Intel R1000GZ, R1000GL Technical Product Specification

Intel® Server System
R1000GZ/GL Product Family
Technical Product Specification
Intel order number G24882-005
April 2012
Enterprise Platforms and Services Division
Intel® Server System R1000GZ/GL Product Family TPS
Date
Revision Number
Modifications
January 2012
1.0
1st Production Release
Updated Features Table
Revision History
Updated Environmental Limits Table
o Added ASHRAE support details
April 2012 1.1
Updated thermal management sections
Updated sections for embedded SCU and RAID support
Added sections for product errata definition and FRUSDR usage
Updated add-in card length limits to riser card sections.
Updated reference documents list
Disclaimers
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
UNLESS OTHERWISE AGREED IN WRITING BY INTEL, THE INTEL PRODUCTS ARE NOT DESIGNED NOR INTENDED FOR ANY APPLICATION IN WHICH THE FAILURE OF THE INTEL PRODUCT COULD CREATE A SITUATION WHERE PERSONAL INJURY OR DEATH MAY OCCUR.
Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined". Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The information here is subject to change without notice. Do not finalize a design with this information.
The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request.
Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order.
Copies of documents which have an order number and are referenced in this document, or other Intel literature, may be obtained by calling 1-800-548-4725, or go to:
http://www.intel.com/design/literature.htm
®
Intel
Xeon® is a registered trademark of Intel Corporation.
*Other brands and names may be claimed as the property of others.
Copyright © Intel Corporation 2012.
ii Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
iii
Table of Contents
1. Introduction ........................................................................................................................ 1
1.1 Chapter Outline ...................................................................................................... 1
1.2 Server Board Use Disclaimer ................................................................................. 1
1.3 Product Errata ........................................................................................................ 2
2. Product Family Overview ................................................................................................... 3
2.1 Chassis Dimensions ............................................................................................... 5
2.2 System Level Environmental Limits ........................................................................ 6
2.3 System Features and Options Overview ................................................................ 7
2.3.1 Hot Swap Hard Drive Bay and Front Panel Options ............................................... 7
2.3.2 Back Panel Features .............................................................................................. 8
2.3.3 Front Control Panel Options ................................................................................... 8
2.4 Server Board Features Overview ........................................................................... 9
2.5 Available Front Bezel Support .............................................................................. 11
2.6 Available Rack and Cabinet Mounting Kit Options ................................................ 11
3. Power Subsystem ............................................................................................................. 12
3.1 Mechanical Overview ........................................................................................... 12
3.2 Power Connectors ................................................................................................ 14
3.2.1 Power Supply Module Card Edge Connector ....................................................... 14
3.2.2 Riser Card Power Connectors .............................................................................. 14
3.2.3 Hot Swap Backplane Power Connector ................................................................ 15
3.2.4 Optical Drive Power Connector ............................................................................ 15
3.3 Power Supply Module Efficiency .......................................................................... 15
3.4 Power Cord Specification Requirements .............................................................. 16
3.5 AC Input Specifications ........................................................................................ 17
3.5.1 Power Factor ........................................................................................................ 17
3.5.2 AC Input Voltage Specification ............................................................................. 17
3.5.3 AC Line Isolation Requirements ........................................................................... 17
3.5.4 AC Line Dropout / Holdup .................................................................................... 17
3.5.5 AC Line Fuse ....................................................................................................... 18
3.5.6 AC Inrush ............................................................................................................. 18
3.5.7 AC Line Transient Specification ........................................................................... 18
3.5.8 Susceptibility Requirements ................................................................................. 18
3.5.9 Electrostatic Discharge Susceptibility ................................................................... 19
3.5.10 Fast Transient/Burst ............................................................................................. 19
3.5.11 Radiated Immunity ............................................................................................... 19
3.5.12 Surge Immunity .................................................................................................... 19
3.5.13 Power Recovery ................................................................................................... 19
3.5.14 Voltage Interruptions ............................................................................................ 19
Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
3.5.15 Protection Circuits ................................................................................................ 19
3.5.16 Over-current Protection (OCP) ............................................................................. 19
3.5.17 Over-voltage Protection (OVP) ............................................................................. 20
3.5.18 Over-temperature Protection (OTP) ..................................................................... 20
3.6 Cold Redundancy Support ................................................................................... 20
3.6.1 Powering on Cold Standby supplies to maintain best efficiency ........................... 20
