Intel 4 Series, P45, G43, P43, G41 Thermal/mechanical Design Manuallines

...
Intel® 4 Series Chipset
Thermal and Mechanical Design Guidelines
September 2008
Document Number: 319972-004
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL’S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
UNLESS OTHERWISE AGREED IN WRITING BY INTEL, THE INTEL PRODUCTS ARE NOT DESIGNED NOR INTENDED FOR ANY APPLICATION IN WHICH THE FAILURE OF THE INTEL PRODUCT COULD CREATE A SITUATION WHERE PERSONAL INJURY OR DEATH MAY OCCUR.
Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities aris ing from future changes to them. The information here is subject to change without notice. Do not finalize a design with th is information.
The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published sp ecifications. Current characterized errata are available on request.
Contact your local Intel sales office or your distributor to obtain the latest specifications and before placin g your product order. This document contains information on products in the design phase of development. All products, platforms, dates, and figures specified are preliminary based on current expectations, and are subject to change
without notice. All dates specified are target dates, are provided for planning purposes only and are subject to change. This document contains information on products in the design phase of development. Do not finalize a design with this
information. Revised information will be published when the product is available. Verify with your local sales office that you have the latest datasheet before finalizing a design.
Code names featured are u sed internally within Intel to identify products that are in development and not yet publicly announced for release. Customers, licensees and other third parties are not authorized by Intel to use code names in advertising, promotion or marketing of any product or services and any such use of Intel’s internal code names is at the sole risk of the user.
Intel, Intel, Pentium, Intel Core, and the Intel logo and the Intel logo are trademarks of Intel Corporation in the U.S. and other countries.
*Other names and brands may be claimed as the property of others. Copyright © 2008, Intel Corporation. All rights reserved.
Thermal and Mechanical Design Guidelines 2
Contents
1 Introduction.....................................................................................................7
1.1 Terminology ..........................................................................................8
1.2 Reference Documents.............................................................................9
2 Product Specifications......................................................................................11
2.1 Package Description..............................................................................11
2.1.1 Non-Grid Array Package Ball Placement......................................11
2.2 Package Loading Specifications...............................................................12
2.3 Thermal Specifications..........................................................................12
2.3.1 Thermal Design Power (TDP) ....................................................13
2.3.1.1 Definition ................................................................13
2.3.2 TDP Prediction Methodology......................................................13
2.3.2.1 Pre-Silicon...............................................................13
2.3.2.2 Post-Silicon..............................................................13
2.3.3 Thermal Specifications.............................................................14
2.3.4 T
2.4 Non-Critical to Function Solder Balls........................................................15
Limit..........................................................................15
CONTROL
3 Thermal Metrology..........................................................................................17
3.1 Case Temperature Measurements...........................................................17
3.1.1 Thermocouple Attach Methodology.............................................17
3.2 Airflow Characterization ........................................................................19
4 Reference Thermal Solution..............................................................................21
4.1 Operating Environment .........................................................................22
4.1.1 ATX Form Factor Operating Environment ....................................23
4.1.2 Balanced Technology Extended (BTX) Form Factor Operating
Environment...........................................................................
