1Intel® Storage System SSR212MC2– (Server)IntelSSR212MC2
1 (Select one)
Intel® HDD Backplane – SR1500 1U SAS active
IntelASR1500SASBP
Intel® HDD Backplane – SR1500 1U SATA/SAS
passive
4 GB minimum Memory
1 – 12 (250GB
minimum)
1SAS or SATA 2.5-inch hard drive (to be used as
1 Gigabit Ethernet Switch
SAS or SATA 3.5-inch hard drives
internal boot drive)
Table 1 – Intel® Storage System SSR212MC2R Configuration Hardware
IntelASR1500PASBP
Any supported Please refer to the Tested
Any supported Please refer to the Server Hard
Any supported
ny Supported
Software Used in the Installation
ItemVersionManufacturerComment
StorTrends® iTX
Installation CD
2.7.1019American Megatrends (AMI)
Memory List at
http://www.intel.com/support/m
otherboards/server/s5000pal/s
b/CS-022919.htm
Drive Validation Test Report at
http://www.intel.com/support/m
otherboards/server/sb/CS-
025416.htm
Please refer to the Server Hard
Drive Validation Test Report at
http://www.intel.com/support/m
otherboards/server/sb/CS-
025416.htm
Table 2 - Software Bill of Materials
Hardware Used in the Installation
ItemVersionManufacturerComment
External CD-ROM
Drive with USB
connector
N/A(none recommended)
Table 3 -Hardware Bill of Materials
To be used when loading
StorTrends iTX Installation CD
About StorTrends® iTX
StorTrends® iTX 2.7 Dual Dialect Storage Software provides both file and block-based
storage functionality in a single, intuitive software stack, enabling businesses to utilize
existing Ethernet networks to simplify data management and reduce storage expenditures.
Designed for enterprise-level high availability and disaster recovery, it is cost-effective,
scalable, and suitable for both novice and advanced users. StorTrends® iTX 2.7 allows
7
StorTrends® iTX Installation and Login
Intel® Server System SSR212MC2
customers to enjoy the advantages of the storage centralization and scalability of IP-based
Storage Area Networks, and the ease of use and file-sharing of Network Attached Storage,
on a single platform at an attractive price.
For more information on StorTrends® iTX, please visit the StorTrends web site at
http://www.StorTrends.com.
Obtaining Software
To request a copy of the 45-day StorTrends iTX Evaluation Kit, or to purchase a copy of
StorTrends iTX, please contact the AMI Storage Sales Department toll-free at 1-800-U-BUY-
AMI (1-800-828-9264). Alternatively, to place a request for an Evaluation Kit, you may
complete the Evaluation Kit Request Form at www.stortrends.com with your complete
mailing address and contact information. Please allow 5-7 days for mail delivery of
Evaluation Kits, depending on your location.
For interested overseas customers, please contact AMI’s US Headquarters at the phone
number and email listed above, so that we may connect you with your regional AMI overseas
office.
Additional product documentation, including copies of the StorTrends iTX/ManageTrends Set
up Guide, User Guide, Product Data Sheets, Whitepapers and much more are available
online at www.ami.com.
Finally, please refer to the documentation included in the StorTrends iTX Evaluation Kit CD or
contact an AMI Storage Sales Representative at 1-800-U-BUY-AMI for more information and
assistance with the recommended evaluation procedures for StorTrends iTX.
Software Environment
StorTrends iTX is based on a Linux kernel and operates through the intuitive
ManageTrends® web-based user interface, as well as through a versatile command-line
interface (CLI) environment.
The ManageTrends GUI is customizable and features several different “themes”, familiar
icons and an organizational layout that is amenable to both novice and advanced users
alike.
8
StorTrends® iTX Installation and Login
Intel® Server System SSR212MC2
StorTrends® iTX Installation
Overview
Use the StorTrends iTX Installation CD from AMI to install the StorTrends iTX software on to
your Intel® Storage Server SSR212MC2. An external USB CD-ROM drive (not included) must
be attached to one of the USB ports on the Intel® Storage Server SSR212MC2 (located in
the rear of the device and front left handle) to do so. Once the StorTrends iTX Installation CD
is loaded into the CD-ROM drive and the Intel® Storage Server SSR212MC2 is set to boot
from the CD, the Install Wizard will automatically begin. Follow the instructions listed during
the installation to complete the installation procedure. The StorTrends iTX software
installation is a relatively fast process that should not take more than 30 minutes.
