Intel NSC2U User Manual

®
Intel
Configuration Guide System / Spares / Accessories List
March 2008 Rev 2.2
Reference guide to assist customers and the field in ordering the servers, accessories and spares
IP Network Server NSC2U
~Subject to Change Without Notice~
March 2008
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, life sustaining applications.
Intel may make changes to specifications and product descriptions at any time, without notice.
Intel server boards, server chassis, and processors may contain design defects or errors known as errata, which may cause the product to deviate from published specifications. Current characterized errata are available on request.
Intel, Intel Xeon, Pentium, and the Intel logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
*Other names and brands may be claimed as the property of others.
Copyright © 2008, Intel Corporation
Revision History
Revision Date Comments
1.0 June 2007 Initial Production version
2.0 March 2008 Updated to reflect added support for Xeon 5400 processor series; updates to spares section; format/structure changes.
2.1 March 2008 Includes ordering details for L5410 processor (NDA).
2.2 March 2008 Updated for public availability of L5410 processor support.
Table of Contents
I. INTRODUCTION ..............................................................................................4
II. PRODUCTION SYSTEM SKUS...................................................................5
III. PRODUCTION SPARES/ACCESSORIES LIST................................10
IV. QUAD PORT BYPASS NIC CAPABILITY .............................................13
APPENDIX A. RACK MOUNTING OPTIONS FOR 1U AND 2U INTEL®
COMMUNICATIONS RACK MOUNT SERVERS..............................................15
3/28/2008 v 2.2 3 of 20

I. Introduction

Product Description:
The Intel® IP Network Server NSC2U system is the second generation product of 2U Intel® IP Network Server products, having long product life and 20-inch depth chassis. This server combines network port density and processor performance in a compact 2U package. The NSC2U supports a number of processor speeds for the Quad-Core Intel with power efficiency to provide improved performance-per-watt over previous­generation rack-mount servers. The NSC2U also supports a number of processor speeds for the Dual-Core Intel
The NSC2U is an excellent choice for network data applications with large I/O requirements, while providing extended lifecycle support, DC power capabilities, compact form factor, and the ruggedness found on carrier-grade servers. Ideal for network security, it is an excellent choice for intrusion detection/intrusion prevention, VPN/firewall, and unified threat management solutions. In addition, it is a valuable platform for running Telco SoIP, including IMS, IPTV, Video on Demand (VoD), SIP application servers, IP-PBX, and IP-PSTN Gateways. Other network applications well-suited for this platform are enterprise application acceleration and content caching.
More product information is available at the following websites:
NSC2U Product Overview:
http://www.intel.com/design/telecom/products/cbp/ipserver/NSC2U/overview.htm
NSC2U Product Support:
http://www.intel.com/support/telecom/computeboards/nsc2u/
Purpose of this Document:
This document provides details on what parts are available for ordering of the Intel® IP Network Server NSC2U production systems. This includes PID and MM# information for System SKUs, Accessories & Spares, as well as other Intel parts that are supported by the NSC2U product.
Supported third-party components are not covered by this document, and may be found in the Tested Hardware and Operating System List (THOL) for this product.
®
Xeon® 5300 and 5400 series processors, coupling high performance
®
Xeon® 5100 series processors.
3/28/2008 v 2.2 4 of 20

II. Production System SKUs

The NSC2U Production System SKUs that can be ordered are listed below:
Product Identification Code
Description MM#
Min. Order
Qty.
NSCA0201W
NSCD0201W
Intel® IP Network Server NSC2U, Base Model 0 with AC Power Supply
Intel® IP Network Server NSC2U, Base Model 0 with DC Power Supply
889358 1
889357 1
See the NSC2U Base Model 0 Configuration table further down in this section for a list of components included in each base model 0 SKU.
Production SKUs are offered as either an AC or DC version. The Product Identification code, or PID, of all SKUs contains either the letter “A” for AC or “D” for DC as the 4th digit of the PID.
