Inter-M RM-916 User Manual

OPERATING MANUAL

REMOTE AMPLIFIER WITH ZONE
SELECTOR

RM-916

11

UNPACKING AND INSTALLATION

Although it is neither complicated to install nor difficult to operate your power Amplifier, a few minutes of your time is required to read this manual for a properly wired installation and becoming familiar with its many features and how to use them. Please take a great care in unpacking your set and do not discard the carton and other packing necessary to return your set for when moving your set and are required if it ever becomes necessary to return your set for service. Never place the unit near radiators, in front of heating vents, to direct sun light, in excessive humid or dusty location to avoid early damage and for your years of quality use. Connect your complementary components as illustrated in the following page.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
WARNING
To prevent fire or shock hazard, do not expose the unit to rain or moisture.
This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying the appliance.
Caution: To prevent electric shock do not use this (polarized) plug with
an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure.
Attentions: Pour prévenir les chocs électriques ne pas utiliser cette fiche
polarisée avec un prolongateur, une prise de courant on une autre sortie de courant, sauf si les lames peuvent étre insérées à fond sans en laisser aucune partie à découvert.
22

FEATURES

• SPEAKER LINE CONTROL
Speaker line control can easily be achieved by connecting the RM-916 speaker control terminals to an Inter-M PX-9116 MATRIX unit.
• CHIME
Four tone pre-announcement chime, activ ated b y push button CHIME switch.
• OUTPUT LEVEL METER
Ten segment LED bargraph on the front panel that indicates instantaneous signal output level of the RM-916.
• MIC BROADCASTING
Easy to use, highly sensitive condenser type MIC for clear broadcasting.
•AUXILIARY SIGNAL INPUT
Auxiliary signal input for Cassette Deck or Tuner makes the RM-916 an ideal remote piece of equipment for broadcasting background music.

OPERATING PROCEDURE

1. Switch the RM-916 on with the POWER switch. The POWER LED will illuminate.
2. If the announcement is to be broadcast to one of the sixteen loudspeaker zones, press the corresponding channel switch. The selected channel switch LED will illuminate.
3. If the announcement is to be broadcast to all the sixteen loudspeaker zones, press the ALL call switch. The ALL call switch LED will illuminate.
4. Press the CHIME s witch for the pre-announcement chime, if required.
5. You can now use the CM-916 MIC for broadcasting across the system.
6. Adjust the v olume to its required level using the relev ant MIC, CHIME or AUX control.
7. When the announcement is finished, Turn off all the channel switches (CH1–16) and the ALL call switch to ensure that normal broadcasting can take place. The sixteen channel switch LEDs and the ALL call switch LED will be extinguished.
33

FRONT PANEL CONTROLS

1. MIC INPUT JACK
The CM-916 MIC is connected to this input jack. It’s input sensitivity is –60dB.
2. POWER SWITCH (ON/OFF)
Switches ON and OFF the 24V DC power source.
3. MIC VOLUME
Turn to the right to increase the volume and to the left to decrease the volume.
4. CHIME VOLUME
Turn to the right to increase the volume and to the left to decrease the volume.
5. AUX VOLUME
Turn to the right to increase the volume and to the left to decrease the volume.
6. OUTPUT LEVEL METER
Indicates the signal output level between –18dB and +9dB .
7. SPEAKER CONTROL SWITCH
These switches select one of sixteen loudspeaker zones for the broadcasts.
8. SPEAKER ZONE LED
Visual indication of the selected loudspeaker zone.
9. ALL CALL SWITCH
This switch, when pressed ON, selects all the sixteen loudspeaker zones f or the broadcast.
REMOTE AMPLIFIER WITH ZONE SELECTORRM-916
++
OUTPUT LEVEL
---
369630
CHIME
ALL
POWER
CH 2CH 1 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8
CH 10CH 9 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16
-12-15-
18 +9
TALK
MIC INPUT
POWER
AUX
MIN MAX
MIC
MIN MAX
CHIME
MIN MAX
23456789101112131415161
RM
COM
23456789101112131415161RM
COM
SPEAKER CONTROL
SPEAKER CONTROL
LINE OUT
DC 24V IN
HG
CHG
AUX IN
44
10. ALL CALL LED
Visual indication showing that all the sixteen loudspeaker zones are selected.
11. CHIME SWITCH
This switch, when pressed, will output a four tone pre-announcement chime to the selected loudspeaker zone(s).
12. CHIME SWITCH LED
This LED will illuminate when the chime switch is pressed.
13. POWER LED
This LED will illuminate when the POWER switch is ON.
14. TALK SWITCH
The TALK ON switch activates for the MIC-916 (LED ON).
15. TALK LED
Visual indication of the TALK ON switch.
55

