Intel SR2625UR - Server System - 0 MB RAM, SR2600UR, SR2600URLX, SR2625URLX, SR2600URBRP, SR2625URBRP Service Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
Intel® Server System SR2600UR/
SR2625UR Service Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/
Products
Intel Order Number E51243-007
Disclaimer
®
Information in this document is provided in connection with Intel
products. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's
Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any
express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to
fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property
right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining
applications or for any other application in which the failure of the Intel product could create a situation where
personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time,
without notice.
Intel server boards contain a number of high-density VLSI and power delivery components that need adequate
airflow for cooling. Intel's own chassis are designed and tested to meet the intended thermal requirements of these
components when the fully integrated system is used together. It is the responsibility of the system integrator that
chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to
determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation
can not be held responsible if components fail or the server board does not operate correctly when used outside any
of their published operating or non-operating limits.
Intel, Intel Pentium, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in
the United States and other countries.
iiIntel® Server System SR2600UR/SR2625UR Service Guide
Preface
About this Manual
Thank you for purchasing and using the Intel® Server System SR2600UR/SR2625UR.
This manual is written for system technicians who are responsible for troubleshooting,
upgrading, and repairing this server system. This document provides reference
information, feature information, and step-by-step instructions for adding and replacing
components in the server system. For the latest version of this manual, see
Chapter 1 provides information on the contents of each server system and a list of
reference resources. This includes a list of all technical documents that provide additional
details on the Intel
can be found.
®
Server System SR2600UR/SR2625UR, and the location where they
.
Chapter 2 provides a brief overview of the server system. This includes a list of the server
system features, illustrations of the product, and product diagrams to help you identify
components and their locations.
Chapter 3 provides instructions for adding and replacing components. It provides step-bystep instructions and diagrams for installing or replacing components such as the fans,
power supply, drives, and other components.
Chapter 4 provides instructions on using the utilities that are shipped with the board or
that may be required to update the system. This includes information for navigating
through the BIOS Setup screens, performing a BIOS update, and resetting the password or
BIOS defaults.
The back of this manual provides technical specifications, regulatory information,
“Getting Help” information, and the warranty.
Intel® Server System SR2600UR/SR2625UR Service Guideiii
ivIntel® Server System SR2600UR/SR2625UR Service Guide
Safety Information
Before you begin the assembly process, you will need to make sure you follow certain
basic safety precautions.
Important Safety Instructions
Read all caution and safety statements in this document before performing any of the
instructions. See also Intel Server Boards and Server Chassis Safety Information on the
Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor
Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu
Intel-Serverplatinen und Servergehäusen auf der Intel
oder unter
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce
document avant de suivre toute instruction. Consultez Intel Server Boards and Server
Chassis Safety Information sur le Intel
rendez-vous sur le site
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar
cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety
Information en el Intel
Intel® Server System SR2600UR/SR2625UR Service Guidev
®
Server Deployment Toolkit 3.0 CD y/o en
.
Warnings
重要安全指导
Heed safety instructions: Before working with your server product, whether you are
using this guide or any other resource as a reference, pay close attention to the safety
instructions. You must adhere to the assembly instructions in this guide to ensure and
maintain compliance with existing product certifications and approvals. Use only the
described, regulated components specified in this guide. Use of other products/
components will void the UL listing and other regulatory approvals of the product and
will most likely result in noncompliance with product regulations in the region(s) in which
the product is sold.
System power on/off: The power button DOES NOT turn off the system AC power. To
remove power from the system, you must unplug the AC power cord from the wall outlet.
Make sure the AC power cord is unplugged before you open the chassis, and add or
remove any components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be
present on power, telephone, and communication cables. Turn off the server and
disconnect the power cord, telecommunications systems, networks, and modems attached
to the server before opening it. Otherwise, personal injury or equipment damage can
result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives,
boards, and other parts. We recommend that you perform all the procedures in this chapter
only at an ESD workstation. If one is not available, provide some ESD protection by
wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on
your server when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely
sensitive to ESD. Hold boards only by their edges. After removing a board from its
protective wrapper or from the server, place the board component side up on a grounded,
static free surface. Use a conductive foam pad if available but not the board wrapper. Do
not slide board over any surface.
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips
over two jumper pins. Some jumpers have a small tab on top that you can grip with your
fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab,
viIntel® Server System SR2600UR/SR2625UR Service Guide
take care when using needle nosed pliers to remove or install a jumper; grip the narrow
sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can
damage the contacts inside the jumper, causing intermittent problems with the function
controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool
you use to remove a jumper, or you may bend or break the pins on the board.