3.6.2 Powering on Cold Standby supplies during a fault or over current condition ......... 21
3.6.3 BMC Requirements .............................................................................................. 21
3.6.4 Power Supply Turn On Function .......................................................................... 21
3.7 Closed Loop System Throttling (CLST) ................................................................ 21
3.8 Smart Ride Through (SmaRT) .............................................................................. 22
3.9 Power Supply Status LED .................................................................................... 22
4. Thermal Management ....................................................................................................... 23
4.1 Thermal Operation and Configuration Requirements ............................................ 23
4.2 Thermal Management Overview .......................................................................... 24
4.2.1 Set Throttling Mode .............................................................................................. 24
4.2.2 Altitude ................................................................................................................. 24
4.2.3 Set Fan Profile ..................................................................................................... 25
4.2.4 Fan PWM Offset ................................................................................................... 25
4.2.5 Quiet Fan Idle Mode ............................................................................................. 25
4.2.6 Thermal Sensor Input for Fan Speed Control ....................................................... 25
4.3 System Fans ........................................................................................................ 26
4.4 Power Supply Fans .............................................................................................. 28
4.5 FRUSDR Utility .................................................................................................... 28
5. System Storage and Peripheral Options .........................................................................
29
5.1 2.5” Hard Disk Drive Support ................................................................................ 29
5.1.1 2.5” Drive Hot-Swap Backplane Overview ............................................................ 30
5.1.2 Cypress* CY8C22545 Enclosure Management Controller .................................... 31
5.2 3.5” Hard Disk Drive Support ................................................................................ 32
5.2.1 3.5” Drive Hot-Swap Backplane Overview ............................................................ 33
5.2.2 Cypress* CY8C22545 Enclosure Management Controller .................................... 34
5.3 Optical Drive Support ........................................................................................... 34
5.4 eUSB SSD Support .............................................................................................. 35
5.5 SATA DOM Support ............................................................................................. 35
6. Storage Controller Options Overview ............................................................................. 36
6.1 Embedded SATA / SAS Controller support .......................................................... 36
6.2 Embedded Software RAID Support ...................................................................... 37
®
6.2.1 Intel
6.2.2 Intel
6.3 Intel
Embedded Server RAID Technology 2 (ESRT2) 1 ...................................... 37
®
Rapid Storage Technology (RSTe) 1 ........................................................... 37
®
Integrated RAID Module Support (Available Option) ................................... 38
7. Front Control Panel and I/O Panel Overview .................................................................. 39
iv Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
v
7.1 I/O Panel Features ............................................................................................... 39
7.2 Control Panel Features ........................................................................................ 39
8. Intel
®
Local Control Panel ................................................................................................ 43
8.1 LCD Functionality ................................................................................................. 43
8.2 Main Menu ........................................................................................................... 44
8.3 Event Menu .......................................................................................................... 44
8.4 View Menu ........................................................................................................... 45
8.4.1 System FW Version (SysFwVer) .......................................................................... 45
8.4.2 System Information (SysInfo) ............................................................................... 45
8.4.3 BMC IP Configuration ........................................................................................... 46
8.4.4 RMM4 IP Configuration ........................................................................................ 46
8.4.5 Power ................................................................................................................... 46
8.4.6 Last Post Code (Last PC) ..................................................................................... 46
8.5 Config Menu ......................................................................................................... 46
8.5.1 IP Version ............................................................................................................ 46
8.5.2 BMC IP................................................................................................................. 47
8.5.3 RMM4 IP .............................................................................................................. 48
8.5.4 Boot Device .......................................................................................................... 48
8.5.5 Banner ................................................................................................................. 48
9. PCI Riser Card Support .................................................................................................... 50
9.1 Riser Slot Overview .............................................................................................. 50
9.2 Riser Card Support .............................................................................................. 52
10. Mezzanine I/O Module Support ........................................................................................ 53
Appendix A: Integration and Usage Tips .............................................................................. 54
Appendix B: POST Code Diagnostic LED Decoder ..............................................................
