure 12: LEDs on the Uplink Module Ports on the SFP Uplink Module ........20
Figure 13: LEDs on the Uplink Module Ports on the SFP+ Uplink Module .....21
Figure 14: LEDs on the Uplink Module Ports on the XFP Uplink Module ........21
Figure 15: LEDs on the Management Port on an EX3200 Switch ...................25
Figure 16: LEDs on the Management Port on an EX4200 Switch ...................25
Figure 17: 320 W AC Power Supply in EX3200 and EX4200 Switches ..........27
Figure 18: 600 W and 930 W AC Power Supplies in EX3200 and EX4200
Switches .................................................................................................27
Figure 19: DC Power Supply in EX3200 and EX4200 Switches .....................27
Figure 20: Fan Tray Used in an EX3200 Switch .............................................31
Figure 21: Airflow Through the EX3200 Switch Chassis ................................31
Figure 22: Fan Tray Used in an EX4200 Switch .............................................32
Figure 23: Airflow Through the EX4200 Switch Chassis ................................33
Figure 24: SFP Uplink Module .......................................................................34
Figure 25: SFP+ Uplink Module ....................................................................35
Figure 26: XFP Uplink Module .......................................................................37
Part 2 Planning for Switch Installation
Chapter 5 Mounting and Clearance Requirements 87
Figure 27: Clearance Requirements for Airflow and Hardware Maintenance
for EX3200 and EX4200 Switches ..........................................................91
Figure 28: Airflow Through the EX3200 Switch Chassis ................................92
Figure 29: Airflow Through the EX4200 Switch Chassis ................................92
Chapter 7 Planning Power Requirements 97
Figure 30: AC Plug Types ..............................................................................99
List of Figures xv
Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches
Chapter 8 Planning the Virtual Chassis 101
Figure 31: EX4200 Switches Mounted on a Single Rack and Connected in a
Ring Topology Using Short and Long Cables: Option 1 .........................103
Figure 32: EX4200 Switches Mounted on a Single Rack and Connected in a
Ring Topology Using Short and Long Cables: Option 2 .........................104
Figure 33: EX4200 Switches Mounted on a Single Rack and Connected in a
Ring Topology Using Short and Medium Cables ....................................104
Figure 34: EX4200 Switches Mounted on Adjacent Racks and Connected in
a Ring Topology Using Medium and Long Cables: Option 1 ..................104
Figure 35: EX4200 Switches Mounted on Adjacent Racks and Connected in
a Ring Topology Using Medium and Long Cables: Option 2 ..................105
Part 3 Installing and Connecting the Switch and Switch Components
Chapter 9 Installing the Switch 113
Figure 36: Unpacking an EX3200 or EX4200 Switch ...................................115
Figure 37: Attaching Rubber Feet to an EX3200 or EX4200 Switch
Chassis ..................................................................................................118
Figure 38: Attaching the Mounting Bracket Along the Front of the Switch ....119
Figure 39: Mounting the Switch on Two Posts in a Rack ..............................120
Figure 40: Attaching the Front Bracket to the Side-Rail Bracket ...................122
Figure 41: Attaching the Side-Rail Bracket to the Switch Chassis .................123
Figure 42: Mounting the Switch to the Front Posts in a Rack .......................123
Figure 43: Sliding the Rear Brackets to the Rear of a Four-Post Rack ...........124
Figure 44: Attaching Wall-Mount Brackets to an EX3200 or EX4200 Switch
Chassis ..................................................................................................126
Figure 45: Mounting an EX3200 or EX4200 Switch on a Wall .....................127
Chapter 10 Installing Switch Components 129
