Fig.3.
Dimming control connection
DA
-
1-10V
DALI
+
DA
DSI
-
+
Unswitched Live: Black
Switched Live: Brown
Neutral: Blue
Black
Brown
Blue
3.15A Fused Unswitched Live
Emergency
Live: Brown
Neutral: Blue
Standard
Brown
Blue
3.15A Fused switched Live
To LED Panel To Driver
Skytile ® Surface Linear
Mounting PointCable Entry
WARNINGS AND CAUTIONS
a
company
• To avoid electric shock, serious injury or property damage, isolate power before installing, removing or
servicing the product
• It is recommended that this product is installed by an electrician or a competent person with sufcient
experience to install this product.
• To be installed in accordance with the local current wiring regulations and standards
• This luminaire is suitable for indoor use only
INSTALLATION INSTRUCTIONS
Specications: Ra: 80
Product Code Wattage Lumens Colour Temp
JC72301 49W 4200 4700K
JC72301EM 49W 4200 4700K
JC72305 49W 4200 4000K
JC72305EM 49W 4200 4000K
JC73301 49W 4200 5700K
JC73301EM 49W 4200 5700K
JC72302 60W 5100 4700K
JC72302EM 60W 5100 4700K
JC72306 60W 5100 4000K
JC72306EM 60W 5100 4000K
JC73302 60W 5100 5700K
JC73302EM 60W 5100 5700K
JC72303 80W 6400 4700K
JC72303EM 80W 6400 4700K
JC72307 80W 6400 4000K
JC72307EM 80W 6400 4000K
JC73303 80W 6400 5700K
JC73303EM 80W 6400 5700K
JC72304 100W 7300 4700K
JC72304EM 100W 7300 4700K
JC73304 100W 7300 5700K
JC73304EM 100W 7300 5700K
JCC Lighting Products Ltd. Lux Park, Chichester Business Park, City Fields Way, Tangmere, Chichester, West Sussex, PO20 2FT, United Kingdom Technical Support: +44(0)1243 838986 Customer Services: +44(0)1243 838999
RoHS
Compliant
IP20
jcc.co.uk
220-240V~50-60Hz / Class I
V5_Jun_2022_RS
• Any broken or damaged parts should be replaced as soon as possible. JCC will not accept responsibility
for claims arising from sub-standard installations; which will void the warranty
• Ensure that you have the tools and accessories required to complete the installation correctly: Isolate
the power before starting the installation
• It may be necessary to upgrade your miniature circuit breakers to allow for increased inrush current
ENGLISH
1. Mark and drill mounting holes in the ceiling in a suitable location. Feed mains input cable through cable
entry on the base of the unit (Fig. 1). Secure luminaire to the ceiling and terminate the mains supply and
dimming controls as required.(Fig.3.)
2. Locate the panel by sliding the pivot pins into the guides on each end of the luminaire (Fig. 2). Slide the
panel along the grooves until pivot pins are fully home and the panel is able to hinge from one side.
3. Connect the panel to the driver using the plug & play connectors (Fig. 3).
4. Connect the LED Panel Earth lead to the corresponding Earth lead on the main body. Push panel up into
position and hold in place with the securing tabs (Fig. 4).
5. Finally rotate the safety screws situated at each side of the LED panel’s mid point to help the panel
remains stable. (Fig.5).
Note: please refer to separate instruction for microwave and step dimmable options.
1
4
You can help protect the environment. Please remember to respect the local
regulations: hand in the non-working electrical equipment to an appropriate
waste disposal centre.
The packaging material is recyclable. Dispose of the packaging in an
environmentally friendly manner and make it available for the recyclable
material collection service.
External View
Safety Screw
Cut-away View
Tab in locked
position
through 90° to
engage.

Sensor data can be set using DIP switches on the sensor. The settings are as follows:
Microwave On/Off operation and settings
Detection Area
I: Up to 8m
II: Up to 6m
III: Up to 4m
VI: Up to 3m
V: Up to 2m
II
III
IV
1 2
OnI
-
On
-
-
On
V
Note that reducing detection area
will also reduce sensitivity.
On
On
-
-
-
3
On
On
On
On
100%
75%
50%
25%
10%
-
Microwave Step Dim operation and settings
Detection Area Hold Time Standby Period Standby Dimming Level Daylight Sensor
On
On
-
-
-
3
On
On
On
On
100%
75%
50%
25%
10%
-
II
III
IV
1 2
OnI
-
On
-
-
On
V
I: Up to 8m
II: Up to 6m
III: Up to 4m
VI: Up to 3m
V: Up to 2m
Note that reducing detection area
will also reduce sensitivity.
On
Refers to the time period the lamp
remains at 100% illumination after
no motion detected.
II
III
IV
V
VI
1 2 3
OnI
-
On
-
On
-
OnOnOn
On
On
-
On
-
On
-
-
-
Hold Time
1 2 3
OnI
On
II
III
IV
V
VI
Refers to the time period the lamp
remains at 100% illumination after
no motion detected.
-
On
-
On
-
OnOnOn
On
On
-
On
-
On
-
-
-
1 2 3
5s
30s
90s
3min
20min
30min
On
Refers to the time period the lamp
remains at a low light level before it
completely switches off in the long
absense of people.
II
III
IV
V
VI
OnI
-
On
-
On
-
OnOnOn
-
-
On
-
5s
30s
90s
3min
20min
30min
On
On
On
-
-
I: Disable*
II: 50lux
(twilight operation only)
Ill: 30lux
(twilight operation only)
IV: 10lux
(darkness operation only)
V: 5lux
(darkness operation only)
The sensor can be set to only allow the lamp to illuminate below a
dened ambient brightness threshold.
*When set to Disable mode, the daylight sensor will switch on the
lamp when motion is detected regardless of ambient light level.
II
III
IV
1 2
OnI
-
On
On On
Disable*
1hr
30min
10min
5min
5sec
On
V
Refers to the low light level you
would like to have after the hold
time in the long absense of people.
On
On
-
--
3
On
On
On
Daylight Sensor
II
III
IV
V
II
III
IV
V
1 2 3
OnI
OnOnOn
On
On
-
On
1 2 3
OnI
OnOnOn
On
On
-
On
Disable
50lux
-
30lux
-
10lux
--
5lux
---
Disable
50lux
-
30lux
-
10lux
--
5lux
---
On
50%
40%
30%
20%
-
10%
-
On
The sensor can be set to only
allow the lamp to illuminate below
a dened ambient brightness
threshold.
*When set to Disable mode, the
daylight sensor will switch on the
lamp when motion is detected
regardless of ambient light level.