55
Appendix C: POST Code Errors ............................................................................................. 60
Glossary .................................................................................................................................... 65
Reference Documents .............................................................................................................. 66
Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
List of Figures
Figure 1. Chassis Dimensions ..................................................................................................... 5
Figure 2. System Components Overview .................................................................................... 7
Figure 3. 3.5" Hard Drive Bay - 4 Drive Configuration ................................................................. 7
Figure 4. 2.5" Hard Drive Bay - 8 Drive Configuration ................................................................. 7
Figure 5. Back Panel Feature Identification ................................................................................. 8
Figure 6. Front Control Panel Options ......................................................................................... 8
Figure 7. Intel Figure 8. Intel
Figure 9. Optional Front Bezel .................................................................................................. 11
Figure 10. Power Supply Module Mechanical Drawing .............................................................. 13
Figure 11. AC and DC Power Supplies – Connector View ........................................................ 13
Figure 12. Power Supply Module .............................................................................................. 13
Figure 13. AC Power Cord ........................................................................................................ 16
Figure 14. DC Power Cord ........................................................................................................ 16
Figure 15. Fan Control Model .................................................................................................... 26
Figure 16. System Fan Identification ......................................................................................... 26
Figure 17. Server Board System Fan Connector Locations ....................................................... 27
Figure 18. 2.5" Hard Drive Bay Drive Configuration .................................................................. 29
Figure 19. 3.5" Hard Drive Bay Configuration ............................................................................ 32
Figure 20. Optical Drive Support ............................................................................................... 34
Figure 21. Low Profile eUSB SSD Support ............................................................................... 35
Figure 22. InnoDisk* Low Profile SATA DOM ............................................................................ 35
Figure 23. Front I/O Panel Features .......................................................................................... 39
Figure 24. Front Control Panel Features ................................................................................... 40
Figure 25. Intel
Figure 26. Background color during normal scenario ................................................................ 44
Figure 27. Background color during error .................................................................................. 44
Figure 28. Main Menu ............................................................................................................... 44
Figure 29. Event Menu .............................................................................................................. 44
Figure 30. View Menu ............................................................................................................... 45
Figure 31. System Firmware Versions Menu ............................................................................. 45
Figure 32. System Information menu ........................................................................................ 45
Figure 33. BMC IP Configuration .............................................................................................. 46
Figure 34. RMM4 IP Configuration ............................................................................................ 46
Figure 35. Power Consumed by the System Currently .............................................................. 46
Figure 36. Last BIOS Post Code ............................................................................................... 46
Figure 37. Configure Menu Items .............................................................................................. 46
Figure 38. IP Version configuration screen ................................................................................ 47
®
Server Board S2600GZ ....................................................................................... 9
®
Light-Guided Diagnostic LEDs - Server Board .................................................. 10
®
Local Control Panel......................................................................................... 43
vi Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
vii
Figure 39. BMC IP Configuration Menu ..................................................................................... 47
Figure 40. BMC IP Source Configuration Menu......................................................................... 47
Figure 41. Screen shots for Configuring IP Address, Subnet Mask and Gateway ..................... 47
Figure 42. State transition diagram for setting IP Address ......................................................... 48
Figure 43. Boot options configuration menu .............................................................................. 48
Figure 44. Banner configuration menu ...................................................................................... 48
Figure 45. Riser Slot Architecture ............................................................................................. 50
Figure 46. Intel® Server Board S2600GZ/GL PCI Bus Layout Diagram .................................... 51
Figure 47. Add-in Card Support ................................................................................................ 52
Figure 48. Riser Card Assembly ............................................................................................... 52
