HUP80.qxd 23/6/03 2:19 pm Page 1
AC/DC External Desktop
|
|
|
|
80 Watts |
XPiQ inc. |
||
HUP80 Series |
Intelligent Design Quality Product |
||
|
|
||
|
|
|
|
• |
Meets EN61000-3-2 |
|
|
|
|
• |
|
|
|
Built-in EMI Filter |
|
|
|
• |
|
|
|
100% Burn-in |
|
|
|
• |
|
|
|
Input Surge Current Protection |
|
|
|
• |
|
|
|
CE Mark |
|
|
|
• |
|
|
|
Approved to UL, CSA and TUV |
|
|
|
Safety Standards |
|
|
|
• |
|
|
|
Wide Input Voltage 90-264 VAC |
|
|
|
|
|
Specification
All specifications typical at nominal line, full load and 25°C
Input
Input Voltage |
• |
90-264 VAC |
Input Frequency |
• |
47 to 63 Hz |
Input Current |
• |
1.9A maximum |
Output
Output Voltage: |
• |
See Tables |
Output Current |
• |
See Tables |
Output Power Range |
• |
0 to 80 Watts |
Ripple and Noise |
• |
1% peak to peak max. |
Overvoltage |
• |
Provided on output #1 only set at |
Protection |
|
112-132% of its nominal voltage |
Overcurrent |
• |
All outputs protected to short |
Protection: |
|
circuit conditions |
Temperature |
• |
All outputs ±0.04%/°C |
coefficient: |
|
maximum |
Transient Response |
• |
Maximum excursion of 4% or better |
|
|
on all models. Recovers to 1% of final |
|
|
value within 500 µs after a 25% step |
|
|
load change |
Environmental
Operating |
• |
0 °C to +70 °C, derate linearly from |
Temperature |
|
100% load at +40 °C to 50% load |
|
|
at +70 °C |
Storage |
• |
-40 °C to +85 °C |
Temperature |
|
|
MTBF |
• |
100,000 hours minimum at full load |
|
|
at 25 °C ambient |
EMC & Safety
EMI Requirement |
• |
Meets conducted and radiated |
|
|
limits of |
|
|
a) FCC Part 15 Class B |
|
|
b) CISPR 22 Class B |
Safety Requirements |
• |
Approved to: |
|
|
a) UL 1950 |
|
|
b) CSA C22.2 No. 234 per cUL |
|
|
c) EN60950 |
General |
|
|
Efficiency |
• |
83% typical |
Hold-up time |
• |
12 msec minimum |
Line Regulation |
• |
±1% maximum at full load |
Inrush Current |
• |
15A max. at 115 VAC or |
|
|
30A max. at 230 VAC cold start |
Withstand Voltage |
• |
3000 VAC from input to output |
|
|
1500 VAC from input to ground |
|
|
500 VAC from output to ground |
Insulation Resistance |
• |
100 Mohm minimum from |
|
|
output to ground |
• |
|
PH: 508 |
429.9883 |
• |
|
|
|||||
|
|||||
|
|
|
FAX: 800 |
226.2100 |
|
71 www.XPiQ.com |
|
|
Email: sales@xpiq.com |
|
|
|
|
Holliston, MA 01746 USA |
|
||
|
|
|
|||
|
|
|