Intermec 6642 User Manual

Page 1
Charger Specifications
AC Adapter Power (18V 1.5A) LEDs Power, Charge Power Consumption 27W Operating Temperature
41° to 95° F (5–35C)
Storage Temperature -4° to 140° F
Dimensions 5.9” x 10.86”x 2.12”
(150 x 276 x 54mm)
Weight 2 lbs (917g) AC
Adapter and Charge Unit
Battery Charge Time
Battery Operating Time
Approximately 3–5 hours
Approximately 2.5 to 4 hours
WARNING: High temperatures will degrade the performance of these
batteries. Store ONLY in a cool, dry location.
Spent batteries MUST be recycled. Contact local authorities for a nearby battery recycling program.
Intermec is a trademark of Intermec Technologies Corporation. Copyright 2000 Intermec Technologies Corporation. All rights reserved.
PN: 962-000-012
Revision A
December 2000
*962000012*
P/N 962-000-012 Revision A
6642 EXPANSION BATTERY CHARGER GUIDE
Packing List
Guide P/N: 962–000–012 AC Adapter/Charger P/N: 871–006–030 Charger Unit P/N: 871–008–060 AC Power Cable P/N: 871–006–050
"
NOTE: This Battery Charger permits external charging of two
Intermec–labeled Lithium–Ion Battery Packs, P/N 317–106–001, rated 11.1 V 3600 mAH only.
Charger Indicator LEDs
Power Green
Charge
Orange Flashing (80%) Steady (90%)
Green (Fully Charged)
Error Condition Red
Page 2
Setup–Connecting the AC Adapter/Charger to the Charge Unit
1. Unpack the unit and follow the steps outlined below.
WARNING: Use only the AC Adapter P/N 871-006-030 supplied with
the 6642. Use of other AC adapters or AC adapter cords could result in fire or equipment damage.
Battery Insertion
1. Set the battery lock to the unlocked position on the expansion battery before inserting it into the charger.
2. Open the battery connector cover on the charging slot.
3. Slide the battery into the slot.
4. Slide the battery downward until it snaps in the battery charge slot.
5. Slide the battery lock to the locked position.
"
NOTE: When batteries are charged at different intervals,
one battery is fully charged first, then the second battery is charged.
Battery Removal
6. Battery removal is the reverse of installation.
7. When charging is completed, disconnect the AC adapter and the power cord.
Loading...