Both Production SKUs are base model 0 SKUs, (no processor, heatsink, memory, hard drive, power cord, operating system, or plug-in adapters are provided). Those components must be ordered separately as Accessories from Intel or from third party vendors listed in the Tested Hardware and Operating System List (THOL).
Power Cords are not included with the Mod 0 system. For AC Power cords, order the NA – North American power cord below. This power cable is RoHS-compliant.
PID MM# Comments
PWRCABLEUS 816324
Note: Ensure that customers have the appropriate technical support and contact before placing their first order.
This AC power cable can be ordered by North America (NA) customers. International customers should procure their specific power cords directly.
3/28/2008 v 2.2 5 of 20
NSC2U Base Model 0 Configuration:
All Production SKUs are base model 0 SKUs (no processor, heatsink, memory, hard drive, power cord, operating system, or plug-in adapters are provided). Those components must be ordered separately as Accessories from Intel or from third party vendors listed in the Tested Hardware and Operating System List (THOL).
The table below lists which components are included in the base model 0 SKUs and which ones must be ordered separately or as optional accessories.
Component Description
AC Mod 0
Configuration
AC power supply (600 W) 1 included ­DC power supply (600 W) - 1 included Filler Panel in 2nd power supply bay 1 included Chassis (bezel, sheet metal, top cover, PCI carrier) 1 included Server Board T5000PAL 1 included Bezel (gray) 1 included PCI Riser FH-FL (two PCI-Express and one PCI-X slots) 1 included PCI Riser LP (two PCI-Express slots) 1 included FB-DIMM slots (memory not included) 8 included Trays for hot-swap 2.5” SAS Hard Disk Drives 6 included Filler Panel in optical device bay 1 included Rear Panel GbE NIC (Cu) ports (via Server Board) 2 included Server Deployment Toolkit (CD) 1 included Quick Start Guide 1 included Power Cable Purchase separately1 SW RAID 0/1/10 Included HW RAID 5 Optional Accessories2 Intel® Z-U130 Value Solid State Drive Optional Accessory2 Mounting kit for Intel® Z-U130 Value Solid State Drive Optional Accessory2 Remote Management Module 2 Optional Accessory2 PCI-X FH-FL Riser (3 PCI-X slots) Optional Accessories2 Ethernet I/O Module (dual Gigabit rear ports) Optional Accessory2 SAS I/O Expansion Module (x4 external rear port) Optional Accessory2 Rack Mount Kits Optional Accessory4 Processor (refer to “Details on Ordering Processors”) Purchase separately5 Heatsink Accessory or purchase separately Memory Purchase separately5 Hard Disk Drive Purchase separately5 Optical Drive Purchase separately5
Accessories for NIC-in-Front Capability3
Quad Port Bypass Adapter (Copper) Optional Accessory3 Quad Port Bypass Adapter (Fiber) Optional Accessory3 Quad NIC-in-Front Mounting Kit (Copper) Optional Accessory3 Quad NIC-in-Front Mounting Kit (Fiber) Optional Accessory3
1
Refer to AC power cord accessory in this section
2
Refer to “Production Spares/Accessories List” in section III
3
Refer to “Quad Port Bypass NIC Capability” in section IV
4
Refer to “Rack Mounting Options” in the Appendix
5
Should be purchased separately (parts not listed in this document)
DC Mod 0
Configuration
3/28/2008 v 2.2 6 of 20
Notes on the NSC2U Model 0 Configuration and Options:
PCI Risers
o The base configuration comes standard with two PCI Risers supporting up
to five PCI slots. These include:
¾ One low-profile riser supporting two PCI-Express (PCIe) slots ¾ One full-height, full-length riser supporting three slots: two PCIe
x4 and one PCI-X.
o Additional full-height, full-length risers (below) are supported and
available as accessories (refer to “Production Spares/Accessories List” in section III).
