A reference guide to assist customers in ordering the necessary components to
configure the Intel® Server Board S5520UR and the appropriate 1U and 2U Intel Rack
Mount Server Systems
November 1.6
November 2009
Enterprise Platforms and Services Marketing
Page 2
Revision History
November`08 – Rev0.9 – Updated for production board and systems.
February`09 - Rev 1.0 – Ready for open books .
March`09 – Rev 1.01 – Updated with images of Spares and Accessories.
March`09 – Rev 1.02 – SR1600URNA MM# updated.
April’09 – Rev 1.03 – Pictures updated, MM# for ASR2600LXFANS corrected.
April’09 – Rev 1.1 – Management SW section added.
April’09 – Rev 1.2 – LCP SKU added
June’09 – Rev 1.3 – Riser and 10G module added. Pictures added
September’09 – Rev 1.4 – SR2600URSATA added. Pictures added
October’09 – Rev 1.5 – VMware vSphere* Virtualization Software added.
November’09 – Rev 1.6 – Update the MM# of AXXIBQDRIOMOD.
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCTS.
NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL
PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S
TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY
WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING T O
SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO
FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY
PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
Intel products are not intended for use in medical, life saving, life sustaining applications. Intel may make
changes to specifications and product descriptions at any time, without notice.
Intel server boards, server chassis, and processors may contain design defects or errors known as errata,
which may cause the product to deviate from published specifications. Current characterized errata are
available on request.
Intel, Intel Xeon, Pentium, and the Intel logo are trademarks or registered trademarks of Intel Corporation
or its subsidiaries in the United States and other countries.
1. SYSTEM PRODUCT ORDER CODES...........................................................................................................................4
2.4 SYSTEM SPARES AND ACCESSORIES........................................................................................................................13
2.5 POWER SUB-SYSTEM SPARES AND ACCESSORIES................................................................................................... 17
2.6 CONTROL PANEL SPARES AND ACCESSORIES..........................................................................................................18
2.7 RISER SPARES AND ACCESSORIES............................................................................................................................ 19
2.8 RAILS AND MOUNTING OPTIONS ................................................................................................................................ 20
2.9 CHASSIS AND ELECTRICAL SPARES KITS .................................................................................................................. 20
3. INTEL® SYSTEM MANAGEMENT SOFTWARE....................................................................................................... 23
4.2 VMWARE VSPHERE* AND VCENTER*SERVER SKUS............................................................................................... 25
3
Page 4
1. System Product Order Codes
1.1 Product Descriptions – Overview
Product based on the Intel® Server Board S5520UR will be offered in two methods at production:
1. Intel® Server Systems (Integrated SKUs). Customer orders an integrated system. All
systems – except SR1600URHS – are complete and ready to use with installation of CPUs
and memory. Except SR1600URHS – systems do not require additional components.
All systems do not include Processors, DDR3 main memory, hard drives, and other customer
configuration items
2. 10 Pack Server Board SS5520UR. Intended for customers utilizing 3
rd
party chassis or for
customers requiring spare boards.
* Chassis will not be offered separately.
1.2 Board and System Product Order Codes
Not included in systems: Processors, DDR3 main memory, hard drives, and othercustomer
configuration items are not included in below SKUs.
Product Code
MM
UPC
Image
Description
BB5520UR
901085
735858206587
Intel Server Board S5520UR (shipped in bulk pack of 10) 10
Minimum
Order
Quantity
SR1600UR
735858206723
900983
Intel Server System SR1600UR fixed configuration.
Includes:
• Intel Server Board S5520UR
• Intel Server Chassis SR1600
• Cabled front panel (no video port)
• 3 3.5" fixed HDD sleds, pre routed sata cables.
• 5 non-redundant non-hotswap dual-rotor fans
• 1 full height riser with PCI Express 2.0 x16 slot
• 1 fixed high-efficient 600W power supply
• Fan-board
• SATA and power cables to connect 3 HDDs
• 7 DIMM blanks
• 2 processor heatsinks
• 2 chassis front handles in the box (ears)
For complete list of accessories – please reference section 2.
4
1
Page 5
SR1600URNA
Same as SR1600UR but with North American power cord. 1
901125
NA
SR1600URHS
900985
735858206730
SR1600URHSNA
Intel Server System SR1600URHS Hot-Swap configuration.
Includes:
• Intel Server Board S5520UR
• Intel Server Chassis SR1600
• Standard control panel
• 3 3.5" HDD carriers
• NO backplane
• Bridge board
• 5 non-redundant non-hotswap dual-rotor fans
• 1 full height riser with PCI Express 2.0 x16 slot
• 1 fixed high-efficient 600W power supply
• 7 DIMM blanks
• 2 processor heatsinks
• 2 chassis front handles in the box (ears)
Does not include backplane.
*NOTE: System Backplane must be ordered separately to
complete system.
Required accessory (choose one of two options):
To obtain SAS/SATA HotSwap functionality
Backplane – ASR1500SASBP (offers onboard SAS controller
with SW RAID support).
To obtain SATA HotSwap functionality – order ASR1500PASBP, which allows cabled pass-through
connection from motherboard or add-in controller.
For complete list of accessories – please reference section 2.
Same as SR1600URHS but with North American power cord. 1
– order Active
1
901126
NA
1
735858206747
SR1625UR
900986
Intel Server System SR1625UR passive configuration.
Includes:
• Intel Server Board S5520UR
• Intel Server Chassis SR1625
• Mini control panel
• 6 of 2.5" HDD carriers (and filler in bays 7&8)
• 5 redundant non-hotswap fans
• 1 full height full length riser with PCI Express 2.0 x16
slot
•Passive (pass-through, no SAS controller) SATA
Midplane, cabled to SATA ports on motherboard .
SAS drives can be supported by adding discreet SAS
controller.
•Backplane with proprietary cable-less connection to
Midplane, supporting 8 hot-swap SAS/SATA drives.
Discrete SAS controller must be added to system to
support SAS drives.
• Bridge board
• 7 DIMM blanks
5
Page 6
• 2 processor heatsinks
• 1 hot-swap and redundant capable high-efficient 650W
power supply.
•2 chassis front handles in the box (ears)
Key Optional accessories:
To enable redundant power supply feature – order additional
power supply ASR1625PS
To add SW Raid5 support – order AXXRAKSW5 key
To add HW raid functionality: need to install add-in PCI HW
Raid controller, which must be cabled to Passive Midplane
Alternatively, Passive Midplane may be replaced with Active
(FALSASMP2)
To add support for 8 SAS/SATA drives by add-in controller –
order additional 2.5” HDD drive carriers (available in 10 pack
FXX25HDDCAR).
To add Standard Control Panel - order ASR1625FP
*Note: Only one control panel (Mini, Standard, or Local) can be
used in a system at a time
*Note: Standard CP, LCP and two additional drives are
installed in the same bay, and can not be installed at the same
time
For complete list of accessories – please reference section 2
SR1625URNA
Same as above but with North American power cord 1
901132
NA
SR1625URSAS
735858206754
900987
Intel Server System SR1625UR active configuration.
Includes:
• Intel Server Board S5520UR
• Intel Server Chassis SR1625
• Mini control panel
• 6 2.5" HDD carriers (and filler in slots 7&8)
• 5 redundant non-hotswap fans
• 1 full height full length riser with PCI Express 2.0 x16
slot,
•Active cable-less Midplane2 board with 8-port LSI
1078 SAS controller upgradeable to HW RAID mode
•Backplane with proprietary cable-less connection to
Midplane, supporting 8 hot-swap SAS/SATA drives.
