SERVICE MANUAL / PARTS LIST
ALL ELECTRIC MODELS and VOLTAGES
1055 Mendell Davis Drive • Jackson MS 39272
888-994-7636 • 601-372-3903 • Fax 888-864-7636
unifiedbrands.net
PART NUMBER 158632 REV B (11/11)
TABLE OF CONTENTS
&21752/ 6,'( &20321(176
(/(0(176 $1' 3/80%,1* &20321(176
7528%/(6+227,1* *8,'(
:,5,1* ',$*5$0
5(3/$&(0(17 3$576
(/(0(17 ),(/' 5(3/$&(0(17 ,16758&7,216
7+(5020(7(5 5(3/$&(0(17
(/(0(17 $03 5($',1*
2
SM-XS
NT NT 1064
NT
NT
NT
NT
NT
NT
NT
NT
NT
NT
NT
|
NT |
NT |
|
NT |
NT |
NT 1785 |
|
|
|
|
NT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NT1064
NT
NT1785
NT
NT
NT
NT
NT
NT
NT
NT
NT
NT
NT
NT
NT
NT
NT
NT
REFER TO WIRING DIAGRAM FOR ADDITIONAL INFORMATION
3
SM-XS
NT1091
NT1128
NT1009 |
|
NT1011 |
|
NT1012 |
|
NT1013 |
|
NT1045 |
|
NT1046 |
|
NT1269 |
|
NT1270 |
|
NT1091 |
|
NT1797 |
Heater, 208V, 14.4kW (new ver.) |
NT1798 |
Heater, 240V, 14.4kW (new ver.) |
NT1128 |
|
NT1079
NT1080
NT1100
NT1018
REFER TO WIRING DIAGRAM FOR ADDITIONAL INFORMATION
4
SM-XS
WARNING
TO PREVENT ELECTRICAL SHOCK DISCONNECT
AC INCOMING POWER BEFORE SERVICING.
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL ONLY.
SYMPTOM |
POSSIBLE CAUSE |
|
|
|
|
No Lights When |
Facility Main Breaker, Unit Ran DryNo Water In Chamber, |
|
F1/F2 Fuse, Hi-Limit (OT-1), MC, CR-1 or N.O. Contact- |
||
ON Is Pressed |
||
ON Pushbutton |
||
|
||
Unit Turns ON When |
Auxilary Contact on MC, N.C. ContactOFF Pushbutton |
|
"ON" PushedTurns |
||
OFF When Released |
|
|
"Add Water" Light On |
Not Enough Water In Chamber, Build-Up (Lime) On |
|
Chamber Bottom, OT-2/OT-3 or AWR. |
||
|
||
Unit Won't Heat Up: |
|
|
1) w/ Steam Out Exhaust |
PS-1, SSR-1/SSR-2, CR-2 Not Working In Cook Mode |
|
2) w/o Steam Out Exhaust |
Steam Orifice Is Blocked |
|
Heat Stays On |
Normal When Door Open, PS-1, SSR-1/SSR-2 |
|
(Light Stays On) |
(If Door Is Leaking SteamAdjust First) |
|
Heat Stays On |
SSR-1/SSR-2 |
|
(Light Cycles) |
||
|
||
|
|
OPERATING SUMMARY
When the timer is at the HOLD position, heat is controlled by the HOLD Thermostat. When the timer is at any other position, heat is directly controlled by PS-1 (pressure switch). Note: Both COOK and HOLD Mode heat outputs are directed through PS-1.
It is normal for the Heat Indicator Light to cycle ON and OFF.
The Convection Fan (CFM) is only on during the cooking cycle.
