Intel NSC2U User Manual

®
Intel
Configuration Guide System / Spares / Accessories List
March 2008 Rev 2.2
Reference guide to assist customers and the field in ordering the servers, accessories and spares
IP Network Server NSC2U
~Subject to Change Without Notice~
March 2008
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, life sustaining applications.
Intel may make changes to specifications and product descriptions at any time, without notice.
Intel server boards, server chassis, and processors may contain design defects or errors known as errata, which may cause the product to deviate from published specifications. Current characterized errata are available on request.
Intel, Intel Xeon, Pentium, and the Intel logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
*Other names and brands may be claimed as the property of others.
Copyright © 2008, Intel Corporation
Revision History
Revision Date Comments
1.0 June 2007 Initial Production version
2.0 March 2008 Updated to reflect added support for Xeon 5400 processor series; updates to spares section; format/structure changes.
2.1 March 2008 Includes ordering details for L5410 processor (NDA).
2.2 March 2008 Updated for public availability of L5410 processor support.
Table of Contents
I. INTRODUCTION ..............................................................................................4
II. PRODUCTION SYSTEM SKUS...................................................................5
III. PRODUCTION SPARES/ACCESSORIES LIST................................10
IV. QUAD PORT BYPASS NIC CAPABILITY .............................................13
APPENDIX A. RACK MOUNTING OPTIONS FOR 1U AND 2U INTEL®
COMMUNICATIONS RACK MOUNT SERVERS..............................................15
3/28/2008 v 2.2 3 of 20

I. Introduction

Product Description:
The Intel® IP Network Server NSC2U system is the second generation product of 2U Intel® IP Network Server products, having long product life and 20-inch depth chassis. This server combines network port density and processor performance in a compact 2U package. The NSC2U supports a number of processor speeds for the Quad-Core Intel with power efficiency to provide improved performance-per-watt over previous­generation rack-mount servers. The NSC2U also supports a number of processor speeds for the Dual-Core Intel
The NSC2U is an excellent choice for network data applications with large I/O requirements, while providing extended lifecycle support, DC power capabilities, compact form factor, and the ruggedness found on carrier-grade servers. Ideal for network security, it is an excellent choice for intrusion detection/intrusion prevention, VPN/firewall, and unified threat management solutions. In addition, it is a valuable platform for running Telco SoIP, including IMS, IPTV, Video on Demand (VoD), SIP application servers, IP-PBX, and IP-PSTN Gateways. Other network applications well-suited for this platform are enterprise application acceleration and content caching.
More product information is available at the following websites:
NSC2U Product Overview:
http://www.intel.com/design/telecom/products/cbp/ipserver/NSC2U/overview.htm
NSC2U Product Support:
http://www.intel.com/support/telecom/computeboards/nsc2u/
Purpose of this Document:
This document provides details on what parts are available for ordering of the Intel® IP Network Server NSC2U production systems. This includes PID and MM# information for System SKUs, Accessories & Spares, as well as other Intel parts that are supported by the NSC2U product.
Supported third-party components are not covered by this document, and may be found in the Tested Hardware and Operating System List (THOL) for this product.
®
Xeon® 5300 and 5400 series processors, coupling high performance
®
Xeon® 5100 series processors.
3/28/2008 v 2.2 4 of 20

II. Production System SKUs

The NSC2U Production System SKUs that can be ordered are listed below:
Product Identification Code
Description MM#
Min. Order
Qty.
NSCA0201W
NSCD0201W
Intel® IP Network Server NSC2U, Base Model 0 with AC Power Supply
Intel® IP Network Server NSC2U, Base Model 0 with DC Power Supply
889358 1
889357 1
See the NSC2U Base Model 0 Configuration table further down in this section for a list of components included in each base model 0 SKU.
Production SKUs are offered as either an AC or DC version. The Product Identification code, or PID, of all SKUs contains either the letter “A” for AC or “D” for DC as the 4th digit of the PID.
Both Production SKUs are base model 0 SKUs, (no processor, heatsink, memory, hard drive, power cord, operating system, or plug-in adapters are provided). Those components must be ordered separately as Accessories from Intel or from third party vendors listed in the Tested Hardware and Operating System List (THOL).
Power Cords are not included with the Mod 0 system. For AC Power cords, order the NA – North American power cord below. This power cable is RoHS-compliant.
PID MM# Comments
PWRCABLEUS 816324
Note: Ensure that customers have the appropriate technical support and contact before placing their first order.
This AC power cable can be ordered by North America (NA) customers. International customers should procure their specific power cords directly.
3/28/2008 v 2.2 5 of 20
NSC2U Base Model 0 Configuration:
All Production SKUs are base model 0 SKUs (no processor, heatsink, memory, hard drive, power cord, operating system, or plug-in adapters are provided). Those components must be ordered separately as Accessories from Intel or from third party vendors listed in the Tested Hardware and Operating System List (THOL).
The table below lists which components are included in the base model 0 SKUs and which ones must be ordered separately or as optional accessories.
Component Description
AC Mod 0
Configuration
AC power supply (600 W) 1 included ­DC power supply (600 W) - 1 included Filler Panel in 2nd power supply bay 1 included Chassis (bezel, sheet metal, top cover, PCI carrier) 1 included Server Board T5000PAL 1 included Bezel (gray) 1 included PCI Riser FH-FL (two PCI-Express and one PCI-X slots) 1 included PCI Riser LP (two PCI-Express slots) 1 included FB-DIMM slots (memory not included) 8 included Trays for hot-swap 2.5” SAS Hard Disk Drives 6 included Filler Panel in optical device bay 1 included Rear Panel GbE NIC (Cu) ports (via Server Board) 2 included Server Deployment Toolkit (CD) 1 included Quick Start Guide 1 included Power Cable Purchase separately1 SW RAID 0/1/10 Included HW RAID 5 Optional Accessories2 Intel® Z-U130 Value Solid State Drive Optional Accessory2 Mounting kit for Intel® Z-U130 Value Solid State Drive Optional Accessory2 Remote Management Module 2 Optional Accessory2 PCI-X FH-FL Riser (3 PCI-X slots) Optional Accessories2 Ethernet I/O Module (dual Gigabit rear ports) Optional Accessory2 SAS I/O Expansion Module (x4 external rear port) Optional Accessory2 Rack Mount Kits Optional Accessory4 Processor (refer to “Details on Ordering Processors”) Purchase separately5 Heatsink Accessory or purchase separately Memory Purchase separately5 Hard Disk Drive Purchase separately5 Optical Drive Purchase separately5
Accessories for NIC-in-Front Capability3
Quad Port Bypass Adapter (Copper) Optional Accessory3 Quad Port Bypass Adapter (Fiber) Optional Accessory3 Quad NIC-in-Front Mounting Kit (Copper) Optional Accessory3 Quad NIC-in-Front Mounting Kit (Fiber) Optional Accessory3
1
Refer to AC power cord accessory in this section
2
Refer to “Production Spares/Accessories List” in section III
3
Refer to “Quad Port Bypass NIC Capability” in section IV
4
Refer to “Rack Mounting Options” in the Appendix
5
Should be purchased separately (parts not listed in this document)
DC Mod 0
Configuration
3/28/2008 v 2.2 6 of 20
Loading...