Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing
any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.
JRC120032A 07/2012
Page 2
JENN-AIR® DETAILED PLANNING DIMENSIONS
F
Side
Cabinet
G
C*F
D
A
B
B
e
Side
Cabinet
E
g
36" GAS COOkTOP
JGC8536BD – 36" x 45⁄8" x 213⁄4"
2 of 4
OPENING/CLEARANCE DIMENSIONS
A
C*
B
E
g
FRONT VIEW
Side
Cabinet
F
e
G
MODEL #JGC8536BD
incm
Width of combustible area above
A
cooking surface (min.)
Width from cooktop to fixed wall
B
or other combustible material (min.)
Height to bottom of uncovered wood or
C*
metal cabinet above cooking surface (min.)
Height to bottom of uncovered wood
D
or metal cabinet (min.)
Height to top edge of electrical and gas
E
D
B
installation area
Depth of upper cabinet (recommended)1333.0
F
Depth from cutout to wall (min.)
G
Width of cutout34
H
Depth of cutout20
I
Depth from cutout to front of
J
countertop (min.)
e
Recommended electrical access location
g
Recommended gas supply line location
* Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal cabinet
is covered by not less than
less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm)
aluminum or 0.020" (0.5 mm) copper.
If installing a hood or microwave hood combination above the cooktop, follow the
hood or microwave hood combination instructions for dimensional clearances above
the cooking surface.
1
⁄4" (0.6 cm) flame retardant millboard covered with not
3691.4
820.3
3076.2
1845.7
7
3
⁄89.7
3
⁄41.9
7
⁄888.6
7
⁄852.9
25.1
GAS REQUIREMENTS
Natural Gas
This cooktop is factory-set for use with natural gas.
LP Gas Conversion
Conversion must be done by a qualified service technician. To convert
to LP gas, use the LP gas conversion kit provided with the cooktop.
ELECTRICAL REQUIREMENTS
120 volt, 60 Hz, AC only, 20-amp fused, grounded circuit is required.
A time-delay fuse or dedicated circuit is recommended. Minimum power
cord length is 46" (117.0 cm).
LOCATION REQUIREMENTS
• To ensure cooktop base clearance, cabinet side walls need to be wider
than the cutout.
• If cabinet has a drawer, allow a 4" (10.2 cm) minimum clearance between
countertop and top of drawer. Drawer depth may need to be shortened to
avoid interfering with the regulator.
COOKTOP OVER SINGLE WALL OVEN INSTALLATION
REQUIREMENTS
• For approved model number combinations, refer to the under counter
• To install a cooktop over a 30" single wall oven, refer to page 3.
label on the bottom of the cooktop burner box.
H
G
I
TOP VIEW – CUTOUTSIDE VIEW
Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing
any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.
J
JRC120032A 07/2012
Page 3
JENN-AIR® DETAILED PLANNING DIMENSIONS
B
D
e
e
F
E
G
A
H
C
3
⁄4" (1.9 cm)
Side Cleat
3
⁄4" (1.9 cm)
Side Cleat
2" (5.1 cm) Top Cleat
A
B
D
e
E
G
A
H
3
⁄4" (1.9 cm)
Side Cleat
3
⁄4" (1.9 cm)
Side Cleat
2" (5.1 cm) Top Cleat
SINGLE wALL OvEN AND COOkTOP COMbINATIONS
For the approved model number combinations, refer to the under counter label
located on top of the oven chassis and on the bottom of the cooktop burner box.
APPROvED MODEL NUMbER COMbINATIONS
3 of 4
SINGLE WALL OVENS
30-Inch: JJW3430W, JJW2430W, JJW2330W
27-Inch: JJW2427W, JJW2327W
INDUCTION COOKTOPS
36-Inch: JIC4536X
30-Inch: JIC4430X
OPENING/CLEARANCE DIMENSIONS
e
D
E
F
B
CC
FRONT VIEW –
UNDER COUNTER INSTALLATION
(with cooktop installed above)
H
GAS COOKTOPS
36-Inch: JGC9536BD, JGC1536AD, JGC8536BD
30-Inch: JGC9430BD, JGC1430AD, JGC8430CD
ELECTRIC COOKTOPS
36-Inch: JEC4536Y, JEC9536BD, JEC8536BD
30-Inch: JEC4530Y, JEC9530BD, JEC8430BD
JJW3430W
MODEL #
JJW2430W
JJW2330W
JJW2427W
JJW2327W
incmincm
Width of cabinet (min.)3076.22768.6
e
A
Width of cutout (recommended)28
B
Oven trim overlap
C
Bottom of countertop to floor34
D
1
⁄272.4251⁄264.8
5
⁄81.6
1
⁄287.6341⁄287.6
5
⁄81.6
Bottom of countertop to bottom
of cutout
G
gg
Induction cooktop combination30
E
Gas cooktop combination29
Electric cooktop combination29
Height of cutout (recommended)27
F
7
⁄878.4307⁄878.4
7
⁄875.9297⁄875.9
7
⁄875.9297⁄875.9
3
⁄470.5273⁄470.5
Bottom of cutout to floor
Induction cooktop combination3
G
Gas cooktop combination4
Electric cooktop combination4
Depth of cabinet (min.)2461.02461.0
H
e
Recommended junction box location
g
Recommended gas supply line location for gas cooktop
NOTE: For under counter installation, the junction box should be located in
the adjacent right or left cabinet. Drill a 1" (2.5 cm) minimum diameter hole
in an upper corner of the side wall for access to the junction box.
5
⁄89.235⁄89.2
5
⁄811.745⁄811.7
5
⁄811.745⁄811.7
CABINET REQUIREMENTS
NOTE: When using under counter installation, check cabinet manufacturer’s
specifications to verify fit.
SIDE VIEW –
UNDER COUNTER INSTALLATION
(with cooktop installed above)
Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing
any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.
A. Custom hood liners can be used with any of the following blower motors: UXB1200DYS, UXB0600DYS, UXI1200DYS or UXI0600DYS.
nnnn
nnnn
nnnn
★★★★★★★
★★★★★★★★★★★★
★★★★★★★
—
—
—
—
—
—
—
GLASS
COLLECTION
ISLAND-MOUNT
HOOD
★★
★★
★★
★★
★★
★★
★★
GLASS COLLECTION
WALL-MOUNT HOODS
—
—
—
—
—
—
—
PERIMETRIC
HOOD
★
★★
★
★
★
★★
★
OILED BRONZE
WALL-MOUNT HOODS
n
nn
—
—
n
n
nn
nn
n
—
—
—
—
n
nn
nn
—
EURO-STYLE TELESCOPING
DOWNDRAFT SYSTEMS
★
—
★★★
★
★
★
—
—
—
★★★
★★★
★
★
★
—
—
—
★★★
★★★
CUSTOM
HOOD LINERS
UXL6048YSS
UXL6036YSS
★
★
★
★
★
★
★
OVER-THE-
RANGE
MICROWAVE
OVENS
A
JMV9186W
A
JMV8208W
n
n
n
n
n
n
n
n
n
n
n
n
n
n
KEY
Style and Performance Pair
★
n
Performance Pair
Not Recommended
—
Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing
any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.
JRC120032A 07/2012
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.