Intel SC5650BRP - Server Chassis - Tower, SC5650DP, SC5650WS, SC5650UP Quick Start User Manual

Intel® Server Chassis
7
6
3
3
5
Da ta
Po we r
5a
1
2
5b
SC5650BRP/SC5650DP/ SC5650WS/SC5650UP Quick Start User's Guide
Thank you for buying the Intel® Server Chassis SC5650. The following information will help you to prepare your chassis for integration with your selected Intel® Server Board.
Building Value With Intel
Server Products, Programs and Support
Get the high-value server solutions you need by taking advantage of the outstanding value Intel provides to system integrators:
High-quality server building blocks
Extensive breadth of server building blocks
Solutions and tools to enable e-Business
Intel® System Management Software
Comprehensive training services
Worldwide 24x7 technical support
[AT&T Country Code + 866-655-6565]
World-class service, including a three-year
limited warranty and Advanced Warranty Replacement
1
1
Intel® ServerBuilder is your one-stop shop for information about all of Intel's server building blocks, such as:
Product information, including product
briefs and technical product specifications
Sales tools, such as videos and
presentations
Training information, such as the Intel
Online Learning Center
Support Information and much more
1
Available only to Intel® Channel Program
Members, part of the Intel® e-Business Network.
Remove Side Cover
Remove two screws.
1
Push in latch.
2
Slide side cover
3
rearward and remove.
®
1
2
3
1
These guides and other supporting documents (including a list of supported server boards) are located on the web at http://support.intel.com/support/motherboards/server/chassis/SC5650/
If you are not familiar with ESD (Electrostatic Discharge) procedures used during system integration, please see the Intel® Server Chassis SC5650 Service Guide, available on the CD that came with your Intel® Server Board.
Read all cautions and warnings before starting your server chassis integration.
Intel® Server Board Guide
The server board that can be installed in your Intel® Server Chassis SC5650 is dependent upon the configuration of the chassis purchased.
Chassis Configuration
Product Code
SC5650DP
SC5650WS
SC5650BRP
SC5650UP S3420GP Family
SC5650DP and SC5650BRP do not need a system air duct with S5500BC board. Only SC5650WS can support 130 W TDP CPU.
Compatible
Intel® Server Board
S5500BC, S5520HC,
S5500HCV
S5520SC
S5500BC, S5520HC,
S5500HCV
Remove Front Bezel Assembly
3
1
3
3
1
2
Lift outward two bezel tabs on
1
left side of bezel assembly to detach bezel assembly from the chassis.
Rotate left side of front bezel
2
assembly outward slightly.
Disengage three bezel clips
3
that attach the right side of the bezel to the right side of the chassis and remove.
Warning
Read all caution and safety
statements in this document before performing any of the instructions. Also see the Intel®
Server Board and Server Chassis Safety Information document at:
http://support.intel.com/support/ motherboards/server/sb/cs-010770 .htm for complete safety information.
Warning
Installation and service of this product to be performed only by qualified service personnel to avoid risk of injury from electrical shock or energy hazard.
Caution
Observe normal ESD [Electrostatic Discharge] procedures during system integration to avoid possible damage to server board and/or other components.
Tools Required
Hex nut driver (0.25 in or 6 mm)
#2 Phillips* screwdriver
Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation. All rights reserved.
E39540-004
Anti-static wrist strap
Remove Tool-less Hard Drive Cage
Loosen thumb screw. Apply pressure
1
to right side of EMI shield to release EMI shield from hard drive cage.
Remove Fan Duct/System Fan Assembly (for UP)
Snap-in Bracket
For SC5650UP only,
1
remove fan duct assembly and system fan by pushing the left and right tabs outward and disengaging from snap-in bracket.
Push blue plastic
2
release mechanism upward to unlatch hard drive cage.
2
1
Once released, pull hard drive
3
cage out of chassis.
1 2
2
3
Remove PCI Card Guide (only for S5500BC)
Press in on two blue tabs.
Pull PCI card guide outward and remove from chassis.
2
4
Install Tool-less CD-ROM or DVD-ROM Drive
Remove Fan Duct/ System Fan Assembly
Remove EMI shield from 5.25-inch device drive bay.
1
Make sure latch is in "unlock" position.
2
Insert CD-ROM or DVD-ROM
3
drive into device drive bay.
2
1
Install Server Board
See your Intel® server board Quick Start User's Guide for server board installation instructions and installation of the back panel I/O shield.
Use the mounting screws, bumpers and standoffs (if necessary) that came with your chassis to secure the server board to the chassis.
The standoffs that ship with the chassis need to be adjusted to accommodate the Intel® Server Board assembled. For the Intel®
Server Board S5500BC, standoffs should be installed at the following positions: K, L, M, F, 3, H, A and C. For the Intel® Server Board S5520HC/S5500HCV/S5520SC, standoffs should be installed at the following positions: K, L1, F, 3, E, J1, A, C and D, while there is a push pin already installed at position N.
For the Intel® Server Board S3420GP family, standoffs should be installed at the following positions: 1,3,A,C,F,H,K,L and M.
1
For other configurations, see the Quick Start User's Guide that came with your Intel® Server Board.
Return to this document when finished.
Line up holes in CD-ROM
4
or DVD-ROM drive with holes in chassis.
Move latch to "lock" position.
5
Connect power (P5 or P6 for
6
DP/BRP/WS; P3 or P4 for UP) cables and data cables to rear of the CD-ROM or DVD-ROM drive.
An additional 4-pin IDE male-to-SATA 15 pin power cable adapter may be needed if the CD-ROM or DVD-ROM does not have a 4-pin power connector.
Data cables are included with the Intel® Server Board.
6
Chassis Fan Connection for the Intel® Server Boards S5520HC / S5500HCV and Intel® Workstation Board S5520SC
= System Fan
header used
S5520HC/S5500HCV
S5520SC
System Fan 1 PCI Zone Chassis Fan
System Fan 2
System Fan 3
System Fan 4
System Fan 5
= Fan header used
System Fan 1 PCI Zone Chassis Fan
System Fan 2 HDD Cage Fan
System Fan 3 Rear Chassis Fan
Intel® Server
Chassis SC5650DP
Chassis Fan Connection for the Intel® Server Board S5500BC
Intel® Server
Chassis SC5650DP
Intel® Server
Chassis SC5650BRP
Intel® Server
Chassis SC5650BRP
4
Intel® Server
Chassis SC5650WS
Notes:
HDD Cage Fan
Rear Chassis Fan
For SC5650 DP/BRP/WS only:
1
Remove fan duct assembly as shown.
Remove system fan by
2
pushing the right and left tabs outward and disengaging from fan housing.
1
Right
Left
Tab
Tab
2
Notes:
Chassis Fan Connection for the Intel® Server Board S3420GP Family
= Fan header used
System Fan 1
System Fan 2 HDD Cage Fan
System Fan 3
System Fan 4 Rear Chassis Fan
Intel® Server
Chassis SC5650UP
Notes: