Interlogix 711U, 721U, 731U Specsheet

FireworX Fire & Life Safety
Conventional Initiating Devices
Overview
The GE photoelectric smoke detector is an interchangable head and base detector with a light-scattering optical sensor that provides outstanding stability and excellent response to a wide range of fires.
A pulsed infrared LED light source and a high-speed photodiode sensing element are housed in an omnidirectional sensing chamber which is protected by an insect screen. The chamber is not affected by ambient light. For easy cleaning, the detector features a field-re­placeable optical chamber.
The Model 711UT, 721UT and 741UT photoelectric detectors include integral fixed temperature heat detectors.
GE 700 Series smoke detectors are the industry’s first conventional self-diagnostic detectors specifically designed for the demands of commercial and industrial environments. If the detector drifts out of its UL Listed sensitivity range or fails internal diagnostics, the alarm LED flashes once a second to indicate trouble. This meets NFPA 72 field sensitivity testing requirements without the need for external meters.
Additional diagnostic information is activated by applying a magnet near the detector’s integral reed switch. This initiates a self-diag­nostic routine and provides visual indication of sensitivity level, or if service is required. The magnet test causes the LED to blink. The number of blink counts corresponds to a smoke detector sensitivity range.
And, if they become dirty over time, the 700 Series detectors auto­matically adjust the alarm threshold through built-in drift compen­sation.
Standard Features
Self-diagnostic capabililty continually monitors operation
Automatic drift compensation
Field-replaceable optical chamber
Low-profile design blends into the ceiling
Advanced nuisance alarm immunity
Extensive two-wire compatibility listings
Two- and Four-Wire Self-Diagnostic Smoke Detectors
700 Series
Compatibility
Heads Bases
711U 701U, 702E, 702U 731U 702RU 741U 702U
Engineering Specifications
The GE 700 Series photoelectric smoke detector, is a low-profile, self-diagnostic, two-wire or four-wire detector that monitors its own sensitivity and operational status. The detector meets NFPA 72 field sensitivity testing requirements without the need for external meters. Built-in drift compensation automatically adjust the sensitivity if the detector gets dirty. Normal sensing occurs every 9 seconds. This rate doubles when a signal exceeding the alarm threshold value is sensed. Two additional successive signals above the threshold level initiate an alarm. The patented optical sensing chamber is field replaceable, allowing quick and easy cleaning and maintenance.
A manually operated switch between terminals 1 and 2 shall establish continuity across the alarm, initiating circuit at initial installation. The switch automatically open when a detector head is plugged in. If a detector head is removed from service, the switch will be reset using a small screwdriver, thus re-establishing circuit continuity.
Technical Specifications
Electrical
Voltage 8.5 — 33VDC, non polarity sensitive Maximum ripple (peak to peak) 10% (Vp - p) Typical standby current (24V) 70μA Typical alarm current (24V) up to 60 mA max, if not limited by control panel Relay contacts 2A @ 30VDC, 1A @ 120 VAC Photoelectric Sensitivity 2.85%, + 0.37, – 1.00% Operating temperature 32°F to 120°F (0°C to 49°C) Operating humidity range 0 to 95% Non-condensing RFI immunity 20 V/m min; 0-1000 MHz Remote LED output current 5 mA min, 8.5 mA max Drift compensation adjustment 1.0%/ft. max
Environmental
Heat Sensor Ratings (721UT, 741UT) Fixed 135°F/ Rate of rise 15° Maximum wind velocity 300 ft/min or Field wiring size 12-24 AWG Remote test input (721UT) 100 ohm max Reset voltage 2.5V max Reset time 1 second max UL two-wire compatibility identifier S10A (711U, 711UT, 721UT) S11A (731U)
Physical
Color White head and base Detector head dimensions 4” D x 1.75” (4.44 cm) H Detector packaging 10 detectors per carton Base packaging 10 bases per carton Base dimensions 702E: 4” D, 0.6” (10 x 1.3 cm) H
701U, 702U: 6” D, 0.6” x 1.3 cm) H
Total height, (head and base) 1.98” (5 cm) H
Regulations
Listing UL 268, FM, CSFM, MEA approved
Ordering Information
Photoelectric Heads 711U, 711UT, 721UT, 731U, 741U Photoelectric Bases 701U, 702E, 702U, 702RE, 702RU