Jenn-Air JED8130ADB, JED8130ADW, JED8230ADB, JED8230ADS, JED8230ADW Dimension Guide

Jenn-Air JED8130ADB, JED8130ADW, JED8230ADB, JED8230ADS, JED8230ADW Dimension Guide

www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600

 

This Data Sheet Includes Information On

 

Jenn-Air

 

Product Model Number (s):

 

30" Convertible Cooktops:

 

JED8130ADB, JED8130ADW, JED8230ADB,

 

JED8230ADS and JED8230ADW

Dimensions (Actual Size)

 

Overall width:

30"

 

Overall depth:

21 3/4"

Distance from top of counter to bottom of unit: see below

Cut-Out width: 29"

Cut-Out depth: 21"

Min. spacing from cooktop edge to nearest vertical combustible wall to the RIGHT: 8"

Min. spacing from cooktop edge to nearest vertical combustible wall to the LEFT: 8"

Min. spacing from cooktop edge to nearest vertical combustible wall to the REAR: 15/16"

Minimum spacing to front edge of counter: 1 7/8"

Minimum distance between cooktop and cabinet directly above: 30"

Minimum width of cabinet directly above: 30"

Maximum depth of cabinets directly above and adjacent: 13"

Minimum distance between countertop and adjacent cabinet above: 18"

Additional Information

Cabinetry over cooktop : 30" minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet. 24" minimum when bottom of wood or metal cabinet is protected by not less than 1/4" flame retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum or copper.

To eliminate the hazard of reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the hazard can be reduced by installing a range hood that projects horizontally a minimum of 5" beyond the bottom of the cabinets.

Countertop must be supported within 3" of cutout.

Radius corners of cutout and file to insure smooth edges and prevent corner cracking (1/4" radius).

Blower can be swiveled 90°.

See page 2-3 for additional information

Subject to change without notice. This system is designed to

 

be updated daily if necessary. Dimension Express is not

 

responsible for use of superseded, voided, or outdated data

 

sheets. Because of the difficulty or impracticability of deter-

 

mining actual damages, liability of Dimension Express shall

 

not exceed $50.00.

 

Copyright © Dimension Express, 2002.

321

30"

see below

21 3/4"

 

Side View (not to scale)

Overall Dimensions

Top View (not to scale)

Cut-Out Dimensions

21"

Countertop View (not to scale)

29"

30"

30"

18"

Cabinet Requirements

Wall View (not to scale)

Minimum horizontal clearance between the edge of the appliance and combustible construction extending from the cooking surface to 18" above the cooking surface is 8" (see solid areas).

 

 

 

 

 

 

 

 

 

Grease container

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 1/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13 13/16"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum

 

 

 

 

 

 

 

 

 

 

 

Front View

clearance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

required

 

 

 

 

 

 

 

 

 

of Cooktop and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attached Blower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(not to scale)

 

 

 

 

 

 

 

 

 

 

 

13 3/4"

 

 

11 13/16"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Provide 2" min. cabinet clearance to motor for

cooling purpose. 6" recomended for servicing.

• NEVER reuse Data Sheets. Data Sheets are subject to change without

• Call Dimension Express if you have any questions at (775) 833-3633 •

notice. Dimension Express is a FREE service bureau and is updated daily,

• Always refer to a current Code at a Glance or manufacturer directory •

it makes far more sense to spend the time necessary to request new Data

• Data Sheet codes change on the first of odd numbered months at 12:01am •

Sheets for each project, as opposed to the problems, time, costs, and risks

BN182.34 • A321B149C150 • • 032603 • 95657 • 68517

associated with reusing old Data Sheets.

www.dexpress.com

 

 

 

 

This Data Sheet Includes Information On

 

 

 

 

DIMENSION EXPRESS

 

 

 

 

Jenn-Air

 

 

 

 

Page 2

 

 

Product Model Number (s):

 

 

 

 

 

 

 

 

Fax on Demand (775) 833-3600

 

 

 

30" Convertible Cooktops:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JED8130ADB, JED8130ADW, JED8230ADB,

 

 

 

 

 

 

 

 

 

JED8230ADS and JED8230ADW

 

 

 

 

Additional Information:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electric supply: 120/240 VAC, 60Hz. 55 amp grounded circuit is required, Power cord is NOT supplied.

Duct requirements: See page 3 for ducting information and below for location.

6 1/4" Under counter access must be provided to remove and empty grease container(s).

Duct locations (not to scale)

7 9/16"

13"

9 3/8"

Top of counter to centerline of back duct location: 13"

Left edge of cutout to centerline of back and bottom duct locations: 9 3/8"

Front edge of cutout to centerline of bottom duct location: 7 9/16"

Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.

Copyright © Dimension Express, 2002.

149

• NEVER reuse Data Sheets. Data Sheets are subject to change without

• Call Dimension Express if you have any questions at (775) 833-3633 •

notice. Dimension Express is a FREE service bureau and is updated daily,

• Always refer to a current Code at a Glance or manufacturer directory •

it makes far more sense to spend the time necessary to request new Data

• Data Sheet codes change on the first of odd numbered months at 12:01am •

Sheets for each project, as opposed to the problems, time, costs, and risks

BN182.34 • A321B149C150 • • 032603 • 95657 • 68517

associated with reusing old Data Sheets.