Figure 49. POST Diagnostic LED Location ............................................................................... 55
Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
List of Tables
Table 1. System Feature Set ....................................................................................................... 4
Table 2. System Environmental Limits Summary ........................................................................ 6
Table 3. Power Supply Module Output Power Connector Pin-out ............................................. 14
Table 4. Riser Slot Power Pin-out ("OPT_12V_PWR_#") .......................................................... 15
Table 5. Hot Swap Backplane Power Connector Pin-out (“HSBP PWR") .................................. 15
Table 6. Peripheral Drive Power Connector Pin-out ("ODD/SSD PWR") ................................... 15
Table 7. 460 Watt AC Power Supply Efficiency ........................................................................ 15
Table 8. 750 Watt AC Power Supply Efficiency ......................................................................... 15
Table 9. AC Power Cord Specifications.................................................................................... 16
Table 10. AC Input Voltage Range ............................................................................................ 17
Table 11. AC Line Sag Transient Performance ........................................................................ 18
Table 12. AC Line Surge Transient Performance ..................................................................... 18
Table 13. Performance Criteria ................................................................................................ 18
Table 14. 460 Watt Power Supply Over Current Protection ...................................................... 19
Table 15. 750 Watt Power Supply Over Current Protection ....................................................... 19
Table 16. Over Voltage Protection (OVP) Limits ...................................................................... 20
Table 17. Example Load Share Threshold for Activating Supplies ........................................... 21
Table 18. LED Indicators ........................................................................................................... 22
Table 19. System Fan Connector Pin-out .................................................................................. 28
Table 20. Drive Status LED States ............................................................................................ 30
Table 21. Drive Activity LED States ........................................................................................... 30
Table 22. Intel® RAID C600 Upgrade Key Options ................................................................... 36
®
Table 23. Supported Intel
Table 24. System Status LED State Definitions......................................................................... 41
Table 25. Power/Sleep LED Functional States .......................................................................... 42
Table 26. POST Progress Code LED Example ......................................................................... 55
Table 27. Diagnostic LED POST Code Decoder ....................................................................... 56
Table 28. MRC Progress Codes ...............................................................................................
Table 29. MRC Fatal Error Codes ............................................................................................. 59
Table 30. POST Error Messages and Handling ......................................................................... 60
Table 31. POST Error Beep Codes ........................................................................................... 64
Table 32. Integrated BMC Beep Codes ..................................................................................... 64
Integrated RAID Modules ................................................................ 38
58
viii Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
ix
< This page intentionally left blank. >
Revision 1.1
1
1. Introduction
Intel® Server System R1000GZ/GL Product Family TPS
This Technical Product Specification (TPS) provides system level information for the Intel® Server System R1000GZ and Intel product families are common, however the server board integrated into them is different. The Intel System R1000GZ product family is integrated with an Intel System R1000GL product family is integrated with the Intel
®
Server System R1000GL product families. The system level features of both these
®
Server Board S2600GZ and the Intel
®
Server Board S2600GL.
®
Server
®
Server
This document will describe the functions and features of the integrated server system which includes the chassis layout, system boards, power sub-system, cooling sub-system, storage sub-system options, and available installable options. Server board specific detail can be obtained by referencing the Intel
®
Server
Board S2600GZ/S26000GLTechnical Product Specification.
In addition, design-level information related to specific server board components / subsystems can be obtained by ordering External Product Specifications (EPS) or External Design Specifications (EDS) related to this server generation. EPS and EDS documents are made available under NDA with Intel and must be ordered through your local Intel
representative. See the Reference Documents section at the end of this document for a
list of available documents.
1.1 Chapter Outline
This document is divided into the following chapters:
Chapter 1 – Introduction Chapter 2 – Product Family Overview Chapter 3 – Power Subsystem Chapter 4 – Thermal Management Chapter 5 – System Storage and Peripherals Drive Bay Overview Chapter 6 – Storage Controller Options Overview Chapter 7 – Front Control Panel and I/O Panel Overview Chapter 8 – Intel Chapter 9 – PCI Riser Card Support Chapter 10 – Mezzanine Module Support Appendix A – Integration and Usage Tips Appendix B – POST Code Diagnostic LED Decoder Appendix C – Post Code Errors Glossary Reference Documents
®
Local Control Panel
1.2 Server Board Use Disclaimer
Intel Corporation server boards support add-in peripherals and contain a number of high-density VLSI and power delivery components that need adequate airflow to cool. Intel development and testing that when Intel will meet the intended thermal requirements of these components. It is the responsibility of the system integrator who chooses not to use Intel operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits.