4.2 Reference Design Mechanical Envelope....................................................27
4.3 Thermal Solution Assembly....................................................................27
4.4 Environmental Reliability Requirements...................................................29
Appendix A Enabled Suppliers ...........................................................................................31
Appendix B Mechanical Drawings.......................................................................................33
26
3 Thermal and Mechanical Design Guidelines
Figures
Figure 1. (G)MCH Non-Grid Array......................................................................11
Figure 2. Package Height .................................................................................12
Figure 3. Non-Critical to Function Solder Balls.....................................................15
Figure 4. 0° Angle Attach Methodology (top view, not to scale)..............................18
Figure 5. 0° Angle Attach Heatsink Modifications (generic heatsink side and
bottom view shown, not to scale).........................................................
Figure 6. Airflow &Temperature Measurement Locations.......................................19
Figure 7. Cross-Cut Dimension Change of PWSHS Reference Design.......................22
Figure 8. ATX Boundary Conditions....................................................................24
Figure 9. Side View of ATX Boundary Conditions..................................................25
Figure 10. Processor Heatsink Orientation to Provide Airflow to (G)MCH
Heatsink on an ATX Platform..............................................................
Figure 11. Processor Heatsink Orientation to Provide Airflow to (G)MCH
Heatsink on a Balanced Technology Extended (BTX) Platform.................
Figure 12. Design Concept for ATX (G)MCH Heatsink — Installed on Board..............28
Figure 13. Design Concept for Balanced Technology Extended (BTX) (G)MCH
Heatsink Design — Installed on Board.................................................
Figure 14. (G)MCH Package Drawing .................................................................34
Figure 15. (G)MCH Component Keep-Out Restrictions for ATX Platforms .................35
Figure 16. (G)MCH Component Keep-Out Restrictions for Balanced Technology
Extended (BTX) Platforms.................................................................
Figure 17. (G)MCH Reference Heatsink for ATX Platforms – Sheet 1.......................37
Figure 18. (G)MCH Reference Heatsink for ATX Platforms – Sheet 2.......................38
Figure 19. (G)MCH Reference Heatsink for ATX Platforms – Anchor ........................39
Figure 20. (G)MCH Reference Heatsink for ATX Platforms – Ramp Retainer Sheet 1..40 Figure 21. (G)MCH Reference Heatsink for ATX Platforms – Ramp Retainer Sheet 2..41
Figure 22. (G)MCH Reference Heatsink for ATX Platforms – Wire Preload Clip ..........42
Figure 23. (G)MCH Reference Heatsink for Balanced Technology Extended
(BTX) Platforms ...............................................................................
Figure 24. (G)MCH Chipsets Reference Heatsink for Balanced Technology
Extended (BTX) Platforms – Clip.........................................................
18
25 27
28
36
43 44
Tables
Table 1. Package Loading Specifications.............................................................12
Table 2. Thermal Specifications.........................................................................14
Table 3. (G)MCH Heatsink Boundary Condition Summary in ATX Platforms..............23
Table 4. (G)MCH Heatsink Boundary Condition Summary in BTX Platforms..............26
Table 5. ATX Reference Thermal Solution Environmental Reliability Requirements
(Board Level) .....................................................................................
Table 6. Balanced Technology Extended (BTX) Reference Thermal Solution
Environmental Reliability Requirements (System Level)............................
Table 7. ATX Intel Reference Heatsink Enabled Suppliers for (G)MCH .....................31
Table 8. BTX Intel Reference Heatsink Enabled Suppliers for (G)MCH .....................31
Table 9. Supplier Contact Information................................................................32
Thermal and Mechanical Design Guidelines 4
29 30
Revision History
Revision
Number
-001 Initial Release June 2008
-002 Minor edits and formatting throughout. June 2008
-003 Added Intel 82G41 GMCH September 2008
-004 Added Intel 82Q43 GMCH and 82Q45 GMCH September 2008
Description Date
§
5 Thermal and Mechanical Design Guidelines
Thermal and Mechanical Design Guidelines 6
Introduction

