Jenn-Air JGC8430CD, JGC8536BD User Manual

30" (76.2 cm) and 36" (91.4 cm) Sealed Gas Cooktop
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 8101P643-60
09-26-08
Page 1 of 2
PRODUCT MODEL NUMBERS
JGC8430CD JGC8536BD
Gas supply: The installation of this appliance must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-Latest Edition, or, in Canada, CAN/CGA-B149 Installation Code, Latest Edition.
All supply piping, except as noted, should use common National Pipe Thread (N.P.T.). For all pipe connections use an approved pipe joint compound resistant to the action of LP gas.
This appliance is designed for use with the appliance gas pressure regulator supplied with this appliance. It must be installed in the gas line ahead of the gas manifold entrance. It is preset for use with natural gas and must be converted, as described in the Installation Instructions for use with LP gas.
This appliance is designed to operate at a pressure of 5" of water column on natural gas or, if converted for use with LP gas (propane or butane), 10" water column. Make sure this appliance is supplied with and adjusted for the type of gas for which it is designed.
This appliance was adjusted at the factory for use with natural gas. If, at any time, this appliance is to be used with a different type of gas, all of the conversion adjustments described in the Installation Instructions must be made by a qualified service technician before attempting to operate the cooktop on that gas. Natural gas should be supplied to the appliance pressure regulator at a line pressure between 6" and 14" of water column or, if converted for LP gas, between 11" and 14".
Make the gas connection to the inlet of the appliance pressure regulator with 1/2" NPT male pipe threads.
Install a manual shut-off valve in an accessible location in the gas line ahead of the appliance pressure regulator and external to this appliance for the purpose of turning on or shutting off gas to the appliance.
Make additional pipe connections as necessary ahead of the shut-off valve to the gas supply source. Assure all pipe joint connections are gas tight.
Electrical: See page 2.
PRODUCT DIMENSIONS – 36" MODEL (JGC8536BD)
PRODUCT DIMENSIONS – 30" MODEL (JGC8430CD)
IMPORTANT: Cutout
dimensions are critical. Dimensions must be measured and cut accurately to within ±1/16" (0.2 cm) to ensure proper fit.
Dimensions
"A" 28-3/4" (73.0 cm) "B" 20-5/8" (52.4 cm) "C" 2" min. (5.1 cm) "D" 5-1/16" (12.9 cm) "E" 30" (76.2 cm) "F" 21-3/4" (55.2 cm) "G" 3-11/16" (9.4 cm) "H" 12-7/16" (31.6 cm) "I" 1-3/4" (4.4 cm) "J" 1-3/4" (4.4 cm)
IMPORTANT: Cutout dimensions are critical. Dimensions must be measured and cut accurately to within ±1/16" (0.2 cm) to ensure proper fit.
Dimensions
"A" 34-7/8" (88.6 cm) "B" 20-13/16" (52.9 cm) "C" 2" min. (5.1 cm) "D" 4-9/16" (11.6 cm) "E" 36" (91.4 cm) "F" 21-9/16" (54.8 cm) "G" 3-13/16" (9.6 cm) "H" 15-1/2" (39.4 cm) "I" 1-3/4" (4.4 cm) "J" 1-3/4" (4.4 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 8101P643-60
09-26-08
Page 2 of 2
PRODUCT MODEL NUMBERS ELECTRICAL WIRING DIAGRAM
JGC8430CD JGC8536BD
Gas supply: See page 1. Electrical: This appliance is equipped with a grounded
type power cord. A grounded outlet must be provided. It is recommended, for convenience, the outlet be located within either the shaded area or the cross hatched area shown at right. Or, if an electric wall oven is to be installed below this appliance, locate the outlet within the cross hatched area or within an adjacent cabinet.
User may experience occasional circuit tripping if Ground Fault Circuit Interrupter (GFCI) outlet or breaker is in use.
In planning any installation, note that the free length of this appliance’s power cord is 46" (117 cm). The power cord exits the bottom of the burner box from a point 2-1/4" (5.7 cm) left of the right wall of the burner box, and 1-9/16" (4 cm) forward of the rear wall of the burner box, when viewed from the front of the unit.
30" (76.2 cm) and 36" (91.4 cm) Sealed Gas Cooktop
CABINET OPENING DIMENSIONS
4ʺ MAX.
10.16 cm
37 3/16 ʺ
94.46 cm
29 3/8 ʺ
74.61 cm
3 13/16 ʺ
9.7 cm
CABINET BOTTOM
31/2ʺ (8.89 cm) WIDE
SLATS WHEN A WALL
OVEN IS INSTALLED
BELOW 30 ʺ MODEL
Locate this appliance away from combustible materials such as window curtains and combustible wall decorations.
Minimum horizontal clearance between the edge of the appliance and combustible construction, extending from the cooking surface to 18" (45.72 cm) above the cooking surface:
C = 3/4" (1.9 cm) at rear D = 8" (20.3 cm) at sides
Dimensions apply to both 30" and 36" wide models.
A = 30" (76.2 cm) minimum vertical clearance between
cooking surface and construction above the appliance. This clearance may be reduced to not less than 24" (60.96 cm) by protecting the underside of the combustible material or metal cabinet above the cooking surface with not less than 1/4" (0.635 cm) insulating millboard covered with sheet metal not less than 0.0122" (0.3 mm) thick.
B = 13" (33.02 cm) maximum depth of cabinets installed
above cooktop.
Avoid use of cabinets above cooktop for storage space to eliminate associated potential hazards such as reaching over open flames.
A
B
C
D
3/4”
1.91 cm
20.32 cm
18”
45.72 cm
8”
Loading...