Iproven BBT-113AI User Manual

Digital Thermometer
Model: BBT-113Ai
Thermometric sensor
LCD
ON/OFF button
Thermometer tip
Congratulations on your purchase of this product. Please read the instructions carefully before using the thermometer for the rst time and keep these instructions in a safe place. This product is intended for the measurement of human body temperature.
Basal body temperature (BBT)
Operating Instructions
1. Before use please disinfect the probe.
2. Press the button once to switch on the device.
3. The thermometer runs a check during which all the digital segments will appear on the LCD and a soft beep will sound.
4. After this check the LCD shows --.-- ˚F (or˚C), the thermometer is now ready for use.
5. Place the thermometer in the desired measurement position (oral or rectal).
6. Wait until the measurement is taken and saved in the memory. This is indicated by 3 soft beeps.
7. Write the result in the chart directly or use the memory function later.
8. Press the button to switch o the thermometer. If the thermometer is not switched o, it will automatically switch o after 3 minutes.
Memory function
To see the saved measurement:
1. Make sure the thermometer is o. If needed, press the button once to switch o.
2. Hold the button for 4 seconds and release it as soon as “LAST” appears in the LCD.
3. The last measurement will now be shown.
4. The thermometer will automatically switch o after 3 minutes.
Switching ˚F and ˚C
To switch to the other scale:
1. Make sure the thermometer is o. If needed press the button once to shut o.
2. Hold the button for 7 seconds (ignore “LAST” and keep holding) release the button as soon as “SET” appears.
Battery compartment
3. “C-F” will appear and the current setting is ashing.
4. Press the button to change.
5. Leave the button untouched for 3 seconds, the thermometer will save the setting and switch o.
Methods of measuring temperature
The accuracy of a body temperature reading depends on the position where it is measured. When charting the body temperature, always indicate the measurement position. The usual measuring time is approximately 40 to 60 seconds. A measurement is only completed when the temperature rises less than
0.05˚F(0.1ºC) within 16 seconds.
NOTE: the axillary measurement is NOT valid for Basal Body Temperature measuring.
Rectal Measurement
From a medical point of view this is the most accurate method because this position is closest to the core of the body. The thermometer tip is inserted carefully into the rectum for a maximum of 1“ (2 cm).
Oral Measurement
This is the most convenient measurement position for daily BBT measurements. There are dierent heat zones in the mouth. As a general rule, the oral temperature is 0.5-1.4˚F (0.3-0.8 ˚C) lower than the rectal temperature. To ensure that the reading is as accurate as possible: place the thermometer tip to the left or right of the root of the tongue. Keep the thermometer tip constantly in contact with the tissue under the tongue. Keep your mouth closed during the reading. Important! Eating, drinking and breathing through the mouth will inuence the temperature of the mouth tissue. You will not be able to get an accurate BBT reading after eating or drinking. Also try not to breathe through the mouth within 3 minutes before taking an oral measurement.
Cleaning and disinfection
The best way to clean the thermometer tip is by applying a disinfectant (e.g. 70% ethyl alcohol) with a damp cloth. This waterproof thermometer can be immersed in liquid or lukewarm water for thorough cleaning and disinfection.
Safety precautions
• Do not expose the thermometer to water hotter
than 122˚F (50˚C).
• Do not expose the thermometer to high
temperatures or direct sunlight.
• Do not drop the thermometer. It is not shock-proof
nor impact-resistant.
• Do not bend or open the device (except the
battery compartment).
• Do not clean with thinners, petrol or benzine; Only
clean the thermometer with water or disinfectant.
• Do not immerse the thermometer under water
deeper than 15cm for longer than 30 minutes.
• The thermometer contains small parts (including a
battery) which can be swallowed by children. For this reason, do not leave the thermometer unattended in the hands of children.
• If the ambient temperature is over 95ºF(35ºC), dip the thermometer tip in cold water for 10 seconds prior to measuring the temperature.
• Persistent fever, in particular in children, has to be treated by a doctor. If this occurs please get in touch with your doctor!
Explanation of display messages:
--.-- ˚F (or ˚C) The thermometer is measuring. HiºC or HiºF Temperature is over 43 ºC or 109.4 ºF. ERR Error code; Please contact customer support. The Battery is empty.
Battery replacement
The battery is empty and needs replacing when the battery symbol appears on the right of the LCD. Remove the battery cover and replace the battery with one of the same type (preferably non-mercury. With the thermometer lying on the display side, the “-” sign faces up. To protect the environment, please do not dispose of batteries as normal waste. Instead, please hand them in at a collection point or municipal recyclable material centre as special waste.
Technical data
Type: maximum thermometer Measurement range: 89.60~109.40ºF (32.00~43.00ºC) Measurement accuracy:
±0.20ºF within 95.90~107.60ºF ±0.40ºF within 89.60~95.90ºF (±0.10ºC within 35.50~42.00ºC ±0.20ºC within 32.00~35.50ºC)
Storage/transport conditions: (-25~55)ºC, RH≤95% Operating conditions: (5~35 ºC), ≤80%RH Min Scale: 0.01ºF (0.01 ºC) Battery type: Alkaline manganese battery, type LR41,
1.5V. Service life: minimum 100 hours under continuous operation. Weight: Approx. 12g
Explanation of symbols
The battery in this product complies with the requirements stated in European Directives 2006/66/EEC. Type BF equipment.
This electronic product must not be mixed with conventional domestic waste. Take this product to an appropriate waste collection point for correct handling and recycling.
Legal requirements and guidelines
This product complies with the European Directive for Medical Devices 93/42/EEC and carries the CE mark. The device also complies with the specications of the European Standard for Clinical Thermometers Part 3: Performance of compact electrical thermometers (non-predictive and predictive) with maximum device.
The CE marking conrms that this is a medical device with a measuring function as dened by the Medical Devices Act, which has undergone a conformity assessment procedure. Notied Body 0197 conrms that this product fullls all the appropriate statutory regulations. This thermometer conforms to all of the requirements established in ASTM Standard E 1112. Full responsibility for conformance of this product to the specication is assumed by iProvèn, 9450 SW Gemini Dr #48879, Beaverton OR, 97008-7105.
Calibration check
This thermometer is initially calibrated at the time of manufacture. If this thermometer is used according to the operation instruction, periodic re-adjustment is not required. However, if there are indications that the product does not maintain the dened error limits or if the calibration could have been aected by an external factor or by any other means a calibration check should be carried out immediately. For callibration please observe any national statutory or administrative regulations. The calibration check can be carried out by any competent authority or by authorised service providers. Test instructions for a calibration check can be provided to the relevant authorities and authorized service providers on request.
Warranty
This Limited Warranty covers any defects in material or workmanship under normal use during the Warranty Period of 365 days after purchase. iProvèn will either replace the product or repair the Product at no charge, using new or refurbished replacement parts. A replacement product or product part assumes the remaining warranty of the original product purchase. This Limited Warranty does not cover batteries and packaging neither any problem that is caused by: conditions, malfunctions or damage not resulting from defects in material or workmanship.
Customer support
For obtaining warranty service and for any other inquiries or suggestions please contact iProvén customer support at www.iproven.com
This product is manufactured for: iProvèn USA LLC
Address: 9450 SW Gemini Dr #48879
Beaverton - OR 97008-7105
Manual 20170208 BBT-113Ai version 2.0
Issuing date: 15-feb-2017