Intel® Server System SR2600UR/SR2625UR Service Guidevii
viiiIntel® Server System SR2600UR/SR2625UR Service Guide
Figure 96. Removing the Bridge Board from the Server System .......................................... 104
Figure 97. Removing the Midplane from the Server System................................................. 105
Figure 98. Installing the Midplane into the Server System.................................................... 106
Figure 99. Installing the SATA Cables .................................................................................. 107
Figure 100. Installing the Bridge Board into the Server System............................................ 108
®
Figure 101. Removing the Backplane from the Intel
Figure 102. Removing the Backplane from the Intel
Figure 103. Installing the Backplane into the Intel
Figure 104. Installing the Backplane in the Intel
Server System SR2600UR ............... 109
®
Server System SR2625UR ............... 110
®
Server System SR2600UR................... 111
®
Server System SR2625UR...................... 112
Figure 105. Installing the RAID Activation Key and the RAID Mini-DIMM............................. 113
Figure 106. Removing the RAID Activation Key and the RAID Mini DIMM........................... 114
Figure 107. Installing the RAID Battery Backup Unit............................................................. 116
Figure 108. Removing the RAID Battery Backup Unit........................................................... 117
Figure 109. Removing the Server Board............................................................................... 118
Figure 110. Installing the Server Board................................................................................. 119
Figure 111. Replacing the Backup Battery............................................................................ 121
Figure 112. Removing Power Supply Filler Panel from the Server System.......................... 122
Figure 113. Removing Power Supply Module from the Server System ................................ 122
Figure 114. Installing Power Supply Module into the Server System.................................... 122
Figure 115. Installing Power Supply Filler Panel into the Server System ............................. 123
Figure 116. Removing the Power Distribution Module.......................................................... 124
Figure 117. Removing Standard Control Panel Module from the Server System................. 125
Figure 118. Installing Control Panel Module into the Server System.................................... 126
Figure 119. Removing Standard Control Panel Module from the Server System................. 127
Figure 120. Connecting the Control Panel Cables................................................................ 127
Figure 121. Installing Control Panel Module into the Server System.................................... 128
Figure 122. Removing the Redundant Fan Module .............................................................. 129
Figure 123. Installing the Redundant Fan Module ................................................................ 130
Figure 124. Removing the Fixed Fan Module ....................................................................... 132
Figure 125. Installing the Fixed Fan Module ......................................................................... 133
Figure 126. Removing a Fan from the Redundant Fan Module............................................ 134
Figure 127. Installing a Fan into the Redundant Fan Module ............................................... 135
Figure 128. Removing a Fan from the Fixed Fan Module..................................................... 136
Figure 129. Installing a Fan into the Fixed Fan Module ........................................................ 137
Figure 130. Installing the Rack Handle ................................................................................. 138
Figure 131. Removing the Rack Handle ............................................................................... 138
Server System SR2600UR/SR2625UR Feature Summary ...............................9
Intel® Server System SR2600UR/SR2625UR Service Guidexix
xxIntel® Server System SR2600UR/SR2625UR Service Guide
1Server System Contents and
References
The following two versions of the Intel® Server System SR2600UR are available:
•
Intel® Server System SR2600URLX (active version)
•
Intel® Server System SR2600URBRP (passive version)
®
Unless noted otherwise, all references to the Intel
both versions.
Server System SR2600UR refer to
The following two versions of the Intel
•
Intel® Server System SR2625URLX (active version)
•
Intel® Server System SR2625URBRP (passive version)
Unless noted otherwise, all references to the Intel
both versions.
®
Server System SR2625UR are available:
®
Server System SR2625UR refer to
Server System Contents
The Intel® Server System SR2600UR/SR2625UR ships with the Intel® Server Board
S5520UR. For information about the server board, see the IntelTechnical Product Specification.
®
The contents of the Intel
Server System SR2600UR/SR2625UR are listed below.