1 Introduction

As the complexity of computer systems increases, so do power dissipation requirements. The additional power of next generation systems must be properly dissipated. Heat can be dissipated using improved system cooling, selective use of ducting, and/or passive heatsinks.
The objective of thermal management is to ensure that the temperatures of all components in a system are maintained within functional limits. The functional temperature limit is the range within which the electrical circuits can be expected to meet specified performance requirements. Operation outside the functional limit can degrade system performance, cause logic errors, or cause component and/or system damage. Temperatures exceeding the maximum operating limits may result in irreversible changes in the operating characteristics of the component.
This document is for the following devices:
®
Intel
Intel
Intel
Intel
P45 Chipset MCH (82P45 MCH)
®
P43 Chipset MCH (82P43 MCH)
®
G45 Chipset GMCH (82G45 GMCH)
®
G43 Chipset GMCH (82G43 GMCH)
Intel® G41 Chipset GMCH (82G41 GMCH)
Intel® Q45 Chipset GMCH (82Q45 GMCH)
Intel® Q43 Chipset GMCH (82Q43 GMCH)
This document presents the conditions and requirements to properly design a cooling solution for systems that implement the (G)MCH. Properly designed solutions provide adequate cooling to maintain the (G)MCH case temperature at or below thermal specifications. This is accomplished by providing a low local-ambient temperature, ensuring adequate local airflow, and minimizing the case to local-ambient thermal resistance. By maintaining the (G)MCH case temperature at or below those recommended in this document, a system designer can ensure the proper functionality, performance, and reliability of this component.
Note: Unless otherwise specified the information in this document applies to all
configurations of Intel
®
P45, P43, Q45, Q43, G45, G43, and G41 Chipsets. The Intel® Q45, Q43, G45, G43, and G41 Chipsets are available with integrated graphics and associated SDVO and digital display ports. In this document the integrated graphics version is referred to as GMCH. In addition a version will be offered using discrete graphics and is referred to as the MCH. The term (G)MCH will be used to when referring to all configurations.
Note: In this document the Intel P45, P43, Q45, Q43, G45, and G43 Chipsets refer to the
combination of the (G)MCH and the Intel
®
ICH10. For ICH10 thermal details, refer to the Intel® I/O Controller Hub 10 (ICH10) Thermal Design Guidelines. The Intel G41 Chipset refers to the combination of the GMCH and Intel ICH7. For ICH7 details, refer to the Intel® I/O Controller Hub 7 (ICH7) Thermal Design Guidelines.
7 Thermal and Mechanical Design Guidelines

1.1 Terminology

Term Description
FC-BGA Flip Chip Ball Grid Array. A package type defined by a plastic substrate where a
die is mounted using an underfill C4 (Controlled Collapse Chip Connection) attach style. The primary electrical interface is an array of solder balls attached to the substrate opposite the die. Note that the device arrives at the customer with solder balls attached.
Intel® ICH7 Intel® I/O Controller Hub 7. The chipset component that contains the primary
PCI interface, LPC interface, USB2, SATA, and/or other legacy functions.
Intel® ICH10 Intel® I/O Controller Hub 10. The chipset component that contains the primary
PCI interface, LPC interface, HDA interface, USB2, SATA, and/or other legacy functions.
GMCH Graphic Memory Controller Hub. The chipset component that contains the
processor and memory interface and integrated graphics core.
TA The local ambient air temperature at the component of interest. The ambient
temperature should be measured just upstream of airflow for a passive heatsink or at the fan inlet for an active heatsink.
Introduction
TC The case temperature of the (G)MCH component. The measurement is made at
the geometric center of the die.
T
The maximum value of T
C-MAX
T
The minimum valued of T
C-MIN
TDP Thermal Design Power is specified as the maximum sustainable power to be
dissipated by the (G)MCH. This is based on extrapolations in both hardware and software technology. Thermal solutions should be designed to TDP.
TIM Thermal Interface Material: thermally conductive material installed between two
surfaces to improve heat transfer and reduce interface contact resistance.
Ψ
Case-to-ambient thermal solution characterization parameter (Psi). A measure
CA
of thermal solution performance using total package power. Defined as (T
) / Total Package Power. Heat source size should always be specified for Ψ
T
A
measurements.
.
C
.
C
C
Thermal and Mechanical Design Guidelines 8
Introduction

1.2 Reference Documents

Document Location
Intel® 4 Series Chipset Family Datasheet http://www.intel.com/assets/p
Intel® I/O Controller Hub 7 (ICH7) Thermal Design Guidelines http://www.intel.com/assets/p
Intel® I/O Controller Hub 10 (ICH10) Thermal Design Guidelines http://www.intel.com/assets/p
df/datasheet/319970.pdf
df/designguide/307015.pdf
df/designguide/319975.pdf
Intel® Core™2 Duo Processor E8000Δ and E7000Δ Series and Intel® Pentium Mechanical Design Guidelines
Intel® Core™2 Extreme Quad-Core Processor and Intel® Core™2 Quad Processor Thermal and Mechanical Design Guidelines
Balanced Technology Extended (BTX) Interface Specification http://www.formfactors.org
Various System Thermal and Mechanical Design Suggestions http://www.formfactors.org
Various Chassis Thermal and Mechanical Design Suggestions http://www.formfactors.org
®
Dual-Core Processor E5000Δ Series Thermal and
http://www.intel.comdesign/pro cessor/designex/318734.pdf
http://www.intel.com/ design/processor/designex/
315594.htm
§
9 Thermal and Mechanical Design Guidelines
Introduction
Thermal and Mechanical Design Guidelines 10
Product Specifications

