Intermatic KM2 STu-1G, KM2 SWu-1G, KM2 ST-1G, KM2 ST-2G, KM2 SW-2G Operating Instructions Manual

...
KM2 Series In-Wall Timers
Replaces standard wall switch to provide automatic control of outdoor or indoor lighting, fans, pumps, office machines, and other types of circuits. Captive trippers are easy to set, can’t be lost. 72 trippers provide up to 36 ON/OFF events in 24 hour period. OFF/ON/AUTO over­ride switch provides continuous ON or OFF positions. UL Listed. Easy wiring and installation.
FEATURES
24 hour or 7 day time switch program
Captive trippers with 20 minute switching interval
(2-1/3 hr. for 7 day)
Reliable synchronous timer motor
SPST or SPDT 20A, 1HP @ 120V switch
OFF/ON/AUTO manual switch
Mounts to standard electrical wall boxes
Available with 1, 2, 3, or 4-gang wall plates with toggle switch open-
ings, or 2-gang wall plates with either duplex receptacle or decora­tor opening
Three way (SPDT) switch available
Dual timer allows control of two separate circuits with different time
schedules
UL and Canadian UL Listed
1-gang
SPECIFICATIONS
Clock Input: 120VAC, 60Hz SPST and SPDT Switch Rating: 20A @ 120VAC, 60Hz 2400W Resistive 8A Inductive 1HP @ 120VAC 1350W Tungsten
Environmental Ratings:
Operating Temperature Range:
–40°F to 180°F (–40°C to 85°C) Operating Humidity: 0 - 95% RH, non-condensing
Wiring Connections: Three #14AWG lead wires
ORDERING DATA – 120V, 60Hz Models
24 Hour 7 Day Model Code Model Code Description Switch
KM2 ST-1G KM2 SW-1G single gang 20A, SPST KM2 STu-1G KM2 SWu-1G three-way single gang 20A, SPDT KM2 ST-2G KM2 SW-2G 2-gang/toggle opening 20A, SPST KM2 ST-2R N/A 2-gang/receptacle opening 20A, SPST KM2 ST-2D KM2 SW-2D 2-gang/decorator opening 20A, SPST KM2 ST-3D N/A 3-gang/decorator opening 20A, SPST KM2 ST-3G N/A 3-gang/toggle openings 20A, SPST KM2 ST-4G N/A 4-gang/toggle openings 20A, SPST KM2 STST-2G KM2 SWSW-2G 2-gang/dual timer (2) 20A, SPST
4-gang/toggle
2-gang/toggle
2-gang/decorator
Dual Timer
(2-gang with 2 KM2’s)
Installation
HOT (BLACK)
(RED)
3-Way Switch
(BLUE)
LOAD
NEUTRAL (WHITE)
HOT (BLACK) LOAD (RED)
LOAD
NEUTRAL (WHITE)
1. Read the operating instructions carefully.
2. Check the input and output ratings marked on the unit to make sure this product is suitable for your application.
3. Disconnect power supply prior to installation to pre­vent electrical shock.
4. Damage to the contacts caused by short circuiting will void warranty.
5. Wire in accordance with National and local electri­cal code requirements.
BE SURE ALL CONNECTIONS ARE SECURE. DOUBLE CHECK ALL TWIST-ON WIRE CON­NECTORS.
6. Mount timer into wall box using supplied screws.
7. If timer does not operate, check that the timer’s black wire is connected to hot line and not the load. If nec­essary, reverse connections to red and black wires.
Manual Operation
The slide switch provides manual operation of the load, overriding the timer. If set to the position, the load will be continuously off, and if set to , it will be continuously on. For automatic timed on’s and off’s, the switch must be in the position.
Programming
The timer dial contains 72 “trippers” which, when set at the inner perimeter of the dial, will turn the switch “ON” at the time adjacent to the tripper. The switch will return to the “OFF” position when the timer progresses past the inward trippers.
The 72 trippers allow multiple on/off sequences with a minimum on or off time of 20 min. To program, set all trippers inward for the duration of the on event.
For example, to turn lights on at 5:00pm and off at 11:00pm, leave inward the 18 trippers between 5 and 11 on the “pm” side of the dial. Make sure manual switch is in the position.
NOTE: For any times where “OFF” programming is desired, the trippers must be moved to the outer perimeter of the dial.
Setting The Time
Rotate the dial clockwise until the correct time and “am” or “pm” is opposite the arrow on the plate.
CAUTION: Do not turn dial counter-clockwise, as the timer will be damaged.
ONE YEAR WARRANTY
If this unit fails due to a defect in material or workman­ship within one year after purchase, Intermatic will repair or replace the unit free of charge. This warranty does not apply to damage due to accidents, abuse, mishandling nor to units not used in accordance with directions. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Standard Installation 3-Way Installation
INTERMATIC INCORPORATED
Spring Grove, IL 60081-9698
www.intermatic.com
Wiring Diagrams
Distributed by:
158--00534