CAUTION FOR RACK ASSEMBLY

1. Ensure that power is switched off bef ore installation and before any wiring is connected to the equipment.
2. Site the equipment in well v entilated places and a void places of high humidity.
3. Whenever possible, fit Inter-M MIC model CM-916. If a Phantom powered MIC is to be used, we recommend that it operates on +5V DC.
4. Please observe wiring polarity when connecting DC Pow er to the equipment.
5. Before connecting to the RM-916 LINE OUT terminals, check and match the incoming wiring for HOT, COLD & GND potential.

CONNECTOR SECTION FUNCTIONS

1. LINE OUTPUT TERMINALS
Connect the line output terminals to the REMOTE INPUT JACK of the Inter-M EMERGENCY PANEL EP-
9216.
2. AUX INPUT TERMINALS
Connect the line output of a Cassette Deck, Tuner or CD player to these terminals. The input sensitivity of the AUX input is –20dB.
3. 24V DC POWER INPUT TERMINALS
Connect the 24V DC OUTPUT of the Inter-M POWER DISTRIBUT OR PD-9359 to these terminals.
4. SPEAKER CONTROL & COM TERMINALS
Connect these speaker control line terminals to the REMOTE 1 or REMOTE 2 inputs of the Inter-M PX-9116 MATRIX unit.
POWER
AUX
MIN MAX
MIC
MIN MAX
CHIME
MIN MAX
MIC INPUT
SPEAKER CONTROL
DC 24VINAUX
IN
+
H
G
15876543211011121314916
RM
COM
GCH
LINE OUT
66

