Electric Convertible CooktopI : JENN-AIR 1
Models JED8130, JED8230& JED8345 _ WESTFOURTHSTREET, NORTH" NEWTON, IA50208
DIMENSIONS SHOWN IN BOTH INCHES AND CENTIMETERS
*Blowermay be rotated forhorizontalorverticaldirectionby looseningnuts aroundblowerinlet.Accessibleinsideventilation
chamber.
• NOTICE TO INSTALLER: Leave these instructions
withthe appliance.
• NOTICE TO CONSUMER: Retain these instructions
for future reference.
23.8t cm
TIE DOWN BOLT
ON EACH
:'ASE
CONTAINER
A INCHES CM
Double Bay 29 + 1/16" 73.66
TriPle Bay 43 1/4 + 1/i6 109.86 + 116
MODEL SERIES: JED8345 TRIPLE BAY
Typ. for Container Supplied,
6 1/4" (1,5,88 cm) is required for removal.
MODEL SERIES: JED8130 & JED8230 DOUBLE BAY
_EASE
CONTAINER
ql
13 t5/]6"
35. I ¢m
1
2 718 ° _ '
!
7,3 crn
ONLY MODELS WITH GRILLING FEATURE HAVE BEEN ILLUSTRATED
• Dimension "B" - Provide 2" min. (5.08 cm) cabinet clearance to motor for cooling purpose,
• Installer - Where possible, 6" (15.24 cm) is recommended for motor/blower service.
• Side Clearance - Grill models installed near a side wall must allow a minimum clearance of 6" (15,24 cm) for
maximum performance.
° Electrical Hook UP - The unit should be properly circuit protected and wired according to local electrical codes. See
electrical wiring information on back, Unit power requirements are located on the data plate.
• ** Access must be provided to remove and empty grease container(s).
"_= "=,_ 2 7/8"
68.0 cm 7.3 cm
INSTRUCTIONSTO INSTALLER,
34.9 o"a 30.0 cm
8101 P421 ..60
(10-01-oo)
Installing Cabinetry Over Your Jenn-Air Grill
A* = 30" (76.2 cm) minimumclearancebetween thetop of
thecookingplatformandthe bottomofanunprotected
woodor metal cabinet.
A* = 24" (60.96 cm) minimum clearance when bottom of
wood or metal cabinet is protected by not less than
114" (0.635 cm) FLAME RETARDANT millboard
covered with no less than no. 28 MSG sheet steel,
0.015" (0.038 cm) stainless steel, 0.024" (0.061 cm)
aluminumor copper.
Dottedlines
indicate
rangehood
construction
L i "A_" r .........d
I
* To eliminate the risk of burns or fire by reaching over
heated surface units, cabinet storage space located
above the surface units should be avoided. If cabinet
storage is to be provided, the risk can be reduced by
installing a range hood that projects horizontally a
minimum of 5 inches beyond the bottom of the cabinets.
Installer Installation Suggestions
1. Chamfer all exposed edges of decorative laminate to
prevent damage from chipping.
2. Radius comers of cutout and file to insure smooth
edges and prevent corner cracking. Recommend
1/4" or 3/8" diameter drill in each comer.
3. Rough edges, inside corners which have not been
rounded and forced fits can contribute to cracking of the
counter top laminate.
4. Countertop must be supported within 3" of cutout.
ElectricalWiring Information
The neutralofthisunitis groundedto the frame throughthe
green groundingwire. If local conditionsdo not permit
grounding of theneutral, untwist or disconnectthe green
wire and connect the green wire to ground in accordance
with localcodes. Connect the white neutral to the service
neutral.
Proper Electric Supply
You must providean adequate electrical supplysystem as
required for yourcooktop. All wire connectionsmust be in
accordance withlocalcodes and properlyinsulated.Check
with local utility for governing electrical codes and
ordinances. In the absence of local electricalcodes, the
National ElectricalCode, NFPA No. 70, governingelectric
rangeinstallations mustbefollowed.A copy ofthe National
Electrical Code, NFPA No. 70, can beobtained bywritingto:
NATIONAL FIRE PROTECTION ASSOC.
Batterymarch Park
Quincy, Massachusetts 02269
A three-wire, single phase, A.C. 1201240 volt 60 cycle
electrical system (properly circuit protected to meet Local
Codes of NFPA No. 70) must be provided. Unit must be
propedy grounded in accordance with localwiring code. The
chart below recommends the minimum circuitprotector and
wire size if the appliance is the only unit on the circuit, If
smaller sizes of wire are used, the unit efficiency will be
reduced and a fire hazard may be created. It is advisable
that the electrical widng and hookup be accomplished by a
competent electrician,
RECOMMENDED MINIMUM
K.W.RATING CIRCUITPROTECTION WIRESIZE, REMOVE
ONSERIALPLATE INAMPERES AWG KNOCKOUT
0 - 4.9 20 12 NO
5.0 - 6.9 30 10 NO
7.0 - 9.9 40 8 NO
10.0 - 11.9 50 8 **YES
12.0 - 14.9 60 6 **YES
SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE
4. FREE-STANDING CUTOUT
- 30 I/8"(76.52cm) minimum clearanceisrequired.
- Carefullymark thecountertop,recheckyourdimensionsandmake thecutout.
- NOTE: Rangesidepanelsmay bedesirableifthecutoutistoolargeorcabinetsareon oneside
oftherangeonly.
MEASURE FOR SLIDE-IN CUTOUT
- Most standard counters are 25 _ (63.50 cm) deep, 36" (91.44 era) high, and extend I" (2.54 cm)
over the cabinet front.
- Measure the countertop and overhang.
240EdwardsStreet, SE
Cleve!an&Tennessee37311
Tel:423-472-3333
Fax:423-478-6710
1. r
.
SLIDE-IN CUTOUT
- Use the overhang measurement to figure the "A" dimension:
- Carefully mark the countertop and recheck your dimensions.
- Before you cut, check the rear countertop dimensions. (See#7).
,I 1
J
OVERHANG
DIMENSION
Overhang 1f2" (I.27 cm) to 1" (2.54 cm) "A"--22 718" (58.1 lcm)
Overhang 1" (2.54 era) to 13/4" (4.45 era) "A'= 23 3/16" (58.90 cm)