®
®
server building blocks are used together, the fully integrated system
®
-developed server building blocks to consult vendor datasheets and
Revision 1.1
ensures through its own chassis
1.3 Product Errata
Intel® Server System R1000GZ/GL Product Family TPS
The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Product Errata are documented in the Intel
Board S2600GZGL, Intel
®
Server System R1000GZGL, Intel® Server System R2000GZGL Monthly
®
Server
Specification Update which can be downloaded from Intel.com
2 Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
3
2. Product Family Overview
This generation of Intel 1U server platforms offers a variety of system options to meet the varied configuration requirements of high-density high-performance computing environments. The Intel R1000GZ/GL product families are comprised of several available 1U rack mount server systems that are integrated with either an Intel
®
Server Board S2600GZ or Intel® Server Board S2600GL.
®
Server System
This chapter provides a high-level overview of the system features and available options as supported in different platform SKUs within this server family. Greater detail for each major system component or feature is provided in the following chapters.
Note: The following table lists features common to both server product families. Features that are unique to one product family will be identified by either denoting the server system name or the integrated server board name.
Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
Server System
Integrated Server Board
Feature
Description
Support for one or two Intel® Xeon® processors E5-2600 product family
S2600GL - 16 DIMM slots – 2 DIMMs / Channel – 4 memory channels per processor
Video (back and front video connectors)
One Type-A USB 2.0 connector
Six dual rotor managed system fans
Integrated 2D Video Controller
One eUSB 2x5 pin connector to support 2mm low-profile eUSB solid state devices
Integrated Baseboard Management Controller, IPMI 2.0 compliant
The server system can have up to two power supply modules installed, providing support for the
o
4x – 3.5” SATA/SAS Hot Swap Hard Drive Bays + Optical Drive support
Table 1. System Feature Set
Intel® Server System R1000GZ product family Intel® Server Board S2600GZ
Intel® Server System R1000GL product family Intel® Server Board S2600GL
Processor Support
Memory
Chipset Intel® C602 chipset with support for optional Storage Option Select keys
External I/O connections
Internal I/O connectors / headers
Optional I/O Module support
TDP up to 135 Watts
S2600GZ - 24 DIMM slots – 3 DIMMs / Channel – 4 memory channels per processor
Unbuffered DDR3 (UDIMM), registered DDR3 (RDIMM), Load Reduced DDR3 (LRDIMM)
Memory DDR3 data transfer rates of 800, 1066, 1333 MT/s, and 1600 MT/s
DDR3 standard I/O voltage of 1.5V and DDR3 Low Voltage of 1.35V
RJ-45 Serial- A Port
Four RJ-45 Network Interface Connectors supporting 10/100/1000Mb
USB 2.0 connectors - 3 on back panel + 2 on front panel
One DH-10 Serial-B port connector
The following I/O modules utilize a single proprietary on-board connector. An installed I/O module can be supported in addition to standard on-board features and any add-in expansion cards.
Quad port 1 GbE based on Intel® Ethernet Controller I350 – RMS25CB0080
Dual port 10GBase-T Ethernet module based on Intel
AXX10GBTWLIOM
Dual SFP+ port 10GbE module based on Intel® 82500 10 GbE controller – AXX10GBNIAIOM
Single Port FDR speed InfiniBand module with QSFP connector – AXX1FDRIBIOM
Intel® Quick Assist Accelerator Card - AXXQAAIOMOD
1,2
.
