Jackson Conserver AXL General Manual

Conserver™ AXL
Models
Cons erve r™ AXL
Door Type
Project
Item
Quantity
CSI Sec tion 11400
Approval
Date
Specifications
U s e s 1 . 5 g a l l o n s ( 6 l i t e r s ) o f w a t e r p e r r a c k
Standard Features
Universal timer
Built in waste accumulator
3” (76 mm) stainless steel adjustable
bullet feet Delimer switch for easy removal of
hard water deposits Removable scrap screen
Three selectable timer cycles
Air gap instead of vacuum breaker
Door safety switch
Convenient top mounted controls
Auto start
Interchangeable stainless steel arms
1 7 - 1 / 4 ” ( 4 3 8 m m ) v e r t i c a l i n s i d e c l e a r a n c e
Mandatory Specs
Specify voltage
Optional Features
Solid bowl option
Accessory Items
36 Compartment racks
(4-1/8”, 5-5/8”, or 7”)
(105 mm, 143 mm, 178 mm)
Combination rack Peg rack Sanitizer alarm Scaltrol Water hammer arrestor
3 7 r a c k s p er h o u r
S i n g l e p o i n t e l e c t r i c a l c o n n e c t i o n
S e l f - d r a i n i n g s t a i n l e s s s t e e l p u m p e l i m i n a t e s s o i l / d e t e r g e n t c a r ­r y o v e r b e t w e e n w a s h a n d r i n s e c y c l e s
F i e l d c o n v e r t i b l e f r o m s t r a i g ht t o c o r n e r a n d c o r n e r t o s t r a i g h t f o r f l e x i b l e i n s t a l l a t i o n s a n d a p p l i c a ­t i o n s .
D u a l - p o i n t d r a i n c o n n e c t i o n s a l l o w f or v e r s a t i l e i n s t a l l a t i on s
Highway 25E
P. O. B ox 1060
Barbourvil le, KY 40906
Tel: 606-523-9795
Tel: 1-888-800-567 2
Fax: 606-523-9 196
E-mail: in fo@jacksonmsc.com
3 b u i l t - i n d i s p e n s i n g p u m p s f o r d e t e r g e n t , r i n s e a g e n t a n d s a n i t i z e r a r e c o n t r o l l e d b y i n d i ­ v i d u a l p r i m i n g s w i t c h e s
F u l l y a u to m a t i c t i m e d c y c l e s - 9 0 s e c o n d s , 3 m i n u t e s o r 5 m i n ­ u t e s
L a r g e r e m ov a b l e s c r a p s c r e e n
H e a v y d u t y s t a i n l e s s s te e l c o n s t r u c t i o n
www.jacksonms c.com
07610-003-38 -80 (08/07)
5
1 4
[134mm]
1 2
[13mm]
18 [459mm]
21
1 2
[545mm]
8 [202mm]
5 [128mm]
A
B
A - Electrical Connection B - Water Connection,
1
4
"
Legend
Bowl Option - Right Side View
Bowl Option - Front Side View
Table height
17
1 4
[438mm]
34 [864mm]
68 1/2 [1740mm]
6
3 4
[174mm]
6 [155mm]
32 [813mm]
Maximum Dish Clearance
A
LEGEND:
A - Electrical connection B - Water inlet 1/2" I.P.S C - Drain connection 2" I.P.S
All vertical dimensions are +/- 1/2" from floor due to adjustable bullet feet.
With doors open
3
1 2
[86mm]
65 1/4 [1658mm]
78 [1981mm]
57 1/4 [1454 mm]
B
C
9 1/2 [241mm]
Standard clearance between the wall and the machine with dishtable is 4".
3 [77mm]
1 [28mm]
32 3/4 [832mm]
13
1 4
[334mm]
POWER REQUIREMENTS
Con server™ AX L
WATER REQUIREMENTS
Inlet Temperature 120°F
Was h Operating
Rinse Op erating
PERFORMANCE CAPABILITIES
Flow Pressure (PSI) 15-25
Wash Pump Motor Horsepower
Pump Capacity (GPM) 55
Minimum Chlorine Required (PPM) 50
DIMENSIONSSTANDARD MODEL
MODEL NO.
Con server™
AXL
HOW TO SPECIFY  EXAMPLE:
Conserver™ AXL - Chemical sanitizing, 115 volt, 1 phase
Highway 25E
P. O. B ox 1060
Barbourvil le, KY 40906
MO DEL EL ECT RICAL
RE QUI REM ENT
SE RVI CE BRE AKE R
SI ZE
115v/60~1ø- 11.4A 15A
MI NIM UM RE COM MEN DED
140°F
Temp eratures
Temp eratures
49˚C
120°F
49˚C
120°F
49˚C
60˚C
140°F
60˚C
140°F
60˚C
3/4
HE IGH T WI DTH DE PTH WE IGH T CL ASS CU BE HE IGH T WI DTH DE PTH
68-1/2”
(1740 mm)
We reserve the right to change specications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.
SI ZE
32”
(813 mm)
Tel: 606-523-9795
Tel: 1-888-800-567 2
Fax: 606-523-9 196
E-mail: in fo@jacksonmsc.com
32-3/4”
(832 mm)
DR AIN
HE IGH T
9-1/2”
(241 mm)
SH IPP ING IN FO DI MEN SIO NS
280 lbs
(127 kg)
www.jacksonms c.com
07610-003-38 -80 (08/07)
92.5 44.7 cu. ft.
78”
(1981 mm)
33”
(838 mm)
(762 mm)
30”
Loading...