Once StorTrends iTX software installation is complete, StorTrends iTX will display a prompt to
log in (using the default user name and password). At that time, the initial storage
configuration of the Intel® Storage Server SSR212MC2 can begin.
This document outlines the StorTrends iTX software installation and the initial storage
configuration process (through the use of either the Quick Start Setup Wizard or the
Advanced Setup Wizard) of the Intel® Storage Server SSR212MC2 in greater detail.
STOP!
READ THE INTEL® STORAGE SERVER SSR212MC2 / SSR212MCR QUICK START USER’S
GUIDE PRIOR TO BEGINNING THE STORTRENDS ITX INSTALLATION. IT IS A PRINTED
PIECE OF PAPER THAT SHOULD HAVE BEEN SHIPPED WITH THE INTEL® STORAGE
SERVER SSR212MC2.
THIS GUIDE DESCRIBES HOW TO INSTALL THE STORTRENDS ITX SOFTWARE ON THE
INTEL® STORAGE SERVER SSR212MC2 ONLY.
THIS GUIDE DOES NOT DESCRIBE HOW TO INSTALL CPU, MEMORY, HARD DISK
DRIVES OR OTHER HARDWARE COMPONENTS. SEE THE INTEL® STORAGE SERVER
SSR212MC2 / SSR212MCR QUICK START USER’S GUIDE FOR MORE INFORMATION.
AT LEAST ONE (1) NOTEBOOK HARD DISK DRIVE MUST BE INSTALLED IN YOUR
INTEL® SERVER SYSTEM SSR212MC2 IN ORDER TO INSTALL STORTRENDS ITX.
STORTRENDS ITX WILL ATTEMPT TO INSTALL ITSELF ONTO THE INTERNAL
NOTEBOOK HARD DISK DRIVE (S) IN THE INTEL® STORAGE SERVER. THE INTEL®
SERVER SYSTEM SSR212MC2 SUPPORTS UP TO TWO NOTEBOOK HARD DISK
DRIVES. STORTRENDS ITX WILL AUTOMATICALLY DETECT WHETHER ONE OR TWO
NOTEBOOK HARD DISK DRIVES ARE PHYSICALLY INSTALLED.
9
StorTrends® iTX Installation and Login
Intel® Server System SSR212MC2
IF THERE IS ONLY ONE NOTEBOOK HARD DISK DRIVE INSTALLED, A MESSAGE
STATING, “WARNING!!! DETECTED A SINGLE OS DISK FOR THE STORTRENDS ITX
INSTALLATION. ANY OS DISK FAILURE WILL RESULT IN THE SYSTEM BECOMING
UNUSABLE. CHOOSE “YES” TO CONTINUE, “NO” TO EXIT FROM THE INSTALLATION”
WILL BE DISPLAYED
IF TWO NOTEBOOK HARD DISK DRIVES ARE INSTALLED, STORTRENDS ITX WILL
AUTOMATICALLY DETECT THEM AND WILL MIRROR THE INSTALLATION OF ITSELF
OVER BOTH HARD DISK DRIVES. PRIOR TO BEGINNING THE INSTALLATION, THE
FOLLOWING MESSAGE, “DETECTED MULTIPLE DISKS. THE OS WILL BE INSTALLED ON
A RAID 1 ARRAY” WILL BE DISPLAYED
IT IS RECOMMENDED THAT TWO HARD DISK DRIVES BE PRESENT IN THE SYSTEM
FOR INSTALLATION OF STORTRENDS ITX.
IN ORDER TO INSTALL STORTRENDS ITX, AN EXTERNAL USB CD-ROM DRIVE
MUST BE ATTACHED TO THE SYSTEM. THE APTIO SETUP UTILITY (AMIBIOS)
MUST BE CONFIGURED TO BOOT FROM THIS USB CD-ROM DRIVE.
10
StorTrends® iTX Installation and Login
Intel® Server System SSR212MC2
Remove Any PCI NIC Add-on Cards
STOP!
