Jenn-Air JGC7636BP, JGC7636BS, JGC7530BP, JGC7530BS Instruction Manual

LP GAS AND HIGH ALTITUDE CONVERSION
W10588276A
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
IMPORTANT:
Installer: Leave installation instructions with the homeowner. Homeowner: Keep installation instructions for future reference.
IMPORTANT :
Installateur : Remettre les instructions d'installation au propriétaire. Propriétaire : Conserver les instructions d'installation pour référence ultérieure.
INSTRUCTIONS
FOR JGC7530B, JGC7636B, JGC1530B, AND JGC1536B MODEL SERIES
INSTRUCTIONS DE CONVERSION - GAZ PROPANE
ET ALTITUDE ÉLEVÉE
POUR SÉRIES DE MODÈLES JGC7530B, JGC7636B, JGC1530B, ET JGC1536B
Table of Contents/Table des matières
Tools and Parts.........................................................................................3
Convert from Natural Gas to LP Gas ....................................................... 3
Convert from LP Gas to Natural Gas ....................................................... 6
Lighting the Electronic Igniters ................................................................. 8
Flame Height Adjustment .........................................................................8
COOKTOP SAFETY
SÉCURITÉ DE LA TABLE DE CUISSON ................................................... 9
Outillage et pièces .................................................................................. 10
Conversion du gaz naturel au propane..................................................10
Conversion pour l’alimentation du propane au gaz naturel................... 13
Allumeurs électroniques - allumage.......................................................15
Réglage de la taille des flammes............................................................16
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
WARNING: Gas leaks cannot always be detected by smell. Gas suppliers recommend that you use a gas detector approved by UL or CSA. For more information, contact your gas supplier. If a gas leak is detected, follow the “What to do if you smell gas” instructions.
In the State of Massachusetts, the following installation instructions apply:
Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
If using a ball valve, it shall be a T-handle type.
A flexible gas connector, when used, must not exceed 3 feet.
2
Tools and Parts
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer's instructions supplied with this kit.
WARNING
Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water column.
Examples of a qualified person include: licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
C
A
B
C
D
Gather the required tools and parts necessary for correct LP gas conversion.
Tools needed
Flat-blade screwdriver
³⁄₃₂" (#0 [2.0 mm]) flat-blade screwdriver (screwdriver shaft
must be a minimum of 2½" [6.4 cm] long)
Adjustable wrench
7.0 mm nut driver
7.0 mm wrench
Parts supplied
LP orifice package (W105990568)
Conversion label (W10590570)
High Altitude Conversion
To convert the cooktop for elevations above 6,560 ft (1999.5 m), order a High Altitude Conversion Kit.
Part Number W10593220 - LP high altitude
Part Number W10593221 - Natural gas high altitude
To order, see the “Assistance or Service” section of the Use and Care Guide.
IMPORTANT: Gas conversions from Natural gas to LP gas must be done by a qualified installer. Before proceeding with conversion, shut off the gas supply to the cooktop prior to disconnecting the electrical power.
Convert from Natural Gas to LP
Gas
1. Turn manual shutoff valve to the closed position.
A. To cooktop B. Shutoff valve (closed position) C. Gas supply line
2. Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
A. Access cap B. Rear of cooktop
C. Gas pressure regulator D. Gas flow
3
3. Determine the type of regulator you have:
A
B
CDE
A
A
A
B
C
DE
Style 1: The cap has a slot and “NAT” printed on it. Remove access cap by using a flat-blade screwdriver or coin,
turning the access cap counterclockwise. The gas pressure regulator has 2 settings that are stamped
on either side of the cap. Turn the cap and reinstall into regulator with the stamp “LP” visible from the outside of the regulator.
5. If they are installed, remove the burner grates. Use the following chart to match the correct gas orifice spud with
the burner location and model being converted.
