Intel SSR212MC2 User Manual

A
MI StorTrends® iTX
Installation and Login
Intel® Storage System SSR212MC2
Recipe ID: 27AMIX46INTC000000-01
StorTrends® iTX Installation and Login Intel® Server System SSR212MC2
WWW.intel.com/go/esaa
The information contained in this document is provided for informational purposes only and represents the current view of Intel Corporation
(“Intel”) and its contributors ("Contributors") on, as of the date of publication. Intel and the Contributors make no commitment to update the
information contained in this document, and Intel reserves the right to make changes at any time, without notice.
DISCLAIMER. THIS DOCUMENT, IS PROVIDED “AS IS.” NEITHER INTEL, NOR THE CONTRIBUTORS MAKE ANY REPRESENTATIONS OF
ANY KIND WITH RESPECT TO PRODUCTS REFERENCED HEREIN, WHETHER SUCH PRODUCTS ARE THOSE OF INTEL, THE
CONTRIBUTORS, OR THIRD PARTIES. INTEL, AND ITS CONTRIBUTORS EXPRESSLY DISCLAIM ANY AND ALL WARRANTIES, IMPLIED
OR EXPRESS, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR ANY PARTICULAR
PURPOSE, NON-INFRINGEMENT, AND ANY WARRANTY ARISING OUT OF THE INFORMATION CONTAINED HEREIN, INCLUDING
WITHOUT LIMITATION, ANY PRODUCTS, SPECIFICATIONS, OR OTHER MATERIALS REFERENCED HEREIN. INTEL, AND ITS
CONTRIBUTORS DO NOT WARRANT THAT THIS DOCUMENT IS FREE FROM ERRORS, OR THAT ANY PRODUCTS OR OTHER
TECHNOLOGY DEVPSLOPED IN CONFORMANCE WITH THIS DOCUMENT WILL PERFORM IN THE INTENDED MANNER, OR WILL BE
FREE FROM INFRINGEMENT OF THIRD PARTY PROPRIETARY RIGHTS, AND INTEL, AND ITS CONTRIBUTORS DISCLAIM ALL LIABILITY
THEREFOR.
INTEL, AND ITS CONTRIBUTORS DO NOT WARRANT THAT ANY PRODUCT REFERENCED HEREIN OR ANY PRODUCT OR TECHNOLOGY
DEVPSLOPED IN RELIANCE UPON THIS DOCUMENT, IN WHOLE OR IN PART, WILL BE SUFFICIENT, ACCURATE, RELIABLE, COMPLETE,
FREE FROM DEFECTS OR SAFE FOR ITS INTENDED PURPOSE, AND HEREBY DISCLAIM ALL LIABILITIES THEREFOR. ANY PERSON
MAKING, USING OR SELLING SUCH PRODUCT OR TECHNOLOGY DOES SO AT HIS OR HER OWN RISK.
Licenses may be required. Intel, its contributors and others may have patents or pending patent applications, trademarks, copyrights or other
intellectual proprietary rights covering subject matter contained or described in this document. No license, express, implied, by estoppel or
otherwise, to any intellectual property rights of Intel or any other party is granted herein. It is your responsibility to seek licenses for such
intellectual property rights from Intel and others where appropriate.
Limited License Grant. Intel hereby grants you a limited copyright license to copy this document for your use and internal distribution only.
You may not distribute this document externally, in whole or in part, to any other person or entity.
LIMITED LIABILITY. IN NO EVPSNT SHALL INTEL, OR ITS CONTRIBUTORS HAVPS ANY LIABILITY TO YOU OR TO ANY OTHER THIRD
PARTY, FOR ANY LOST PROFITS, LOST DATA, LOSS OF USE OR COSTS OF PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES,
OR FOR ANY DIRECT, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF YOUR USE OF THIS DOCUMENT OR
RELIANCE UPON THE INFORMATION CONTAINED HEREIN, UNDER ANY CAUSE OF ACTION OR THEORY OF LIABILITY, AND
IRRESPECTIVPS OF WHETHER INTEL, OR ANY CONTRIBUTOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
THESE LIMITATIONS SHALL APPLY NOTWITHSTANDING THE FAILURE OF THE ESSENTIAL PURPOSE OF ANY LIMITED REMEDY.
