Jenn-Air JXI8236WS, JXI8042WS, JXI5042WS, JXI8036WS, JXI5036WS User Manual

JENN-AIR® 36", AND 42" (91.4 CM, AND 106.7 CM)
ISLAND-MOUNT CANOPY RANGE HOOD
HOTTE DE CUISINIÈRE JENN-AIR
®
EN ÎLOT DE
36" ET 42" (91,4 CM ET 106,7 CM)
LI3U2C/W10274308H
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. FOR RESIDENTIAL USE ONLY. IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS. POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
For questions about features, operation/performance, parts, accessories, or service in the U.S.A., call:
Instructions d’installation et Guide d’utilisation et d’entretien
Au Canada, pour des questions à propos des caractéristiques, du fonctionnement/rendement, des pièces, accessoires ou service,
composer le 1-800-JENNAIR (1-800-536-6247) ou visiter notre site web à www.jennair.ca.
1-800-JENNAIR (1-800-536-6247) or visit our website at www.jennair.com.
In Canada, call: 1-800-JENNAIR (1-800-536-6247), or visit our website at www.jennair.ca.
Table of Contents/Table des matières................................... 2

TABLE OF CONTENTS

You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
State of California Proposition 65 Warnings: WARNING: This product contains one or more chemicals known to the State of California to cause cancer. WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
RANGE HOOD SAFETY .................................................................2
INSTALLATION REQUIREMENTS................................................3
Tools and Parts ............................................................................3
Location Requirements................................................................4
Venting Requirements..................................................................5
Electrical Requirements ...............................................................6
INSTALLATION INSTRUCTIONS..................................................6
Prepare Location..........................................................................6
Install Range Hood.......................................................................7
Make Electrical Connection .........................................................8
Install Duct Covers.......................................................................9
Install Filters................................................................................10
Complete Installation .................................................................10
RANGE HOOD USE......................................................................11
Display........................................................................................11
Light............................................................................................11
Timer...........................................................................................11
Fan Speed Buttons ....................................................................11
RANGE HOOD CARE...................................................................12
Cleaning......................................................................................12
WIRING DIAGRAM ......................................................................13
ASSISTANCE OR SERVICE.........................................................14
In the U.S.A. ...............................................................................14
In Canada ...................................................................................14
Accessories................................................................................14
WARRANTY ..................................................................................15

TABLE DES MATIÈRES

SÉCURITÉ DE LA HOTTE DE CUISINIÈRE................................16
EXIGENCES D'INSTALLATION...................................................18
Outils et pièces...........................................................................18
Exigences d’emplacement.........................................................18
Exigences concernant l’évacuation ...........................................19
Spécifications électriques ..........................................................20
INSTRUCTIONS D'INSTALLATION.............................................21
Préparation de l'emplacement...................................................21
Installation de la hotte ................................................................22
Raccordement électrique...........................................................23
Installation des cache-conduits .................................................24
Installation des filtres..................................................................25
Achever l’installation ..................................................................25
UTILISATION DE LA HOTTE .......................................................26
Afficheur .....................................................................................26
Éclairage.....................................................................................26
Minuterie.....................................................................................26
Boutons de vitesse du ventilateur..............................................26
ENTRETIEN DE LA HOTTE DE CUISINIÈRE .............................27
Nettoyage ...................................................................................27
SCHÉMA DE CÂBLAGE ..............................................................28
ASSISTANCE OU SERVICE.........................................................29
Au Canada..................................................................................29
Accessoires....................................................................................29
GARANTIE.....................................................................................30

RANGE HOOD SAFETY

2
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
Do not operate any fan with a damaged cord or plug.
Discard fan or return to an authorized service facility for examination and/or repair.
Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling; do not damage
electrical wiring and other utilities.
Ducted fans must always be vented outdoors. CAUTION: For general ventilating use only. Do not use
to exhaust hazardous or explosive materials and vapors.
CAUTION: To reduce risk of fire and to properly exhaust
air, be sure to duct air outside - do not vent exhaust air into spaces within walls or ceilings, attics or into crawl spaces, or garages.
WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
WARNING: TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE:
Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
Always turn hood ON when cooking at high heat or when
flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING: TO REDUCE THE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a
SMOTHER FLAMES with a close fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
NEVER PICK UP A FLAMING PAN - you may be burned.
DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
Use an extinguisher ONLY if:
– You know you have a class ABC extinguisher, and you
already know how to operate it.
– The fire is small and contained in the area where it
started. – The fire department is being called. – You can fight the fire with your back to an exit.
a
Based on "Kitchen Fire Safety Tips" published by NFPA.
WARNING: To reduce the risk of fire or electrical shock,
do not use this fan with any solid-state speed control device.
†®TORX, T10 and T20 are registered trademarks of Acument Intellectual Properties, LLC.
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools and Parts