LP Gas Orifice Spud Chart
Burner Rating Stamp (A) Size
5,000 BTU 66 0.66 mm 9,000 BTU 88 0.88 mm 12,000 BTU 102 1.02 mm 10,000 BTU 93 0.93 mm
A. Size stamp
Style 2: The cap does not have a slot and requires a wrench to be removed.
Remove the access cap by using a wrench, turning the access cap counterclockwise.
Remove spring retainer from the cap by pushing against the flat side of the spring retainer. Look at the spring retainer to locate the “NAT” or “LP” position. Turn over the spring retainer so the “LP” is showing on the bottom. Snap the spring retainer back into the cap. Reinstall the cap onto the regulator.
A. Access cap B. Gasket C. Gas pressure regulator
D. LP position
E. NAT position
Burner Models
Model No. Right
JGC7530BP 9,000
JGC7636BP 9,000
JGC7530BS 9,000
JGC7636BS 9,000
front
BTU
BTU
BTU
BTU
Right rear
5,000 BTU
5,000 BTU
5,000 BTU
5,000 BTU
center front
12,000 BTU
12,000 BTU
10,000 BTU
10,000 BTU
Center rear
N/A 12,000
12,000 BTU
N/A 12,000
10,000 BTU
Left front
BTU 12,000
BTU
BTU 12,000
BTU
Left rear
12,000 BTU
12,000 BTU
10,000 BTU
10,000 BTU
Center/
High Altitude Conversions
IMPORTANT: You must convert LP gas with LP gas High Altitude
Kit Part Number W10593220 or Natural gas with Natural gas High Altitude Kit Part Number W10593221. If you need to convert LP gas to Natural gas high altitude or Natural gas to LP gas high altitude, you must convert the pressure regulator. For this, follow steps 1-3 of the necessary conversion.
LP Gas Orifice Spud Chart for High Altitude Conversion
See chart in the “LP Gas High Altitude Conversion Kit.”
Burner locations
30" (76.2 cm) Models
4. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm) water column above the set pressure. The inlet pressure to the regulator should be as follows for operation and checking the regulator setting:
LP Gas:
Minimum pressure 10" (25.4 cm) W.C.P. Supply pressure 14" (35.5 cm) W.C.P.
Gas Supply Pressure Testing Line pressure testing above ½ psi gauge (14" WCP)
The cooktop and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).
Line pressure testing at ½ psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).
4
A. Left rear burner B. Center burner C. Right rear burner
D. Right front burner
E. Left front burner
36" (91.4 cm) Models
A
B
C
D
E
F
A
B
C D
E
H
F G
A
B
C
B
C
A
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
A. Left rear burner B. Center rear burner C. Right rear burner
D. Right front burner
E. Center front burner F. Le f t f r o n t b u r n er
6. Remove all burner caps and burner bases.
8. Place Natural gas orifice spuds in plastic parts bag for future
use and keep with package containing literature.
9. Replace burner bases and burner caps. IMPORTANT: Be sure that the electrode aligns with the notch
in the burner base. The igniter electrode is ceramic and could break during installation of the burner base.
A. Burner cap B. Electrode C. Burner base
10. Open shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe.
11. Once you have completed converting all of the cooktop burners, test the cooktop for leaks by brushing on an approved noncorrosive leak-detection solution. If bubbles appear, a leak is indicated. Correct any leaks found.
A. Gas tube opening B. Burner cap slot (4) C. Burner cap D. Burner base
E. Burner base tab (4)
F. Bur n er b as e no t c h G. Orifice holder H. Igniter electrode
7. To C on ve rt Bu rn er s:
Insert 7.0 mm nut driver down onto the gas orifice spud (C) and remove by turning it counterclockwise and lifting out.
Set gas orifice spud aside.
Replace with correct LP gas orifice spud. See the LP Gas
Orifice Spud Chart.
A. Igniter electrode B. Orifice holder C. Orifice spud
12. Plug in cooktop or reconnect power.
13. Adjust valve according to “Flame Height Adjustment” section.
5