Screw-in RTD temperature probes
with connecting cable
■ for temperatures from -50 to +400°C
■ as single or twin RTD temperature probe
■ in 2-wire, 3-wire or 4-wire circuit
■ connecting cable in PVC, silicone, PTFE or with metal braiding
Screw-in RTD temperature probes are mainly used for measuring temperatures in liquids
and gases. An important selection criterion is their reliable sealing against both negative
and positive pressures. Applications include HVAC, refrigeration, heating installations, ovens, furnaces and plant engineering.
Depending on the version, the connecting cables are suitable for use in dry and humid areas within the temperature range -50 to +350°C. The junction between cable and protection tube incorporates strain relief. A cable protector can be supplied as an option.
The measuring insert is normally fitted with a Pt100 temperature sensor to EN 60 751,
Class B in 2-wire circuit. Versions with Pt500 or Pt1000 are also available. In addition,
there is a choice of 3-wire or 4-wire circuit connections.
Data Sheet 90.2050 (90.2005)Page 1/5
Technical data
Connectionavailable with cable ends as: bare wires, with ferrules, receptacles or multipole connector
Connecting cablePVC, ambient temperature -5 to +80°C (+105°C)
silicone, ambient temperature -50 to +180°C
PTFE, ambient temperature -190 to +260°C
metal braiding, ambient temperature -50 to +350°C
connecting cable can optionally be supplied with shielding
Process connectionthread, stainless steel 1.4571
Protection tubestainless steel 1.4571 (Type 902050/30 Inconel 2.4816), 5mm, 5.4mm, 6mm and 8mm dia.
Measuring insertPt100 temperature sensor, EN 60 751, Cl. B, 2-wire circuit
Response timest
Accessoriespocket, see Data Sheet 90.9721 and 90.2440
approx. 2sec, t
0.5
approx. 6sec, in water 0.2m/sec, 6mm dia.
0.9
2011-03-31/00311471
Page 2
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14,
Postal address:
Phone:+49 661 6003-0
Fax:+49 661 6003-607
E-mail:mail@jumo.net
Internet:www.jumo.net
36039 Fulda, Germany
36035 Fulda, Germany
Dimensions
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow - Essex CM20 2DY, UK
Phone: +44 1279 63 55 33
Fax:+44 1279 63 52 62
E-mail: sales@jumo.co.uk
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone: 315-697-JUMO
Order details: Screw-in RTD temperature probes with connecting cable
(1) Basic version
1-800-554-JUMO
Data Sheet 90.2050 (90.2005)Page 3/5
902050/10
902050/20
Screw-in RTD temperature probe with fixed
screw fitting
Screw-in RTD temperature probe with loose
screw fitting
(2) Operating temperature in °C / connecting cable
x x130-200 to +400°C / metal braiding
x x380-50 to +200°C / silicone
x x386-50 to +260°C / PTFE
x x402-50 to +400°C / metal braiding
x x724-5 to +80°C / PVC
x x9125 to 105°C / PVC (only with 1 x 2-wire or 3-wire circuit)
(3) Measuring insert
x x10011 x Pt100 in 3-wire circuit
x x10031 x Pt100 in 2-wire circuit
x x10111 x Pt100 in 4-wire circuit
x x20012 x Pt100 in 3-wire circuit
x x20032 x Pt100 in 2-wire circuit
(4) Tolerance class to EN 60 751
xx1Class B (standard)
xx2Class A
(5) Protection tube diameter D in mm
xx55mm
xx66mm
(6) Fitting length EL in mm (50≤ EL ≤500)
x1717mm
x3737mm
x x5050mm
x x100100mm
x137137mm
x x200200mm
x250250mm
x x...please specify in plain text (50mm steps)
(7) Process connection
x102thread 1/4"pipe
x104thread 1/2"pipe
x114thread M 10 x 1
(8) Connecting cable end
x x03bare cable ends
x x11ferrules to DIN 46 228 Part 4 (standard)
x x13receptacle 6.3 to DIN 46 247
x x80multipole connector (please specify type in plain text)
x x99to customer specification
(9) Connecting cable length AL in mm (500≤ AL ≤500000)
x x25002500mm
x x...please specify in plain text (500mm steps)
(10) Extra codes
x x000no extra code
x x310stepped protection tube
x x315cable protector: coil
x x316cable protector: tube
x x317shielded connecting cable
Order details: Screw-in RTD temperature probes with connecting cable
(1) Basic version
1-800-554-JUMO
Data Sheet 90.2050 (90.2005)Page 4/5
902050/30
Screw-in RTD temperature probe with loose
screw fitting and stepped protection tube
(2) Operating temperature in °C / connecting cable
x380-50 to +200°C / silicone
(3) Measuring insert
x10011 x Pt100 in 3-wire circuit
x10031 x Pt100 in 2-wire circuit
(4) Tolerance class to EN 60 751
x1Class B (standard)
x2Class A
(5) Protection tube diameter D in mm
x5.45.4mm dia. stepped down to 3.3mm
(6) Fitting length EL in mm
x27.527.5mm
(7) Process connection
x114thread M 10 x 1
(8) Connecting cable end
x03bare cable ends
x11ferrules to DIN 46 228 Part 4 (standard)
x13receptacle 6.3 to DIN 46 247
x80multipole connector (please specify type in plain text)
x99to customer specification
(9) Connecting cable length AL in mm (500≤ AL ≤500000)
x25002500mm
x...please specify in plain text (500mm steps)
Order details: Screw-in RTD temperature probes with connecting cable
(1) Basic version
1-800-554-JUMO
Data Sheet 90.2050 (90.2005)Page 5/5
902050/40
Screw-in RTD temperature probe, screw-in
protection tube
(2) Operating temperature in °C / connecting cable
x380-50 to +200°C / silicone
x390-50 to +300°C / metal braiding
x724-5 to +80°C / PVC
x9125 to 105°C / PVC (only with 1 x 2-wire or 3-wire circuit)
(3) Measuring insert
x10011 x Pt100 in 3-wire circuit
x10031 x Pt100 in 2-wire circuit
(4) Tolerance class to EN 60 751
x1Class B (standard)
x2Class A
(5) Protection tube diameter D in mm
x8M 8
(6) Fitting length EL in mm
x2525mm
(7) Process connection
x111thread M 8
(8) Connecting cable end
x03bare cable ends
x11ferrules to DIN 46 228 Part 4 (standard)
x13receptacle 6.3 to DIN 46 247
x80multipole connector (please specify type in plain text)
x99to customer specification
(9) Connecting cable length AL in mm (500≤ AL ≤500000)
x25002500mm
x...please specify in plain text (500mm steps)