¾ PCI-X (active): three independent PCI-X, each with maximum 133
MHz
¾ PCI-X (passive): two PCI-X with maximum 100 MHz and one PCI-X
(66 MHz) all on a shared PCI bus
HW RAID
o While SW RAID 0/1/10 is supported on the base configuration, HW RAID 5
support can be enabled via a set of optional accessories (refer to “Production Spares/Accessories List” in section III).
o Components required are NSCRAID01W (NSC2U RAID5 Kit – includes the I-
Button (license), battery cable) and the AXXMINIDIMM (128 MB Mini DIMM registered DDR-2 for RAID cache.)
o An additional option is the AXXRSBBU3 (Intel® RAID Smart Battery Backup
module provides up to 72 hours of cache memory retention when used with AXXMINIDIMM). The cable to connect the battery is included in the NSCRAID01W kit.
Intel® Z-U130 Value Solid State Drive
o Support for the Intel® Z-U130 Value Solid State Drive is available via a
selection of optional accessories (refer to “Production Spares/Accessories List” in section III).
o Components required are an Intel® Z-U130 Value Solid State (select
desired capacity) as well as a mounting kit (TMWVSSDRIVE01W) to mount it inside the chassis.
o Solid state drives are available in several sizes, enabling an array of
product customization options. These drives securely mount inside the chassis offering
¾ Storage: independent of traditional disk drives ¾ Boot OS from solid state drive; store data on hard drive ¾ Store backup image of boot drive ¾ Add a server partition to the server ¾ Any other customer design options
3/28/2008 v 2.2 7 of 20
IO Option Modules
o These modules, available as optional accessories, attach to the system
board via a proprietary connector, and provide additional IO through the rear bulkhead.
¾ The AXXGBIOMO option module provides two Gigabit Ethernet NICs. ¾ The AXXSASIOMOD option module provides one x4 external SAS
port.
o For ordering details, refer to “Production Spares/Accessories List” in
section III.
Quad Port Bypass NIC Capability
o The NSC2U is capable of supporting up to eight ports of front or rear-
accessible Gigabit Ethernet (either Copper or Fiber) using Quad NIC adapters designed by Intel. Optional accessories are available to enable these features. For more information and ordering details, refer to “Quad Port Bypass NIC Capability” in section IV.
For more detailed information on the NSC2U, refer to the web links below.
Additional Product Details
Check the following web site for more information on the NSC2U:
http://www.intel.com/design/telecom/products/cbp/ipserver/NSC2U/overview.htm
Support.Intel.Com Users
Product information including specifications, compatibility, user’s guides, drivers, firmware, and software associated with the Intel® Network Server NSC2U is available from Intel Customer Support.
Intel® Network Server NSC2U Support Web Site
http://www.intel.com/support/telecom/computeboards/nsc2u/
If you can not access the documents using the links provided, please contact your FAE/FSE for assistance.
3/28/2008 v 2.2 8 of 20
Details on Ordering Processors:
The NSC2U is designed for the Quad-Core Intel® Xeon® 5400 and 5300 processor series, and also supports selected SKUs from the Dual-Core Intel® Xeon® 5100 series processors. Ordering details for the supported processors for the NSC2U are listed below. These include the choice of either Tray (for OEMs) or Boxed (Retail channel) processors.