Tools needed
Level
Drill with 1¼" (3.0 cm), ³⁄₈" (9.5 mm), ⁷⁄₆₄" (2.75 mm) and
¹⁄₈" (3.0 mm) drill bits
Pilot hole drill bits (determined by chimney support
attachment method)
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound

INSTALLATION REQUIREMENTS

Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
T10
T20
Parts needed
Home power supply cable
2 - ½" (12.7 mm) UL listed or CSA approved strain reliefs
3 UL listed wire connectors
®
Tor x®† driver
®
Tor x® driver
For vented installations, you will also need:
1 wall or roof cap
Metal vent system
3
For non-vented (recirculating) installations, you will also need:
36" - 42" (91.4 cm to 106.7 cm)
25¼" (64.0 cm)
13³⁄₈" (33.8 cm)
15" (38.0 cm)
*35³⁄₁₆" (99.5 cm) min. 53³⁄₁₆" (152.8 cm) max. **35³⁄₁₆" (107.0 cm) min. 56³⁄₁₆" (158.0 cm) max.
1½" (4.0 cm)
A
D
B*
C
Recirculation Kit Part Number W10272065 for non-vented
(recirculating) installations only. See “Assistance or Service” section to order.
Parts supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and light bulbs
installed
8 vertical supports
2 glass mounting brackets
Glass mantle
Mounting template
Upper horizontal support
Horizontal support
60 4.2 x 8 mm screws
4 - 3.5 x 9.5 mm glass mantle mounting screws
4 - 5 x 45 mm screws
4 - 3.5 x 6.5 mm screws
2 - 2.9 x 3 mm screws
2 - Upper vent covers
2 - Lower vent covers
4 - Plastic clips
Product Dimensions
*Vented installations only
**Non-vented (recirculating) installations only
IMPORTANT: Observe all governing codes and ordinances. Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located behind the left filter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas, such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical Requirements” section.
Because of the size and weight of this island hood, the chimney support must be securely attached to the ceiling.
For plaster or drywall ceilings, the chimney support must be
attached to joists. If this is not possible, you must build a support structure behind the plaster or drywall. The support structure must be able to support 80 lbs (36.6 kg).
This range hood is recommended for use with cooktops with
a maximum total rating of 60,000 BTUs or less.
The range hood is factory set for venting through the roof or wall. For non-vented (recirculating) Installation see “Non-vented
(recirculating) Installations” in “Install Range Hood” section. Recirculation Kit Part Number W10272065 is available from your dealer or an authorized parts distributor.
All openings in ceiling and wall where range hood will be installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.

Location Requirements

Installation Clearances
A. Ceiling height B. Hood height from ceiling to bottom of the
range hood: A-C-D=B
C. Hood height: 24" (61.0 cm) min. from
electric cooking surface, 30" (76.2 cm) min. from gas cooking surface, suggested 36" (91.4 cm) max
D. Countertop height
IMPORTANT:
Minimum distance “C”: 24" (61.0 cm) from electric cooking surface. Minimum distance “C”: 27" (68.6 cm) from gas cooking surface. Suggested maximum distance “C”: 36" (91.4 cm)
4
The chimneys can be adjusted for different ceiling heights. See
A
B
A
B
the following chart.
Vented Installations
Min. ceiling height Max. ceiling height
Electric cooking
7' 9" (2.36 m) 9' 10" (3.0 m)
surface Gas cooking
8' (2.44 m) 9' 10" (3.0 m)
surface
Non-Vented (Recirculating) Installations
Min. ceiling height Max. ceiling height
Electric cooking
7' 9" (2.36 m) 10' 4" (3.15 m)
surface Gas cooking
8' (2.44 m) 10' 4" (3.15 m)
surface
*NOTE: The range hood chimneys are adjustable and designed
to meet varying ceiling or soffit heights depending on the distance “C” between the bottom of the range hood and the cooking surface. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number W10635231 is available from your dealer or an authorized parts distributor. The chimney extension replaces the upper chimney shipped with the range hood.

