P/N 1073164-EN • REV A • ISS 31MAR16

Installation Guide 1
Contents
Product overview 2
Camera description 4
Installation 7
Built-in heater in the TVB-2405/4405
camera 11
Program 11
Menu trees 17
Specifications 19
Legal and regulatory information 21

2 Installation Guide
Product overview
This is the TruVision High Definition TVI Bullet
Camera Installation Guide for models TVB2402/TVB-4402, TVB-2404/TVB-4404 and TVB2405/TVB-4405. This guide describes a standard
installation.
Package contents
Camera with power
and video output
cables
4 screws and 4
anchors for wall or
ceiling installation
Back box
Screws M4.8 × 18,
4 pcs to attach the
back box

Installation Guide 3
Template
Hex wrench
• Installation guide
• WEEE disposal
sheet
CD
• BNC monitor
output cable
Hole A: for cables routed through the wall
A
Drill Template
1
1
1
2
2
2
2
Screw hole 1: for integrative bracket
Screw hole 2: for conduit back box

4 Installation Guide
Camera description
1. CVBS output
(black)
2. TVI output (grey)
3. Power cable
5. Sun shield
6. Lens
7. Mounting bracket
8. Back box
Note:
Please check the camera output settings before
setting up a system. The TVI video output can be
only connected to a DVR with a TVI signal input.
The CVBS output supports a standard CVBS
monitor (or test monitor), an encoder or a DVR.

Installation Guide 5
For 720P VF bullet cameras, TVB-2402 / TVB-4402,
the CVBS and TVI output can not be used at the
same time. Use the built-in switch to select the
camera video output.
For 1080P VF bullet cameras, such as TVB2404/TVB-4404 and TVB-2405/TVB-4405, the builtin switch is used to enable/disable the WDR feature.
When the WDR feature is enabled, the CVBS
output will be blocked.
Figure 1: TVB-2402 /TVB-4402
Focus
Zoom
Menu button
Switch (Up= CVBS/
Down = TVI)
BNC output

6 Installation Guide
Figure 2: TVB-2404 /TVB-4404
Focus
Zoom
Menu button
Switch (Up= CVBS/
Down = WDR)
BNC output
Figure 3: TVB-2405 /TVB-4405
BNC output
Menu button
Switch (Up= CVBS/
Down = WDR)

Installation Guide 7
Installation
To install the camera:
1. Using the template, place it level against the
mounting surface and mark the position of the
mounting holes.
2. Following all local safety regulations, drill and
prepare the mounting holes.
3. As an optional step, install the back box on the
wall.
Hole A: for cables routed through the wall
A
Drill Template
1
1
1
2
2
2
2
Screw hole 1: for integrative bracket
Screw hole 2: for conduit back box

8 Installation Guide
4. Route the cables to the cable hole and connect
the corresponding cables. Using a 75-ohm
coaxial video cable, connect the camera TVI
video output to a TVI DVR, and connect a
12 VDC or 24 VAC power supply to the power
cable.
5. Secure the camera to the ceiling or wall with
the screws provided.

Installation Guide 9
6. Loosen the three screws on the mounting
bracket and adjust the camera angle according
to the figure below to the optimum position.
Tighten the screws after completing the
adjustment.

10 Installation Guide
7. Zoom and focus adjustment
a) Manually adjust the zoom and focus on
TVB-2402/TVB-4402 and TVB-2404/TVB-
4404.
b) TVB-2405/TVB-4405 has a motorized lens.
Please adjust its zoom and focus by using

Installation Guide 11
the zoom and focus buttons on the PTZ
panel of a connected recorder or controllor.
Built-in heater in the TVB2405/4405 camera
The TVB-2405/4405 camera has a built-in heater
that works within the temperature range of -40 and
+60 °C (-40 to +140 °F). The heater only works at
24 VAC.
When the camera initially starts up, the heater will
start to work automatically when the temperature is
below -10 °C (14 °F). However, with continuous
operation the heater will not work until the internal
temperature drops below -30°C (-22 °F).
Note: The TVB-2402/4402 and TVB-2404/4404
operating temperature range is between -30 and
+60 °C (-22 to +140 °F).
Program
Once the camera hardware has been installed, you
can then program the camera.

The camera has a built-in OSD button and supports
UtC (Up-to-Coax) control over both CVBS and TVI
outputs.
Using the buttons
Please press the Menu button to call up the OSD
menu and select an OSD item.
Press the button up/down
to move the cursor up or
down to an OSD item.
Press the button left/right
to move the cursor left or
right to adjust the value of
a selected OSD item.
Using a TVI output
Programming over the camera’s TVI output can be
done via a TVI DVR.
Connect the TVI cable to the DVR, as shown below.