Intel® Xeon® Processors Supported by NSC2U:
Number
E5440 Yes Quad 2.83 GHz 80W 1333 MHz BX80574E5440P 894824 EU80574KJ073N 893484 L5410 Yes Quad 2.33 GHz 50W 1333 MHz BX80574L5410P 894835 EU80574JJ053N 893491 E5345 Yes Quad 2.33 GHz 80W 1333 MHz BX80563E5345P 892334 HH80563QJ0538M 891115 E5335 Yes Quad 2.00 GHz 80W 1333 MHz BX80563E5335P 892335 HH80563QJ0418M 891116
E5320 No Quad 1.86 GHz 80W 1066 MHz BX80563E5320P
E5310 No Quad 1.60 GHz 80W 1066 MHz BX80563E5310P
5160 No Dual 3.00 GHz 80W 1333 MHz BX805565160P 892200 HH80556KJ0804M 891706
5140 Yes Dual 2.33 GHz 65W 1333 MHz BX805565140P 892169 HH80556KJ0534M 891730 5130 Yes Dual 2.00 GHz 65W 1333 MHz BX805565130P 884531 HH80556KJ0414M 891731
LV 5128 Yes Dual 1.86 GHz 40W 1066 MHz
Long
Life Cores Speed TDP FSB
Notes:
Although all of the above processors have been certified on the NSC2U, Intel recommends the
use of the following processors from Intel’s Embedded Communications and Processor Division (ECG) for long availability and support:
Boxed Processor Tray Processor Processor
Product Code MM# Product Code MM#
892337 HH80563QH0368M 891118 892333 HH80563QH0258M 891121
N/A N/A HH80556JH0364M 891704
o E5440 (Quad-Core, 2.83 GHz, 1333 MHz FSB, TDP=80 W) o L5410 (Quad-Core, 2.33 GHz, 1333 MHz FSB, TDP=50W) o E5345 (Quad-Core, 2.33 GHz, 1333 MHz FSB, TDP=80 W) o E5335 (Quad-Core, 2.00 GHz, 1333 MHz FSB, TDP=80 W) o 5140 (Dual-Core, 2.33 GHz, 1333MHz FSB, TDP=65W) o 5130 (Dual-Core, 2.00 GHz, 1333MHz FSB, TDP=65W) o LV 5128 (Dual-Core, 1.86 GHz, 1066MHz FSB, TDP=40W)
Heatsinks
o This product requires Passive heatsinks. The boxed processors listed above include a
Passive Heatsink Kit, made of aluminum. Do not use Active Fan Heatsinks, which are provided in some Retail Boxed Processors.
o For Tray processors, you will need to procure a Heatsink for each processor (see
NSCSNKCLP01 in the Spares/Accessories list below). This is a copper heatsink. There are no clips needed for this heatsink, since the heatsink includes captive screws.
o If ordering other Boxed Processors (not listed here), do not use the fansink, which
might be included.
Note that processor product codes can change, and that the above is a snapshot current as of
3/28/2008. Please consult with your Intel representative for SSpec or MM# which might be needed for ordering the processor. Any differences in functionality are reported in the Monthly Specification updates available at http://developer.intel.com.
3/28/2008 v 2.2 9 of 20

III. Production Spares/Accessories List

Below are the Spare parts and Accessories that can be ordered with the NSC2U system. Any of these parts can be ordered as spares for part replacement purposes or as additional customer inventory. Some of the parts below are not included in the NSC2U system base model and can be ordered as accessories for purposes of upgrading the base model to include additional features.
For a listing of additional compatible accessories, such as Optical Devices for use with the CD-ROM carrier, please refer to the Tested Hardware and Operating System List (THOL).
Included in
PID Order Code Description Contents
TLIACPSU003 TLIDCPSU003 NSCSNKCLP01
NSCBEZEL01W
NSCESCBLNK01W
HW RAID
NSCRAID01W
AXXRSBBU3
AXXMINIDIMM
Remote Management
AXXRMM2
AXXRMM2BULK
TIGI2U AC Power Supply TIGI2U DC Power Supply NSC2U Processor Heatsink
NSC2U Bezel (Unpainted), 12-pack
NSC2U Blank Escutcheons (unpainted) – 48 pack
NSC2U RAID5 Kit
Intel® RAID Smart Battery Backup module: for use with Intel® Integrated Server RAID (requires NSCRAID01W plus mini DIMM), provides up to 72 hours of cache memory retention when used with AXXMINIDIMM.