• Bridge board
• 7 DIMM blanks
• 2 processor heatsinks
• 1 hot-swap and redundant capable high-efficient 650W
power supply
•2 chassis front handles in the box (ears)
Key Optional Accessories:
To enable redundant power supply feature – order additional
power supply (ASR1625PS)
To upgrade to full-reatured HW RAID on Active Midplane2:
order Raid key (AXXRAKSAS2) , minidimm
(AXXMINIDIMM512). RAID cache battery backup is optional
(AXXRSBBU3).
To add support for 8 drives by SAS controller on Active
1
6
Page 7
Midplane2– order two additional 2.5” HDD drive carriers
(FXX25HDDCAR).
To add Standard Control Panel - order ASR1625FP.
*Note: Only one control panel (Mini or Standard) can be used in
a system at a time.
*Note: Standard CP, LCP and the two right most drives (7&8)
are installed in the same bay, and can not be installed at the
same time.
For complete list of accessories – please reference section 2.
SR1625URSASNA
Same as above but with North American power cord
901136
NA
SR2600URBRP
735858206761
901093
Intel Server System SR2600UR system in base-passive
configuration. Includes:
• Intel Server Board S5520UR
• Intel Server Chassis SR2600
• Standard control panel
• 5 3.5" HDD carriers
• 3 fixed, non redundant fans
• Tape drive bay filler
• 1 riser with three full-height PCI Express 2.0 x8 wired
slots (one x16 and two x8 connectors),
•Passive (pass-through, no SAS controller) SATA
Midplane, cabled to SATA ports on motherboard .
SAS drives can be supported by adding discreet SAS
controller.
•Backplane with proprietary cable-less connection to
Midplane, supporting up to 6 hot-swap SAS/SATA
drives. Discrete SAS controller must be added to
system to support SAS drives.
• Bridge board
• 7 DIMM blanks
• 2 processor heatsinks
• 1 hot-swap and redundant capable high-efficient 750W
power supply
•2 chassis front handles in the box (ears)
Note(1): To enable SAS drives - add-in SAS adapter is
required. SATA drives can be used in out of the box system.
Key Optional accessories:
To enable power supply redundancy – order AXX750WPS
To upgrade cooling system to redundant– order
ASR2600LXFANS.
To add support for 6
ASR2500SIXDRV
To change PCI expansion slots – included riser must be
replaced with ASR26XXFHLPR or ASR26XXFHXR
To add support for SATA Tape Drive – order ASR2500SATAPE
*NOTE: ASR2500SIXDRV and ASR2500SATAPE are installed
in the same bay and can not be installed at the same time.
For complete list of accessories – please reference section 2.
th
hot-swap 3.5 inch drive – order
1
7
Page 8
SR2600URBRPNA
Same as above but with North American power cord 1
901187
NA
SR2600URLX
900988
735858206778
SR2600URLXNA
Intel Server System SR2600UR in active-SAS configuration.
Includes:
• Intel Server Board S5520UR
• Intel Server Chassis SR2600
• Standard control panel
• 5 3.5" HDD carriers
• 6 redundant and hot-swap fans
• Tape drive bay filler
• 1 active butterfly riser with 5 PCI Express 2.0 x8 wired
•Passive (pass-through, no SAS controller) SATA
Midplane, cabled to SATA ports on motherboard .
SAS drives can be supported by adding discreet SAS
controller.
•Backplane with proprietary cable-less connection to
Midplane, supporting up to 6 hot-swap SAS/SATA
drives.
• Bridge board
• 7 DIMM blanks
• 2 processor heatsinks
• 2 hot-swap and redundant capable high-efficient 750W
power supply
•2 chassis front handles in the box (ears)
Key Optional Accessories:
To enable power supply redundancy – order AXX750WPS
To add PCI-X support – included riser must be replaced with
ASR26XXFHXR
To add support for 6th hot-swap 3.5 inch drive – order
ASR2500SIXDRV
To add support for SATA Tape Drive – order ASR2500SATAPE
*NOTE: ASR2500SIXDRV and ASR2500SATAPE are installed
in the same bay and can not be installed at the same time.