Installation Guide 13
Figure 4: TVI cable connection
Access the PTZ menu of the connected DVR, set
the TruVision-Coax protocol and use the PTZ
control panel to configure the camera.
Click Iris+ to access to the camera OSD menu and
select an OSD item.
Click the directional buttons UP or DOWN to move
the cursor up or down to an OSD item.
Click the directional buttons LEFT or RIGHT to
move cursor left or right to adjust the value of a
selected OSD item.
Note: TVB-2405/TVB-4405 has a motorized lens.
Please use the ZOOM and FOCUS buttons to
adjust its zoom and focus.
For more details, refer to the TVI DVR user manual.

14 Installation Guide
Using a CVBS output
A TVS-C200 (purchase separately) can be used to
program the camera over its CVBS output, not the
TVI video output.
Connect a monitor and the TVS-C200 controller (if
required) as shown below.
Figure 5: CBSC cable connections
Press the OK button of the TVS-C200 for a few
seconds until you see the OSD menu display on the
monitor. You can also use the OK button to select
an OSD item.

Installation Guide 15
Use the directional buttons to move cursor and
adjust value.
For more details, refer to the TVS-C200 user
manual.
TVB-2402/TVB-4402 camera
The camera has CVBS and TVI dual video outputs.
Set the built-in switch to CVBS to view the program
on a standard monitor.
The TVI is blocked until the camera configuration is
complete and the switch is reset to TVI.
See Figure 5 on page 17 to see the menu tree.
TVB-2404/TVB-4404 and TVB-2405/TVB-
4405 cameras
The cameras have CVBS and TVI dual video
outputs. The built-in switch is for WDR/CVBS
selection. Set the built-in switch to CVBS to view
the setup menu on a standard monitor.

16 Installation Guide
When the programing is finished, you can change
the switch setting to WDR to enable the WDR
feature. In such case, the CVBS output will be
disabled.
If the switch is set to CVBS, the WDR feature is
disabled and the camera has both CVBS and TVI
output available.
See Figure 6 on page 18 to see the menu tree.

Installation Guide 17
Menu trees
Figure 6: TVB-2402/TVB-4402 menu tree

18 Installation Guide
Figure 7: TVB-2404/TVB-4404 and TVB2405/TVB-4405 menu tree

Installation Guide 19
Specifications
TVB-2402 / TVB-4402:
12 VDC: Max. 333 mA
24 VAC: Max. 250 mA
TVB-2404/TVB-4404:
12 VDC: Max. 420 mA
24 VAC: Max. 250 mA
TVB-2405/TVB-4405:
12 VDC: Max. 1A
24 VAC: Max. 500 mA
12 VDC: Max. 4W
24 VAC: Max. 6W
TVB-2404/TVB-4404:
12 VDC: Max. 5W
24 VAC: Max. 6W
TVB-2405/TVB-4405:
12 VDC: Max. 12W
24 VAC: Max. 12W

TVB-2402/TVB-4402:
860 g / 1.89 lb. (without back box)
1075 g / 2.36 lb. (with back box)
TVB-2404/TVB-4404:
860 g / 1.89 lb. (without back box)
1075 g / 2.36 lb. (with back box)
TVB-2405/TVB-4405:
880 g / 1.94 lb. (without back box)
1095 g / 2.41 lb. (with back box)
105 × 94.7 × 265.4 mm / 4.13 ×
3.74 × 10.4 in. (without back
box)
105 × 94.7 × 301.4 mm / 4.13 ×
3.74 × 11.86 in. (with back box)

information
Copyright:
© 2016 United Technologies Corporation. All rights reserved.
Interlogix is part of UTC Climate, Controls & Security, a unit of
United Technologies Corporation.
Trademarks and patents:
Trade names used in this document may be trademarks or
registered trademarks of the manufacturers or vendors of the
respective products.
Manufacturer:
Interlogix
2955 Red Hill Avenue, Costa Mesa, CA 92626-5923, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, The Netherlands
Certification:
Class A: This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
op
erated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause

harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
interference at his own expense.
ACMA compliance
Notice! This is a Class A product. In a domestic environment this
product may cause radio interference in which case the user may
be required to take adequate measures.
Canada
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme
NMB-0330 du Canada.
European Union directives:
12004/108/CE (EMC directive): Hereby, UTC Fire & Security declares
that this device is in compliance with the essential requirements and
other relevant provisions of Directive 2004/108/EC.
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent new
equipment, or dispose of it at designated collection
points. For more information see:
www.recyclethis.info.
Contact information:
For contact information, see www.interlogix.com or
www.utcfssecurityproducts.eu