128 MB Mini DIMM registered DDR-2 for RAID cache. Note: enabling RAID capability also requires Intel RAID Activation Key– NSCRAID01W
Intel® Remote Management Module 2 (RMM2) - Single Pack
Intel Remote Management Module 2 (RMM2) – 10-Pack
AC power supply DC power supply,
input power connector Heat sink (copper)
Bezel, packaged in cartons of 12
Unpainted blank escutcheon panel
(filler panel if front­NICs are not present)
I-Button (license), battery cable (battery
or mini-DIMM not included)
Battery backup kit
Mini-DIMM
RMM2 with GCM (single-pack)
RMM2 with GCM (10­pack)
Base Model
(Y/N)
Y (one in AC Y (one in DC
2 blank panels
installed in base
SKU)
SKU)
N
Y
(one bezel)
model
N
N
N
N
N
MM#
880110 880116 891200
889820
897011
890202
883471
881258
894383
894385
Min.
Order
Qty
1 1 1
12
(order in
multiples
of 12)
48
(order in
multiples
of 48)
1
5
(order in
multiples
of 5)
5
(order in
multiples
of 5)
1 1
(specify
‘1’ for
each 10-
pack)
3/28/2008 v 2.2 10 of 20
Production Spares/Accessories List (continued)
Included in
PID Order Code Description Contents
PCI Risers and I/O Options
ASR2500FHR
SR2400 (2U) Full Height PCI-Express riser (two PCI-Express slots, one PCI­X slot)
Riser
Base Model
(Y/N)
Y
MM#
880515
Min.
Order
Qty
1
ADRACTRIS
ADRPCIXRIS
FSR2500LPR
AXXGBIOMOD
AXXSASIOMOD
Solid State Drives
TMWVSSDRIVE01W
SSDUSMS0001GL10
SSDUSMS0002GL10
SR2500 (2U) Full Height PCI-X "active" high performance riser card (three PCI-X slots)
SR2500 (2U) Full Height PCI-X “passive” riser card (three PCI-X slots)
Two-slot Low Profile PCI-Express riser
Dual Gigabit Ethernet I/O Module
Four-port external SAS I/O Expansion Module
Mounting kit for Intel® Z-U130 Value Solid State Drive
Requires Intel® Z-U130 Value Solid State Drive (purchased separately).
Intel® Z-U130 Value Solid State Drive
- 1 GB, Low Profile Connector
Requires TMWVSSDRIVE01W
Intel® Z-U130 Value Solid State Drive – 2 GB, Low Profile Connector
Requires TMWVSSDRIVE01W
Riser
Riser
Riser
Dual Gigabit rear ports
x4 external rear port
Interposer board, cable, mounting screws (flash drive not included)
1 GB Module – Low Profile Connector
2 GB Module – Low Profile Connector
N
N
Y
N
N
N
N
N
856546
863135
880516
880518
880517
893165
890945
890943
1
1
1
1
1
1
10
10
SSDUSMS0004GL10
Spares
NSCPWRDISBDW
NSCFPIOBDLPW NSCSASBSBDW
NSCSASBKPLNW NSCBRIDGEBDW
3/28/2008 v 2.2 11 of 20
Intel® Z-U130 Value Solid State Drive
- 4 GB, Low Profile Connector
Requires TMWVSSDRIVE01W
NSC2U Power Distribution Board
NSC2U Front Panel IO Board with LED pipe
NSC2U T5000PAL Server board NSC2U SAS Backplane NSC2U Bridge board
4 GB Module – Low Profile Connector
Power distribution board, with integrated wire harness
Board, set of front panel light pipes
Board Backplane Board, insulator
N
Y
Y
Y Y Y
890941
889805
889812 889828
889829 889852
10
1
1
1 1 1
Production Spares/Accessories List (continued)
Included in
PID Order Code Description Contents
Base Model
(Y/N)
Spares
Flex cable (SAS interface, front panel signals), front panel
NSCCBLMSCW
NSCFANSETW
NSCDVDENGTABW
FXX25HDDCAR
NSC2U System Interconnect Cable Kit
NSC2U Fan Assembly (set of four)
NSC2U DVD Drive Engagement Tab
TIGW1U SAS HDD carrier
power cable, serial port cable, CD-ROM cable, alarm cable, TAM module cable
80 mm CPU fans (2), 40 mm PCI fans (2), plastic fasteners (8)
Blue plastic engagement bracket and black plastic locking clip, screws
Carrier, black plastic filler, screws (4)
Y
Y
Y
Y
Note: There are also accessories/spares specific to Quad Port Bypass NIC capability. For these items, please refer to Section IV “Quad Port Bypass NIC Capability”.