Intel, the Intel logo, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and
other countries.
*Other names and brands may be claimed as the property of others.
Copyright © 2007, Intel Corporation. All Rights Reserved.
StorTrends® iTX Installation and Login
Intel® Server System SSR212MC2
Contents
CONTENTS ............................................................................................................5
HARDWARE COMPONENTS................................................................................7
SOFTWARE USED IN THE INSTALLATION......................................................... 7
HARDWARE USED IN THE INSTALLATION........................................................ 7
ABOUT STORTRENDS® ITX ................................................................................ 7
Obtaining Software ...........................................................................................................................8
Software Environment........................................................................................................... ...........8
STORTRENDS® ITX INSTALLATION...................................................................9
Overview ............................................................................................................................................9
Remove Any PCI NIC Add-on Cards.............................................................................................11
Attach a Keyboard, Monitor and External USB CD-ROM Drive..................................................11
Installation Procedure ....................................................................................................................11
Get the IP address...........................................................................................................................15
Connecting to the StorTrends® iTX Storage Appliance from another system ........................17
Logging on to the StorTrends® iTX Storage Appliance .............................................................17
USING THE QUICK START SETUP WIZARD..................................................... 19
Step One: Quick Start Setup Wizard.............................................................................................20
Step Two: RAID Level.....................................................................................................................20
Step Three: SAN or NAS or Both...................................................................................................21
Step Four: Allocating Space..........................................................................................................22
Step Five: Summary View ..............................................................................................................23
Step Six: All Done No Errors..........................................................................................................26
USING THE ADVANCED SETUP WIZARD.........................................................27
StorTrends® iTX Installation and Login Intel® Server System SSR212MC2
Step One: Advanced Wizard..........................................................................................................27
Step Two: Create a New Storage Pool..........................................................................................28
Step Three: Select Pool........................................................................................................ ..........28
Set the RAID Levels........................................................................................................................29
Type in the Storage Pool’s Name..................................................................................................30
Step Four: Configure SAN Volume................................................................................................30
Enter Volume Name ........................................................................................................................31
Enter Volume Size...........................................................................................................................31
Select Thin or Exact Provisioning.................................................................................................32
Select SAN as the Dialect Type .....................................................................................................32
Create Target and Target Name.....................................................................................................32
Step Five: Configure NAS Volume ................................................................................................32
Enter Volume Name ........................................................................................................................33
Enter Volume Size...........................................................................................................................33
Select Thin or Exact Provisioning.................................................................................................33
Create Share and Share Name.......................................................................................................34