Intel® Server System SR2600URLX/SR2625URLX (Active System)
Contents
Your Intel® Server System SR2600URLX/SR2625URLX ships with the following items:
®
Server Board S5520UR
•
Intel® Server Board S5520UR, installed in the server system
•
One 750-W power supply, installed in the server system
•
2U PCI Express* active riser card assembly (with three full-height and two lowprofile PCI Express* connectors), installed in the server system
•
Chassis intrusion switch, integrated into the server system riser
•
Standard control panel, installed in the server system
•
Active SAS/SATA midplane, installed in the server system
•
Hot-swap SAS/SATA backplane, installed in the server system
Intel® Server System SR2600UR/SR2625UR Service Guide1
•
Redundant fan module, installed in the server system
•
Bridge board, installed in the server system
•
Processor air duct, installed in the server system
•
Two processor heatsinks, installed in the server system
•
Five 3.5-inch hot-swap drive trays and drive filler blanks, installed in the server
system (SR2600URLX only)
•
Eight 2.5-inch hot-swap drive trays and drive filler blanks, installed in the server
system (SR2625URLX only)
•
Flex bay drive tray, installed in the server system
•
Three air baffles (including a large air baffle, fan baffle, and small air baffle),
installed in the server system (SR2600URLX only)
•
Two air baffles (including a large air baffle and a fan baffle), installed in the server
system (SR2625URLX only)
•
A box of hardware components (referred to herein as the “hardware box”)
•
Slimline peripheral bay filler panel, in the hardware box
•
Optical drive tray assembly, in the hardware box
•
One 32-6mm flat screw for installing the optical drive component, in the hardware
box (SR2600URLX only)
•
Two screws for installing the optical drive component, in the hardware box
(SR2625URLX only)
•
Rack handles, in the hardware box
•
Attention document, in the server system product box
•
Quick Start User's Guide, in the server system product box
•
Intel® Server Deployment Toolkit 3.0 CD
•
Intel® System Management Software DVD
Intel® Server System SR2600URBRP/SR2625URBRP (Passive
System) Contents
Your I nt el® Server System SR2600URBRP/SR2625URBRP ships with the following
items:
•
Intel® Server Board S5520UR, installed in the server system
•
One 750-W power supply, installed in the server system
•
2U PCI Express* passive riser card assembly (with three full-height PCI Express*
connectors), installed in the server system
•
Chassis intrusion switch, integrated into the server system riser
•
Standard control panel, installed in the server system
•
Passive midplane, installed in the server system
2Intel® Server System SR2600UR/SR2625UR Service Guide
•
Hot-swap SAS/SATA backplane, installed in the server system
•
Non-redundant fan module, installed in the server system
•
Bridge board, installed in the server system
•
Processor air duct, installed in the server system
•
Two processor heatsinks, installed in the server system
•
Five 3.5-inch hot-swap drive trays and drive filler blanks, installed in the server
system (SR2600URBRP only)
•
Six 2.5-inch hot-swap drive trays and drive filler blanks, installed in the server
system (SR2625URBRP only)
•
A filler panel (for drive locations 6 and 7), installed in the server system
(SR2625URBRP only)
•
Flex bay drive tray, installed in the server system
•
Two air baffles (including a large air baffle and small air baffle), installed in the
server system (SR2600URBRP only)
•
A large air baffle, installed in the server system (SR2625URBRP only)
•
A box of hardware components (referred to herein as the “hardware box”)
•
Slimline peripheral bay filler panel, in the hardware box
•
Optical drive tray assembly, in the hardware box
•
One 32-6mm flat screw for installing the optical drive component, in the hardware
box (SR2600URBRP only)
•
Two screws for installing the optical drive component, in the hardware box
(SR2625URBRP only)
•
Rack handles, in the hardware box
•
Attention document, in the server system product box
•
Quick Start User's Guide, in the server system product box
•
Intel® Server Deployment Toolkit 3.0 CD
•
Intel® System Management Software DVD
Intel® Server System SR2600UR/SR2625UR Service Guide3
Additional Information and Software
If you need more information about these products or information about the accessories
that can be used with these server systems, use the following resources.
Table 1. Server System References
For this information or
software
For in-depth technical
information about the
server system, including
subsystem overviews and
mechanical drawings
For in-depth technical
information about the
server board, including
board layout, connector
pin-outs, timing
information, mechanical
drawings and LED
information
For basic BIOS settings
and chipset information
If you just received this
product and you need to
assemble your system
and install components
Use this Document or Software
Intel® Server System SR2600UR Technical Product Specification
Intel® Server System SR2625UR Technical Product Specification
Available at:
Intel® Server System SR2600UR Quick Start User’s Guide
Provided in the product box
Intel® Server System SR2625UR Quick Start User’s Guide
Provided in the product box
Accessories or other Intel
server products
4Intel® Server System SR2600UR/SR2625UR Service Guide
Spares, Parts List and Configuration Guide
Available at:
Intel® Server System SR2600UR/SR2625UR Service Guide5
6Intel® Server System SR2600UR/SR2625UR Service Guide
2Server System Features
This chapter briefly describes the main features of the Intel® Server System SR2600UR/
SR2625UR. This includes illustrations of the products, a list of the server system features,
and diagrams showing the location of important components and connections on the
server systems.
Figure 1. Intel
®
Server System SR2600UR
AF002818
Intel® Server System SR2600UR/SR2625UR Service Guide7
Figure 2. Intel® Server System SR2625UR
AF002819
8Intel® Server System SR2600UR/SR2625UR Service Guide
Server System Feature Overview
Table 2 summarizes the features of the server systems.
®
Table 2. Intel
FeatureDescription
Server System SR2600UR/SR2625UR Feature Summary
Dimensions
Server BoardIntel
Processor Support for one or two Intel
Memory
Chipset
•
3.44 inches (87.30 mm) high
•
16.93 inches (430 mm) wide
•
27.75 inches (704.8 mm) deep
•
65 pounds (29.5 kg) - maximum chassis weight
®
Server Board S5520UR
Socket B package with up to 95 W Thermal Design Power (TDP)