Jenn-Air JXW5036WS, JXW5030WS0, JXW5030WS, JXW5036WS0 Owner’s Manual

JENN-AIR_30"AND 36"(76.2CM AND 91.4 CM)
WALL-MOUNTCANOPY RANGEHOOD
HOTE DECU
MURAL30"ET36"7(6,2CM ET91,4CM)
InstallationInstructionsand Use&Care Guide
For questions about features, operation/performance, parts, accessories, or service in the U.S.A., call:
1-800-JennAir (1-800-536-6247) or visit our website at www.jennair.com.
In Canada, call: 1-800-807-6777, or visit our website at www.jennair.ca.
Au Canada, pour assistance, installation ou service, composez le 1-800-807-6777 ou visitez notre site web a www.jennair.ca.
Table of Contents/Table des matieres ................... 2
IMPORTANT: READ AND SAVE THESE iNSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RI_SIDENTIELLE UNIQUEMENT.
JENN-AIR°
LI3U 1B/W10274303G
TABLEOF CONTENTS
TABLEDESMATIERES
RANGE HOOD SAFETY ................................................................. 3
INSTALLATION REQUIREMENTS ................................................ 5
Tools and Parts ............................................................................ 5
Location Requirements ................................................................ 5
Venting Requirements .................................................................. 6
Electrical Requirements ............................................................... 7
INSTALLATION INSTRUCTIONS .................................................. 7
Prepare Location.......................................................................... 7
Install Range Hood ....................................................................... 8
Connect Vent System .................................................................. 9
Make Electrical Connection ....................................................... 10
Install Vent Covers ..................................................................... 10
Install Filters................................................................................ 11
Complete Installation ................................................................. 11
RANGE HOOD USE ...................................................................... 11
Display ........................................................................................ 11
Light............................................................................................ 12
Tim er........................................................................................... 12
Fan Speed Buttons .................................................................... 12
RANGE HOOD CARE ................................................................... 12
Cleaning ...................................................................................... 12
WIRING DIAGRAM ...................................................................... 14
ASSISTANCE OR SERVICE ......................................................... 15
WAR RANTY .................................................................................. 16
SI_CURITI_ DE LA HOTTE DE CUlSINII_RE ............................... 18
EXIGENCES D'INSTALLATION ................................................... 20
Outillage et pieces ...................................................................... 20
Exigences d'emplacement ......................................................... 20
Exigences concernant I'evacuation ........................................... 21
Specifications electriques .......................................................... 22
INSTRUCTIONS D'INSTALLATION ............................................. 23
Preparation de I'emplacement ................................................... 23
Installation de la hotte ................................................................ 24
Raccordement du circuit d'evacuation ...................................... 24
Raccordement electrique ........................................................... 25
Installation du cache-conduit ..................................................... 26
Installation des filtres .................................................................. 26
Achever I'installation .................................................................. 26
UTILISATION DE LA Ho'n'E ....................................................... 26
Afficheur ..................................................................................... 27
€:clairage ..................................................................................... 27
Minuterie ..................................................................................... 27
Boutons de vitesse du ventilateur .............................................. 27
ENTRETIEN DE LA HOTTE DE CUlSINII_RE ............................. 28
Nettoyage ................................................................................... 28
SCHI_MA DE C.&,BLAGE.............................................................. 29
ASSISTANCE OU SERVICE ......................................................... 30
GARANTIE ..................................................................................... 31
2
RANGE HOOD SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
iMPORTANT SAFETY iNSTRUCTiONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
[] Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
[] Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag,
to the service panel.
[] Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
[] Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety standards such as those published by the National Fire
Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
[] When cutting or drilling into wall or ceiling; do not damage
electrical wiring and other utilities.
[] Ducted fans must always be vented outdoors.
CAUTION: For general ventilating use only. Do not use
to exhaust hazardous or explosive materials and vapors.
CAUTION: To reduce risk of fire and to properly exhaust
air, be sure to duct air outside - do not vent exhaust air into spaces within walls or ceilings, attics or into crawl spaces, or garages.
WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
WARNING: TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE: [] Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
[] Always turn hood ON when cooking at high heat or when
flambeing food (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flamb6).
[] Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
[] Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING: TO REDUCE THE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: a
[] SMOTHER FLAMES with a close fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
[] NEVER PICK UP A FLAMING PAN -you may be burned. [] DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
[] Use an extinguisher ONLY if:
- You know you have a class ABC extinguisher, and you already know how to operate it.
- The fire is small and contained in the area where it started.
- The fire department is being called.
- You can fight the fire with your back to an exit.
aBased on "Kitchen Fire Safety Tips" published by NFPA. [] WARNING: To reduce the risk of fire or electrical shock,
do not use this fan with any solid-state speed control device.
READ AND SAVE THESE iNSTRUCTiONS
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed
here.
Tools needed
Level
Drill with 11¼'' (3.0 cm), 3/8"(9.5 mm), 7/64"(2.75 mm) and 1/8"(3.0 mm) drill bits
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Parts needed
Home power supply cable
1/2"(12.7 mm) UL listed or CSA approved strain relief
3 UL listed wire connectors
For vented installations, you will also need:
1 wall or roof cap
Metal vent system
For non-vented (recirculating) installations, you will also need:
Recirculation Kit Part Number W10272064 for non-vented (recirculating) installations only. See "Assistance or Service"
section to order.
IMPORTANT: Observe all governing codes and ordinances. Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located behind the left filter on the rear wall of the vent
hood. Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents. Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance. Grounded electrical outlet is required. See "Electrical
Requirements" section.
The canopy hood is factory set for venting through the roof or
wall. For non-vented (recirculating) Installation see "For Non- vented (recirculating) Installations" in "Connect Vent System"
section. Recirculation Kit Part Number W10272064 is available from your dealer or an authorized parts distributor.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
Parts supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and light bulbs installed
2 glass mounting brackets
Vent transition with back draft dampers installed
Blower support bracket
Glass mantle
Vent cover support bracket (3 pieces)
Mounting template
2-piece vent cover
2 - 2.9 x 6.5 mm screws
8-4x8mmscrews
6- 5 x 45 mm mounting screws
2- 8 x 40 mm wall anchors
4- 10 x 50 mm wall anchors
35" (88.9 cm) mh
"60 3/4" (154.3 crn)
56 s,46"(143.0 crn)
(50 cm)
*For non-vented (recirculating) installations
30" - 36"
(78.2 crn - 91.4 crn)
Installation Dimensions
13%"
*8" (20.3 cm) rain.
11%"
(36 cm) vent and power
side I side
cabinet _;;;;;;;;i;._ ......::i.;;;;; ,_.;_i_ cabinet
2" (5.1 cm) rain.
26 7/8"
(68cm)
supply cable entry
location
, i<ji:i2o
"X" bottom of canopy to
cooking surface
centerline cooking surface
*For non-vented (recirculating) installations
IMPORTANT:
Minimum distance "X": 24" (61.0 cm) from electric cooking surface.
Minimum distance "X": 27" (68.6 cm) from gas cooking surfaces.
Suggested maximum distance "X": 36" (91.4 cm)
For vented installations, the chimneys can be adjusted for ceilings between 8' (2.44 m) and 10' 2" (3.1 m).
For non-vented (recirculating) installations, the chimneys can be adjusted for ceilings between 8' (2.44 m) and 10' 6" (3.2 m).
*NOTE: The range hood chimneys are adjustable and designed to
meet varying ceiling or soffit heights depending on the distance
"X" between the bottom of the range hood and the cooking
surface. For higher ceilings, a Stainless Steel Chimney Extension
Kit Part Number W10272071 is available from your dealer or an authorized parts distributor. The chimney extension replaces the upper chimney shipped with the range hood.
The vent system must have a damper. If the roof or wall cap has a damper, do not use the damper supplied with the range
hood.
Use caulking to seal exterior wall or roof opening around the cap.
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air flow and athermal break should be installed to minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your
area.
Venting Methods
This canopy hood is factory set for venting through the roof or
wall.
A 8" (20.0 cm) round vent system is needed for installation (not
included). The hood exhaust opening is 8" (20.0 cm) round. NOTE: Flexible vent is not recommended. Flexible vent creates
back pressure and air turbulence that greatly reduce performance.