Step Six: Summary View and Status.............................................................................................34
Step Seven: All Done No Errors ....................................................................................................35
APPENDIX A: STORAGE APPLIANCE CONFIGURATION................................36
APPENDIX B: UPDATING AN EVALUATION LICENSE .................................... 37
ADDITIONAL DOCUMENTATION.......................................................................40
StorTrends® iTX Installation and Login
A
Intel® Server System SSR212MC2
Hardware Components
Quantity Item Manufacturer Model
1 Intel® Storage System SSR212MC2– (Server) Intel SSR212MC2
1 (Select one)
Intel® HDD Backplane – SR1500 1U SAS active
Intel ASR1500SASBP
Intel® HDD Backplane – SR1500 1U SATA/SAS passive
4 GB minimum Memory
1 – 12 (250GB minimum)
1 SAS or SATA 2.5-inch hard drive (to be used as
1 Gigabit Ethernet Switch
SAS or SATA 3.5-inch hard drives
internal boot drive)
Table 1 – Intel® Storage System SSR212MC2R Configuration Hardware
Intel ASR1500PASBP
Any supported Please refer to the Tested
Any supported Please refer to the Server Hard
Any supported
ny Supported
Software Used in the Installation
Item Version Manufacturer Comment
StorTrends® iTX Installation CD
2.7.1019 American Megatrends (AMI)
Memory List at http://www.intel.com/support/m otherboards/server/s5000pal/s b/CS-022919.htm
Drive Validation Test Report at http://www.intel.com/support/m otherboards/server/sb/CS-
025416.htm
Please refer to the Server Hard Drive Validation Test Report at http://www.intel.com/support/m otherboards/server/sb/CS-
025416.htm
Table 2 - Software Bill of Materials
Hardware Used in the Installation
Item Version Manufacturer Comment
External CD-ROM Drive with USB connector
N/A (none recommended)
Table 3 -Hardware Bill of Materials
To be used when loading StorTrends iTX Installation CD
About StorTrends® iTX
StorTrends® iTX 2.7 Dual Dialect Storage Software provides both file and block-based storage functionality in a single, intuitive software stack, enabling businesses to utilize existing Ethernet networks to simplify data management and reduce storage expenditures. Designed for enterprise-level high availability and disaster recovery, it is cost-effective, scalable, and suitable for both novice and advanced users. StorTrends® iTX 2.7 allows
StorTrends® iTX Installation and Login Intel® Server System SSR212MC2
customers to enjoy the advantages of the storage centralization and scalability of IP-based Storage Area Networks, and the ease of use and file-sharing of Network Attached Storage, on a single platform at an attractive price.
For more information on StorTrends® iTX, please visit the StorTrends web site at
http://www.StorTrends.com.
Obtaining Software
To request a copy of the 45-day StorTrends iTX Evaluation Kit, or to purchase a copy of
StorTrends iTX, please contact the AMI Storage Sales Department toll-free at 1-800-U-BUY-
AMI (1-800-828-9264). Alternatively, to place a request for an Evaluation Kit, you may
complete the Evaluation Kit Request Form at www.stortrends.com with your complete
mailing address and contact information. Please allow 5-7 days for mail delivery of
Evaluation Kits, depending on your location.
For interested overseas customers, please contact AMI’s US Headquarters at the phone
number and email listed above, so that we may connect you with your regional AMI overseas
office.
Additional product documentation, including copies of the StorTrends iTX/ManageTrends Set
up Guide, User Guide, Product Data Sheets, Whitepapers and much more are available
online at www.ami.com.
Finally, please refer to the documentation included in the StorTrends iTX Evaluation Kit CD or
contact an AMI Storage Sales Representative at 1-800-U-BUY-AMI for more information and
assistance with the recommended evaluation procedures for StorTrends iTX.
Software Environment
StorTrends iTX is based on a Linux kernel and operates through the intuitive
ManageTrends® web-based user interface, as well as through a versatile command-line
interface (CLI) environment.
The ManageTrends GUI is customizable and features several different “themes”, familiar
icons and an organizational layout that is amenable to both novice and advanced users
alike.
StorTrends® iTX Installation and Login
Intel® Server System SSR212MC2
StorTrends® iTX Installation
Overview
Use the StorTrends iTX Installation CD from AMI to install the StorTrends iTX software on to
your Intel® Storage Server SSR212MC2. An external USB CD-ROM drive (not included) must
be attached to one of the USB ports on the Intel® Storage Server SSR212MC2 (located in
the rear of the device and front left handle) to do so. Once the StorTrends iTX Installation CD
is loaded into the CD-ROM drive and the Intel® Storage Server SSR212MC2 is set to boot
from the CD, the Install Wizard will automatically begin. Follow the instructions listed during
the installation to complete the installation procedure. The StorTrends iTX software
installation is a relatively fast process that should not take more than 30 minutes.
Once StorTrends iTX software installation is complete, StorTrends iTX will display a prompt to
log in (using the default user name and password). At that time, the initial storage
configuration of the Intel® Storage Server SSR212MC2 can begin.
