July 10, 2007 1.2 Added AC Power consumption tables to section 2.1.
Modifications
ii Revision 1.2
Intel® Storage Server SSR212MC2 TPS Disclaimers
Disclaimers
Information in this document is provided in connection with Intel® products. No license, express
or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel
assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to
sale and/or use of Intel products including liability or warranties relating to fitness for a particular
purpose, merchantability, or infringement of any patent, copyright or other intellectual property
right. Intel products are not intended for use in medical, life saving, or life sustaining
applications. Intel may make changes to specifications and product descriptions at any time,
without notice.
Designers must not rely on the absence or characteristics of any features or instructions marked
"reserved" or "undefined." Intel reserves these for future definition and shall have no
responsibility whatsoever for conflicts or incompatibilities arising from future changes to them.
The Intel® Storage Server SSR212MC2 may contain design defects or errors known as errata
that may cause the product to deviate from published specifications. Current characterized
errata are available on request.
Intel system boards contain a number of high-density VLSI and power delivery components that
need adequate airflow to cool. Intel’s own chassis are designed and tested to meet the
intended thermal requirements of these components when the fully integrated system is used. It
is the responsibility of the system integrator that chooses not to use Intel developed system
building blocks to consult vendor datasheets and operating parameters to determine the amount
of air flow required for their specific application and environmental conditions. Intel Corporation
cannot be held responsible if components fail or the system board does not operate correctly
when used outside any of their published operating or non-operating limits.
Intel, Pentium, Itanium, and Xeon are trademarks or registered trademarks of Intel Corporation.
*Other brands and names may be claimed as the property of others.
List of Tables Intel® Storage Server SSR212MC2 TPS
This page intentionally left blank
viii Revision 1.2
Intel® Storage Server SSR212MC2 Feature Summary
1. Feature Summary
This Technical Product Specification provides detailed information about the hardware
components of the Intel® Storage Server SSR212MC2.
The Intel® Storage Server SSR212MC2 is available in two configuration/sku’s: with or without
an Intel® RAID Controller SRCSAS144E (product codes SSR212MC2R and SSR212MC2,
respectively), and includes a 2U chassis, Intel
one or two Dual-Core (5100 sequence) or Quad-Core (5300 sequence) Intel
processors, twelve SATA/SAS hard disk drive carriers, dual Intel® PRO/1000 Network
connections, and a single 850 W power supply (dual redundant 1+1 capable).
Intel®-based system boards and chassis have feature sets designed to support the high-density
storage market.
®
Server Board S5000PSL with support for either
®
Xeon®
Figure 1. Intel® Storage Server SSR212MC2
Revision 1.2 1
Feature Summary Intel® Storage Server SSR212MC2
Table 1: Intel® Storage Server SSR212MC2 Hardware Feature Summary
Raw Storage Capacity
External Drive Bays
Hard Disk Drive
Supported (external
storage)
Hard Disk Drive
Supported (internal
boot)
Processor
Memory Capacity
Memory Type
DIMM Slots
Enclosure Controller
Temperature Sensor
Network Connectivity
Front Panel
Expandable to 3.0 TB – using twelve 250 GB drives.
Expandable to 4.8 TB – using twelve 400 GB drives.
Expandable to 6.0 TB – using twelve 500 GB drives.
Expandable to 9.0 TB – using twelve 750 GB drives
Expandable to 12.0 TB – using twelve 1 TB drives
12 Hot Pluggable.
3.5 inch SATA , SAS.
NOTE: For specific drive family and capacities supported, please
refer to the SSR212MC2 Tested Hardware and OS List (THOL).
2.5 inch SATA, SAS.
NOTE: For specific drive family and capacities supported, please
refer to the SSR212MC2 Tested Hardware and OS List (THOL).
Support for one or two Dual-Core (5100 sequence) or Quad-Core (5300
sequence) Intel® Xeon® processors.
