30" (76.2 cm) and 36" (91.4 cm) Sealed Gas Cooktop
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8101P643-60
09-26-08
Page 1 of 2
A
B
C
H
I
D
G
E
F
J
MANIFOLD
ENTRANCE
PRODUCT MODEL NUMBERS
JGC8430CD JGC8536BD
Gas supply: The installation of this appliance
must conform with local codes or, in the
absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1-Latest Edition, or, in
Canada, CAN/CGA-B149 Installation Code,
Latest Edition.
All supply piping, except as noted, should use
common National Pipe Thread (N.P.T.). For all
pipe connections use an approved pipe joint
compound resistant to the action of LP gas.
This appliance is designed for use with the
appliance gas pressure regulator supplied with
this appliance. It must be installed in the gas
line ahead of the gas manifold entrance. It is
preset for use with natural gas and must be
converted, as described in the Installation
Instructions for use with LP gas.
This appliance is designed to operate at a
pressure of 5" of water column on natural gas
or, if converted for use with LP gas (propane
or butane), 10" water column. Make sure this
appliance is supplied with and adjusted for the
type of gas for which it is designed.
This appliance was adjusted at the factory for
use with natural gas. If, at any time, this
appliance is to be used with a different type of
gas, all of the conversion adjustments
described in the Installation Instructions must
be made by a qualified service technician
before attempting to operate the cooktop on
that gas. Natural gas should be supplied to the
appliance pressure regulator at a line pressure
between 6" and 14" of water column or, if
converted for LP gas, between 11" and 14".
Make the gas connection to the inlet of the
appliance pressure regulator with 1/2" NPT
male pipe threads.
Install a manual shut-off valve in an accessible
location in the gas line ahead of the appliance
pressure regulator and external to this
appliance for the purpose of turning on or
shutting off gas to the appliance.
Make additional pipe connections as necessary
ahead of the shut-off valve to the gas supply
source. Assure all pipe joint connections are
gas tight.
Electrical: See page 2.
PRODUCT DIMENSIONS – 36" MODEL (JGC8536BD)
PRODUCT DIMENSIONS – 30" MODEL (JGC8430CD)
IMPORTANT: Cutout
dimensions are critical.
Dimensions must be measured
and cut accurately to within
±1/16" (0.2 cm) to ensure
proper fit.
Dimensions
"A" 28-3/4" (73.0 cm)
"B" 20-5/8" (52.4 cm)
"C" 2" min. (5.1 cm)
"D" 5-1/16" (12.9 cm)
"E" 30" (76.2 cm)
"F" 21-3/4" (55.2 cm)
"G" 3-11/16" (9.4 cm)
"H" 12-7/16" (31.6 cm)
"I" 1-3/4" (4.4 cm)
"J" 1-3/4" (4.4 cm)
E
H
D
I
G
F
J
MANIFOLD
ENTRANCE
A
B
C
IMPORTANT: Cutout
dimensions are critical.
Dimensions must be measured
and cut accurately to within
±1/16" (0.2 cm) to ensure
proper fit.
Dimensions
"A" 34-7/8" (88.6 cm)
"B" 20-13/16" (52.9 cm)
"C" 2" min. (5.1 cm)
"D" 4-9/16" (11.6 cm)
"E" 36" (91.4 cm)
"F" 21-9/16" (54.8 cm)
"G" 3-13/16" (9.6 cm)
"H" 15-1/2" (39.4 cm)
"I" 1-3/4" (4.4 cm)
"J" 1-3/4" (4.4 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8101P643-60
09-26-08
Page 2 of 2
PRODUCT MODEL NUMBERS ELECTRICAL WIRING DIAGRAM
JGC8430CD JGC8536BD
Gas supply: See page 1.
Electrical: This appliance is equipped with a grounded
type power cord. A grounded outlet must be provided. It
is recommended, for convenience, the outlet be located
within either the shaded area or the cross hatched area
shown at right. Or, if an electric wall oven is to be
installed below this appliance, locate the outlet within the
cross hatched area or within an adjacent cabinet.
User may experience occasional circuit tripping if Ground
Fault Circuit Interrupter (GFCI) outlet or breaker is in use.
In planning any installation, note that the free length of
this appliance’s power cord is 46" (117 cm). The power
cord exits the bottom of the burner box from a point
2-1/4" (5.7 cm) left of the right wall of the burner box,
and 1-9/16" (4 cm) forward of the rear wall of the burner
box, when viewed from the front of the unit.
30" (76.2 cm) and 36" (91.4 cm) Sealed Gas Cooktop
CABINET OPENING DIMENSIONS
4ʺ MAX.
10.16 cm
37 3/16 ʺ
94.46 cm
29 3/8 ʺ
74.61 cm
3 13/16 ʺ
9.7 cm
CABINET BOTTOM
31/2ʺ (8.89 cm) WIDE
SLATS WHEN A WALL
OVEN IS INSTALLED
BELOW 30 ʺ MODEL
Locate this appliance away from combustible materials such as
window curtains and combustible wall decorations.
Minimum horizontal clearance between the edge of the appliance
and combustible construction, extending from the cooking surface
to 18" (45.72 cm) above the cooking surface:
C = 3/4" (1.9 cm) at rear
D = 8" (20.3 cm) at sides
Dimensions apply to both 30" and 36" wide models.
A = 30" (76.2 cm) minimum vertical clearance between
cooking surface and construction above the
appliance. This clearance may be reduced to not
less than 24" (60.96 cm) by protecting the underside
of the combustible material or metal cabinet above
the cooking surface with not less than 1/4" (0.635
cm) insulating millboard covered with sheet metal
not less than 0.0122" (0.3 mm) thick.
B = 13" (33.02 cm) maximum depth of cabinets installed
above cooktop.
Avoid use of cabinets above cooktop for storage space
to eliminate associated potential hazards such as
reaching over open flames.
3/4”
1.91 cm
20.32 cm
18”
45.72 cm
8”