Inter-M RM-916 User Manual

0 (0)

OPERATING MANUAL

R E M O T E A M P L I F I E R W I T H Z O N E

SELECTOR

RM-916

1

UNPACKING AND INSTALLATION

Although it is neither complicated to install nor difficult to operate your power Amplifier, a few minutes of your time is required to read this manual for a properly wired installation and becoming familiar with its many features and how to use them. Please take a great care in unpacking your set and do not discard the carton and other packing necessary to return your set for when moving your set and are required if it ever becomes necessary to return your set for service. Never place the unit near radiators, in front of heating vents, to direct sun light, in excessive humid or dusty location to avoid early damage and for your years of quality use. Connect your complementary components as illustrated in the following page.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

WARNING

To prevent fire or shock hazard, do not expose the unit to rain or moisture.

This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

This symbol is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying the appliance.

Caution: To prevent electric shock do not use this (polarized) plug with an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure.

Attentions: Pour prévenir les chocs électriques ne pas utiliser cette fiche polarisée avec un prolongateur, une prise de courant on une autre sortie de courant, sauf si les lames peuvent étre insérées à fond sans en laisser aucune partie à découvert.

2

FEATURES

SPEAKER LINE CONTROL

Speaker line control can easily be achieved by connecting the RM-916 speaker control terminals to an Inter-M PX-9116 MATRIX unit.

CHIME

Four tone pre-announcement chime, activated by push button CHIME switch.

OUTPUT LEVEL METER

Ten segment LED bargraph on the front panel that indicates instantaneous signal output level of the RM-916.

MIC BROADCASTING

Easy to use, highly sensitive condenser type MIC for clear broadcasting.

AUXILIARY SIGNAL INPUT

Auxiliary signal input for Cassette Deck or Tuner makes the RM-916 an ideal remote piece of equipment for broadcasting background music.

OPERATING PROCEDURE

1.Switch the RM-916 on with the POWER switch. The POWER LED will illuminate.

2.If the announcement is to be broadcast to one of the sixteen loudspeaker zones, press the corresponding channel switch. The selected channel switch LED will illuminate.

3.If the announcement is to be broadcast to all the sixteen loudspeaker zones, press the ALL call switch. The ALL call switch LED will illuminate.

4.Press the CHIME switch for the pre-announcement chime, if required.

5.You can now use the CM-916 MIC for broadcasting across the system.

6.Adjust the volume to its required level using the relevant MIC, CHIME or AUX control.

7.When the announcement is finished, Turn off all the channel switches (CH1–16) and the ALL call switch to ensure that normal broadcasting can take place. The sixteen channel switch LEDs and the ALL call switch LED will be extinguished.

Inter-M RM-916 User Manual

3

FRONT PANEL CONTROLS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC 24V IN

 

AUX IN

 

 

 

 

 

MIC INPUT

 

 

 

 

 

 

 

SPEAKER CONTROL

 

 

 

 

RM

 

 

H

G

 

 

 

 

 

 

1

 

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16 COM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER

 

 

 

 

 

1

 

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

RM

 

 

 

MIC

CHIME

 

AUX

 

 

 

 

 

 

 

 

 

SPEAKER CONTROL

 

 

 

 

COM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

C

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINE OUT

MIN

MAX

MIN

MAX

MIN

MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RM-916

REMOTE AMPLIFIER WITH ZONE SELECTOR

 

 

POWER

 

 

 

 

 

 

 

- 18 - 15 -

OUTPUT LEVEL

+ 3 +6 +9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHIME

 

 

12 - 9 -

6

 

- 3

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CH 1

CH 2

 

 

 

CH 3

 

 

CH 4

 

 

 

CH 5

 

CH 6

CH 7

 

 

CH 8

 

 

ALL

 

 

CH 9

CH 10

 

 

 

CH 11

 

 

CH 12

 

CH 13

 

CH 14

CH 15

 

 

CH 16

 

TALK

 

 

1.MIC INPUT JACK

The CM-916 MIC is connected to this input jack. It’s input sensitivity is –60dB.

2.POWER SWITCH (ON/OFF)

Switches ON and OFF the 24V DC power source.

3.MIC VOLUME

Turn to the right to increase the volume and to the left to decrease the volume.

4.CHIME VOLUME

Turn to the right to increase the volume and to the left to decrease the volume.

5.AUX VOLUME

Turn to the right to increase the volume and to the left to decrease the volume.

6.OUTPUT LEVEL METER

Indicates the signal output level between –18dB and +9dB.

7.SPEAKER CONTROL SWITCH

These switches select one of sixteen loudspeaker zones for the broadcasts.

8.SPEAKER ZONE LED

Visual indication of the selected loudspeaker zone.

9.ALL CALL SWITCH

This switch, when pressed ON, selects all the sixteen loudspeaker zones for the broadcast.

Loading...
+ 7 hidden pages