This document outlines the StorTrends iTX software installation and the initial storage
configuration process (through the use of either the Quick Start Setup Wizard or the
Advanced Setup Wizard) of the Intel® Storage Server SSR212MC2 in greater detail.
STOP!
READ THE INTEL® STORAGE SERVER SSR212MC2 / SSR212MCR QUICK START USER’S
GUIDE PRIOR TO BEGINNING THE STORTRENDS ITX INSTALLATION. IT IS A PRINTED
PIECE OF PAPER THAT SHOULD HAVE BEEN SHIPPED WITH THE INTEL® STORAGE
SERVER SSR212MC2.
THIS GUIDE DESCRIBES HOW TO INSTALL THE STORTRENDS ITX SOFTWARE ON THE
INTEL® STORAGE SERVER SSR212MC2 ONLY.
THIS GUIDE DOES NOT DESCRIBE HOW TO INSTALL CPU, MEMORY, HARD DISK
DRIVES OR OTHER HARDWARE COMPONENTS. SEE THE INTEL® STORAGE SERVER
SSR212MC2 / SSR212MCR QUICK START USER’S GUIDE FOR MORE INFORMATION.
AT LEAST ONE (1) NOTEBOOK HARD DISK DRIVE MUST BE INSTALLED IN YOUR INTEL® SERVER SYSTEM SSR212MC2 IN ORDER TO INSTALL STORTRENDS ITX.
STORTRENDS ITX WILL ATTEMPT TO INSTALL ITSELF ONTO THE INTERNAL
NOTEBOOK HARD DISK DRIVE (S) IN THE INTEL® STORAGE SERVER. THE INTEL®
SERVER SYSTEM SSR212MC2 SUPPORTS UP TO TWO NOTEBOOK HARD DISK
DRIVES. STORTRENDS ITX WILL AUTOMATICALLY DETECT WHETHER ONE OR TWO
NOTEBOOK HARD DISK DRIVES ARE PHYSICALLY INSTALLED.
StorTrends® iTX Installation and Login Intel® Server System SSR212MC2
IF THERE IS ONLY ONE NOTEBOOK HARD DISK DRIVE INSTALLED, A MESSAGE
STATING, “WARNING!!! DETECTED A SINGLE OS DISK FOR THE STORTRENDS ITX
INSTALLATION. ANY OS DISK FAILURE WILL RESULT IN THE SYSTEM BECOMING
UNUSABLE. CHOOSE “YES” TO CONTINUE, “NO” TO EXIT FROM THE INSTALLATION
WILL BE DISPLAYED
IF TWO NOTEBOOK HARD DISK DRIVES ARE INSTALLED, STORTRENDS ITX WILL
AUTOMATICALLY DETECT THEM AND WILL MIRROR THE INSTALLATION OF ITSELF
OVER BOTH HARD DISK DRIVES. PRIOR TO BEGINNING THE INSTALLATION, THE
FOLLOWING MESSAGE, “DETECTED MULTIPLE DISKS. THE OS WILL BE INSTALLED ON
A RAID 1 ARRAY” WILL BE DISPLAYED
IT IS RECOMMENDED THAT TWO HARD DISK DRIVES BE PRESENT IN THE SYSTEM
FOR INSTALLATION OF STORTRENDS ITX.
IN ORDER TO INSTALL STORTRENDS ITX, AN EXTERNAL USB CD-ROM DRIVE
MUST BE ATTACHED TO THE SYSTEM. THE APTIO SETUP UTILITY (AMIBIOS)
MUST BE CONFIGURED TO BOOT FROM THIS USB CD-ROM DRIVE.
10
StorTrends® iTX Installation and Login
Intel® Server System SSR212MC2
Remove Any PCI NIC Add-on Cards
STOP!
IF ADDITIONAL NIC CARDS ARE PRESENT IN THE SYSTEM, THEY MUST BE REMOVED
BEFORE PROCEEDING WITH THE INSTALLATION.
