JennAir JXW8030WS PRODUCT SPECIFICATIONS

PRODUCT MODEL NUMBERS
ELECTRICAL REQUIREMENTS
A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
VENTING METHODS
This canopy hood is factory set for venting through the roof or wall. A 8" (20.0 cm) round vent system is needed for installation (not included).
The hood exhaust opening is 8" (20.0 cm) round. NOTE: Flexible vent is not recommended. Flexible vent creates back
a wall, a 90° elbow is needed.
Rear discharge
A 90° elbow may be installed immediately above the hood.
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood can be used in the non-vented (recirculating) version, fitting a charcoal filter and the deflector. Fumes and vapors are recycled through the top grille.
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
30" (76.2 cm), 36" (91.4 cm) and 42" (106.7 cm) Wall-Mount Canopy Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10274311A
10/14/09
Example vent system
The following example falls within the maximum recommended vent length of 35 ft (10.7 m).
LOCATION REQUIREMENTS
Have a qualified technician install the range hood. It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located behind the left filter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas, such as windows, doors and strong heating vents.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.
PRODUCT DIMENSIONS
*For non-vented (recirculating) installations
**For vented installations
Vent Piece 8" (20.0 cm) Round
45° elbow 2.5 ft (0.8 m)
90° elbow 5.0 ft (1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
1 - 90° elbow 1 - wall cap 8 ft (2.4 m) straight
= 5.0 ft (1.5 m) = 0.0 ft (0.0 m) = 8.0 ft (2.4 m)
Length of system = 13.0 ft (3.9 m)
JXW8030W JXW8036W JXW8042W
Page 1 of 2
Roof Venting
B
Wall Venting
A
Non-vented
(recirculating)
A
B
B
A
90 elbow
2 ft
(0.6 m)
6 ft (1.8 m)
Wall cap
A. Roof cap B. 8" (20.0 cm)
round vent
A. Wall cap B. 8" (20.0 cm)
round vent
A. Deflector B. 8" (20.0 cm)
round vent
10¾" (27.3 cm)
13³⁄₁₆" (33.5 cm)
30" (76.2 cm) 36" (91.4 cm)
42" (106.7 cm)
4⁵⁄₈" (11.7 cm)
7¹⁵⁄₁₆" (20.2 cm)
24"
(60.8 cm)
20½"
(52.0 cm)
5"
(12.7 cm)
19¹¹⁄₁₆" (50.0 cm)
*28⁵⁄₁₆" (71.9 cm) min. 42⁵⁄₈" (108.3 cm) max.
**24⁵⁄₈" (62.5 cm) min. 38¾" (98.4 cm) max.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10274311A
10/14/09
CABINET DIMENSIONS
*For non-vented (recirculating) installations *NOTE: The range hood chimneys are adjustable and designed to meet
varying ceiling or soffit heights depending on the distance “X” between the bottom of the range hood and the cooking surface. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number W10272075 is available from your dealer or an authorized parts distributor. The chimney extension replaces the upper chimney shipped with the range hood.
IMPORTANT:
Minimum distance “X”: 24" (61.0 cm) from electric cooking surface. Minimum distance “X”: 27" (68.6 cm) from gas cooking surfaces. Suggested maximum distance “X”: 36" (91.4 cm)
For vented installations, the chimneys can be adjusted for ceilings between 7' 11" (2.4 m) and 9' 2" (2.8 m).
For non-vented (recirculating) installations, the chimneys can be adjusted for ceilings between 7' 11" (2.4 m) and 9' 6" (2.9 m).
Page 2 of 2
10" (25.4 cm) min. 13" (33.0 cm) max.
9¹⁄₂" (24.1 cm)
2" (5.1 cm) min. 9" (22.9 cm) min.*
10" (25.4 cm) min. 13" (33.0 cm) max.
Side cabinet
bottom of
canopy
to cooking
surface
30" (76.2 cm) 36" (91.4 cm) or 42" (106.7 cm)
"X"
17" (43.2 cm)*
Centerline
Vent and power
supply cable
entry location
Side cabinet
Cooking surface
Loading...