Jenn-Air JIE4115GS User Manual

JENN-AIR® DETAILED PLANNING DIMENSIONS
A
B
A
B
C
D*
G
F
E
15" MODULAR INDUCTION WOK
JIE4115GS – 15" x 57⁄8" x 21"
PRODUCT DIMENSIONS
1 of 2
TOP VIEW
E
A
MODEL # JIE4115GS
in cm
Overall width 15 38.1
A
Overall depth 21 53.3
B
Center of cooktop to center of
C
electrical conduit
Width of cooktop base 141⁄4 36.2
B
G
D*
Height of cooktop base 419⁄32 11.7
E
Height from electrical conduit to
F
underside of cooktop
Thickness of cooktop surface
G
Depth of cooktop base 205⁄16 51.6
H
* Measured from tab to tab. Tabs should not be bent during installation.
515⁄32 13.9
57⁄8 14.9
1
8 0.3
F
C
D*
FRONT VIEW
SIDE VIEW
B
H
IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation. All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
9000AdZw617
JENN-AIR® DETAILED PLANNING DIMENSIONS
D* G
E
A
B
B
e
F
Side
Cabinet
C
G
Side
Cabinet
15" MODULAR INDUCTION WOK
JIE4115GS – 15" x 57⁄8" x 21"
OPENING/CLEARANCE DIMENSIONS
MODEL # JIE4115GS
Width of combustible area above
A
cooking surface (min.) Width from cooktop to fixed wall or
B
other combustible material (min.) Width from center line of cutout to
C
junction box Height to bottom of uncovered wood or
D*
metal cabinet above cooking surface (min.) Height to bottom of uncovered wood or
E
metal cabinet (min.)
Height to top edge of junction box 12 30.5
F
Depth of upper cabinet 13 33.0
G
Depth from cutout to wall (min.) 25⁄16 5.9
H
Width of cutout (recommended) 143⁄8 36.5
I
Depth of cutout (recommended) 207⁄16 51.9
J
Depth from cutout to front of countertop 25⁄16 5.9
K
e
Recommended electrical access location
* Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal
cabinet is covered by not less than 1⁄4" (0.6 cm) flame retardant millboard covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
If installing a hood or microwave hood combination above the cooktop,
follow the hood or microwave hood combination instructions for dimensional clearances above the cooking surface.
B
FRONT VIEW
D*
A
E
B
F
e
C
2 of 2
in cm
15 38.1
6 15. 2
9 23.0
30 76.2
18 45.7
Side
Cabinet
G
ELECTRICAL REQUIREMENTS
A 240 Volt, 60 Hz, AC only 20-amp fused, grounded electrical circuit is required. A time-delayed fuse or dedicated circuit is recommended. Electrical connection should not be on a GFI circuit.
LOCATION REQUIREMENTS
• Allow 2" (5.1 cm) minimum clearance from bottom of cooktop base to any obstruction below it.
• To ensure cooktop base clearance, cabinet side walls need to be wider than the cutout.
• If cabinet has a drawer, allow a 51⁄2" (14.0 cm) minimum clearance between countertop and top of drawer.
I
H
J
K
TOP VIEWSIDE VIEW
IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation. All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
9000AdZw617
Loading...