®
Ethernet Controller I350 –
System Fans
Riser Cards
Video
On-board storage controllers and options
Security Intel® Trusted Platform Module (TPM) - AXXTPME5 (Accessory Option)
Server Management
Power Supply Options
Storage Bay Options
One power supply fan for each installed power supply module
Support for two PCIe riser cards. Each riser card slot has support for the following riser card options:
Single add-in card slot – PCIe x16, x16 mechanical
16 MB DDR3 Memory
Two 7-pin single port AHCI SATA connectors capable of supporting up to 6 GB/sec
Two SCU 4-port mini-SAS connectors capable of supporting up to 3 GB/sec SAS/SATA
Intel® RAID C600 Upgrade Key support providing optional expanded SCU SATA / SAS RAID
capabilities
Intel® Integrated RAID module support (Optional)
Support for Intel® Server Management Software
®
Intel
Remote Management Module 4 Lite – Accessory Option
Intel® Remote Management Module 4 Management NIC – Accessory Option
following power configurations: 1+0, 1+1 Redundant Power, and 2+0 Combined Power
Three power supply options:
o AC 460W Gold
o AC 750W Platinum
DC 750W
8x – 2.5” SATA/SAS Hot Swap Hard Drive Bays + Optical Drive support (capable)
4 Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
5
Tool-less rack mount rail kit – Intel Product Code – AXXPRAIL
Supported Rack Mount Kit Accessory Options
Notes:
1) With a system fan failure, processor throttling may occur
2) Processor throttling may occur with systems configured using the following Intel E5-2690 , E5-2643
Value rack mount rail kit – Intel Product Code – AXXVRAIL
Cable Management Arm – Intel Product Code – AXX1U2UCMA (*supported with AXXPRAIL only)
2-post fixed mount bracket kit – Intel Product Code – AXX2POSTBRCKT
2.1 Chassis Dimensions
®
Xeon® E5-2600 product family processors:
Figure 1. Chassis Dimensions
Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
Parameter
Limits
2.2 System Level Environmental Limits
The following table defines the system level operating and non-operating environmental limits.
Table 2. System Environmental Limits Summary
Temperature
Operating ASHRAE Class A2 – Continuous Operation. 10º C to 35º C (50º F to 95º F) with the maximum
rate of change not to exceed 10°C per hour
ASHRAE Class A3 – Includes operation up to 40C for up to 900 hrs per year.
ASHRAE Class A4 – Includes operation up to 45C for up to 90 hrs per year.
Shipping -40º C to 70º C (-40º F to 158º F)
Altitude
Operating Support operation up to 3050m with ASHRAE class deratings.
Humidity
Shipping 50% to 90%, non-condensing with a maximum wet bulb of 28° C (at temperatures from 25° C
to 35° C)
Shock
Operating Half sine, 2g, 11 mSec
Unpackaged Trapezoidal, 25 g, velocity change is based on packaged weight
Packaged Product Weight: ≥ 40 to < 80
Non-palletized Free Fall Height = 18 inches Palletized (single product) Free Fall Height = NA
Vibration
Unpackaged 5 Hz to 500 Hz 2.20 g RMS random
Packaged 5 Hz to 500 Hz 1.09 g RMS random
AC-DC
Voltage 90 Hz to 132 V and 180 V to 264 V
Frequency 47 Hz to 63 Hz
Source Interrupt No loss of data for power line drop-out of 12 mSec
Surge Non-
operating and operating
Line to earth Only AC Leads 2.0 kV
ESD
Air Discharged 12.0 kV
Contact
Discharge
Acoustics Sound Power Measured
Servers/Rack
See the Intel
Power in Watts
Mount BA
®
S2600GZGL Product Family Power Budget and Thermal Configuration Tool for system
configuration requirements and limitations.
Unidirectional
I/O Leads 1.0 kV DC Leads 0.5 kV
8.0 kV
<300 W ≥300 W ≥600 W ≥1000 W
7.0 7.0 7.0 7.0
6 Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
7
2.3 System Features and Options Overview
Figure 2. System Components Overview
2.3.1 Hot Swap Hard Drive Bay and Front Panel Options
Figure 3. 3.5" Hard Drive Bay - 4 Drive Configuration
Figure 4. 2.5" Hard Drive Bay - 8 Drive Configuration
Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
Label
Description
Label
Description
2.3.2 Back Panel Features
Figure 5. Back Panel Feature Identification
2.3.3 Front Control Panel Options
A System ID Button w/Integrated LED F System Status LED
B NMI Button (recessed, tool required for use) G Power Button w/Integrated LED
C NIC-1 Activity LED H Hard Drive Activity LED
D NIC-3 Activity LED I NIC-4 Activity LED
E System Cold Reset Button J NIC-2 Activity LED
8 Revision 1.1
Figure 6. Front Control Panel Options
Intel® Server System R1000GZ/GL Product Family TPS
9
2.4 Server Board Features Overview
The following illustration provides a general overview of the server board, identifying key feature and component locations. The majority of the items identified are common between the Intel
®
Server Board
S2600GL and S2600GZ.