Figure 46: Installing a Power Supply in an EX3200 or EX4200 Switch ........131
Figure 47: Installing a Fan Tray in an EX3200 Switch ..................................132
Figure 48: Installing a Fan Tray in an EX4200 Switch ..................................133
Figure 49: Installing an Uplink Module in an EX3200 or EX4200 Switch .....135
Figure 50: Installing a Transceiver in an EX Series Switch ...........................137
Figure 51: Connecting a Virtual Chassis Cable to an EX4200 Switch ...........138
Chapter 11 Connecting the Switch 141
Figure 52: Connecting a Grounding Cable to an EX Series Switch ...............141
Figure 53: Connecting the Grounding Lug to an EX4200 Switch on a Four-Post
Rack .....................................................................................................144
Figure 54: Connecting the AC Power Cord Retainer Clip to an AC Power
Supply in an EX3200 or EX4200 Switch ...............................................147
Figure 55: Connecting an AC Power Cord to an AC Power Supply in an
EX3200 or EX4200 Switch ....................................................................148
Figure 56: DC Power Supply in an EX3200 or EX4200 Switch ....................148
Figure 57: Removing the Terminal Block Cover from a DC Power Supply in
an EX3200 or EX4200 Switch ...............................................................150
Figure 58: Securing Ring Lugs to the Terminals on the DC Power Supply in
an EX3200 or EX4200 Switch ...............................................................151
Figure 59: Ethernet Cable Connector ...........................................................152
Figure 60: Connecting an EX Series Switch to a Network for Out-of-Band
Management .........................................................................................153
xvi List of Figures
Figure 61: Ethernet Cable Connector ...........................................................153
Figure 62: Connecting an EX Series Switch to a Management Console Through
a Console Server ...................................................................................154
Figure 63: Connecting an EX Series Switch Directly to a Management
Console .................................................................................................154
Figure 64: Ethernet Cable Connector ...........................................................158
Figure 65: Connecting a Fiber-Optic Cable to an Optical Transceiver Installed
in an EX Series Switch ..........................................................................159
Chapter 12 Performing Initial Configuration 161
Figure 66: LCD Panel in an EX3200, EX4200, or EX8200 Switch ................164
Part 4 Removing Switch Components
Chapter 13 Removing Switch Components 171
Figure 67: Removing a Power Supply from an EX3200 or EX4200
Switch ...................................................................................................173
Figure 68: Removing a Fan Tray from an EX3200 Switch ...........................175
Figure 69: Removing a Fan Tray from an EX4200 Switch ...........................175
Figure 70: Sliding the Screwdriver to the Narrow Part of the Keyhole .........177
Figure 71: Removing an Uplink Module from an EX3200 or EX4200
Switch ...................................................................................................177
Figure 72: Removing a Transceiver from an EX Series Switch .....................179
Figure 73: Virtual Chassis Cable Connector in an EX4200 Switch ................181
List of Figures
Part 7 Returning Hardware
Chapter 16 Returning the Switch or Switch Components 197
Figure 74: Location of the Serial Number ID Label on an EX3200 Switch ....199
Figure 75: Location of the Serial Number ID Label on an EX4200 Switch ....199
Part 8 Safety Information
Chapter 20 Power and Electrical Safety Information 235
Figure 76: Place a Component into an Antistatic Bag ..................................237
List of Figures xvii
Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches
xviii List of Figures

List of Tables

Part 1 Switch and Components Overview and Specifications
Chapter 1 EX3200 and EX4200 Switches Overview 3
Table 1: EX3200 Switch Models ......................................................................6
Table 2: EX4200 Switch Models ......................................................................6
Table 3: Physical Specifications of the EX3200 and EX4200 Switch
Chassis ......................................................................................................7
Chapter 2 Component Descriptions 13
Table 4: LCD Panel Menu Options in EX3200 and EX4200 Switches .............15
Table 5: Chassis Status LEDs in an EX3200 Switch ........................................18
Table 6: Chassis Status LEDs in an EX4200 Switch ........................................19
Table 7: Link/Activity LED on Network Ports in EX3200 and EX4200
Switches .................................................................................................22
Table 8: Status LED on Network Ports in EX3200 and EX4200 Switches .......23
Table 9: Link/Activity LED on the Management Port on an EX3200 or EX4200
Switch .....................................................................................................25
Table 10: Status LED on the Management Port on an EX3200 or EX4200
Switch .....................................................................................................25
Table 11: Minimum Power Requirements for an EX3200 Switch ..................28
Table 12: Minimum Power Requirements for an EX4200 Switch ..................28
Table 13: AC Power Supply LEDs in EX3200 and EX4200 Switches ..............29
Table 14: DC Power Supply LEDs in EX3200 and EX4200 Switches ..............30
Chapter 3 Component Specifications 39
Table 15: Network Port Connector Pinout Information for an EX3200 or
EX4200 Switch .......................................................................................40
Table 16: EX Series Switches Console Port Connector Pinout
Information ............................................................................................41
Table 17: Management Port Connector Pinout Information for an EX3200
or EX4200 Switch ...................................................................................42
Table 18: Optical Interface Support and Copper Interface Support for Gigabit
Ethernet SFP Transceivers in EX3200 and EX4200 Switches ..................44
Table 19: Optical Interface Support for Fast Ethernet SFP Transceivers in
EX3200 and EX4200 Switches ................................................................55
Table 20: Optical Interface Support for Gigabit Ethernet SFP+ Transceivers
in EX3200 and EX4200 Switches ............................................................61
Table 21: Optical Interface Support for Gigabit Ethernet XFP Transceivers in
EX3200 and EX4200 Switches ................................................................64
Table 22: Uplink Modules Connector Pinout Information for EX3200 and
EX4200 Switches ....................................................................................68
Table 23: Virtual Chassis Ports (VCPs) Connector Pinout Information ...........75
List of Tables xix
Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches
Part 2 Planning for Switch Installation
Chapter 4 Site Preparation 81
Table 24: Site Preparation Checklist ..............................................................81
Table 25: Site Electrical Wiring Guidelines .....................................................84
Table 26: EX Series Switch Environmental Tolerances ..................................85
Chapter 5 Mounting and Clearance Requirements 87
Table 27: Rack Requirements and Specifications for the Switch ....................87
Table 28: Cabinet Requirements and Specifications for the Switch ...............89
Chapter 7 Planning Power Requirements 97
Table 29: AC Power Supply Electrical Specifications for EX3200 and EX4200
Switches .................................................................................................97
Table 30: DC Power Supply Electrical Specifications for EX3200 and EX4200
Switches .................................................................................................97
Table 31: AC Power Cord Specifications ........................................................98
Part 3 Installing and Connecting the Switch and Switch Components
Chapter 9 Installing the Switch 113
Table 32: Inventory of Components Provided with an EX3200 or EX4200
Switch ...................................................................................................115
Chapter 11 Connecting the Switch 141
Table 33: Port Settings ................................................................................157
xx List of Tables

About This Topic Collection

How to Use This Guide on page xxi
List of EX Series Guides for JUNOS Release 10.1 on page xxi
Downloading Software on page xxiii
Documentation Symbols Key on page xxiii
Documentation Feedback on page xxv
Requesting Technical Support on page xxv

How to Use This Guide

Complete documentation for the EX Series product family is provided on webpages at http://www.juniper.net/techpubs/en_US/release-independent/
information-products/pathway-pages/ex-series/product/index.html. We have selected content
from these webpages and created a number of EX Series guides that collect related topics into a book-like format so that the information is easy to print and easy to download to your local computer.
This guide, Complete Hardware Guide for EX3200 and EX4200 Switches, collects together information about the EX3200 fixed-configuration and EX4200 virtual-chassis switches. The release notes are at
http://www.juniper.net/techpubs/en_US/junos10.1/information-products/topic-collections/ release-notes/10.1/junos-release-notes-10.1.pdf.

