JENN-AIR® DETAILED PLANNING DIMENSIONS
30" GAS COOKTOP
JGC3530G – 30" x 43⁄16" x 21"
PRODUCT DIMENSIONS
1 of 2
TOP VIEW
E
FRONT VIEW
A
MODEL # JGC3530G
in cm
Overall width 30 76.2
A
Overall depth 21 53.3
B
Center of cooktop to center of gas inlet 1131⁄32 30.4
B
G
F
C
Width of cooktop base 295⁄16 74.5
D*
Height of cooktop base 33⁄16 8.1
E
Height from gas inlet to underside
F
of cooktop
Height of cooktop with grates 11⁄4 3.1
G
Depth of cooktop base 205⁄16 51.6
H
* Measured from tab to tab. Tabs should not be bent during installation.
43⁄16 10.6
C
D*
B
SIDE VIEW
H
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
89 94dZw217
JENN-AIR® DETAILED PLANNING DIMENSIONS
30" GAS COOKTOP
JGC3530G – 30" x 43⁄16" x 21"
OPENING/CLEARANCE DIMENSIONS
MODEL # JGC3530G
Width of combustible area above
A
cooking surface (min.)
Width from cooktop to fixed wall
B
or other combustible material (min.)
Width to outer edge of electrical outlet
C
(recommended)
Width to gas supply line location
D
(recommended)
Height to bottom of uncovered wood or
E*
metal cabinet above cooking surface (min.)
Height to bottom of uncovered wood
F
or metal cabinet (min.)
Height to top edge of electrical outlet
G
(recommended)
Height to gas supply line location
H
(recommended)
Depth of upper cabinet (recommended) 13 33.0
I
Depth from cutout to wall (min.) 25⁄16 5.9
J
Width of cutout 293⁄8 74.6
K
Depth of cutout 203⁄8 51.8
L
Depth from cutout to front of countertop 25⁄16 5.9
M
e
Recommended electrical access location
g
Recommended gas supply line location
* Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal
cabinet is covered by not less than 1⁄4" (0.6 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
If installing a hood or microwave hood combination above the cooktop,
follow the hood or microwave hood combination instructions for
dimensional clearances above the cooking surface.
GAS REQUIREMENTS
Natural Gas
This cooktop is factory-set for use with natural gas.
LP Gas Conversion
Conversion must be done by a qualified service technician. To convert to
LP gas, use an LP gas conversion kit.
ELECTRICAL REQUIREMENTS
120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit is required.
A time-delay fuse or dedicated circuit is recommended.
LOCATION REQUIREMENTS
• To ensure cooktop base clearance, cabinet side walls need to be wider
than the cutout.
• If cabinet has a drawer, allow a 4" (10.2 cm) minimum clearance
between countertop and top of drawer. Drawer depth may need to be
shortened to avoid interfering with the regulator.
B
FRONT VIEW
Side
Cabinet
I
A
E*
F
B
G
H
e
g
C
D
J
K
J
L
M
TOP VIEW – CUTOUTSIDE VIEW
2 of 2
in cm
30 76.2
6 15.2
9 22.9
12 30.5
30 76.2
18 45.7
9 22.9
18 45.7
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
89 94dZw217