2 Product Specifications

2.1 Package Description

The (G)MCH is available in a 34 mm [1.34 in] x 34 mm [1.34 in] Flip Chip Ball Grid Array (FC-BGA) package with 1254 solder balls. The die size is currently 10.80 mm [0.425 in] x 9.06 mm [0.357 in] and is subject to change. A mechanical drawing of the package is shown in

2.1.1 Non-Grid Array Package Ball Placement

The (G)MCH package utilizes a “balls anywhere” concept. Minimum ball pitch is
0.7 mm [0.028 in], but ball ordering does not follow a 0.7 mm grid. Board designers should ensure correct ball placement when designing for the non-grid array pattern. For exact ball locations relative to the package, refer to the Intel Family Datasheet.
Figure 1. (G)MCH Non-Grid Array
Figure 14, Appendix B.
®
4 Series Chipset
34 x 34mm Substrate [1.34 x 1.34 in]
Non-standard grid ball pattern. Minimum Pitch 0.7mm [0.028 in]
11 Thermal and Mechanical Design Guidelines

2.2 Package Loading Specifications

Table 1 provides static load specifications for the package. This mechanical maximum load limit should not be exceeded during heatsink assembly, shipping conditions, or standard use conditions. Also, any mechanical system or component testing should not exceed the maximum limit. The package substrate should not be used as a mechanical reference or load-bearing surface for the thermal and mechanical solution.
Table 1. Package Loading Specifications
Parameter Maximum Notes
Static
NOTES:
1. These specifications apply to uniform compressive loading in a direction normal to the package.
2. This is the maximum force that can be applied by a heatsink retention clip. The clip must also provide the minimum specified load on the package.
3. These specifications are based on limited testing for design characterization. Lo ading limits are for the package only.
To ensure the package static load limit is not exceeded, the designer should understand the post reflow package height. The following figure shows the nominal post-reflow package height assumed for calculation of a heatsink clip preload of the reference design. Refer to the package drawing in analysis.
15 lbf
1,2,3
Appendix B to perform a detailed
Product Specifications
Figure 2. Package Height

2.3 Thermal Specifications

To ensure proper operation and reliability of the (G)MCH, the case temperature must be at or below the maximum value specified in thermal enhancements are required to dissipate the heat generated and maintain the (G)MCH within specifications. Chapter 3 provides the thermal metrology guidelines for case temperature measurements.
Table 2. System and component level
Thermal and Mechanical Design Guidelines 12
Product Specifications

2.3.1 Thermal Design Power (TDP)

2.3.1.1 Definition
Thermal design power (TDP) is the estimated power dissipation of the (G)MCH based on normal operating conditions including V case power intensive applications. This value is based on expected worst-case data traffic patterns and usage of the chipset and does not represent a specific software application. TDP attempts to account for expected increases in power due to variation in (G)MCH current consumption due to silicon process variation, processor speed, DRAM capacitive bus loading and temperature. However, since these variations are subject to change, there is no assurance that all applications will not exceed the TDP value.
The system designer must design a thermal solution for the (G)MCH such that it maintains T
specification is a requirement for a sustained power level equal to TDP, and that
T
C-MAX
below T
C
the case temperature must be maintained at temperatures less than T operating at power levels less than TDP. This temperature compliance is to ensure component reliability. The TDP value can be used for thermal design if the thermal protection mechanisms are enabled. The (G)MCH incorporate a hardware-based fail­safe mechanism to keep the product temperature in spec in the event of unusually strenuous usage above the TDP power.
for a sustained power level equal to TDP. Note that the
C-MAX
and T
CC
while executing real worst-
C-MAX
C-MAX
when