CONNECTIONS

EM RELAY TIMER SW POWER SW
DC OUT
DC IN
NORMAL RELAY EM
SWITCH
RM 1 RM 2 SPEAKER SELECTOR EMG/PANE
L
EXT OUT EXT IN
REMOTE IN 2
TIMER IN AUTO ANN IN
PRE IN
PRE OUT
MATRIX
RM MIC
SW
EXT INT
-12 0
SIREN/VOLUME
SHOCK HAZARD DO NOT OPEN. NO USER SERVICEABLE PARTS INSIDE.DO NOT EXPOSE UNIT TO RAIN OR MOISTURE
WARNING;
RISQUE DE CHOC ELECTRIQ­UE NE PAS OUVRIR.
AVIS;
REMOTE MIC
AUTO. ANN
REMOTE IN 1
+
DC INPUT
24V
CONTROL OUT(TO AUTO ANN)
S/N
POWERPOWE
R
ON
OFF
DIGITAL TUNER
PT-910
12345FM
67890/30AM
PRESETMUTE
DOWN UP MEMOR
Y
SCAN
VOLUM
E
MIN MAX
POWE
R
ON
OFF
PHON
E
PUBLIC ADDRESS LOGIC DOUBLE DECK
PC-9335
OPEN OPEN
LEVEL
dB
-
-13 -8-3 0 +3
REC LEVEL
MIN MAX
RELAYBLANK
A B
RECORDING PLAY
LOGIC DECK
AUTO REVERSE
DECK A DECK B
NOR
MEMOREC
AMS
NOR . DUBBING . HIGH
MOD E
REC PAUSE
REC MUTE MEMOR/PLAY SKIP/B
DECK
A
MIN MAX
AMS AMS AMS
HI
DUBING
SKIPPLAY
RESETCOUNTER
RECORDING PLAY
LOGIC DECK
AUTO REVERSE
DECK
B
OUTPUT LEVEL
MULTIPLE COMPACT DISC PLAYER
CDC-930
TIMER
OFF PLAY
DISC SELECTOR
12345DISC
SKIP
OPEN/CLO SE
ON OFF POWER
dis c
COMPA CT
-SKIP-SEARCHSTOP/CL EAR
PLAY/PA USE
5DISC AUTOMATIC DISC LOADING SYSTEM
PROGRAM REAPET TIMER DISC MEMORY
HIGH DENSITY 1-BIT D/A CONVERTER
RANDOM
MIC INPUT
POWER
AUX
MIN MAX
MIC
MIN MAX
CHIME
MIN MAX
REMOTE AMPLIFIER WITH ZONE SELECTOR
RM-916
23456789101112131415161
RM
COM
23456789101112131415161RM
COM
SPEAKER CONTROL
SPEAKER CONTROL
RM-916 (1)
PT-9107
CDC-9300
PC-9335
POWERPOWE
R
ON
OFF
DIGITAL TUNER
PT-910
12345FM
6789
0/30
AM
PRESETMUTE
DOWN UP MEMOR
Y
SCAN
VOLUM
E
MIN MAX
POWE
R
ON
OFF
PHON
E
PUBLIC ADDRESS LOGIC DOUBLE DECK
PC-9335
OPEN OPEN
LEVEL
dB--13 -8-3 0 +3
REC LEVEL
MIN MAX
RELAYBLANK
A B
RECORDING PLAY
LOGIC DECK
AUTO REVERSE
DECK A DECK B
NOR
MEMOREC
AMS
NOR . DUBBING . HIGH
MOD E
REC PAUSE
REC MUTE MEMOR/PLAY SKIP/B
DECK
A
MIN MAX
AMS AMS AMS
HI
DUBING
SKIPPLAY
RESETCOUNTER
RECORDING PLAY
LOGIC DECK
AUTO REVERSE
DECK
B
OUTPUT LEVEL
MULTIPLE COMPACT DISC PLAYER
CDC-930
TIMER
OFF PLAY
DISC SELECTOR
12345DISC
SKIP
OPEN/CLO SE
ON OFF POWER
dis c
COMPA CT
-SKIP-SEARCHSTOP/CL EAR
PLAY/PA USE
5DISC AUTOMATIC DISC LOADING SYSTEM
PROGRAM REAPET TIMER DISC MEMORY
HIGH DENSITY 1-BIT D/A CONVERTER
RANDOM
MIC INPUT
POWER
AUX
MIN MAX
MIC
MIN MAX
CHIME
MIN MAX
RM-916
RM-916 (2)
PT-9107
CDC-9300
PC-9335
PD-9359
PX-9116
EP-9216
EMERGENCY
AC FUSE 2A/250V
DC FUSE 7A/250V
BATTERY
INPUT
(+)
( )
AC INPUT
230V/50Hz,217VA
GND
(+)
( )
UNSWITCHED
DC OUTPUT 24V
+
-
DC OUT 24V
(RACK ONLY) SWITCHED
5A MAX
(AMP ONLY)
SWITCHED DC OUT 24V
REMOTE
SWCH
SWED 1 (2000W)
SWED 2 (2000W)
SWED 3 (2000W)
UNSWED (700W)
H
G
AUX IN
DC 24V IN
GC
H
LINE OUT
H
G
AUX IN
DC 24V IN
GC
H
LINE OUT
REMOTE AMPLIFIER WITH ZONE SELECTOR
23456789101112131415161
RM
COM
SPEAKER CONTROL
23456789101112131415161RM
COM
SPEAKER CONTROL
77

BLOCK DIAGRAM

SPECIFICATIONS

88
*0dB=0.775Vrms
ELECTRICAL
• Output Level/Impedance........................................................................................................ +4dB/600, BAL
• Input Sensitivity/Impedance
MIC...............................................................................................................................–60dB/600, BAL
AUX ........................................................................................................................–20dB/10K, UNBAL
• Frequency Response (–3dB)....................................................................................................... 20Hz–20KHz
• T.H.D..........................................................................................................................................Less than 0.2%
• S/N...........................................................................................................................................Better than 60dB
• Speaker Control Terminal & Switch. ........................................................................................................16 CH
GENERAL
• Pow er Source .........................................................................................................................................DC 24V
• Weight. ..................................................................................................................1.2Kg (Without Microphone)
• Dimensions...........................................................................................................245(W)
60(H) 205(D)mm

MIC(CM-916) SPECIFICATIONS

*Specifications and design subject to change without notice for improvements.
1. Type : Electric Condenser Microphone
2. Sensitivity : Ç42dB 3dB
3. Impedance : Less than 2.2K Ohm
4. Max Operation Voltage : 10V
5. Standard Operation Voltage : 4.5V
6. Directivity : Omnidirectional
7. Frequency Response : 20~16,000Hz
8. Current Consumption : Max. 0.8mA
C : 16V10µF. RL: 2.2K
Output
+Vs
Ground
C
RL
Term. 1
FET impedance converter
Relative Response (dB)
Frequency (Hz)
ECM unit
Shield case
20
+20
+10
0
–10
–20
–30
50 100 200 500 1000 2000 5000 10000 20000
Term. 2

NOTE

NO: 9007921010
Loading...