Interlogix Sentrol RCR Series, Sentrol RCR-A, Sentrol RCR-C Installation Instructions Manual

Page 1
EXHIBIT B – User Manual
FCC ID# CGGAA2
Page 2
Sentrol RCR
Range-Controlled Radar Detector
Models: RCR-A (Form A)
Installation Instructions
Description
The RCR detector combines range-controlled radar (RCR) technology with a passive infrared (PIR) system to increase false alarm immunity by allowing it to sense human-sized objects within a specified range. Both the RCR and PIR systems must be triggered to set off an alarm, unless in Microwave only mode.
The detector is designed to use a 12VDC power supply pro­vided by a UL Listed alarm control panel.
R
P M T
R P S
Figure 1 - Detector (exploded)
M O C
NO R P
TM
Features
The detector provides the following features:
· High-security mode - Internal jumper allows you to disable the PIR, and use the RCR system only to detect intruders faster. This mode can be used for covert installations (mounted behind ceiling panels or walls).
· Selectable range up to 35 feet - Internal jumper allows radar range selection to optimize coverage.
· LED indicator - A multi-color LED provides detector status.
· Tamper switch (RCR-C only) - Activated when the pins on
the circuit board are removed from the terminal sockets on the base.
T op Vie w
9'
0'
9'
Side View
6.9'
0'
18'
18'
9' 18' 27' 35'
27'
27'
35'
35'
°
90
RCR Viewing Area
PIR Viewing Area
Parts
The following parts are included with the detector:
· RCR detector
· 1 screw to join the case halves
· 3 factory-installed jumpers
Selecting a Location for the Detector
The detector can be mounted in a corner or on a flat wall. Use the following guidelines to determine the best location to install the detector:
· Mount the detector so the expected movement of an intruder is across the detection pattern. See Figure 2.
· Mount the detector on a stable surface 7 to 9 feet high.
· DO NOT mount the detector within 2 feet of any metallic
objects.
· DO NOT place any objects in front of the detector that may prevent a clear line of sight. (Not applicable in RCR only mode.)
· Avoid locations that expose the detector to possible false alarm sources such as:
 Moving or vibrating objects (fans, pulleys, conveyor belts)
 Electronic fields (electric motors, high voltage equipment)
 Water spray or corrosive environments
 Heat sources in the field of view (heaters, radiators)
 Windows in the field of view
 Strong air drafts on the detector (fans, air conditioners)
· When installing multiple detectors:
 DO NOT mount detectors facing each other
 Use the 9-foot range when mounting detectors back to back
 Mount them at least 20 feet apart
 Use shorter range settings to avoid overlapping radar coverage
Figure 2 - RCR and PIR Coverage Patterns
Sentrol RCR
1
Page 3
Installing the Detector
All wiring must conform to National Electric Code (NEC) and/or local codes having jurisdiction.
Important: DO NOT use this device for safety
interlock applications.
Use the following steps to install the detector:
1. Run the security system wiring to the detector location.
2. To remove the front cover/electronic module, press down on the lever at the bottom of the unit and pull the cover off. Remove the nameplate and loosen the screw if necessary. To remove the nameplate, insert a small screwdriver into one of the nameplate side slots and gently push in on the nameplate. See Figure 1.
CAUTION! Use anti-static precautions when handling
the circuit board.
3. If necessary, set the jumpers on the circuit board. See Setting the Jumpers.
4. Remove the appropriate wiring and mounting knockout holes from the back cover. The detector can be mounted on a flat wall or in a corner. See Figure 3.
5. Pull the wires through the knockout holes and use the two screws provided to attach the base to the wall. Use screw anchors if necessary.
6. Strip 1/4 inch of insulation from each wire.
Spare
RCR-C only
Figure 3 - Detector Base
Terminal sockets
7. Run each wire through the strain relief and under the appro­priate screw terminals on the base and tighten the screws. See Figure 3.
8. Line up the tabs on the bottom of the cover/electronic module with the corresponding tabs on bottom of the base and snap the cover/electronic module firmly down onto the base.
