Jackson DynaTemp User Manual

with optional Ventless
DynaTemp®
and Energy Recovery
Models
DynaTemp with optional Ventless and Energy Recovery
Project
Item
Quantity
CSI Section 11400
Date
DynaTemp®
Standard Features
Ventless: Does not require a hood
Unique, two-pass Energy Recovery System
Low prole internal condensing system
minimizes water vapor
Sani-Sure ™ feature assures proper
rinse water temperature
Multi-cycle timer
Digital controls
Triple Wash Arm for consistent reliable
warewashing performance
Self-diagnosing digital controls diagnose
most common issues and indicate what the issue is if something happens that aects the operation of the dishmachine
Specially designed stainless steel nozzles
provide superior cleaning action
17-1/4” (438 mm) door opening accepts
18” (457 mm) trays
Interchangeable wash/rinse arms screw
out for simple cleanup
Built-in pressure regulator and door
interlock are standard
Auto-ll/auto-start
Door switch
Delime/manual wash switch
Low watt density electric wash tank heater
Hi-limit thermostat and low water
protection
Adjustable bullet feet
Front and side dress panels
Detergent/rinse additive signal connection
fuse box
Self-draining stainless steel pump
Interchangeable scrap baskets
Mandatory Specs
Specify:
Electric
Steam
Specify voltage _____________
Options
480V Electrical Single Phase 1/2” Pressure Regulator Drain Quench System Scaltrol Water Hammer Arrestor Flanged Feet Steam Booster Heater Security Package
Accessories
36-Compartment Rack
4-1/8” tall (105 mm) 5-5/8” tall (143 mm) 7” tall (178 mm)
Combination Rack Peg Rack
with optional Ventless
and Energy Recovery
_
Specifications
Uses 0.69 gallons (3 liters) of water per rack
Total automatic (normal) cycle - 88 seconds
39 racks per hour (normal) cycle
Built-in 70°F (38.9°C) rise booster heater
1 hp wash pump motor
Single point connections for all utilities
Cold water connection only
Field convertible from straight through to corner and vice versa
Field convertible from 3-phase to single- phase and vice versa
Durable stainless steel construction
Uses standard 20” X 20” (508 mm X 508 mm) racks
www.jacksonwws.com
DynaTemp®
29 1/2
4
[102 mm]
C
] m
4
m
8
3
4
/
6
1
[8
9
with optional Ventless
and Energy Recovery
10 1/4
[259 mm]
MODEL NO.
DynaTemp
VER
DIMENSION REQUIREMENTS
Wall Clearance - Rear (minimum)
Wall Clearance - Corner Installation Side (minimum)
Standard Table Height
Inside Clearance
OPERATING CAPACITY
Racks per Hour
OPERATING CYCLE (seconds)
Normal
Heavy
Extra Heavy 220 11
OPERATING TEMPERATURES
Wash (minimum) 150° F (66° C)
Rinse (minimum)
WASH PUMP MOTOR
Wash Pump Motor Horsepower
Electric Wash Tank Heater
Electric Rinse Tank Heater - 70˚F (38.9˚C) Rise
[750 mm]
A
] m m 1
3 [2
MACHINE DIMENSIONS
HEIGHT WIDTH DEPTH
63-1/8”
(1604 mm)
B
12 3/4
[323 mm]
30-5/16”
(770 mm)
Wash
40
90
Rinse
] m
/8
m
1
3
3
0
6
6 1
[
]
m 8 /
]
m 4 /
m 3
7 7
9
1
[
m
1
4
1
4
4
0 [1
/8 5
5 2
B
WIDTH
BETWEEN TABLES
11
11
25-5/16”
(643 mm)
29-1/2”
(749 mm)
Normal
39
Condensate
Dwell Total Cycle
Removal
7
7
7
Volts
208V
230V
460V
208V 10.5
230V 12.9
460V 12.9
17 1/4
[440 mm]
A
] m m 1
5 6
[
C
15 5/8
[398 mm]
DRAIN
HEIGHT
14-1/2”
(368 mm)
1-1/4” (32 mm)
6-1/4” (159 mm)
34” (864 mm)
17-1/4” (438 mm)
81” (2057 mm)Machine Height with Door Open
Heavy25Extra Heavy
30
30
30 268
13
88
138
180° F (82° C)
1 HP
KW
4.1
5.0
5.0
] m
2 /
m
1
7
1
[3
8 5/8
[219 mm]
]
Distance from
m
/8
Wall to Rear
3
m 9
3
) n e
]
p
m
o r
m
1
o
7
8
o
5
d
0
h
2 [
it w
(
] m
/4
m
1
3
2
1
1
[3
Rack Rail
4
3
8 [
[214 mm]
Distance from
Wall to Right
Rack Rail
8 7/16
30 3/8
[770 mm]
LEGEND
A- DRAIN 1-1/2" IPS
B-WATER INLET 1/2" NPT
C-ELECTRICAL CONNECTION
3 5/8
[93 mm]
All vertical dimensions are +1 1/2" due to
adjustable bullet feet.
SHIPPING INFORMATION
WEIGHT CLASS CUBE HEIGHT WIDTH DEPTH
385 lbs
(175 kg)
150
57
cu. ft.
68-5/8”
(1743 mm)
33”
(838 mm)
42”
(1067 mm)
STEAM REQUIREMENTS
Steam Flow Pressure (PSIG)
Consumption @ 15 PSIG (Ibs/hr)
15-20
WATER REQUIREMENTS
Inlet Temperature
Gallons per Hour
Gallons per Rack
Waterline Size IPS (minimum)
Drainline Size IPS (minimum)
Operating Flow Pressure (PSI)
Flow Pressure Connection (PSI) 40
Wash Tank Capacity 8 gal (30 L)
Booster Tank Capacity 3 gal (11 L)
40 - 90° F (4.4 - 32.2° C)
26.91 gal (101.9 L)
.69 gal (2.6 L)
3/4”
1- 1/2”
8
APPROXIMATE LOAD AMPS
70˚F (38.9˚C)
Rise
AMPS
75.8
46.3
83.6
50.7
24.1
Steam
AMPS
6A
6A
6A
6A
N/A
Power Supply
208V/60HZ/1PH
208V/60HZ/3PH
230V/60HZ/1PH
230V/60HZ/3PH
460V/60HZ/3PH
HOW TO SPECIFY:
No
Booster
AMPS
24.6
16.3
26.6
17.5
7.9
DynaTemp with optional Ventless & Energy Recovery
[127 mm] Minimum
45
5
Jackson WWS, Inc.
Shipping Address: 6209 North U.S. Highway 25E, Gray, KY 40734
www.jacksonwws.com
Mailing Address: P.O.Box 1060, Barbourville, KY 40906 Telephone: 888-800-5672 • Fax: 606-523-1799 Email: info@jacksonwws.com 07610-004-41-23 [01/26/17]
We reserve the right to change specications in this bulletin without incurring any obligation for equipment previously or subsequently sold.
Loading...