Jenn-Air W2410B, W2410W Dimension Guide

Jenn-Air W2410B, W2410W Dimension Guide

www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600

 

This Data Sheet Includes Information On

 

 

 

 

Jenn-Air

 

 

 

24" min.

 

Product Model Number (s):

 

 

 

 

 

24" Electric Single Oven:

 

 

 

22 5/16"

24" min.

 

W2410B and W2410W

 

 

 

 

 

 

 

 

 

 

Dimensions (Actual Size)

 

Cabinet Opening

 

Provide for 120/208-240,

 

 

volt electrical

 

Cutout width:

22

5/16"

(not to scale)

 

 

 

connection in this area.

 

Cutout height:

28

3/8"

 

 

 

 

 

 

 

Minimum cabinet width:

24" min.

 

 

 

 

Minimum cabinet depth:

24" min.

 

 

 

 

Minimum cutout location from floor :

33

1/4"

 

C

28 3/8"

 

Distance from face of cabinet to

 

 

 

 

 

 

 

 

L

6"

 

outer edge of open door (door swing):

21

3/8"

 

 

 

Distance from face of cabinet to

 

 

 

24 11/16"

 

 

front of closed door handle:

4 9/16"

 

 

 

 

Overall unit width:

23

11/16"

 

 

 

 

Overall unit height:

28

7/8"

 

 

 

 

Penetration into cabinet:

22

5/8"

 

 

33 1/4"

 

Distance from opening floor

 

 

 

 

 

24

11/16"

 

 

 

 

to centerline of electrical:

 

 

 

 

Distance (right) from opening centerline

 

 

 

 

 

 

to centerline of electrical: 6"

 

 

 

 

 

Oven overlap distances when using

 

 

 

 

cutout dimensions listed above:

 

 

 

 

 

Top overlap: 1/2"

 

 

 

 

 

Bottom overlap: 0"

Right side overlap: 11/16"

 

Left side overlap: 11/16"

 

 

 

 

 

 

 

 

 

Overall Dimensions

Additional Information

(not to scale)

• Cutout in cabinet should be level and straight. There

 

 

 

 

 

 

 

 

are no provisions to level the unit after it is installed.

 

 

 

 

 

 

• Construct 5/8" Minimum plywood floor flush with

 

 

 

 

 

 

bottom of opening. Floor must be level and straight and

 

 

 

 

 

 

 

 

capable of supporting 135 lbs.

 

 

 

 

 

 

• A three-wire, single phase, A.C. 120/208-240 volt,

 

 

 

 

 

 

60Hz cycle electrical system must be provided (Load

 

 

 

 

 

 

15.0 amps @ 120/240VAC). 7/8" O.D. flexible cable 4

 

 

 

 

 

 

feet long is furnished by manufacturer.

 

 

 

 

 

 

• UL listed to be installed as a combination unit using

 

 

 

28 7/8"

 

Jenn-Air Microwave M167 with trim kit A424.

 

 

 

 

 

 

W2410B : Black.

W2410W : White.

 

 

 

 

22 5/8"

 

 

 

 

 

 

 

 

23 11/16"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Subject to change without notice. This system is designed to

 

 

4 9/16"

 

 

be updated daily if necessary. Dimension Express is not

 

 

 

 

responsible for use of superseded, voided, or outdated data

 

 

 

 

 

 

 

sheets. Because of the difficulty or impracticability of deter-

 

 

 

 

 

 

 

mining actual damages, liability of Dimension Express shall

 

 

 

 

 

 

 

not exceed $50.00.

 

 

 

 

 

 

 

Copyright © Dimension Express, 2000.

168

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• NEVER reuse Data Sheets. Data Sheets are subject to change without

• Call Dimension Express if you have any questions at (775) 833-3633 •

notice. Dimension Express is a FREE service bureau and is updated daily,

• Always refer to a current Code at a Glance or manufacturer directory •

it makes far more sense to spend the time necessary to request new Data

• Data Sheet codes change on the first of odd numbered months at 12:01am •

Sheets for each project, as opposed to the problems, time, costs, and risks

 

 

BN200.1 • A168 • 31469 • 002906 • 153650 • 16842

associated with reusing old Data Sheets.

 

 

 

 