For complete list of accessories – please reference section 2.
SR2600URSATANA
Same as above but with North American power cord 1
903802
NA
SR2625URBRP
735858206785
900989
Intel Server System SR2625UR in base-passive
configuration. Includes:
• Intel Server Board S5520UR
• Intel Server Chassis SR2625
• Standard control panel
• 6 2.5" HDD carriers (and filler in slots 7&8)
• 3 fixed, non redundant fans
• Tape drive bay filler
• 1 full-height riser with three PCI Express 2.0 x8 wired
slots (one x16 connector and two x8 connectors)
•Passive (pass-through, no SAS controller) SATA
Midplane, cabled to SATA ports on motherboard .
SAS drives can be supported by adding discreet SAS
controller.
•Backplane with proprietary cable-less connection to
Midplane, supporting 8 hot-swap SAS/SATA drives.
Discrete SAS controller must be added to system to
support SAS drives.
• Bridge board
• 7 DIMM blanks
• 2 processor heatsinks
• 1 hot-swap and redundant capable high-efficient 750W
power supply
•2 chassis front handles in the box (ears)
Note(1): To enable SAS drives - add-in SAS adapter is
1
9
Page 10
required. SATA drives can be used in out of the box system.
Key Optional Accessories:
To enable power supply redundancy – order AXX750WPS
To add or change PCI expansion slots – included riser must be
replaced with ASR26XXFHLPR or ASR26XXFHXR
To add support for SATA Tape Drive – order ASR2500SATAPE
For complete list of accessories – please reference section 2.
SR2625URBRPNA
Same as above but with North American power cord 1
901141
NA
SR2625URLX
900990
735858206792
SR2625URLXNA
Intel Server System SR2625UR system in SAS
configuration. Includes:
• Intel Server Board S5520UR
• Intel Server Chassis SR2625
• Standard control panel
• 8 2.5" HDD carriers
• 6 redundant and hot-swap fans
• Tape drive bay filler
• 1 active butterfly riser with five PCI Express 2.0 x8
•Active cable-less Midplane2 board with 8-port LSI
1078 SAS controller, upgradeable to HW RAID mode
• Bridge board
• Backplane with proprietary cable-less connection to
Midplane, supporting 8 hot-swap SAS/SATA drives.
• 7 DIMM blanks
• 2 processor heatsinks
• 1 hot-swap and redundant capable high-efficient 750W
power supply
•2 chassis front handles in the box (ears)
Key Optional Accessories:
To enable power supply redundancy – order AXX750WPS
To upgrade to full-reatured HW RAID on Active Midplane2:
order Raid key (AXXRAKSAS2) , minidimm
(AXXMINIDIMM512). RAID cache battery backup is optional
(AXXRSBBU3).
To add PCI-X support – included riser must be replaced with
ASR26XXFHXR
To add support for SATA Tape Drive – order ASR2500SATAPE
For complete list of accessories – please reference section 2.
Same as above but with North American power cord 1
1
901129
NA
10
Page 11
2. Spares and Accessories Order Codes
2.1 I/O Modules
Product Code
Image
MM
Description
UPC
AXX10GBIOMOD
900962
735858206525
AXX4GBIOMOD2
901359
735858206532
AXXIBQDRIOMOD
902559
735858212601
10GbE I/O module Dual port CX4 connector,
based on Intel 82598 EB controller.
Compatible with S5520UR and S5500WB boards
only.
Quad port GbE I/O module, based on Intel 825 7 6
controller. RJ-45 connectors. Compatible with
S5520UR and S5500WB boards only.
Single port QDR speed InfiniBand I/O Module.
CX4 powered connector. MT25408A0-FCC-QIS
Controller.
Compatible with S5520UR boards only.