Attach a Keyboard, Monitor and External USB CD-ROM Drive
Attach a keyboard, monitor and external USB CD-ROM drive to the Intel® Server System SSR212MC2 (See the Intel® Storage Server SSR212MC2 / SSR212MCR Quick Start User’s Guide folded sheet for more information). Power on the Intel® Server System SSR212MC2 and insert the StorTrends iTX Installation CD into the external USB CD-ROM drive.
Installation Procedure
Step Description
1
11
StorTrends® iTX Installation and Login Intel® Server System SSR212MC2
Step Description
Once the keyboard, monitor and external USB CD-ROM Drive have been attached, power on the Intel® Server System SSR212MC2.
2 Enter the Aptio® Setup Utility (AMIBIOS) to configure the system to boot from the
StorTrends iTX Installation CD. The Intel® Server System SSR212MC2 takes
approximately one and a half minutes to get to the screen that prompts to enter SETUP.
When prompted with, “Press <F2> to enter setup, <F12> Network boot,” press the <F2> key on the keyboard.
Version X.XX.XXX. Copyright (C) 2005-2XXX American Megatrends, Inc. Press <F2> to enter setup, <F12> Network Boot
Step Description
3 If performed successfully, the Aptio Setup Utility screen should display. If not, reset the
power on the Intel® Server System SSR212MC2 and start over.
Aptio Setup Utility - Copyright (C) 2005-2007 American Megatrends, Inc.
Main Advanced Security Server Management Boot Options Boot Manager
Logged in as Administrator Platform ID
System BIOS
Version Build Date
Processor Intel (R) Xeon (R) CPU
Core Frequency Count
Memory
Size
Quiet Boot
POST Error Pause
System Date System Time
Version X.XX.XXXX, Copyright (C) 2005-2007 American Megatrends, Inc.
XXXXXXXX
XXXXXXX.XXX.XX.XX.XXXX MM/DD/YEAR
XXXX @ X.XX GHz
X.XX GHz X
X GB
[Disabled]
[Disabled]
[Mon MM/DD/YEAR] [HH:MM:SS]
[Enabled] - Display the logo screen during POST.
[Disabled] - Display the diagnostic screen during POST.
Select Screen Select Item Change Value
+ / -
Select Field
Enter
General Help
F1
Optimized Defaults
F9
Save and Exit
F10
Exit
ESC
12
StorTrends® iTX Installation and Login
Intel® Server System SSR212MC2
Step Description
4 Using the <RIGHT ARROW> key, select Boot Manager. Using the <UP ARROW> and
<DOWN ARROW> keys, select the USB CD-ROM Drive. Press the <ENTER> key to
boot from the StorTrends iTX Installation CD.
Aptio Setup Utility - Copyright (C) 2005-2007 American Megatrends, Inc.
Main Advanced Security Server Management Boot Options Boot Manager
BRANDNAME CD-ROM USBDRIVE
#0400 ID02 LUN0 ATA NOTEBOOKHDD IBA GE Slot 0501 vXXXX [EFI Shell]
Version X.XX.XXXX, Copyright (C) 2005-2007 American Megatrends, Inc.
Select this option to boot now.
Note: This list is not the system boot option order. Use the Boot Options menu to view and configure the system boot option order.
Select Screen Select Item Change Value
+ / -
Select Field
Enter
General Help
F1
Optimized Defaults
F9
Save and Exit
F10
Exit
ESC
Note: Make sure that the proper menu is selected. A common error is to select the Boot Options menu instead of the Boot Manager menu.
Step Description
5 If performed successfully, the Welcome to AMI StorTrends iTX screen should display.
If not, reset the power on the Intel® Server System SSR212MC2 and start over.
Press the <ENTER> key to continue.
American Megatrends Inc
----------------------------------
Welcome to AMI Stortrends ITX.
To install on 3200i/1100i/Intel SSR212MC2, press the <ENTER> key. To install on Intel Helena Island(SS4200-E), type helena and press the <ENTER> key.
boot: _
Step Description
13
Loading...
+ 27 hidden pages