Venting Requirements

(vented models only)
Vent system must terminate to the outdoors, except for non-
vented (recirculating) installations.
Do not terminate the vent system in an attic or other enclosed
area.
Do not use 4" (10.2 cm) laundry-type wall cap.
Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the
cap.
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break.
The break should be as close as possible to where the vent system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.
Venting Methods
This range hood is factory set for venting through the roof. A 8" (20.3 cm) round vent system is needed for installation (not
included). The hood exhaust opening is 8" (20.3 cm) round. NOTE: Flexible vent is not recommended. Flexible vent creates
back pressure and air turbulence that greatly reduce performance.
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood can be used in the non-vented (recirculating) version, using a Recirculation Kit (which includes charcoal filters and a deflector). To order, see the “Assistance or Service” section.
Non-vented (recirculating) Roof Venting
A. Deflector B. 8" (20.3 cm) round vent
A. Roof cap B. 8" (20.3 cm) round vent
NOTE: Wall venting can be an option for 2-story homes.
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
Vent piece 8" (20.3 cm) round
45° elbow 2.5 ft
90° elbow 5.0 ft
Maximum equivalent vent length is 35 ft (10.7 m).
(0.8 m)
(1.5 m)
5
Example vent system
90 elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
WARNING
Excessive Weight Hazard
Use two or more people to move and install range hood.
Failure to do so can result in back or other injury.
The following example falls within the maximum recommended vent length of 35 ft (10.7 m).
1 - 90° elbow = 5.0 ft (1.5 m) 1 - wall cap = 0.0 ft (0.0 m) 8 ft (2.4 m) straight = 8.0 ft (2.4 m)
Length of system = 13.0 ft (3.9 m)

Electrical Requirements

Observe all governing codes and ordinances. Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is
required.
If the house has aluminum wiring, follow the procedure
below:
1. Connect a section of solid copper wire to the pigtail
leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of
the appliance as specified on the model/serial rating plate. The model/serial plate is located behind the filter on the rear wall of the range hood.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

INSTALLATION INSTRUCTIONS

It is recommended that the vent system be installed before
the range hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling for exhaust vent.
Range hood is to be installed 24" (61.0 cm) min. for electric
cooking surfaces, 27" (68.6 cm) min. for gas cooking surfaces, to a suggested maximum of 36" (91.4 cm) above the cooking surface.
Check your ceiling height and the range hood height
maximum before you select your hood.
1. Disconnect power.
2. Determine which venting method to use: roof or non-vented.
3. Select a flat surface for assembling the range hood. Place
covering over that surface.
4. Using 2 or more people, lift range hood onto covered surface.
6

Prepare Location

Range Hood Mounting Screws Installation
1. Determine and mark the centerline on the ceiling where the
range hood will be installed, considering the requirements for ceiling support structures. See the “Location Requirements” section. Make sure the range hood is centered over the cooking surface.
2. Tape template in place on the ceiling at the marked
centerline. The line for the front of the range hood should be parallel to the front of the cooktop.
3. Use a pencil to mark the mounting screws, wire access and
duct hole locations on the ceiling. NOTE: Mounting hole locations should be into a ceiling
support structure capable of holding 80 lbs (36.6 kg). Remove the template.
4. Drill 4 - ³⁄₁₆" (4.8 mm) pilot holes for mounting the upper
horizontal support.
Complete Preparation
A
B
A
A
C
C
B
A
A
A
A
A
B
1. Determine the required location for the home power supply
cable and drill a ½" (1.3 cm) diameter hole for wire access.
2. Run ½" (1.3 cm) conduit and wires or home power supply
cable according to the National Electrical Code or CSA Standards and local codes and ordinances. There must be enough ½" conduit and wires or home power supply cable from the fused disconnect (or circuit breaker) box to make the connection in the hood’s electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
3. For vented installations only: Using a jigsaw or keyhole
saw, cut a 8½" (21.6 cm) diameter hole for the vent duct.
4.
Attach the upper horizontal support bracket with 4 - 5 x 45 mm wood screws.
NOTE: Upper horizontal support screws must be into a ceiling support structure capable of holding 80 lbs (36.6 kg).
3. Attach a second set of vertical supports (A) and set the
vertical height (B). See “Installation Clearances” in the “Location Requirements” section to help determine the desired dimension for vertical height “B.”
®
Secure with 16 - 4.2 x 8 mm T20
A. Vertical supports B. Vertical height
screws.
4. Using 2 people, place the glass mantle onto the range hood.
A. Upper horizontal support

Install Range Hood

1. Position the 4 vertical supports (A) with the notches at the
bottom and attach to the range hood using 16 - 4.2 x 8 mm screws.
2. Attach the horizontal support (B) using 8 - 4.2 x 8 mm screws.
A. Vertical supports B. Horizontal support C. Notched end
A. Glass mantle
5. Connect glass mantle to range hood with the 2 glass
mounting brackets and 4 - 3.5 x 9.5 mm screws.
A. Glass mounting bracket B. 3.5 x 9.5 mm screws
7
Range Hood Installation
A
B
B
A
WARNING
Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.
B
A
C
D
E
F
WARNING
Electrical Shock Hazard Electrically ground blower. Connect ground wire to green and yellow ground wire
in terminal box. Failure to do so can result in death or electrical shock.
1. Using 2 or more people, lift the range hood assembly and
attach it by snapping the vertical supports to the spring clips in the upper horizontal support bracket that is mounted to the ceiling.
NOTE: The range hood assembly must be held in place while you are installing the screws in the next step.
2. Install 16 - 4.2 x 8 mm screws and tighten to secure.
A. Mounting screws
Connect Vent System
1. Install vent system.
2. Push duct over the exhaust outlet. Seal all connections with
vent clamps.
3. Use caulk to seal all openings.