Minimum
Order
Quantity
1
1
1
Internal 4-port SAS module, based on LSI* 1064e
AXX4SASMOD
900946
735858206372
AXXROMBSASMR
901641
735858208017
controller, with Embedded RAID support.
(primarily targeted at non-Iintel chassis)
Compatible with S5520UR, S5500WB, S5520HC,
S5520SC boards only. Not compatible with Intel
rack server chassis.
Internal 4-port SAS module, based on LSI* 1078e
controller. Provides 4 port full featured
SAS/SATA RAID 0,1,5, 6 and striping capability
for spans 10, 50, 60. (primarily targeted at nonIntel chassis)
Compatible with S5520UR, S5500WB, S5520HC,
S5520SC boards only. Not compatible with Intel
rack server chassis.
1
1
11
Page 12
AXXSASIOMOD
902300
00735858184786
External 4-port SAS expansion module.
Compatible with Intel Server Boards S5520UR,
S5000PALR and S5400SF.
AXXIBIOMOD
881891
735858185219
AXXGBIOMOD
880518
735858184779
InfiniBand I/O Expansion Module, SDR speed.
Compatible with Intel Server Boards S5520UR,
S5000PALR and S5400SF.
Dual Port Gigabit Ethernet I/O Expansion
Module. Based on Intel 82571EB GbE controller.
Compatible with Intel Server Boards S5520UR,
S5500WB, S5000PALR and S5400SF.
2.2 SR2600 and/or SR2625 Flex Bay Kits
Product Code
Image
MM
UPC
Description
1
1
Minimum
Order
Quantity
ASR2500SATAPE
881260
735858184069
ASR26XXFXDRV
903534
735858210287
SATA Tape Drive Mounting Kit, includes short
& long SATA cables, power cable, screws, tray.
(also compatible with SR2500 system)
Kit is installed in tape drive bay sled and holds
two cabled 2.5” drives. SSD and SATA drives
will be validated. No SAS drives will be
validated as they need special cabling.
12
SR2625/SR2600
SR2600/2625 Fixed drive kit
1
1
Page 13
2.3 Bezels
Image
* ADRBEZBLACK shown.
ASR2500SIXDRV
735858184076
Product Code
ADWBEZBLACK
00735858169110
ADRBEZBLACK
00735858165129
ASR1550MINBEZ
00735858183895
ADWLCDBEZEL
00735858164993
ADRLCDBEZEL
00735858165082
ASR1550LCDBEZ
00735858183901
ASR1550BEZ
00735858183888
902045
MM
UPC
865064
857675
879211
882435
857586
879209
879406
SR2600 only
6th SAS/SATA HDD Kit (also compatible with
SR2500 system, updated with filler panel not
shown in picture)
Description
SR1600/1500/1400 Black Bezel for standard
control panel.
SR2600/2625/2500 Black Bezel for standard
control panel.
SR1625/1550 Black Bezel for use with Mini
Control Panel.
SR1600/1400/1500 Black Bezel with cutout for
Intel Local Control Panel (LCD).
Note: requires Intel Local Control Panel.
SR2600/2625/2500/2400 Black Bezel with cutout
for Intel Local Control Panel (LCD).
Note: requires Intel Local Control Panel.
SR1625/1550 Black Bezel for use with Local
Control Panel.
Note: requires Intel Local Control Panel.
SR1625/1550 Black Bezel for use with Standard
control panel.
Note: requires Standard Control Panel.