IF ADDITIONAL NIC CARDS ARE PRESENT IN THE SYSTEM, THEY MUST BE REMOVED
BEFORE PROCEEDING WITH THE INSTALLATION.
Attach a Keyboard, Monitor and External USB CD-ROM Drive
Attach a keyboard, monitor and external USB CD-ROM drive to the Intel® Server System
SSR212MC2 (See the Intel® Storage Server SSR212MC2 / SSR212MCR Quick Start User’s
Guide folded sheet for more information). Power on the Intel® Server System SSR212MC2
and insert the StorTrends iTX Installation CD into the external USB CD-ROM drive.
Installation Procedure
StepDescription
1
11
StorTrends® iTX Installation and Login
Intel® Server System SSR212MC2
StepDescription
Once the keyboard, monitor and external USB CD-ROM Drive have been attached,
power on the Intel® Server System SSR212MC2.
2Enter the Aptio® Setup Utility (AMIBIOS) to configure the system to boot from the
StorTrends iTX Installation CD. The Intel® Server System SSR212MC2 takes
approximately one and a half minutes to get to the screen that prompts to enter
SETUP.
When prompted with, “Press <F2> to enter setup, <F12> Network boot,”
press the <F2> key on the keyboard.
Version X.XX.XXX. Copyright (C) 2005-2XXX American Megatrends, Inc.
Press <F2> to enter setup, <F12> Network Boot
StepDescription
3If performed successfully, the Aptio Setup Utility screen should display. If not, reset the
power on the Intel® Server System SSR212MC2 and start over.
Aptio Setup Utility - Copyright (C) 2005-2007 American Megatrends, Inc.
Main Advanced Security Server Management Boot Options Boot Manager
Logged in as Administrator
Platform ID
System BIOS
Version
Build Date
Processor
Intel (R) Xeon (R) CPU
Core Frequency
Count
Memory
Size
Quiet Boot
POST Error Pause
System Date
System Time
Version X.XX.XXXX, Copyright (C) 2005-2007 American Megatrends, Inc.
XXXXXXXX
XXXXXXX.XXX.XX.XX.XXXX
MM/DD/YEAR
XXXX @ X.XX GHz
X.XX GHz
X
X GB
[Disabled]
[Disabled]
[Mon MM/DD/YEAR]
[HH:MM:SS]
[Enabled] - Display the logo
screen during POST.
[Disabled] - Display the
diagnostic screen during POST.
Select Screen
Select Item
Change Value
+ / -
Select Field
Enter
General Help
F1
Optimized Defaults
F9
Save and Exit
F10
Exit
ESC
12
StorTrends® iTX Installation and Login
Intel® Server System SSR212MC2
StepDescription
4Using the <RIGHT ARROW> key, select Boot Manager. Using the <UP ARROW> and
<DOWN ARROW> keys, select the USB CD-ROM Drive. Press the <ENTER> key to
boot from the StorTrends iTX Installation CD.
Aptio Setup Utility - Copyright (C) 2005-2007 American Megatrends, Inc.
Main Advanced Security Server Management Boot Options Boot Manager
BRANDNAME CD-ROM USBDRIVE
#0400 ID02 LUN0 ATA NOTEBOOKHDD
IBA GE Slot 0501 vXXXX
[EFI Shell]
Version X.XX.XXXX, Copyright (C) 2005-2007 American Megatrends, Inc.
Select this option to boot
now.
Note: This list is not the
system boot option order. Use
the Boot Options menu to view
and configure the system boot
option order.
Select Screen
Select Item
Change Value
+ / -
Select Field
Enter
General Help
F1
Optimized Defaults
F9
Save and Exit
F10
Exit
ESC
Note:Make sure that the proper menu is selected. A common error is to select theBoot Options menu instead of the Boot Manager menu.
StepDescription
5If performed successfully, the Welcome to AMI StorTrends iTX screen should display.
If not, reset the power on the Intel® Server System SSR212MC2 and start over.
Press the <ENTER> key to continue.
American Megatrends Inc
----------------------------------
Welcome to AMI Stortrends ITX.
To install on 3200i/1100i/Intel SSR212MC2, press the <ENTER> key.
To install on Intel Helena Island(SS4200-E), type helena and press the <ENTER> key.
boot: _
StepDescription
13
Loading...