Interlogix TruVision TVB-2402, TruVision TVB-2404, TruVision TVB-4404, TruVision TVB-2405, TruVision TVB-4405 Installation Manuals

...
Page 1
TruVision High
Definition TVI
Bullet
Camera Installation
Gu
TVB
-2402/TVB-4402
TVB
-2404/TVB-4404
TV
B-2405/TVB-4405
P/N 1073164-EN • REV A • ISS 31MAR16
Page 2
Page 3
Installation Guide 1
Contents
Product overview 2 Camera description 4 Installation 7
Built-in heater in the TVB-2405/4405
camera 11
Program 11 Menu trees 17 Specifications 19 Legal and regulatory information 21
Page 4
2 Installation Guide
Product overview
This is the TruVision High Definition TVI Bullet Camera Installation Guide for models TVB­2402/TVB-4402, TVB-2404/TVB-4404 and TVB­2405/TVB-4405. This guide describes a standard installation.
Package contents
Camera with power
and video output cables
4 screws and 4
anchors for wall or ceiling installation
Back box
Screws M4.8 × 18,
4 pcs to attach the back box
Page 5
Installation Guide 3
Template
Hex wrench
Installation guide
WEEE disposal
sheet
CD
BNC monitor output cable
Hole A: for cables routed through the wall
A
Drill Template
1
1
1
2
2
2
2
Screw hole 1: for integrative bracket
Screw hole 2: for conduit back box
Page 6
4 Installation Guide
Camera description
1. CVBS output (black)
2. TVI output (grey)
3. Power cable
4. Camera body
5. Sun shield
6. Lens
7. Mounting bracket
8. Back box
Note:
Please check the camera output settings before setting up a system. The TVI video output can be only connected to a DVR with a TVI signal input. The CVBS output supports a standard CVBS monitor (or test monitor), an encoder or a DVR.
8
2
7
3
1
5
6
4
Page 7
Installation Guide 5
For 720P VF bullet cameras, TVB-2402 / TVB-4402, the CVBS and TVI output can not be used at the same time. Use the built-in switch to select the camera video output.
For 1080P VF bullet cameras, such as TVB­2404/TVB-4404 and TVB-2405/TVB-4405, the built­in switch is used to enable/disable the WDR feature. When the WDR feature is enabled, the CVBS output will be blocked.
Figure 1: TVB-2402 /TVB-4402
Focus
Zoom
Menu button
Switch (Up= CVBS/
Down = TVI)
BNC output
Page 8
6 Installation Guide
Figure 2: TVB-2404 /TVB-4404
Focus
Zoom
Menu button
Switch (Up= CVBS/
Down = WDR)
BNC output
Figure 3: TVB-2405 /TVB-4405
BNC output
Menu button
Switch (Up= CVBS/
Down = WDR)
Page 9
Installation Guide 7
Installation
To install the camera:
1. Using the template, place it level against the mounting surface and mark the position of the mounting holes.
2. Following all local safety regulations, drill and prepare the mounting holes.
3. As an optional step, install the back box on the wall.
Hole A: for cables routed through the wall
A
Drill Template
1
1
1
2
2
2
2
Screw hole 1: for integrative bracket
Screw hole 2: for conduit back box
Page 10
8 Installation Guide
4. Route the cables to the cable hole and connect the corresponding cables. Using a 75-ohm coaxial video cable, connect the camera TVI video output to a TVI DVR, and connect a 12 VDC or 24 VAC power supply to the power cable.
5. Secure the camera to the ceiling or wall with the screws provided.
Page 11
Installation Guide 9
6. Loosen the three screws on the mounting bracket and adjust the camera angle according
to the figure below to the optimum position. Tighten the screws after completing the adjustment.
Page 12
10 Installation Guide
7. Zoom and focus adjustment
a) Manually adjust the zoom and focus on
TVB-2402/TVB-4402 and TVB-2404/TVB-
4404.
b) TVB-2405/TVB-4405 has a motorized lens.
Please adjust its zoom and focus by using
360°
90°
360°
Page 13
Installation Guide 11
the zoom and focus buttons on the PTZ panel of a connected recorder or controllor.
Built-in heater in the TVB­2405/4405 camera
The TVB-2405/4405 camera has a built-in heater that works within the temperature range of -40 and +60 °C (-40 to +140 °F). The heater only works at 24 VAC.
When the camera initially starts up, the heater will start to work automatically when the temperature is below -10 °C (14 °F). However, with continuous operation the heater will not work until the internal temperature drops below -30°C (-22 °F).
Note: The TVB-2402/4402 and TVB-2404/4404 operating temperature range is between -30 and +60 °C (-22 to +140 °F).
Program
Once the camera hardware has been installed, you can then program the camera.
Page 14
12 Installation Guide
CVBS
WDR
The camera has a built-in OSD button and supports UtC (Up-to-Coax) control over both CVBS and TVI outputs.
