JENN-AIR® DETAILED PLANNING DIMENSIONS
36"/30" PYRAMID-STYLE WALL-MOUNT CANOPY HOODS
JXW8536DS – 36" x 245⁄8-425⁄8" x 1911⁄16"
JXW8530DS – 30" x 245⁄8-425⁄8" x 1911⁄16"
PRODUCT DIMENSIONS
MODEL # JXW8536DS JXW8530DS
Width of chimney 133⁄16 33.5 133⁄16 33.5
A
Width of canopy 36 91.4 30 76.2
B
Height of trim 23⁄8 6.1 23⁄8 6.1
C
A
B
FRONT VIEW
E
Height of canopy 5 12.7 5 12.7
D
Overall height with vented
installation (min.-max.)
E
Overall height with non-vented
D
C
(recirculating) installation
(min.-max.)
Depth of chimney 103⁄4 27.3 103⁄4 27.3
F
Depth of canopy 1911⁄16 50.0 1911⁄16 50.0
G
Width of vent collar 61⁄4 15.8 61⁄4 15.8
H
Depth of vent collar 33⁄4 9.5 33⁄4 9.5
I
Width from chimney to edge
J
of canopy
1 of 2
in cm in cm
245⁄8-
383⁄4
285⁄16-
425⁄8
117⁄16 29.0 87⁄16 21.4
62.5-
98.4
71.9-
108.3
245⁄8-
383⁄4
285⁄16-
425⁄8
62.5-
98.4
71.9-
108.3
SIDE VIEW
TOP VIEW
F
G
I
F
H
A
B
J
G
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
8316AdZw1114
JENN-AIR® DETAILED PLANNING DIMENSIONS
36"/30" PYRAMID-STYLE WALL-MOUNT CANOPY HOODS
JXW8536DS – 36" x 245⁄8-425⁄8" x 1911⁄16"
JXW8530DS – 30" x 245⁄8-425⁄8" x 1911⁄16"
OPENING/CLEARANCE DIMENSIONS
2 of 2
FRONT VIEW
H
v
MODEL # JXW8736DS JXW8530DS
in cm in cm
D
v
B
E
C
F
G
Width of entry location for
vent and power supply –
A
10-13
ceiling option (min.-max.)
Width of entry location for
vent and power supply – wall
B
10-13
option (min.-max.)
Width of cabinet opening (min.) 36 91.4 30 76.2
C
25.4-
33.0
25.4-
33.0
10-13
10-13
Minimum height from entry
location to ceiling for vent
and power supply – wall
option (vented installation)
D
Minimum height from entry
location to ceiling for vent and
power supply – wall option
2 5.1 2 5.1
9 22.9 9 22.9
25.4-
33.0
25.4-
33.0
(non-vented installation)
Height from hood to entry
location for vent and power
E
17 43.2 17 43.2
supply – wall option (min.)
Suggested distance from
hood to electric cooking
surface (min.-max.)
F
Suggested distance from
hood to gas cooking surface
(min.-max.)
Height from upper cabinet to
G
countertop (min.)
24-36
27-36
18 45.7 18 45.7
61.0-
91.4
68.6-
91.4
24-36
27-36
61.0-
91.4
68.6-
91.4
Depth of entry location for
vent and power supply –
H
ceiling option
Recommended vent and
v
power supply entry location
91⁄2 24.1 91⁄2 24.1
ELECTRICAL REQUIREMENTS
120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit is required.
VENTING REQUIREMENTS
The hood is factory set for venting through the roof or wall. For non-vented
(recirculating) installation, refer to recirculation kit instructions for further information.
LOCATION REQUIREMENTS
Mounting structure must be able to support 60 lb (27.2 kg).
For vented installation, the chimney can be adjusted for ceilings between
7' 1" (2.16 m) and 9' 2" (2.79 m).
For non-vented (recirculating) installation, the chimney can be adjusted for ceilings
between 7' 1" (2.16 m) and 9' 6" (2.90 m).
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
8316AdZw1114