MM#
889819
889822
889845
881681
Min.
Order
Qty
1
1
1
10
(order in
multiples
of 10)
3/28/2008 v 2.2 12 of 20

IV. Quad Port Bypass NIC Capability

This section is intended for customers that plan to use the Quad Port NIC with Bypass capability on the NSC2U. It describes what parts must be ordered to enable this capability.
The NSC2U is capable of supporting:
Up to eight ports of front-accessible Gigabit Ethernet (either Copper or Fiber) using Quad NIC adapters designed by Intel. The front-accessible NIC configuration also requires the purchase of an internal cabling/mounting kit including an escutcheon for securing the front ports.
Up to eight ports of rear-accessible Gigabit Ethernet (Copper or Fiber) using Quad NIC adapters also designed by Intel.
The Quad Bypass adapters and the cabling/mounting kits come in packages of five units each. These kits include five of the NIC cables designed for the NSC2U system, as well as the escutcheons, cable management bracket, and associated screws to complete the installation of the Bypass adapter in the system. Also there are bulk pack (48 count) escutcheon kits (copper, fiber, and filler panel) available to streamline the customization and painting process of the system.
Below are the Accessories that may be ordered to enable the Quad Port Bypass NIC capability on the NSC2U system. Note: For a list of other tested Network Interface Cards
(NICs) refer to the Tested Hardware and Operating System List (THOL).
PID
Order Code
Description Contents
Copper NIC
Quad-port design, based on two Intel® 82571GB dual-port PCI Express* GbE controllers
Quad-port design, based on two Intel® 82571GB dual-port PCI Express* GbE controllers
Quad NIC-in-front cable assembly, escutcheon and screws for copper ports, cable management bracket and screw
Unpainted escutcheons for use with NSCCBLFNICW
Intended for prep (painting) purposes.
EXPI9014PTBLK (Bypass rear access)
EXPI9024PTBLK (Bypass NIC-in-front)
NSCCBLFNICW
NSCESCCPR01W
Intel® PRO/1000 PT Quad Port Bypass Adapter (Copper) – 5 Pack
Intel® PRO/1000 PT Quad Port Bypass Adapter (Copper, NIC-in­Front) – 5 Pack
NSC2U Quad NIC-in-Front Mounting Kit (Copper) – 5 Pack
NSC2U Escutcheons for Copper ports (unpainted) – 48 Pack
Included in
Base Model
(Y/N)
N
N
N
N
Note: Five
escutcheons are
included in
NSCCBLFNICW
MM#
876697
876699
890325
898020
Min.
Order
Qty
5
5
5
(order in
multiples
of 5)
48
(order in
multiples
of 48)
3/28/2008 v 2.2 13 of 20
PID
Order Code
Fiber NIC
EXPI9014PFBLK (Bypass rear access)
EXPI9024PFBLK (Bypass NIC-in-front)
NSCCBLFNICFBRW
Description Contents
Quad-port design,
Intel® PRO/1000 PF Quad Port Bypass Adapter (Fiber) – 5 Pack
Intel® PRO/1000 PF Quad Port Bypass Adapter (Fiber, NIC-in­Front) – 5 Pack
NSC2U Quad NIC-in-Front Mounting Kit (Fiber) – 5 Pack
based on two Intel® 82571GB dual-port PCI Express* GbE controllers Quad-port design, based on two Intel® 82571GB dual-port PCI Express* GbE controllers
Quad NIC-in-front escutcheon, and LED cable for fiber ports, cable management bracket and screw
Included in Min.