Figure 7. Intel® Server Board S2600GZ
Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
Label
Description
Label
Description
A System ID I System Fan #3 Fan Fault
B System Status J Memory Fault
C POST Code Diagnostics K System Fan #2 Fan Fault
D 12V Stand-by Power Present L System Fan #1 Fan Fault
E CPU-2 Fault M CPU-1 Fault
F System Fan #6 Fan Fault N CATERR
G System Fan #5 Fan Fault O System Power Good
H System Fan #4 Fan Fault
Figure 8. Intel® Light-Guided Diagnostic LEDs - Server Board
10 Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
11
2.5 Available Front Bezel Support
The optional front bezel is made of molded plastic and uses a snap-on design. When installed, its design allows for maximum airflow to maintain system cooling requirements. The face of the bezel assembly includes optional snap-in identification badge and wave (shown) features to allow for customization.
(Intel Product Order Code – A1UBEZEL)
Figure 9. Optional Front Bezel
2.6 Available Rack and Cabinet Mounting Kit Options
Tool-less rack mount rail kit – Intel Product Code – AXXPRAIL
o 1U and 2U compatible o 65 lbs max support weight o Tool-less installation o Full extension from rack o Drop in system install o Optional cable management arm support
Value rack mount rail kit – Intel Product Code – AXXVRAIL
o 1U to 4U compatible o 130 lbs max support weight o Tool-less chassis attach o Tools required to attach to rails to rack o 2/3 extension from rack
Cable Management Arm – Intel Product Code – AXX1U2UCMA (*supported with AXXPRAIL only)
2-Post Fixed mount bracket kit – Intel Product Code - AXX2POSTBRCKT
Revision 1.1
Intel® Server System R1000GZ/GL Product Family TPS
3. Power Subsystem
This chapter provides a high level overview of the power management features and specification data for the power supply options available for this server product. Specification variations will be identified for each supported power supply.
The server system can have upto two power supply modules installed, supporting the following power supply configurations: 1+0 (single power supply), 1+1 Redundant Power, and 2+0 Combined Power (non-redundant). 1+1 redundant power and 2+0 combined power configurations are automatically configured depending on the total power draw of the system. If the total system power draw exceeds the power capacity of a single power supply module, then power from the 2 redundancy is lost. In a 2+0 power configuration, total power available maybe less then twice the rated power of the installed power supply modules due to the amount of heat produced with both supplies providing peak power. Should system thermals exceed programmed limits, platform management will attempt to keep the system operational. See Closed Loop System Throttling (CLST) later in this chapter, and Chapter 4 Thermal Management, for details.
There are three power supply options available for this server product: 460W AC, 750W AC, 750W DC.
The power supplies are modular, allowing for tool-less insertion and extraction from a bay in the back of the chassis. When inserted, the card edge connector of the power supply mates blindly to a matching slot connector on the server board.
nd
power supply module will be utilized. Should this occur, power
In the event of a power supply failure, redundant 1+1 power supply configurations have support for hot-swap extraction and insertion.
The AC input is auto-ranging and power factor corrected.
3.1 Mechanical Overview
The physical size of the power supply enclosure is 39/40mm x 74mm x 185mm. The power supply contains a single 40mm fan. The power supply has a card edge output that interfaces with a 2x25 card edge connector in the system.
12 Revision 1.1
13
74mm
FCI 2x25 card
edge connector
10035388-102
A25
A1
B25
B1
2mm
Retention Latch
Airflow direction
8.5mm
39mm
40mm fan
11mm
185mm
Intel® Server System R1000GZ/GL Product Family TPS
Figure 10. Power Supply Module Mechanical Drawing
Figure 12. Power Supply Module
Figure 11. AC and DC Power Supplies – Connector View
Revision 1.1