List of EX Series Guides for JUNOS Release 10.1

DescriptionTitle
Complete Hardware Guide for EX2200 Switches
Complete Hardware Guide for EX3200 and EX4200 Switches
Complete Hardware Guide for EX8208 Switches
Component descriptions, site preparation, installation, replacement, and safety and compliance information for EX2200 switches
Component descriptions, site preparation, installation, replacement, and safety and compliance information for EX3200 and EX4200 switches
Component descriptions, site preparation, installation, replacement, and safety and compliance information for EX8208 switches
How to Use This Guide xxi
Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches
DescriptionTitle
Complete Hardware Guide for EX8216 Switches
Complete Software Guide for JUNOS® Software for EX Series Switches, Release 10.1
Software Topic Collections
JUNOS® Software for EX Series Switches, Release 10.1: Access Control
JUNOS® Software for EX Series Switches, Release 10.1: Alarms and System Log Messages
JUNOS® Software for EX Series Switches, Release 10.1: Configuration and File Management
JUNOS® Software for EX Series Switches, Release 10.1: Class of Service
JUNOS® Software for EX Series Switches, Release 10.1: Device Security
JUNOS® Software for EX Series Switches, Release 10.1: Ethernet Switching
Component descriptions, site preparation, installation, replacement, and safety and compliance information for EX8216 switches
Software feature descriptions, configuration examples, and tasks for JUNOS Software for EX Series switches
Software feature descriptions, configuration examples and tasks, and reference pages for configuration statements and operational commands (This information also appears in the Complete Software
Guide for JUNOS® Software for EX Series Switches, Release 10.1.)
JUNOS® Software for EX Series Switches, Release 10.1: Interfaces
JUNOS® Software for EX Series Switches, Release 10.1: Layer 3 Protocols
JUNOS® Software for EX Series Switches, Release 10.1: MPLS
JUNOS® Software for EX Series Switches, Release 10.1: Multicast
JUNOS® Software for EX Series Switches, Release 10.1: Network Management and Monitoring
JUNOS® Software for EX Series Switches, Release 10.1: Port Security
JUNOS® Software for EX Series Switches, Release 10.1: Routing Policy and Packet Filtering
JUNOS® Software for EX Series Switches, Release 10.1: Spanning-Tree Protocols
JUNOS® Software for EX Series Switches, Release 10.1: System Setup
JUNOS® Software for EX Series Switches, Release 10.1: User and Access Management
JUNOS® Software for EX Series Switches, Release 10.1: Virtual Systems
xxii List of EX Series Guides for JUNOS Release 10.1

Downloading Software

You can download JUNOS Software for EX Series switches from the Download Software area at http://www.juniper.net/customers/support/ . To download the software, you must have a Juniper Networks user account. For information about obtaining an account, see http://www.juniper.net/entitlement/setupAccountInfo.do.

