www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
Slide In Gas Ranges:
JGS8850ADS, JGS8850ADB, JGS8850ADQ and
JGS8850ADW
29 7/8"
26 3/16"
• Dimensions (Actual Size) •
Width:
29 7/8"
Depth:
26 3/16"
Height:
Door swing:
Height at full leg adjustment:
Height at 0" leg adjustment:
• Additional Information •
• Units depth including door handle is 28 3/8".
• Can be installed with the back against (0") a vertical
combustible wall if equipped with optional backguard
kit, and the sides below the cooktop surface against
(0") combustible base cabinets.
• Electrical requirements: 120/240 or
120/208VAC,60Hz. 40 or 50 amp grounded circuit
protection is required.
• Proper operation requires use of range hood.
• Cabinetry over cooktop : 30" minimum clearance
between the top of the cooking surface and the bottom
of an unprotected wood or metal cabinet. 24" minimum
when bottom of wood or metal cabinet is protected by
not less than 1/4" flame retardant millboard covered
with not less than no. 28 MSG sheet steel, 0.015"
stainless steel, 0.024" aluminum or copper.
• To eliminate the hazard of reaching over heated
surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage
is to be provided, the hazard can be reduced by
installing a range hood that projects horizontally a
minimum of 5" beyond the bottom of the cabinets.
• For Free-standing installations a slide-in range with
side panels measures 30 3/4" wide. The height of the
countertop is 36" and countertop depth is 25".
• Island or peninsula installations with 24" deep base
cabinets must use flush back (no rear toe space)
cabinets to avoid range interference,. If rear toe space
is desired, use 27" or deeper cabinets.
See page 2 for additional information
Subject to change without notice. This system is designed to
be updated daily if necessary. Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
35 3/4"
20 1/2"
36 7/16"
35 3/4"
174
35 3/4"
Wall View
(not to scale)
Wall View
(not to scale)
18"
36"
Countertop
height
5 1/2"
30" Min.
10"
30"
Range
20 1/2"
Locate electrical
supply junction
box or 60" of
electrical cable
within shaded
area.
19"
Upper cabinets
can only be 13"
deep maximum.
Over range
cabinet is NOT
recommended.
Minimum horizontal clearance
between the edge of the
appliance and combustible
3"
construction extending from
the cooking surface to 18"
above the cooking surface is
3" to the sides and 0" to the
back (see solid areas). 6"
Minimum is recommended.
30" Minimum cutout width
BN220.55 • A174B149 • • 032603 • 95659 • 42689
(not to scale)
5 1/2"
2 1/4"
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
• Some European style cabinets are equipped with vinyl drawer and
door fronts. The vinyl may not be designed to withstand the heat
produced by the normal operation of the self cleaning range.
Discoloration or delamination may occur. To avoid possible damage,
Maytag recommends increasing the 30" cabinet opening to 31 1/4"
minimum and using a heat shield kit #CABKIT V. The countertop
cutout must remain 30".
• Gas requirements: Gas supply line should be 3/4". Install a manual
shutoff valve in an accessible location in the gas line external to this
appliance for the purpose of turning on or shutting off gas to the
appliance. The appliance is shipped from the factory equipped for use
with natural gas and can be converted to LP gas. The maximum gas
supply pressure for both LP and natural gas is 14" WC. Minimum
Pressure for Natural gas is 6" WC. Minimum Pressure for LP gas is 11"
WC.
Page 2
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
Slide In Gas Ranges:
JGS8850ADS, JGS8850ADB, JGS8850ADQ and
JGS8850ADW
Kits:
• UXA9007ABB/Q/W: side panels.
• JXA9112AAP: Backsplash.
• JXA9130AAP: Backsplash.
When replacing an existing unit, a
maximum depth of 23 1/2" is acceptable.
36"
countertop height
You may need to
shave or cut the trim of
formed or metal front
edged countertops to
clear the 30 3/4" width
of cooktop.
Cutout opening
Slide-in installation
(not to scale)
23 1/4"
Recommended.
From countertop
front to rear cutout
30"
Cabinet opening
30" countertop
opening
23 5/8"
minimum
flat area
25" Normal
countertop depth
24"
Cabinet depth
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or
outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.
Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
BN220.55 • A174B149 • • 032603 • 95659 • 42689
149