2.3.2 TDP Prediction Methodology

2.3.2.1 Pre-Silicon
To determine TDP for pre-silicon products in development, it is necessary to make estimates based on analytical models. These models rely on knowledge of the past (G)MCH power dissipation behavior along with knowledge of planned architectural and process changes that may affect TDP. Knowledge of applications available today and their ability to stress various aspects of the (G)MCH is also included in the model. The projection for TDP assumes (G)MCH operation at T accounts for normal manufacturing process variation.
2.3.2.2 Post-Silicon
Once the product silicon is available, post-silicon validation is performed to assess the validity of pre-silicon projections. Testing is performed on both commercially available and synthetic high power applications and power data is compared to pre-silicon estimates. Post-silicon validation may result in a small adjustment to pre-silicon TDP estimates.
. The TDP estimate also
C-MAX
13 Thermal and Mechanical Design Guidelines

2.3.3 Thermal Specifications

The data in Table 2 is based on post-silicon power measurements for the (G)MCH. The TDP values are based on system configuration with two (2) DIMMs per channel, DDR3 (or DDR2) and the FSB operating at the top speed allowed by the chipset with a processor operating at that system bus speed. Intel recommends designing the (G)MCH thermal solution to the highest system bus speed and memory frequency for maximum flexibility and reuse. The (G)MCH packages have poor heat transfer capability into the board and have minimal thermal capability without thermal solutions. Intel requires that system designers plan for an attached heatsink when using the (G)MCH.
Table 2. Thermal Specifications
Product Specifications
Component Mem
Intel® G45
Type
DDR3 1333
Chipset Intel® G43
DDR3 1333
Chipset Intel® G41
DDR3 1333
Chipset
Intel® Q45 /
DDR3 1333
Q43 Chipset Intel® Q45 /
DDR2 1333
Q43 Chipset Intel® Q43
DDR3 1333
Chipset
Intel® P45
DDR3 1333
Chipset Intel® P43
DDR3 1333
Chipset
NOTES:
1. Thermal specifications assume an attached heatsink is present.
2. Max Idle power is the worst case idle power in the system booted to Windows* with no
3. Intel
4. When an external graphic card is installed in a system with the Intel
5. The Idle and TDP numbers are assuming Internal Graphics is disabled on the Intel Q43
6. Idle data is measured on Intel P45, P43 Chipset when an external graphics card is
Sys Bus
Speed
MT/s
MT/s
MT/s
MT/s
MT/s
MT/s
MT/s
MT/s
background applications running.
®
P45, P43, G45, G43, Q45, and Q43 Chipset TDP is measured with DDR3 (or DDR2) with 2 channels, 2 DIMMs per channel and Max Idle power is measured with DDR3 (or DDR2) with 2 channels, 1 DIMM per channel. Intel Idle power are measured with DDR3 with 2 channels, 1 DIMM per channel.
Mem
Freq
1333 MT/s
1067 MT/s
1067 MT/s
1067
MT/s
800
MT/s
1067
MT/s
1333 MT/s
1067 MT/s
Max Idle
Power
(C1/C2
Enabled)
Max Idle
Power
(C3/C4
Enabled)
TDP T
C-MIN
T
C-MAX
Notes
9 W 7.7 W 24 W 0 °C 103°C 1,2,3,4
9 W 7.7 W 24 W 0 °C 103 °C 1,2,3,4
11.5 W N/A 25 W 0 °C 102 °C 1,2,3
6W 4.7 W 17 W 0 °C 105 °C 1,2,3
6W 4.7 W 17 W 0 °C 105 °C 1,2,3
5W 3.8 W 13 W 0 °C 105 °C 1,2,3,5
9 W 7.5 W 22 W 0 °C 103 °C 1,2,3,6
9 W 7.5 W 22 W 0 °C 103 °C 1,2,3,6
®
G41 Chipset TDP and Max
®
G45, G43 Chipsets, the TDP for these parts will drop to approximately 22 W. The GMCH will detect the presence of the graphics card and disable the on-board graphics resulting in the lower TDP for these components.
Chipset. installed in a system wherein this card must support L0s /L1 ASPM.
Thermal and Mechanical Design Guidelines 14
Loading...
+ 30 hidden pages