Documentation Symbols Key

Notice Icons
About This Topic Collection
DescriptionMeaningIcon
Indicates important features or instructions.Informational note
Text and Syntax Conventions
Bold text like this
Fixed-width text like this
Italic text like this
Indicates a situation that might result in loss of data or hardware damage.Caution
Alerts you to the risk of personal injury or death.Warning
Alerts you to the risk of personal injury from a laser.Laser warning
Represents text that you type.
Represents output that appears on the terminal screen.
Introduces important new terms.
Identifies book names.
Identifies RFC and Internet draft
titles.
ExamplesDescriptionConvention
To enter configuration mode, type the
configure command:
user@host> configure
user@host> show chassis alarms No alarms currently active
A policy term is a named structure
that defines match conditions and actions.
JUNOS System Basics Configuration
Guide RFC 1997, BGP Communities
Attribute
Downloading Software xxiii
Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches
Text and Syntax Conventions
ExamplesDescriptionConvention
Italic text like this
Plain text like this
| (pipe symbol)
# (pound sign)
[ ] (square brackets)
Indention and braces ( { } )
Represents variables (options for which you substitute a value) in commands or configuration statements.
Represents names of configuration statements, commands, files, and directories; IP addresses; configuration hierarchy levels; or labels on routing platform components.
Enclose optional keywords or variables.< > (angle brackets)
Indicates a choice between the mutually exclusive keywords or variables on either side of the symbol. The set of choices is often enclosed in parentheses for clarity.
Indicates a comment specified on the same line as the configuration statement to which it applies.
Enclose a variable for which you can substitute one or more values.
Identify a level in the configuration hierarchy.
Configure the machines domain name:
[edit] root@# set system domain-name
domain-name
To configure a stub area, include
the stub statement at the [edit
protocols ospf area area-id] hierarchy
level. The console port is labeled
CONSOLE.
stub <default-metric metric>;
broadcast | multicast
(string1 | string2 | string3)
rsvp { # Required for dynamic MPLS only
community name members [ community-ids ]
[edit] routing-options {
static {
route default {
nexthop address; retain;
}
}
}
; (semicolon)
J-Web GUI Conventions
Bold text like this
> (bold right angle bracket)
xxiv Documentation Symbols Key
Identifies a leaf statement at a configuration hierarchy level.
Represents J-Web graphical user interface (GUI) items you click or select.
Separates levels in a hierarchy of J-Web selections.
In the Logical Interfaces box, select
All Interfaces. To cancel the configuration, click
Cancel.
In the configuration editor hierarchy, select Protocols>Ospf.

Documentation Feedback

We encourage you to provide feedback, comments, and suggestions so that we can improve the documentation. Send e-mail to techpubs-comments@juniper.net with the following:
Document URL or title
Page number if applicable
Software version
Your name and company

Requesting Technical Support

Technical product support is available through the Juniper Networks Technical Assistance Center (JTAC). If you are a customer with an active J-Care or JNASC support contract, or are covered under warranty, and need post-sales technical support, you can access our tools and resources online or open a case with JTAC.
About This Topic Collection
JTAC policiesFor a complete understanding of our JTAC procedures and policies,
review the JTAC User Guide located at
http://www.juniper.net/customers/support/downloads/7100059-EN.pdf .
Product warrantiesFor product warranty information, visit
http://www.juniper.net/support/warranty/ .
JTAC hours of operationThe JTAC centers have resources available 24 hours a
day, 7 days a week, 365 days a year.

Self-Help Online Tools and Resources

For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features:
Find CSC offerings: http://www.juniper.net/customers/support/
Search for known bugs: http://www2.juniper.net/kb/
Find product documentation: http://www.juniper.net/techpubs/
Find solutions and answer questions using our Knowledge Base:
http://kb.juniper.net/
Download the latest versions of software and review release notes:
http://www.juniper.net/customers/csc/software/
Search technical bulletins for relevant hardware and software notifications:
https://www.juniper.net/alerts/
Join and participate in the Juniper Networks Community Forum:
http://www.juniper.net/company/communities/
Open a case online in the CSC Case Management tool: http://www.juniper.net/cm/
Documentation Feedback xxv
Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches
To verify service entitlement by product serial number, use our Serial Number Entitlement (SNE) Tool: https://tools.juniper.net/SerialNumberEntitlementSearch/

Opening a Case with JTAC

You can open a case with JTAC on the Web or by telephone.
Use the Case Management tool in the CSC at http://www.juniper.net/cm/ .
Call 1-888-314-JTAC (1-888-314-5822 toll-free in the USA, Canada, and Mexico).
For international or direct-dial options in countries without toll-free numbers, see
http://www.juniper.net/support/requesting support.html .
xxvi Requesting Technical Support
Part 1
Switch and Components Overview and Specifications
EX3200 and EX4200 Switches Overview on page 3
Component Descriptions on page 13
Component Specifications on page 39
Switch and Components Overview and Specifications 1
Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches
2 Switch and Components Overview and Specifications
Chapter 1
EX3200 and EX4200 Switches Overview
EX3200 and EX4200 Switches Hardware Overview on page 3
EX3200 Switch Models on page 6
EX4200 Switch Models on page 6
Chassis Physical Specifications for EX3200 and EX4200 Switches on page 7
Front Panel of an EX3200 Switch on page 8
Rear Panel of an EX3200 Switch on page 9
Front Panel of an EX4200 Switch on page 10
Rear Panel of an EX4200 Switch on page 11