Base Model MM# Order
(Y/N) Qty
N
N
N
876696
876694
897002
5
5
5
(order in
multiples
of 5)
NSCESCFBR01W
NSC2U Escutcheons for Fiber ports (unpainted) – 48 Pack
Unpainted escutcheons for use with NSCCBLFNICFBRW
Intended for prep (painting) purposes.
N
Note: Five
escutcheons are
included in
NSCCBLFNICFBRW
898021
Miscellaneous
NSCESCBLNK01W
NSC2U Escutcheons filler panel (unpainted) – 48 pack
Unpainted blank escutcheon panel
(filler panel if front­NICs are not present)
2 blank panels
installed in base
model
897011
Overview of Intel® PRO/1000 Quad Port Bypass Server Adapters:
The Intel® PRO/1000 PT and PF Quad Port Bypass Server Adapters provide in-line server appliances, such as Intrusion Protection Servers (IPSes), with high-performance, low-latency, in-line connectivity, and a bypass mode to ensure business continuity. These adapters also use the PCI Express* serial bus for greater throughput, and they support Intel® I/O Acceleration Technology (Intel® I/OAT) for further performance enhancement, including the reduced overhead so important to IPS applications.
The Intel® PRO/1000 PT and PF Quad Port Bypass Server Adapters are intended for use by equipment manufacturer hardware designers in application-specific in-line server appliances, where a bypass mode is desirable. Given that equipment manufacturers typically write specific software applications for their in-line platforms, Intel only provides open source reference drivers for these adapters. Interested hardware designers may contact their local Intel representative for additional product or purchase information.
More information on Intel® PRO/1000 Quad Port Bypass Server Adapters is available at:
48
(order in
multiples
of 48)
48
(order in
multiples
of 48)
http://www.intel.com/network/connectivity/products/pro1000_quad_bypass_server_ad apters.htm
3/28/2008 v 2.2 14 of 20

Appendix A. Rack Mounting Options for 1U and 2U Intel® Communications Rack Mount Servers

Rack mounting kits for 2-post or 4-post, 19-inch or 23-inch racks are offered for this product. Please refer to the tables below for the correct options to suit your needs.
All rack mount kits listed are suitable for 1U and 2U Intel® Communications Rack Mount Servers. Installation instructions are included in each kit.
2-post Rack Mounting Kit Options
Rack width Post depth Rack fastener hole spacing
Applicable kits:
19 inch 23 inch 3 inch 5 inch EIA-Wide
TMLCMOUNT21
TMLPMOUNT41
TMLPMOUNT51
TMLPMOUNT52
EIA-Universal ETSI
4-post Rack Mounting Kit Options
Rack width
Applicable kits:
19 inch 23 inch
TMLPMOUNT41 20 24
TMLPMOUNT51 20 24
TMLPMOUNT52 20 24
TMLPSLIDE01 22.5 28 or 34
The TMLPSLIDE01 kit contains server securing brackets. The rails and other options for
Front-post to
rear-post distance
Min
(inches)
Max
(inches)
††
Rack fastener
hole spacing
EIA-
Wide
EIA-
Universal
ETSI
mounting the server are available through other venders such as Accuride (http://www.accuride.com/index2.php
††
34-inch span requires the optional Accuride "Long Bracket" kit.
).
3/28/2008 v 2.2 15 of 20
TMLCMOUNT21
The TMLCMOUNT21 kit mounts Intel® Communication Rack Mount Servers to a 2-post, central office type, 19-inch wide rack. This kit consists of L-shaped brackets that fasten to the sides of the server and to the rack.
TMLCMOUNT21
3/28/2008 v 2.2 16 of 20
TMLPMOUNT41, TMLPMOUNT51 and TMLPMOUNT52
TMLPMOUNT41/51/52 series mounts Intel® Communication Rack Mount Servers to 2-
post or 4-post racks.
TMLPMOUNT41 and TMLPMOUNT51 are used for mounting servers on 19-inch wide racks.
These racks are considered standard EIA (universal hole spacing) racks.
TMLPMOUNT52 is used for mounting servers on 23-inch wide racks. These racks could be
standard EIA (universal or wide hole spacing) or ETSI (European) racks.