Make Electrical Connection

1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and install a
UL listed or CSA approved ¹⁄₂"strain relief.
4.
Run 3 wires, black, white and green (14AWG), in service panel to terminal box. Use caulking to seal opening.
¹⁄₂
" conduit from
Non-Vented (recirculating) Installation
1. Attach the air deflector to the upper horizontal support using
4 mounting screws.
A. Deflector
B. Mounting screws
2. Measure the length of 8" (20.3 cm) duct (not included)
needed to connect the transition to the deflector. NOTE: Vent should fit up inside the deflector 1" (2.5 cm)
minimum.
3. Install vent between the transition and the deflector. NOTE: To make vent installation easier, temporarily remove
the deflector from the chimney support bracket and replace after vent section is in place.
4. Seal all connections with vent clamps.
A. UL listed or CSA approved strain relief B. Home power supply cable C. Terminal box D. Black wires E. Green (or bare) wire connected to yellow-green wire
F. Wh it e wi re s
5. Use UL listed wire connectors and connect black wires (D)
together.
6. Use UL listed wire connectors and connect white wires (F)
together.
8
7. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (E) in terminal box using UL listed wire connectors.
8. Tighten strain relief screw.
A
A
B
C
C
A
B
C
B
C
A
D
B
A
A
B
D
C
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.

Install Duct Covers

NOTE: Remove the film from the duct covers.
1. Assemble the upper duct covers together and install the duct
covers around the support frame. The larger hole in the flanges of the upper duct cover must be outside the smaller hole in the mating flange of the other upper duct cover.
2. Secure the upper duct covers together with two 3.5 x 6.5 mm screws at the top and two 2.9 x 3 mm screws at the bottom. Install 1 screw on each side at the top and bottom of the assembled duct covers.
3. Slide the upper duct covers up the frame to the ceiling and
secure to the upper horizontal support with 2 - 3.5 x 6.5 mm screws.
A. 3.5 x 6.5 mm screw B. Slotted holes (2)
C. Upper duct covers D. Ceiling
4. Place the long end of the plastic clips (2) into the bottom of
the front lower duct cover.
A. 3.5 x 6.5 mm Screws (2) B. Assembly holes (larger hole outside of
smaller hole on both sides)
C. 2.9 x 3 mm screws (2)
NOTE: For non-vented (recirculating) installation, the slotted holes in the upper duct covers will be visible when assembled. For vented installations, the slotted holes will be hidden down inside the lower duct covers.
5. Install the lower duct cover (front) to the range hood canopy.
Spread the lower duct cover opening slightly and position it over the upper duct cover. Set the lower duct cover in place. Position so the flanges of the lower duct cover set into the flanges of the upper duct covers.
A. Lower duct cover - (front) B. Plastic clips (2) (long end for front placement)
A. Range hood canopy B. Plastic clips
C. Lower duct covers D. Upper duct covers
A. Top toward ceiling B. Slots installed up for non-vented installations C. Slots installed down for vented installations
9
6. Install the lower duct cover (rear) to the range hood canopy.
A
B
C
D
A
B
Spread the lower duct cover opening slightly and position it over the upper duct cover. Set the lower duct cover in place. Position so the flanges of the lower duct cover set into the flanges of the upper duct cover. Make sure the front and rear lower duct covers mate properly.
NOTE:
When assembling the rear lower duct cover to the front lower duct cover, the flange (both sides) must be placed over the plastic clip to secure the lower duct covers together at the bottom.
A. Lower duct cover (rear) B. Plastic clips
C. Lower duct covers D. Upper duct covers
7. Secure the lower duct covers together at the top using 2
plastic clips. Use one plastic clip on each side.
8. Secure the lower duct cover to the range hood canopy using
4 - 4.2 x 8 mm screws.

Install Filters

For non-vented (recirculating installations):
1. Install optional charcoal filter, wrapping it around the grease
filter.
2. Place the charcoal filter mat around the grease filter and fix it
in place by using the cap lock springs provided.
3. Position the upper cap and fix it in place using the cap lock
spring provided.
A. Charcoal filter mat B. Grease filter C. Charcoal filter side
lock springs
D. Upper cap
E. Cap lock spring F. Grease filter support
For all installations:
A. Plastic clips (2)
B. Lower duct covers top clip area
4. Install the grease filter. See “Range Hood Care” section.

Complete Installation

Check the operation of the range hood blower and light. See the “Range Hood Use” section.
If range hood does not operate, check to see whether a circuit breaker has tripped or a household fuse has blown.
NOTE: To get the most efficient use from your new range hood, read the “Range Hood Use” section.