Model: T2005
CLOCK
N.C.
LOAD
lR3730
NO.
LOAD
CALENDER DIAL TIME SWITCH
FOR UP TO 42 TIMING OPERATIONS
0N 7- DAY SCHEDULE
SINGLE POLE DOUBLE THROW
SWITCH RATING: 20 AMP. 125-480 VolTS A.C.
1/2 HP-125V 1 HP-250V.
CloCK MoToR: 125 VolTS - 60 HZ.
MINIMUM oN oR oFF TIMe IS 2 HoURS,
eXTeNdABle IN 2 HoUR INCReMeNTS.
TIMe
dIAl
MANUAl
leVeR
CAP
NUTS
FIG. 1 WIRING dIAGRAM
INSUlAToR
WIRING INSTRUCTIoNS
This Time Switch can be wired to control two circuits as Single Pole
Double throw, or to control one circuit as Single Pole Single Throw. Either
normally open (NO) or normally closed (NC).
To PRoGRAM TIMe SWITCH, Depress tripper(s) into dial at desired
1.
time(s) operation(s) is/are required.
• oN TIMe: First tripper turns on the load for 135-145 minutes.
Each additional tripper will lenghten the on time by 2 hours.
• oFF TIMe: First tripper in raised position turns off the load for 95-
105 minutes. Each additional space will lengthen the off time by
2 hours.
2.
SeT TIMe-oF-dAY: Turn dial in CLOCKWISE direction only and
align the exact day-of-week and time-of-day on dial (the time when
switch is being put in operation) to the “TIME” indicator.
oPeRATING INSTRUCTIoNS
To CoNTRol loAdS MANUAllY, Move manual lever (See Figure
1) up. This lever will close normally open circuit and open the normally
closed circuit. To return, to automatic control, move lever back to its
original position .
To ReMoVe MeCHANISM FRoM CASe, disconnect electricity and all
wiring. Depress retainer spring at upper left, or unscrew mounting screws,
then grasp dial and pull mechanism out.
IN CASe oF PoWeR FAIlURe, or retard/advance time reset dial. See
step (2) of programming instructions.
INTERMATIC INCORPORATED
158TS11135
SPRING GROVE, ILLINOIS 60081-9698
CLOCK
MOTOR
SUPPLY
NORMALLY CLOSED CIRCUIT
NORMALLY OPEN CIRCUIT
COM.N.C.N.O.