TMLPMOUNT41/51/52 series are designed with a slide-in rail-type system. Although the
mounts are designed as rails, they are not sliding rails. This means the servers can be slid into the racks for installation purpose, but the rails are not designed to support a mounted server during service.
TMLPMOUNT4x/5x Feature Comparison
Slide pull-out
locking feature
TMLPMOUNT41 No
TMLPMOUNT51 Yes
TMLPMOUNT52 Yes
1
material
Slide interface
Plastic strips2
Xylan
coating3
Xylan
3
coating
spacing
4-post rack hole
EIA-Universal
EIA-Wide or EIA-
Universal4
EIA-Wide, EIA-
Universal or ETSI
2U-tall nut bar
Not
included
Included5
Included
5
access6
location
2-post chassis
securing screw
Side
Front
access
Front
access
Interference
No Interference
Notes:
1. Extra care must be exercised with TMLPMOUNT41 to securely hold the server with one's hands
when sliding it out of the rack; otherwise, the server could fall to the ground as it is being removed.
2. Plastic strips on TMLPMOUNT41 have peeled off in some customer installations. The result of
this is that the parts are usable, but the server could have somewhat of a "scrape-in feel" rather than "slide in". Also, the rails will fit sloppier, so the side-located chassis securing screws could be difficult to align in 2-post installations. Replacement material is available from the plastic strip manufacturer.
3. Xylan is a tough, low-friction coating similar to Teflon.
4. EIA-Wide spacing doesn't have the interstitial hole that is present in EIA-Universal.
TMLPMOUNT51 contains an adapter bracket to overcome this EIA-Wide issue.
5. This component (2U Nut Bar) enables installation of a rail kit into a 1U rack slot when there is
already equipment installed both above and below that open slot.
6. The sides of the server must be accessible when using TMLPMOUNT41 in 2-post racks.
rack
"HP Mulan
interference"
N/A
3/28/2008 v 2.2 17 of 20
The diagrams above summarize the components and “slide-in rail-type” system of the TMLPMOUNT41. It can be adapted for a 2-post or 4-post installation.
3/28/2008 v 2.2 18 of 20
The main difference between the TMLPMOUNT41 and TMLPMOUNT51/52 series is that the TMLPMOUNT41 series uses a screw to lock the server in place using the Universal Mounting Bracket, whilst the TMLPMOUNT51/52 series has an additional Slide Pull-Out Locking feature.
Universal Front Mounting Bracket on the TMLPMOUNT41
Slide Pull-Out Locking feature on the TMLPMOUNT51/52
3/28/2008 v 2.2 19 of 20
TMLPSLIDE01
The TMLPSLIDE01 is an accessory kit designed for use in conjunction with slide rails to produce a rack mounted serviceable server. The TMLPSLIDE01 kit contains two Universal Front Mounting Brackets that secure the server to the front of the rack. The sliding rails and optional mounting brackets required to mount the server must be purchased through the channel. For example, the Accuride 22-inch Model 305A-LR slide rails are designed to mount a server for “in-rack service.” This example would also use an Accuride mounting bracket kit and the TMLPSLIDE01.
Universal Front Mounting Bracket with securing tab
Note: Using slide rails could result in non-compliance with Seismic Zone 4 requirements of NEBS-3 certification.
Ordering Information
PID Non-RoHS MM# RoHS MM#
TMLCMOUNT21 862501 881904 10
TMLPMOUNT41 838890 881907 10
TMLPMOUNT51 851760 881934 1
TMLPMOUNT52 851745 881935 1
TMLPSLIDE01 845583 881915 10
Customers should order RoHS items for shipments going to the European Union (EU).
Although these mounts have been designed for industry standard racks, please consult with your Intel Field Application or Sales Engineer before selecting racks for these servers.
Compatible rack mounting kits can also be obtained from 3rd party suppliers.
Minimum Order
Quantity
3/28/2008 v 2.2 20 of 20
Loading...