Using the buttons
Please press the Menu button to call up the OSD menu and select an OSD item.
Press the button up/down to move the cursor up or down to an OSD item.
Press the button left/right to move the cursor left or right to adjust the value of a selected OSD item.
Using a TVI output
Programming over the camera’s TVI output can be
done via a TVI DVR.
Connect the TVI cable to the DVR, as shown below.
Page 15
Installation Guide 13
Figure 4: TVI cable connection
Access the PTZ menu of the connected DVR, set
the TruVision-Coax protocol and use the PTZ control panel to configure the camera.
Click Iris+ to access to the camera OSD menu and select an OSD item.
Click the directional buttons UP or DOWN to move
the cursor up or down to an OSD item.
Click the directional buttons LEFT or RIGHT to
move cursor left or right to adjust the value of a selected OSD item.
Note: TVB-2405/TVB-4405 has a motorized lens. Please use the ZOOM and FOCUS buttons to adjust its zoom and focus.
For more details, refer to the TVI DVR user manual.
Page 16
14 Installation Guide
Using a CVBS output
A TVS-C200 (purchase separately) can be used to program the camera over its CVBS output, not the
TVI video output.
Connect a monitor and the TVS-C200 controller (if required) as shown below.
Figure 5: CBSC cable connections
Press the OK button of the TVS-C200 for a few seconds until you see the OSD menu display on the
monitor. You can also use the OK button to select an OSD item.
Page 17
Installation Guide 15
Use the directional buttons to move cursor and adjust value.
For more details, refer to the TVS-C200 user manual.
TVB-2402/TVB-4402 camera
The camera has CVBS and TVI dual video outputs. Set the built-in switch to CVBS to view the program
on a standard monitor.
The TVI is blocked until the camera configuration is complete and the switch is reset to TVI.
See Figure 5 on page 17 to see the menu tree.
TVB-2404/TVB-4404 and TVB-2405/TVB-
4405 cameras
The cameras have CVBS and TVI dual video outputs. The built-in switch is for WDR/CVBS selection. Set the built-in switch to CVBS to view the setup menu on a standard monitor.
Page 18
16 Installation Guide
When the programing is finished, you can change the switch setting to WDR to enable the WDR
feature. In such case, the CVBS output will be
disabled.
If the switch is set to CVBS, the WDR feature is disabled and the camera has both CVBS and TVI output available.
See Figure 6 on page 18 to see the menu tree.
Page 19
Installation Guide 17
Menu trees
Figure 6: TVB-2402/TVB-4402 menu tree
Page 20
18 Installation Guide
Figure 7: TVB-2404/TVB-4404 and TVB­2405/TVB-4405 menu tree
Page 21
Installation Guide 19
Specifications
Power supply
12 VDC / 24 VAC
Current
TVB-2402 / TVB-4402:
12 VDC: Max. 333 mA 24 VAC: Max. 250 mA TVB-2404/TVB-4404: 12 VDC: Max. 420 mA 24 VAC: Max. 250 mA TVB-2405/TVB-4405: 12 VDC: Max. 1A 24 VAC: Max. 500 mA
Power consumption
TVB-2402/TVB-4402:
12 VDC: Max. 4W 24 VAC: Max. 6W TVB-2404/TVB-4404: 12 VDC: Max. 5W 24 VAC: Max. 6W TVB-2405/TVB-4405: 12 VDC: Max. 12W 24 VAC: Max. 12W
Page 22
20 Installation Guide
Weight (net)
TVB-2402/TVB-4402:
860 g / 1.89 lb. (without back box) 1075 g / 2.36 lb. (with back box) TVB-2404/TVB-4404: 860 g / 1.89 lb. (without back box) 1075 g / 2.36 lb. (with back box) TVB-2405/TVB-4405: 880 g / 1.94 lb. (without back box) 1095 g / 2.41 lb. (with back box)
Dimensions
105 × 94.7 × 265.4 mm / 4.13 ×
3.74 × 10.4 in. (without back box
105 × 94.7 × 301.4 mm / 4.13 ×
3.74 × 11.86 in. (with back box)
Page 23
Installation Guide 21
Legal and regulatory
information
Copyright:
© 2016 United Technologies Corporation. All rights reserved.
Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation.
Trademarks and patents:
Trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products.
Manufacturer:
Interlogix 2955 Red Hill Avenue, Costa Mesa, CA 92626-5923, USA Authorized EU manufacturing representative:
UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, The Netherlands
Certification:
FCC compliance: Class A
Class A: This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is op
erated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause
Page 24
22 Installation Guide
harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
ACMA compliance
Notice! This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Canada
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-0330 du Canada.
European Union directives:
12004/108/CE (EMC directive): Hereby, UTC Fire & Security declares
that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC.
2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info.
Contact information:
For contact information, see www.interlogix.com or www.utcfssecurityproducts.eu
Page 25
Page 26
Page 27
Page 28
Loading...