JENN-AIR® DETAILED PLANNING DIMENSIONSJENN-AIR® DETAILED PLANNING DIMENSIONS
36"/30" PRO-STYLE™ LOW PROFILE UNDER CABINET HOODS
JXU9136WP – 36" x 101⁄2" x 23"
JXU9130WP – 30" x 101⁄2" x 23"
PRODUCT DIMENSIONS
MODEL # JXU9136WP JXU9130WP
B
FRONT VIEW
F
D
E
C
G
Overall width 36 91.4 30 76.2
A
Height without trim 8 20.3 8 20.3
B
Height of trim 2 5.1 2 5.1
C
Height without controls 10 25.4 10 25.4
D
Height with controls 101⁄2 26.7 101⁄2 26.7
E
Height of optional duct cover 12 30.5 12 30.5
F
Depth of optional duct cover 12 30.5 12 30.5
G
Depth of hood 23 58.4 23 58.4
H
Width of duct opening 10 25.4 10 25.4
I
1 of 2
in cm in cm
D
H
SIDE VIEW
(shown with optional duct cover)
I
A
TOP VIEW
H
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved. 8562DdZw815
JENN-AIR® DETAILED PLANNING DIMENSIONSJENN-AIR® DETAILED PLANNING DIMENSIONS
36"/30" PRO-STYLE™ LOW PROFILE UNDER CABINET HOODS
JXU9136WP – 36" x 101⁄2" x 23"
JXU9130WP – 30" x 101⁄2" x 23"
OPENING/CLEARANCE DIMENSIONSOPENING/CLEARANCE DIMENSIONS
H
e
v
C
D
A
TOP VIEW
B
v
I
A
G
2 of 2
J
Centerline
E
Centerline
F
ELECTRICAL REQUIREMENTS
120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit
is required.
VENTING REQUIREMENTS
The hood is factory set for venting through the roof or wall.
Do not terminate the vent in an attic or other enclosed area.
FRONT VIEW
MODEL # JXU9136WP JXU9130WP
Width of vent cutout 101⁄2 26.7 101⁄2 26.7
A
Width of cabinet opening (min.) 36 91.4 30 76.2
B
Height from vent cutout to upper cabinet – wall option
C
Height of vent cutout – wall option 31⁄2 8.9 31⁄2 8.9
D
Suggested distance from hood to cooking surface (min.-max.) 30-36 76.2-91.4 30-36 76.2-91.4
E
Height from upper cabinet to countertop (min.) 18 45.7 18 45.7
F
Distance from center of electrical access to center of hood 121⁄4 31.0 121⁄4 31.0
G
Distance from center of electrical access to wall 77⁄8 20.0 77⁄8 20.0
H
Depth from vent cutout to wall – ceiling option
I
Depth of vent cutout – ceiling option 31⁄2 8.9 31⁄2 8.9
J
e
Recommended electrical access location 11⁄4 dia. 3.2 dia. 11⁄4 dia. 3.2 dia.
v
Recommended vent location
in cm in cm
3
⁄8 1.0
3
⁄8 1.0
3
⁄8 1.0
3
⁄8 1.0
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved. 8562DdZw815