Screw-in RTD temperature probe with plug connector according to DIN EN 175301
• For temperatures between -50 and +260 °C
• Vibration-resistant design
• Plug connector locked against contact, protection type IP65
• Available with transmitter
• GL approval for basic types 902044/20 and 902044/21 (max. insertion length 200 mm)
Vibration-resistant screw-in RTD temperature probes allow temperatures to be measured under pressure in engines, compressors, plant engineering, and shipbuilding.
The plug connectors between the protection fitting and the connecting cable are locked against contact and have protection type IP65 when connected.
The measuring insert is a Pt100 temperature sensor according to DIN EN 60751, class B in 2­wire circuit as standard. Other versions with Pt500 or Pt1000 are also possible.
The connection can be carried out in a 2-wire or 4-wire circuit as required. Basic types 902044/25 to 902044/29 are available as versions with transmitters (output 4 to
20 mA).
Data sheet 902044 Page 1/8
Technical data
Connection Basic types 902044/15, 902044/20, 902044/25, 902044/28, and 902044/80:
Process connection Thread, stainless steel 1.4301/1.4571
Protection tube Stainless steel 1.4571, Ø 8 mm, Ø 6 mm stepped down to 3.3 mm,
Measuring insert Pt100 temperature sensor, DIN EN 60751, class B in 2-wire or 4-wire circuit, exchangeable. Short-
Protection type IP65 when connected
Response times Basic types 902044/15 and 902044/16: t
Vibration resistance Germanischer Lloyd, application category "D“, characteristic line 2
Approvals Basic types 902044/20 and 902044/21 GL Germanischer Lloyd
Accessories Thermowell, data sheet 902440
DIN EN 175301-803 plug connectors, Pg9 Basic types 902044/16, 902044/21, 902044/26, 902044/29, and 902044/81: DIN EN 175301-803 plug connectors, Pg11 Max. conductor cross section 1.5 mm For versions with transmitters: ambient temperature -40 to +85 °C
Max. pressure load 50 bar at 200 °C (basic types 902044/20 and 902044/21)
er fitting lengths in connection with unfavorable fitting conditions (heat dissipation error) can result in an exceedance of the tolerance class. The measuring insert is not exchangeable for versions equipped with transmitters.
Ø 6 mm stepped down to Ø 3.3 mm Basic types 902044/20 and 902044/21: t Basic types 902044/25 to 902044/29: t Ø 6 mm stepped down to Ø 3.3 mm Basic types 902044/80 and 902044/81: t
2
, IP65, ambient temperature -40 to +125 °C
0.5
0.5
= < 2 s, t
0.5
0.5
= < 2 s, t
= 15 s, t
= 5 s, t
= < 4 s, in water with 0.2 m/s,
0.9
= 45 s, in water with 0.2 m/s, Ø 8 mm
0.9
= < 4 s, in water with 0.2 m/s,
0.9
= 12 s, in water with 0.2 m/s, Ø 8 mm
0.9
Approvals/approval marks (see "Technical data")
2014-05-16/00534480
JUMO GmbH & Co. KG Telefon: +49 661 6003-722/724 Hausadresse: Moritz-Juchheim-Straße 1, 36039 Fulda, Germany Telefax: +49 661 6003-601/688 Lieferadresse: Mackenrodtstraße 14, 36039 Fulda, Germany E-Mail: mail@jumo.net Postadresse: 36035 Fulda, Germany Internet: www.jumo.net
Technical data
Transmitter Input
Measuring input Pt100 acc. to DIN EN 60751
Measuring range limits -50 to +260 °C
Measuring span 25 to 310 K (also see zero offset)
Zero offset Data sheet 707030, page 7/10
Sensor current ≤ 0.5 mA
Sampling rate Permanent measurement due to analog signal path
Measuring circuit monitoring Underrange Dropping to ≤ 3.6 mA Overrange Increasing to 22 mA to < 28 mA (typical 24 mA) Probe short circuit ≤ 3.6 mA Probe/cable break Positive: 22 mA to < 28 mA (typical 24 mA)
Output
Output signal Load-independent direct current: 4 to 20 mA
Transmission behavior Temperature-linear Transmission accuracy ≤ ±0.1%
Attenuation of the residual ripple of a voltage supply of 24 V, amplitude 10 V at 50 Hz, burden 470 Ω at load of 10 MΩ
Load (Rb) Rb = (Ub - 7.5 V) ÷ 22 mA Load error ≤ ±0.02% per 100 Ω
Setting time for temperature changes ≤ 10 ms
Calibration conditions DC 24 V at approx. 22 °C Calibration accuracy ≤ ±0.2%
Overall accuracy, probe/calibration ±0.4 K (typical) at 20 °C and DC 24 V voltage supply
Voltage supply
Voltage supply (Ub) DC 7.5 to 30 V
Reverse voltage protection Yes Voltage supply influence ±0.01% per V deviation from DC 24 V
Environmental influences
Operating temperature range -40 to +85 °C
Storage temperature range -40 to +100 °C Temperature influence ±0.01% per K deviation from 22 °C
Resistance to climatic conditions similar to DIN EN 60654 class D1
EMC EN 61326
- Interference emission Class B
- Interference immunity Industrial requirements
a
All specifications refer to the measuring range end value of 20 mA.
b
The higher value is valid.
Data sheet 902044 Page 2/8
For measuring spans < 75 K, fixed zero adjustment:
-40 °C, -20 °C, 0 °C, 20 °C, and 40 °C For measuring spans 75 K: ±50 °C
40 dB
a
a, b
or ≤ ±0.2 K
a
a
Relative humidity 95% annual average, no condensation
Approvals/approval marks
Approval mark
GL Germanischer Lloyd 15 700 - 00 HH Guidelines for the Performance of
2014-05-16/00534480
Testing agency Certificates/certification
numbers
Inspection basis valid for
Type Approvals Chapter 2, Edition 2003
Basic type 902044/20 ... Basic type 902044/21 ...
JUMO GmbH & Co. KG Telefon: +49 661 6003-722/724 Hausadresse: Moritz-Juchheim-Straße 1, 36039 Fulda, Germany Telefax: +49 661 6003-601/688 Lieferadresse: Mackenrodtstraße 14, 36039 Fulda, Germany E-Mail: mail@jumo.net Postadresse: 36035 Fulda, Germany Internet: www.jumo.net
Connection diagram
Data sheet 902044 Page 3/8
2014-05-16/00534480