NOTE: The Intel® Storage Server SSR212MC2 does not ship with
processors installed. Please refer to the SSR212MC2 Configuration
Guide for a list of supported processors.
Expandable to 32 GB maximum.
NOTE: The Intel® Storage Server SSR212MC2 does not ship with
memory installed. Please refer to the SSR212MC2 Tested Memory
List for a list of supported memory.
FBDIMM.
Eight.
On-board Vitesse** VSC410 micro-controller.
Two temperature sensors are located on the backplane and baseboard
that allows drive cage temperature monitoring by enclosure management.
Dual GB Ethernet.
Buttons and Switches
LEDs
Hard Disk Drive Carrier
LEDs
Back Panel
Buttons and Switches
I/O Connectors
Power Receptacle
Chassis
Form Factor
Height
Width
Depth
3x: Power, Reset, ID.
3x: Fault, ID, Power.
2x: Activity, Fault.
2x: ID LED button, NMI button.
1x DB-9 Serial port, 2x RJ-45 Ethernet ports, 1x DB-15 Video connector,
4x 2.0 USB port, 1x Stacked PS/2 Mouse/Keyboard connector.
1x IEC AC per installed power supply module.
2U rack-mount chassis
87.9 mm, 3.46 in
447 mm, 17.6 in (across body of chassis)
707 mm, 27.83 in (from rack posts to max extremity of chassis)
2 Revision 1.2
Intel® Storage Server SSR212MC2 Feature Summary
Weight
Color
Rack Support
System Cooling
Fans
Power
Configuration
Environment
Ambient Temperature
Relative Humidity
Acoustics
Electrostatic Discharge
Safety Compliance
As shipped (zero drives): approximately 20 kg, 44 pounds
Fully configured (twelve drives): approximately 30 kg, 66 pounds
Shipping container: 3.2 kg, 7 pounds
Black
Rail mount, compatible with four-post rack mount only, and compliant to
the SSI Server Rack specification and EIA 310-D.
Chassis includes ten hot-swappable redundant system fans for cooling the
hard drives, baseboard and SAS Host Bus Adapter (HBA) card.
850 W continuous, 1+1 redundant power supplies. Intel Storage System
SSR212MC2 ships with one 850W power supply
Operating (system): 10 degrees Celsius to +35 degrees Celsius, with
maximum change not to exceed 10 degrees Celsius per hour; nonoperating (system): -40 degrees Celsius to +70 degrees Celsius.
Non-operating: 90% @ 35 degrees Celsius non-condensing
< 7.0 BA (rack-mount) in an idle state in an normal office environment
(23 degrees Celsius)
15 KV per Intel test specification
Argentina
Canada
China
Europe, CE Mark
Germany
International
Nordic Countries
Russia
United States
Electromagnetic Capability (Class A) (EMC)
Australia/New Zealand
Canada
China
Europe, CE Mark
International
Japan
Korea
Russia
Taiwan
United States
RoHS
IRAM
UL60950 – CSA (60950 (UL and cUL)
GB4943- CNCA Certification
EN60950 (complies with73/23/EEC)
GS License
IEC60950 (CB Report and Certificate)
EMKO-TSE (74-SEC) 207/94
GOST 50377-92
UL– 60950 – CSA 60950 (UL and cUL)
AS/NZS 3548 (based on CISPR 22)
ICES-003
GB 9254 - CNCA Certification
GB 17625 - (Harmonics) CNCA Certification
EN55022; EN55024 & EN61000-3-2;-3-3 (complies with 89/336/EEC)
CISPR 22
VCCI
RRL, MIC 1997-41 & 1997-42
GOST 29216-91 & 50628-95
CNS13438
FCC, Part 15
European Directive 2002/95/EC
Revision 1.2 3
Feature Summary Intel® Storage Server SSR212MC2
1.1 System Components
A block diagram of the SSR212MC2R sku (with RAID card) is shown below.
