FILTER PUMP: 1 HP - 120V, 2 HP - 240V; AIR BLOWER: 1 HP - 120V, 2 HP - 240V. VALVE ACTUATOR: 24V up to 3 Actuators
DANGER! TO AVOID RISK OF INJURY:
...do not permit children to operate the Control Unit or use the Pool/Spa unless they are closely supervised at all times. ...test GROUND FAULT protection regularly. If it fails to reset, DO NOT USE THE POOL or SPA!
Contact a qualified ser
...always disconnect electricity before servicing this control or the equipment connected to it.
vice technician immediately.
READ, FOLLOW & SAVE THIS INSTRUCTION MANUAL
GENERAL INFORMATION
Many of today’s pools and spas utilize the advantages of a single electrical control panel, containing all the necessary components for the safe, cost effective and automatic operation of a pool or spa.
Model RC2263E is designed to operate the shared equipment, like the pump, filter and the heater of a Pool-Spa combination safely from the spa side with only one air button. In addition, the Air Blower of the SPA can be controlled by the same air button as shown in the chart below.
The 24 hour timer turns ON the filter pump and automatically filters and, if so set, heats the pool water on a daily schedule. In addition, by the push of the #3 air button at the spa side, the Control turns ON the pump, the heater and rotates the valves thus allowing the water to circulate in the spa. The Control also features a selector switch for the heater. The switch has three positions and it can be set to hea the pool to tw tion disables the heater. the Control also has terminals for connect­ing a fr trol logic board.
Model RC2263BE is the same as the one described above, except it is built into an 8 circuit 100 Amp. sub-panel.
he Contr
T equipment according to the following table:
t the w
eez
ter either in the spa only or both in the spa and in
a
o different pre-selected temperatures. The third posi-
t to its f
otection ther
e or hea
ol coordinates the operation of the various pool/spa
ter pr
mosta
ilter pump con-
RC2263E
RC2263BE
EQUIPMENT Sequence 1 (Home Position) Sequence 2 Sequence 3 Sequence 4 Filter Pump
One Speed Timer ON/OFF ON ON OFF Low/High Speed Timer Low/Off High High Low
Blower OFF OFF ON ON Valves Set to Pool Circulation Set to Spa Circulation Heater Pool Temperature Setting Spa Temperature Setting
1
IMPORTANT SAFETY INSTRUCTIONS
When installing and operating this Product and other associated equipment, basic safety precautions should always be followed, including the following:
1. Read and follow all instructions.
2. This Control must be installed by a qualified electrician, according to National and Local Electrical Codes.
3. Install this Control not less than 5 feet (3 meters in Canada) from inside edge of pool. USE COPPER CONDUCTORS ONLY.
4. Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors.
5. For control grounding, bonding, installing and the wiring of underwater lights, refer to Article 680 of the National Electrical Code or Article 68 of the Canadian Electrical Code. The Control should not operate any equipment which would cause bodily injury or property damage should it be activated
6. unexpectedly
IMPORTANT: High and low voltage conductors should not occupy the same conduits or compartments.
This Air Control can operate either a 120 volt or 240 volt, single or two speed pump, air blower, together with a gas heater and up to three 24 volt valve actuators. It also has a connection for a freeze or heater protection device to turn ON the pump if needed.
.
READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL
INSTALLATION
1. Follow wiring diagram on Page 4 and prepare your installation layout. Make sure only copper (solid or stranded) conductors are used, properly sized and suitable for the installation. Each piece of equipment must be grounded properly.
Neutral must always be connected to the white lead of the control.
2. Hang Air Control on a flat vertical surface or other support, using hardware suitable for the purpose. Make sure the air button is within the range of the Air Control. NOTE: The optimum range of this Air Control is 100 feet. However, factors beyond control of the manufacturer (like the size of the air pump, the I.D. of the air hose, etc.) will determine the actual distance between the mechanism and the air pump.
3. Prepare the necessary conduit runs, including one for the air hose, terminate them at both ends and pull in the conductors as specified by the installation layout.
IMPORTANT:
SETTING / OPERATING INSTRUCTIONS
Programming Instructions
To Set or Change the Time of Day: To clear entire memor while pressing either the HOUR or MINUTE keys. Continue pressing until the desired number is shown. T
y, press key. Hold down the CLOCK key
hen simply lift finger off the CLOCK key to set.
4. Follow wiring diagram on page 4, make LINE, PUMP, and BLOWER connections in the high voltage compartment as shown. Make sure the installation is securely grounded and bonded, if necessary.
5. Remove screw next to Heater Switch and gain access to printed circuit (P.C.) board assembly in low voltage compartment. Follow wiring diagram on page 4, plug valve actuators into designated sockets on P.C. board and make heater connections to terminals 1, 2 and 3. 2 if heater is single stage. See page 4 for details. Replace P.C. board assembly.
6. Make air hose connections, follow instructions provided with Air Button.
7. Check wiring, tightness of connections and grounding. Close wiring compartment and test installation.
8. Set times, see instructions below.
Place jumper between terminals 1 and
To Set Program (ON/OFF times): Press TIMER key
once to enter into program mode. Display will show "1 ON-- --". Press the HOUR key and then the MINUTE key to select the desired first ON time. Press TIMER k
y once
e
. Displa
y will show "1 OFF -- --". Repeat previous step to select the desired first OFF time. Repeat the entire sequence to complete up to
.
eight total ON/OFF times as desir
ed ming is done, press the CLOCK key then the SELECT key repeatedly until the indicator bar is above the word
O".
UT
"A
w Program:
o Re
T
vie
Pr
TIMER k
ess When done, press CLOCK key to return to the time of day.
When program-
ey repeatedly.
Indicator LED “ON” when connected to power source and contacts are closed
2
Display
Reset port
to cancel all
prior settings
ON/AUT
O/OFF
Select Key
Function Keys
Loading...
+ 2 hidden pages