Vent system can terminate either through the roof or wall. To vent
through a wall, a 90° elbow is needed.
Rear discharge
A 90° elbow may be installed immediately above the hood.
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood can be used in the non-vented (recirculating) version, fitting a charcoal filter and the deflector. Fumes and vapors are recycled through the top grille.
Roof Venting Wall Venting Non-vented
(recirculating)
Vent system must terminate to the outdoors, except for non- vented (recirculating) installations.
Do not terminate the vent system in an attic or other enclosed area.
Do not use 4" (10.2 cm) laundry-type wall cap.
Use metal vent only. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
6
A
A
B
A. Roof cap A. Wall cap A. Deflector
B. 8" (20.0 cm) B. 8" (20.0 cm) B. 8" (20.0 cm)
round vent round vent round vent
NOTE: Wall venting may not be possible for all installations.
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
Vent Piece 8" (20.0 cm) Round
45° elbow 2.5 ft
(0.8 m)
90° elbow 5.0 ft
(1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
Example vent system
90° e,bow _,_ 6tt (1._m)-_._l Wall cap
If the house has aluminum wiring, follow the procedure below:
1. Connect a section of solid copper wire to the pigtail leads.
2. Connect the aluminum wiring to the added section of copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices. Wire sizes and connections must conform with the rating of
the appliance as specified on the model/serial rating plate. The model/serial plate is located behind the filter on the rear wall of the range hood.
Wire sizes must conform to the requirements of the National Electrical Code, ANSl/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and
ordinances.
INSTALLATIONINSTRUCTIONS
2fl
(0.6m)
The following example falls within the maximum recommended vent length of 35 ft (10.7 m).
1 - 90 ° elbow = 5.0 ft (1.5 m)
1 - wall cap = 0.0 ft (0.0 m) 8 ft (2.4 m) straight = 8.0 ft (2.4 m)
Length of system = 13.0 ft (3.9 m)
E®c 'ccl <i!®quss> :Y.............@n'B
Observe all governing codes and ordinances. Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSl/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances. If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
It is recommended that the vent system be installed before hood is installed.
Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.
Check your ceiling height and the hood height maximum before you select your hood.
1. Disconnect power.
2. Determine which venting method to use: roof, wall, or non- vented.
3. Select a flat surface for assembling the range hood. Place covering over that surface.
Excessive Weight Hazard
Use two or more people to move and install range hood.
Failure to do so can result in back or other injury.
4. Using 2 or more people, lift range hood onto covered surface.
Range Hood Mounting Screws Installation
5. Determine and mark the centerline on the wall where the canopy hood will be installed.
6. Select a mounting height between a minimum of 24" (61.0 cm) for an electric cooking surface, a minimum of
27" (68.6 cm) for a gas cooking surface, and a suggested maximum of 36" (91.4 cm) above the range to the bottom of
the hood and mark a reference line on the wall.
7. Tape template in place, aligning the template centerline and bottom of template with hood bottom line and with the
centerline marked on the wall.
F
_A
,>
'<i ill...........................
C
,4.Centerline B. Lower support bracket
C. 5 x 45 mm screws
D. Mounting height reference
E. Fastener locations
F Waft
8.
Place the support bracket on the template aligning it with the traced rectangle. Mark centers of 4 fastener locations through the template to the wall, 2 for support bracket, 2 for bottom rear of blower housing.
IMPORTANT: All screws must be installed into wood. Remove the template.
9.
Drill %4" (2.75 mm) pilot holes at all locations where screws are being installed into wood.
NOTE: When mounting into a concrete wall, drill 5/le" (8 mm) pilot holes and use anchors supplied.
10. Attach the support bracket to the wall using 2 - 5 x 45 mm screws at the top 2 drilled hole locations.
2.
Install vent cover bracket to wall about %" (3.0 mm) away from the ceiling. Use 2 - 5 x 45 mm screws with 8 x 40 mm drywall anchors supplied.
i
' B
A
m
A. Vent cover bracket B. Centerline on wall
Complete Preparation
1. Determine and make all necessary cuts in the wall for the vent system. Install the vent system before installing the hood. See
"Venting Requirements" section.
