International Power Sources WU400, WU309, WU308, WU307, WU306 Datasheet

...
10/15 Watts
WU Series
4:1 Input Range
Isolated Outputs
Efficiency to 84%
Overvoltage Protection
Input
Short Circuit Protected
Fully Regulated Outputs
Specification
Intelligent Design Quality Product
XPiQ inc.
DC/DC Converters
Input
Input Voltage Range • See Table Input Filter π Network
Output
Voltage Accuracy ±1.0% max. Line Regulation ±1.0% max.
(Full Input Range) Load Regulation ±1.0% max.
(1/4-full load) Ripple & Noise 1% of Vout max.
(DC-20 MHz) Temperature ±0.02%/°C max.
Coefficient Short Circuit Indefinite
Protection
General
Switching • 100 kHz Frequency
Efficiency See Table Isolation 500 VDC
(Input-Output) (1000 Mohm/80pF)
Environmental
Operating -25°C to +71°C Temperature
Storage -55°C to 125°C Temperature
All specifications are typical at nominal line, full load and 25°C
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xp-iq.com
Holliston, MA 01746 USA
www.XP-iQ.com
25
Mechanical Details
Logic Compatibility ................CMOS or Open Collector TTL
Ec- ON,........................................>+5.5 VDC or Open Circuit
Ec- OFF, ..................................................................<1.8 VDC
Shutdown Idle Current ..................................................10 mA
Input Resistance ......................(E
in
0 VDC to 9 VDC)100KOhm
Control Common ........................Referenced to input Minus
REMOTE ON/OFF CONTROL
Output may optionally be externally trimmed (±5%)
with a fixed resistor or an external trimpot as shown.
EXTERNAL OUTPUT TRIMMING
PIN SINGLE DUAL TRIPLE
1 + Input + Input Disable 2 - Input - Input - Input 3 + Output + Output + Input 4 Trim Common - Output 5 - Output - Output Common 6 Disable Disable 5 VDC Output 7 - - + Output
NOTES:
1. Voltage accuracy on 3VDC and triple outputs ±3% Max. Single outputs can be trimmed ±5%.
2. Load regulation ±2% for dual and triple outputs.
3. Triple outputs require minimum of 10% load for rated performance.
4. Remote on/off standard on triple output units, add suffix “E” to part number for option on single and dual output units.
SINGLE/DUAL OUTPUT
TRIPLE OUTPUT
OUTPUT VOLTAGE & CURRENT RATINGS WU
Model Input Output Output Input Current %
Voltage Voltage Current No Load Full Load Efficiency
WU100 4.5-6.0 VDC 3.3 VDC 3000 mA 10 mA 2470 mA 80 WU101 4.5-6.0 VDC 5.0 VDC 2000 mA 10 mA 2620 mA 76 WU102 4.5-6.0 VDC 12.0 VDC 800 mA 10 mA 2520 mA 76 WU103 4.5-6.0 VDC 15.0 VDC 667 mA 10 mA 2510 mA 80 WU104 4.5-6.0 VDC ±5.0 VDC ±1000 mA 10 mA 2620 mA 76 WU105 4.5-6.0 VDC ±12.0 VDC ±400 mA 10 mA 2520 mA 76 WU106 4.5-6.0 VDC ±15.0 VDC ±333 mA 10 mA 2510 mA 79 WU200 9.0-18.0 VDC 3.3 VDC 3000 mA 10 mA 1030 mA 80 WU201 9.0-36.0 VDC 5.0 VDC 3000 mA 30 mA 1560 mA 80 WU202 9.0-36.0 VDC 12.0 VDC 1250 mA 30 mA 1540 mA 81 WU203 9.0-36.0 VDC 15.0 VDC 1000 mA 30 mA 1525 mA 82 WU204 9.0-36.0 VDC ±5.0 VDC ±1500 mA 30 mA 1560 mA 80 WU205 9.0-36.0 VDC ±12.0 VDC ±625 mA 30 mA 1540 mA 81 WU206 9.0-36.0 VDC ±15.0 VDC ±500 mA 30 mA 1520 mA 82 WU207 9.0-36.0 VDC 5.0/±12.0 VDC 1500/±310 mA 20 mA 1576 mA 79 WU208 9.0-36.0 VDC 5.0/±15 VDC 1500/±250 mA 20 mA 1582 mA 79 WU209 9.0-36.0 VDC 5.0/+12.0/–5.0 VDC 1500/310/500 mA 20 mA 1447 mA 79 WU300 18.0-36.0 VDC 3.3 VDC 3000 mA 10 mA 500 mA 83 WU301 20.0-72.0 VDC 5.0 VDC 3000 mA 20 mA 760 mA 82 WU302 20.0-72.0 VDC 12.0 VDC 1250 mA 20 mA 750 mA 83 WU303 20.0-72.0 VDC 15.0 VDC 1000 mA 20 mA 745 mA 84 WU304 20.0-72.0 VDC ±5.0 VDC ±1500 mA 20 mA 760 mA 82 WU305 20.0-72.0 VDC ±12.0 VDC ±625 mA 20 mA 750 mA 83 WU306 20.0-72.0 VDC ±15.0 VDC ±500 mA 20 mA 745 mA 84 WU307 20.0-72.0 VDC 5.0/±12.0 VDC 1500/±310 mA 15 mA 778 mA 80 WU308 20.0-72.0 VDC 5.0/±15.0 VDC 1500/±250 mA 15 mA 781 mA 80 WU309 20.0-72.0 VDC 5.0/+12.0/–5.0 VDC 1500/310/500 mA 15 mA 715 mA 80 WU400 36.0-72.0 VDC 3.3 VDC 3000 mA 10 mA 245 mA 84
Dimensions in inches (mm).
Note: Nominal Input Voltage 5,12, 24 or 48 VDC
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xp-iq.com
Holliston, MA 01746 USA
www.XP-iQ.com
26