Figure 2. Intel® Storage Server SSR212MC2R Block Diagram
4 Revision 1.2
Intel® Storage Server SSR212MC2 Feature Summary
A block diagram of the SSR212MC2 sku (without RAID card) is shown below.
“Pass Thru” Cable
SAS /SATA
SAS / SATA
SAS / SATA
SAS / SATA
1.5 / 3Gbps (Data)
4 LANE
4 Lane
4 LANE
10 x FAN (5 banks)
individually hot plugable
SAS /SATA
SAS /SATA
Presence
SAS / SATA
SAS / SATA
SAS / SATA
SAS / SATA
Cold
SAS / SATA
SAS / SATA
Drive
Pin11
U
S
B
12
12
PWR FAULT ID
PWR
RST ID
12 x Drive
Activity
12 x Drive
Fault
BACK
PLANE
SMBus or BMC
4 LANE4 LANE
+12V
Ops Panel
Sensor
PMC
24 port
4 Lane4 Lane
SAS
High Power
Connector
High Power
Connector
EXPANDER
10 x PRESENT
Alarm
SES
SES
SPI
FLASH
12
12
+5V+5V
+12V
Enclosure Management Card
Z
Temp
I
F
Flex Cable
10 x FAIL LED
GPIO
I2C
Master
Memory
EEPROM
5 x PWM
FAN
CONTROL
VSC410
Enclosure
Controller
I2C
Master
GPIO
Expander
LEDs
(Ops)
10 x TACHO
I2C
Slave
I2C
Slave
Temp
Sensor
Remote
(Ops)
serial
ICE
IPMI
Control SSI
Header
RS232USB 2.0
23
POWER &
PSU Status
ZIF
Power Button
Reset Button
Intrusion Switch
Rear ID LED
High Power
Connector
3 x +12V Rails
+5V, +3.3V Rails
+5V Standby
4 x PSU Status
internal COM header
Figure 3. Intel® Storage Server SSR212MC2 Block Diagram
PSMI
PDB
ATX
PSU 850W
Dual Redundant
Revision 1.2 5
Feature Summary Intel® Storage Server SSR212MC2
The components included with the storage system are diagrammed below.
Figure 4. System Components
6 Revision 1.2
Intel® Storage Server SSR212MC2 Feature Summary
1.2 System Board Feature Set
The Intel® Server Board S5000PSL provides the following feature set, as implemented in the
Intel Storage System SSR212MC2:
Table 2: Intel® Server Board S5000PSL features
Feature Description
Processors Socket J (771-pin LGA sockets) supporting one or two Dual-Core (5100 sequence)
or Quad-Core (5300 sequence) Intel
1066 MHz and 1333 MHz.
NOTE: The Intel® Storage Server SSR212MC2 does not include processors. See the SSR212MC2
Configuration Guide for a list of supported processors.
240-pin DDR2-533 and DDR2-677 FBDIMMs can be used.
NOTE: The type of memory selected (DDR2-533 or DDR2-667) should be matched with the type of
processor used. See the SSR212MC2 Tested Memory List for a list of supported memory modules.
Chipset Intel® S5000P chipset, consisting of:
®
Intel
5000P Memory Controller Hub, and Intel® ESB2-E I/O Controller.
Video 2D Graphics Accelerator: ATI* ES1000 Video Controller w/ 16MB of video DDR
SDRAM memory.
Connectors/
Headers
Stacked PS/2* ports for keyboard and mouse
Stacked video / DB9 serial port A connector
Two RJ45 / 2xUSB connectors for 10 / 100 / 1000 Mb and USB 2.0 support
One USB 2x5 pin header, which supports two USB ports
One USB port Type A connector
One DH10 serial port B header
Two SATA connectors and four SAS connectors
One ATA100 40-pin connector
SSI-compliant front panel header
SSI-compliant 24-pin main power connector, supporting the ATX-12 V standard