9. Tighten the screw and replace the nameplate. See Figure 1.
10. Apply power. The green LED should light for approximately 25 seconds and then go out.
11. Walk test the coverage pattern as follows:
 Walk throughout the intended coverage area.
 Verify the detector alarms. See Understanding the LED.
Note: Most units walk test more accurately if the person
testing waits 10 seconds between tripping the unit and walking again. This allows the detector to stabilize between trips.
J4
Microwave only
J2
Range
LED Disable
J3
2
Figure 4 - Main Circuit Board
Sentrol RCR
Page 4
DEL sutatS
deRdnamralanisirotcetedehT.noitcetedRCRdnaRIP
.dehctiwssahyalereht
neerG.)mralaon(ylnonoitcetedRIP
wolleY.)mralaon(ylnonoitcetedRCR
Setting the Jumpers
The detector provides jumpers to select the detection range and PIR and LED operation. See Figure 4.
J2 Range - Use the jumper to cover the center pin and the pin indicating the desired range. No jumper = 27 feet and under.
9 feet and under 18 feet and under
9'
18'35'
9'
18'35'
Maintaining the Detector
When installed and used properly, the detector provides years of service with minimal maintenance. You should walk test the detector annually to ensure proper operation.
When the cover is removed, power is interrupted to the sensor. Once the cover has been replaced, the green LED will illuminate for 15 seconds while the sensor warms up. After the green LED goes off, wait one minute and walk test the sensor.
27'
27'
27 feet and under 35 feet and under (factory default)
35'
9'
18'
27'
35'
9'
18'
27'
Important: You need to set J2 as close to the intended
coverage range as possible. Overshooting the coverage area may cause false alarms.
J3 LED - ON = LED enabled (factory default)
OFF = LED disabled
J4 PIR - ON = RCR Microwave only
OFF = PIR enabled (factory default)
Understanding the LED
The multi-color LED located on the bottom of the detector indicates the status of the unit as described in the following table.
In RCR microwave only mode:
DEL sutatS
deR.noitcetedevaworcimRCR
SB01 Swivel Mount Bracket
For ceiling-mount applications that require 90 degree coverage, an optional ceiling-mount swivel bracket (SB01) is available from Interlogix. See Figure 5.
Sentrol RCR
Figure 5 - SBO1 Swivel-Mount Bracket
3
Page 5
Specifications
Input voltage.......................8.5 to 18 VDC (UL: 10 to 16VDC)
Typical current..................................................................20mA
Maximum current..............................................................27mA
Electrical configuration.....................................RCR-A: Form A
RCR-C: Form C
Relay rating..............................RCR-A: 200VDC, 500mA max.
RCR-C: 200VDC, 250mA max.
Tamper (RCR-C only)........................................100ma, 50VDC
Detection range..............................................35' (10.7 m) x 90°
Target velocity..............................................0.5 ft/sec to 5 ft/sec
Alarm duration....................................................................5 sec
Mounting height.......................................7' to 9' (2.1 to 2.75 m)
Operating temperature........................32° to 122°F (0° to 50°C)
Relative humidity...............................5 to 95% non-condensing
Dimensions:
Width..................................................................2.8" (7.1 cm)
Depth..................................................................2.3" (5.7 cm)
Height..................................................................5.1" (13 cm)
Weight......................................................................6 oz (170 g)
Color......................................................................................white
Field wiring size.......................................................16-24 AWG
FCC Compliance
This device complies with Part 15 of the FCC rules. Opera­tion is subject to the following two conditions:
(1) this device may not cause harmful interference
(2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC ID:
Product Ordering
rebmuNledoM noitpircseD
A-RCRyalerAmrofhtiwrotcetedradardellortnoc-egnaR C-RCR stcatnocrepmatdnayalerCmrofhtiwrotcetedradardellortnoc-egnaR
seirosseccA
10BStekcarbtnuom-leviwS
4
1035261 Rev A 04/01