2. Determine the required height for the home power supply cable and drill a 11¼'' (3.2 cm) hole at this location.
3. Run wire through the home power supply cable according to the National Electrical Code or CSA Standards and local
codes and ordinances. There must be enough 1/2"conduit and wires from the fused disconnect (or circuit breaker) box
to make the connection in the hood's electrical terminal box. NOTE: Do not reconnect power until installation is complete.
4. Use caulk to seal all openings.
H
1.
Using 2 or more people, hang blower housing on lower support bracket using the 2 mounting hooks on the rear of the blower housing.
A. Support bracket
B. 5 x 45 mm screws
C. Centerline on wall
Vent Cover Bracket Assembly and Installation
1. Assemble the 3 pieces of the vent cover bracket using 4 - 4 x 8 mm screws provided. The assembled bracket should be sized to dimension "X" to fit inside the upper vent cover.
C
A. Vent cover bracket assembly B. Upper vent cover
C. 4 x 8 mm screws
A
A. Lower support bracket B. Mounting hooks C. Adjust in and out
(for leveling front to back).
D. Adjust up and down
(for leveling left to right).
E. Blower housing
2.
Level the blower housing with leveling screws in mounting hooks, using a level across bottom of blower housing.
E
8
3. Remove the metal grease filter and secure the blower housing with two screws in the bottom holes located in the
rear of the blower.
A
B
A. Rearof blower housing
B.Bottom 5 x 45 mm screw holes
Glass Mantle Installation
1. Place the glass mantle onto the hood.
2. Connect glass mantle to range hood with the 2 glass mounting brackets and four 4 x 8 mm screws.
Vented Installation Only
1. Fit vent system over transition piece.
2. Seal connection with clamps.
3. Check that backdraft dampers work properly.
For Non-vented (Recirculating) Installation:
1. Assemble the 3 parts of the deflector with 2 - 3.5 x 9.5 mm screws provided. The assembled deflector should be sized to
fit the width of the vent cover bracket installed earlier.
C
B
A. Vent cover bracket width
B.Deflector
C. 3.5 x 9.5 mm screws
A. Glass mantle B. Glass mounting bracket
C. 4 x 8 mm screws
2.
Connect the deflector to the vent cover bracket using 4 - 3.5 x 9.5 mm screws provided.
..........A
....s"
I I
I
B
A. Vent cover bracket
B.3.5 x 9.5 mm screws
3. Measure the length of 8" (20.3 cm) round vent (not provided) needed to connect the transition to the deflector.
NOTE: Vent should fit inside deflector a minimum of 1" (2.5 cm)
4. Install vent between the transition and the deflector.
5. Seal connection with clamps.
6. Check that backdraft dampers work properly.
Mc,, Eecff Connect on
Electrical Shock Hazard
Disconnect power before servicing. Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1=
Disconnect power•
2.
Remove terminal box cover•
3.
Remove the knockout in the terminal box cover and install a UL listed or CSA approved 1/2"strain relief•
4=
Run 3 wires, black, white and green (14AWG), in 1/2"conduit from service panel to terminal box. Use caulking to seal opening•
g .........................
A .......
Electrical Shock Hazard
Electrically ground blower. Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power supply to yellow-green ground wire (E)in terminal box using UL listed
wire connectors•
8. Tighten strain relief screw•
9. Install terminal box cover•
10. Check that all light bulbs are secure in their sockets•
11. Reconnect power•
n
Push lower cover down onto hood and lift upper cover to ceiling and install with two 2.9 x 6.5 mm screws.
NOTE: For vented installations the upper vent cover may be reversed to hide slots.
C ............_!_--
D
E c
A. UL listed or CSA approved strain refief B. Home power supply cable
C• Terminal box D. Black wires
E• Green (or bare) wire connected to yellow-green wire F. White wires
5. Use UL listed wire connectors and connect black wires (D) together•
6. Use UL listed wire connectors and connect white wires (F) together•
,_ ....................................................S
A. Vent cover bracket B. Upper vent cover
C. Lower vent cover D. 2.9 x 6.5 mm screws
10