Jenn-Air W2410B, W2410W Dimension Guide

www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
24" Electric Single Oven:
W2410B and W2410W
24" min.
22 5/16"
24" min.
• Dimensions (Actual Size) •
Cutout width:
Cutout height:
Minimum cabinet width:
22 5/16" 28 3/8" 24" min. 24" min.Minimum cabinet depth:
Minimum cutout location from floor :
Distance from face of cabinet to
outer edge of open door (door swing):
Distance from face of cabinet to
front of closed door handle:
Overall unit width:
Overall unit height:
Penetration into cabinet:
Distance from opening floor
to centerline of electrical:
24 11/16"
Distance (right) from opening centerline
to centerline of electrical:
6"
Oven overlap distances when using
cutout dimensions listed above:
Top overlap:
Bottom overlap:
Right side overlap:
1/2" 0" 11/16"
Left side overlap: 11/16"
• Additional Information •
• Cutout in cabinet should be level and straight. There
are no provisions to level the unit after it is installed.
• Construct 5/8" Minimum plywood floor flush with
bottom of opening. Floor must be level and straight and capable of supporting 135 lbs.
• A three-wire, single phase, A.C. 120/208-240 volt,
60Hz cycle electrical system must be provided (Load
15.0 amps @ 120/240VAC). 7/8" O.D. flexible cable 4
feet long is furnished by manufacturer.
• UL listed to be installed as a combination unit using
Jenn-Air Microwave M167 with trim kit A424.
• W2410B : Black.
• W2410W : White.
Cabinet Opening
(not to scale)
C
L
24 11/16"
Provide for 120/208-240, volt electrical connection in this area.
6"
Overall Dimensions
(not to scale)
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of deter­mining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2000.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
168
BN200.1 • A168 • 31469 • 002906 • 153650 • 16842
23 11/16"