PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
SLIDE-IN RANGE COUNTERTOP PREPARATION
JGS8750CD JGS8850CD
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Gas Supply Line
●
Provide a gas supply line of ³⁄₄" (1.9 cm)
rigid pipe to the range location. A smaller
size pipe on longer runs may result in
insufficient gas supply. With LP gas,
piping or tubing size can be ¹⁄₂" (1.3 cm)
minimum. Usually, LP gas suppliers
determine the size and materials used in
the system.
NOTE: Pipe-joint compounds that resist
the action of LP gas must be used. Do
not use TEFLON®†tape.
†®TEFLON is a registered trademark of E.I. Du Pont
De Nemours and Company.
Electrical Requirements
●
A 120 volt, 60 Hz., AC only, 15-amp
fused, electrical circuit is required. A
time-delay fuse or circuit breaker is also
recommended. It is recommended that a
separate circuit serving only this range
be provided.
●
Electronic ignition systems operate
within wide voltage limits, but proper
grounding and polarity are necessary.
Check that the outlet provides 120-volt
power and is correctly grounded.
Ref. W10253459B
10/06/09
30" Slide-In Gas Range
IMPORTANT: To avoid damage to your
cabinets, check with your builder or cabinet
supplier to make sure that the materials
used will not discolor, delaminate or sustain
other damage. This oven has been designed
in accordance with the requirements of UL
and CSA International and complies with the
maximum allowable wood cabinet
temperatures of 194°F (90°C).
Mobile Home - Additional
Installation Requirements
The installation of this range must conform
to the Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part
3280 (formerly the Federal Standard for
Mobile Home Construction and Safety, Title
24, HUD Part 280). When such standard is
not applicable, use the Standard for
Manufactured Home Installations, ANSI
A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range
must conform with the current standards
CAN/CSA-A240-latest edition, or with local
codes.
Mobile home installations require:
●
When this range is installed in a mobile
home, it must be secured to the floor
during transit. Any method of securing the
range is adequate as long as it conforms
to the standards listed above.
The cooktop sides of the slide-in range fit over
the cutout edge of your countertop.
If you have a square finish (flat) countertop
and the opening width is 30" (76.2 cm), no
countertop preparation is required.
Formed front-edged countertops: Must have
molded edge shaved flat ³⁄₈" (1.0 cm) from
each front corner of opening.
Tile countertops may need trim cut back
³⁄₈" (1.0 cm) from each front corner and/or
rounded edge flattened.
If countertop opening width is greater than
30" (76.2 cm), adjust the ³⁄₈" (1.0 cm)
dimension.
Countertop must be level. Place level on
countertop, first side to side; then front to
back. If countertop is not level, range will not
be level. Oven must be level for satisfactory
baking conditions.
Page 1 of 2
*Range can be raised approximately 1" (2.5 cm) by adjusting the
leveling legs.
**When installed in a 24" (61.0 cm) base cabinet with 25"
(63.5 cm) countertop; front of oven door protrudes 5" (12.7 cm)
beyond 24" (61.0 cm) base cabinet.
Models JGS8750 and JGS8850
A
G
B
C
D
F
E
A. (78.1 cm)
30¾"
B. (90.8 cm) height to
35¾"
underside of cooktop edge
with leveling legs screwed all
the way in*
C. Model/serial number plate
(located behind the storage
drawer on the right-hand side
of the oven frame)
D. (75.9 cm)
29⁷⁄₈"
E. Gas information plate (located
behind the storage drawer on
the left-hand side of the oven
frame)
F. 29" (73.7 cm) from handle to
back of range**
G. 23" (58.4 cm) countertop
notch to rear of cooktop
30"
(76.2 cm)
30
"
(78.1 cm)
³⁄₈"
(1.0 cm)

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10253459B
10/06/09
Page 2 of 2
CABINET OPENING DIMENSIONS
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth,
24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the
range, follow the range hood or microwave hood combination installation
instructions for dimensional clearances above the cooktop surface.
Range may be installed with zero clearance to combustible construction at the rear
and on the sides below the cooktop.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is shielded
by not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than
No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum
or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the
bottom of an uncovered wood or metal cabinet.
A
B
H
I
F
G
C
D
E
I
A. 13" (33.0 cm) upper cabinet depth
B. 30" (76.2 cm) min. opening width
C. For minimum clearance to the top of the cooktop, see NOTE.
D. 23¹⁄₄" (59.1 cm) opening depth
E. 30" (76.2 cm) min. opening width
F. Electrical and gas supply - 5½" (14.0 cm) min. from either cabinet,
10" (25.4 cm) max. from floor. Nothing located in shaded area can
extend more than 2¼" (5.7 cm) from back wall or range will not slide
all the way back. Grounded outlet must be flush mounted.
G. Cabinet door or hinge should not extend into cutout.
H. 18" (45.7 cm)
I. 3" (7.6 cm) min. clearance from both sides of the range to the side
wall or other combustible material.