EX3200 and EX4200 Switches Hardware Overview

Juniper Networks EX Series Ethernet Switches provide scalable connectivity for the enterprise market, including branch offices, campus locations, and data centers. The switches run under the Juniper Networks JUNOS Software, which provides Layer 2 and Layer 3 switching, routing, and security services. The same JUNOS code base that runs on EX Series switches also runs on all Juniper Networks J Series, M Series, MX Series, and T Series routers.
EX3200 and EX4200 Switch Types on page 3
EX3200 Switches on page 4
EX4200 Switches on page 4
Uplink Modules on page 5
Power over Ethernet (PoE) Ports on page 5
EX3200 and EX4200 Switch Types
Juniper Networks EX3200 and EX4200 Ethernet Switches are two closely related product lines:
EX3200 switches—Typically, you deploy these switches in branch environments
or wiring closets.
EX4200 switches—You can interconnect EX4200 switches to form a Virtual
Chassis that operates as a single network entity. You can deploy these switches wherever you need a high density of Gigabit Ethernet ports (24 to 480 ports), redundancy, or the ability to span a single switch across several wiring closets.
EX3200 and EX4200 Switches Hardware Overview 3
Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches
Typically, EX4200 switches are used in large branch offices, campus wiring closets, and top-of-rack locations in a data center.
Both lines have these features:
Run under JUNOS Software for EX Series switches
Have options of 24-port and 48-port models
Have options of full (all ports) or partial (8 ports) Power over Ethernet (PoE)
capability
Have optional uplink modules that provide connection to distribution switches
EX3200 Switches
EX3200 switches provide connectivity for low-density environments. Typically, you deploy these switches in branch environments or wiring closets where only one switch is required.
EX4200 Switches
EX3200 switches are available in models with either 24 or 48 ports and with either all ports equipped for Power over Ethernet (PoE) or only 8 ports equipped for PoE. All models provide ports that have 10/100/1000Base-T Gigabit Ethernet connectors and optional 1-gigabit small form-factor pluggable (SFP) transceivers, 10-gigabit small form-factor pluggable (SFP+) transceivers, or 10-gigabit small form-factor pluggable (XFP) transceivers for use with fiber connections.
EX3200 switches include:
A field-replaceable power supply and an optional additional connection to an
external power source.
A field-replaceable fan tray with single fan.
JUNOS Software with its modular design that enables failed system processes to
gracefully restart.
EX4200 switches provide connectivity for medium- and high-density environments and scalability for growing networks. These switches can be deployed wherever you need a high density of Gigabit Ethernet ports (24 to 480 ports) or redundancy. Typically, EX4200 switches are used in large branch offices, campus wiring closets, and data centers where they can be positioned as the top device in a rack to provide connectivity for all the devices in the rack.
You can connect individual EX4200 switches together to form one unit and manage the unit as a single chassis, called a Virtual Chassis. You can add more member switches to the Virtual Chassis as needed, up to a total of 10 members.
EX4200 switches are available in models with 24 or 48 ports and with either all ports equipped for Power over Ethernet (PoE) or only 8 ports equipped for PoE. All models provide ports that have 10/100/1000Base-T Gigabit Ethernet connectors and optional 1-gigabit small form-factor pluggable (SFP) transceivers, 10-gigabit small form-factor
4 EX3200 and EX4200 Switches Hardware Overview
Loading...
+ 254 hidden pages