1
Minimum
Order
Quantity
1
1
1
1
1
1
1
2.4 System Spares and Accessories
Product Code
Image
MM
UPC
AXXRMM3
900961
735858206570
13
Description
Remote management module 3 kit
(includes module, standard and Intel
chassis specific mounting brackets, long
and short cables)
Minimum
Order
Quantity
1
Page 14
Intel® RAID Activation Key for
AXXRAKSAS2
891290
735858194730
Note: enabling RAID capability also
requires mini DIMM (AXXMINIDIMM512)
FALSASMP2
5
(Reused from SR1500/SR2500 system)
AXXRAKSW5
878958
00735858181860
Intel® RAID Activation Key
AXXRAKSW5 enables SATA Host-
based RAID 5
5
AXXMINIDIMM512
897046
735858202015
512 MB Mini DIMM registered DDR-2
for use with FALSASMP2
5
AXXRSBBU3
900954
735858181853
Intel® RAID Smart Battery Backup
module for use with
Intel® Integrated Server RAID
5
AXXRJ45DB92
903041
735858155212
RJ45 To DB9 Cable (Also compatible
with SR1500/2500 system) (Old MM#
881944)
1
AXXSATADVDROM
893637
Slimline SATA DVDROM Device 1
735858197663
14
Page 15
AXXSATADVDRWROM
898051
(pending update to
Slim SATA DVD+/-RW ROM Accessory 1
898292)
735858197670
AXXUSBFLOPPY
881267
735858183260
SR1600/2600 USB Floppy Device
Accessory (not compatible with
SR1625/2625))
1
FPWRCABLENA
879287
North American Power Cord Spare 1
735858181129
SR1600/SR1500 (1U) Hotswap Passive
SAS/SATA Backplane Kit . Compatible
with either SAS or SATA 3.5” hard
ASR1500PASBP
735858183758
902485
drives. Kit contents include the following:
Hot swap backplane with pass-through
capabilities for either onboard SATA
ports or a SAS/SATA add-in card,
Enclosure management cable, 3
SAS/SATA cables (pre-kitted and length
1
matched to the SATA ports on the server
board)
SR1600/SR1500 (1U) Hotswap SAS
Backplane Kit. Compatible with either
SAS or SATA 3.5” hard drives. Kit
ASR1500SASBP
735858183741
903510
Backplane with SAS controller, USB
cable (to front panel).
includes:
1
15
Page 16
SR2600/2625UR
FSR2600LXFAN
901087
735858206679
LX hot swap redundant fan spare kit.
Contains 3 fans (1 x 60mm, 2 x 80mm).
Notes: Not compatible with BRP SKU
1
fans.
ASR2600LXFANS
901078
735858206464
SR2600BRP/SR2625BRP Redundant
fan upgrade kit. Contains 6 fans, fan
structure, cable set.
1
FXX1UFAN
881101
735858184243
SR1600/SR1625/SR1500/SR1550 Fan
spare kit. Contains one 56mm fan with
short cable, and one 56mm fan with long
cable.
1
FURBRIDGE
901088
Bridge Board Spare 30
735858206709
SR1625/2600/2625UR SAS Midplane-2
with optional Intel® Integrated Server
FALSASMP2
892611
735858198110
8 port SAS controller with optional HW
RAID upgrade. Note RAID requires new
RAID activation key (MM# 891290) and
RAID (support RAID 6).
1
new RAID mini DIMM (cache) each sold
separately (MM# 897046).
SR1625/2600/2625UR Passive
Midplane
Compatible with either SAS or SATA
FALPASMP
901687
00735858183826
hard drives. Kit contents include the
following:
Passive mid-plane with pass-through
capabilities for either onboard SATA
ports or a SAS/SATA add-in card,
1
Enclosure management cable, Note:
SATA drive cables are not included.
16
Page 17
FXX10DVCARBLK
880265
735858181938
3.5" Hot Swap HDD Carrier Spare
(compatible with prior generations)
10
FXX25HDDCAR
881681
735858183932
SR1625/2625UR 2.5" HDD carrier spare
kit
10
2.5'' Hard Disk Drive Carrier Kit, include
ten 2.5” drive carriers and installation
guide.
AXX25DRVADPTR
904083
00735858211567
The 2.5” HDD carrier is for installing 2.5”
SAS, SATA, or SSD into 3.5” hot-swap
hard disk drive bay.
See compatible Intel® chassis and
systems at: