www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
36" Gas Cooktops:
JGC8536ADB, JGC8536ADW, JGC8536ADQ and
JGC8536ADS
• Dimensions (Actual Size) •
Overall width:
Overall depth:
Distance from top of counter to bottom of unit:
Cut-Out width:
Cut-Out depth:
36"
21 9/16"
3 13/16"
34 7/8"
20 13/16"
Min. spacing from cooktop edge to nearest
vertical combustible wall to the RIGHT:
8"
Min. spacing from cooktop edge to nearest
vertical combustible wall to the LEFT:
8"
Min. spacing from cooktop edge to nearest
vertical combustible wall to the REAR:
Minimum spacing to front edge of counter:
3/4"
2"
Minimum distance between cooktop
and cabinet directly above:
Minimum width of cabinet directly above:
30" min
36"
Maximum depth of cabinets directly
above and adjacent:
13"
Minimum distance between countertop
and adjacent cabinet above:
18"
• Additional Information •
• Distance from top of counter to bottom of gas stub is
4 9/16".
• Distance from top of counter including manifold
entrance is 7 1/2.
• Electrical requirements : 110/120 volt AC, 60hz. Must
be grounded. 15amp circuit required. Locate outlet
below the cooktop a minimum of 5" below the
countertop if not installing over an under counter oven.
Locate outlet below the oven or in an adjacent cabinet
when installing over an adjacent under counter oven.
• Minimum clearance from top of counter to combustible
material below is 4 7/16"
• Countertop must be supported within 3" of cutout.
• Unit may be installed over a Jenn-Air under counter
oven.
Side View (not to scale)
20 13/16"
18"
1 3/4" to centerline of pipe from
back edge of cutout
3 13/16"
34 7/8"
30" min
36"
21 9/16"
Overall Dimensions
Top View (not to scale)
Cut-Out Dimensions
Countertop View
(not to scale)
Cabinet Requirements
Wall View
(not to scale)
36"
Minimum horizontal
clearance between the
edge of the appliance
and combustible
construction extending
from the cooking
surface to 18" above
the cooking surface is
8" (see solid areas)
Top view of cutout
(not to scale)
See page 2 for additional information
Subject to change without notice. This system is designed to
be updated daily if necessary. Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright © Dimension Express, 2003.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
321
Gas inlet location
1 3/4" from left side
of cutout to
centerline of pipe.
Cooktop supplied with 1/2" NPT female inlet on regulator
BN182.34 • A321B149 • • 031111 • 115727 • 89750
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
• Gas requirements : The Appliance pressure regulator supplied with
this appliance is pre-set and fixed for correct outlet pressure: 5"W.C.
this model is equipped for use with natural gas; 10" W.C. when
converting to LP. The maximum inlet gas supply pressure for the
regulator is 14" W.C. The inlet test pressure for checking the regulator
must be at least 6" W.C if equipped for natural gas; 11" W.C. if
converted to LP gas.
• An individual gas shut-off valve must be used.
• Cabinetry over cooktop : 30' minimum clearance between the top of
the cooking surface and the bottom of an unprotected wood or metal
cabinet. 24" minimum when bottom of wood or metal cabinet is
protected by not less than 1/4" flame retardant millboard covered with
not less than no. 28 MSG sheet steel, 0.015" stainless steel, 0.024"
aluminum or copper.
• To eliminate the hazard of reaching over heated surface units,
cabinet storage space located above the surface units should be
avoided. If cabinet storage is to be provided, the hazard can be
reduced by installing a range hood that projects horizontally a
minimum of 5" beyond the bottom of the cabinets.
• Radius corners of cutout and file to insure smooth edges and prevent
corner cracking (1/4" radius).
Page 2
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
36" Gas Cooktops:
JGC8536ADB, JGC8536ADW, JGC8536ADQ and
JGC8536ADS
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or
outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.
Copyright © Dimension Express, 2003.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
BN182.34 • A321B149 • • 031111 • 115727 • 89750
149