REFER TO WIRING DIAGRAM FOR ADDITIONAL INFORMATION
5
SM-XS
TROUBLESHOOTING GUIDE
6
SM-XS
|
L1 |
L2 |
L3 |
|
|
|
|
|
|
|
MC |
GND |
IMPORTANT |
|
|
|
|
|
|
|
|
||
|
|
|
|
|
DO NOT CONNECT POWER |
|
|
|
|
|
|
|
TO L3 ON SINGLE PHASE UNITS |
|
|
1 |
|
|
|
THIS LEG REMOVED ON SINGLE PHASE UNITS |
|||
|
|
|
|
|
|
|
|
2 |
|
|
|
|
|
|
|
3 |
|
|
|
|
|
|
|
4 |
480VAC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
|
|
|
|
WHITE |
|
|
240VAC |
|
|
|
|
|
||
|
|
|
|
|
|
||
6 |
XFMR T1 - (480 UNIT ONLY) |
|
|
|
MC |
||
RED |
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
ON |
PB1 |
BLK |
OT1 |
OT4 |
BRN |
|
7 |
|
|
CR1 |
||||
|
|
|
|
|
|
||
|
OFF |
PB2 |
MC |
|
USED ON 14.4kW |
|
|
8 |
YEL |
|
|
|
|||
|
|
|
|
UNITS ONLY |
|
|
|
|
|
|
|
CR1 |
|
|
|
|
FUSES |
|
|
|
CR1 |
|
9 |
|
|
|
|
|
|
|
OR |
|
(FRN-R5) |
GRAY |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10 |
|
|
|
|
|
|
|
RED |
|
FB |
|
|
LT BLUE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
OT2 |
|
|
F1 |
F2 |
|
|
|
|
|
|
11 |
|
|
|
|
GRAY |
OT3 |
|
BROWN |
|
|
|
AWR |
|||
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
AWR |
|
|
|
NOT USED ON 14.4kW |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
RED |
|
|
|
|
|||
12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
PL1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
AWR |
|
|
|
|
|
|
|
|
|
|
|
|
|
13 |
|
|
|
|
|
|
|
L1 |
|
L2 |
|
|
|
|
BZ1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
CONNECT |
|
|
|
|
|
|
|
|
|
H |
OR |
|
|
|
|
|
OPTIONAL |
|
|
|
|
|
|
|
|
|
|
|
|||
TO F1 FOR |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
AUTO-FILL |
|
|
|
|
|
|
|
YEL |
|
|
|
|
||
AUTO-FILL |
|
|
|
|
|
|
|
L |
|
HIGH |
|
|
|||
|
CONTROL |
|
|
|
|
|
|
|
|
|
|
||||
OPTION |
|
|
|
|
|
G |
|
|
|
|
PROBE |
|
|
||
|
CIRCUITRY |
|
|
GND |
|
|
|
|
|
|
|||||
|
|
|
|
|
NC |
LOW |
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
AUTO-FILL |
COM |
PROBE |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
LEVEL |
NO |
GRAY |
|
|
WHITE |
||
14 |
|
|
|
|
|
|
|
CONTROL |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
||||||
|
VIOLET |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
SOL1 |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
15 |
VIOLET |
|
|
1 |
2 |
|
|
N |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
|
|
|
|
|
|
|
|
16 |
|
|
|
|
|
|
|
|
|
|
|
|
|
PL2 |
|
17 |
|
|
TM |
|
|
|
4 |
|
|
GRAY |
|
|
|
CR2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
TB2 |
DS1 |
|
TB2 |
|
|
18 |
|
|
|
|
|
|
|
|
|
BLK |
BLK |
PINK |
CFM |
||
|
|
|
TIMER |
|
|
5 |
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
19 |
|
|
|
|
|
|
|
|
|
YEL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BZ2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CR2 |
|
|
|
|
|
PS1 |
|
|
|
|
|
|
20 |
|
|
|
|
|
YEL |
|
|
OR |
|
PL3 |
||||
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
21 |
|
CR2 |
|
|
|
|
|
|
CR2 |
|
|
|
|
|
R1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
THERMOSTAT |
|
|
|
|
|
|
|
|
SSR1 |
|||
22 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
3 |
4 |
5 |
6 |
7 |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
+ |
|
- |
|
|
|
|
|
|
|
23 |
|
BLK |
|
|
|
YEL |
RED |
|
GRAY |
|
|
|
|
|
SSR2 |
|
|
|
|
|
THREE PHASE |
|
|
||||||||
|
|
|
|
|
T.C. |
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
UNITS ONLY |
|
|
|||
|
|
|
|
|
|
|
|
“K” |
|
|
|
R2 |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
24 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
25 |
|
PL4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
SM-XS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
WARNING |
|
REFER SERVICING TO QUALIFIED |
|
PERSONNEL ONLY. DISCONNECT AC |
|
INCOMING POWER BEFORE |
SSR2 |
SERVICING. |
SSR1
TO TB1
MASTER
CONTACTOR HEATING ELEMENT CONFIGURATION SELECT MODEL BELOW
CONTROL
RELAY 1
TB1
|
1L1 |
1L2 |
1L3 |
ADD WATER |
MODELS: |
XS208-8-3, XS240-8-3 |
|
RELAY |
XS208-12-3, XS240-12-3 |
||
|
|
|
XS480-12-3 |
ADD WATER |
|
|
< S/N 5500 |
LAMP |
XS208-14-3, XS240-14-3 |
||
ADD WATER |
|
|
|
BUZZER |
|
|
TB1 |
|
|
|
|
CONNECT |
|
|
|
TO F2 FOR |
|
|
|
AUTO-FILL |
|
|
|
OPTION |
|
|
|
IMPORTANT
STD. UNIT SHOWN
CONNECTED.
FOR UNIT WITH |
1L1,1L2,1L3 |
1L1,1L2,1L3 |
|||
AUTO-FILL OPTION, |
MODELS: |
> SN 5500 |
|||
THE “ADD WATER” |
XS208-14-3, XS240-14-3 |
||||
INDICATING |
|
|
|
|
|
CIRCUITRY (10-13) |
|
|
|
|
|
IS REMOVED. |
|
|
|
TB1 |
|
|
|
|
|
||
COOK MODE |
|
|
|
|
|
LAMP |
|
|
|
|
|
CONTROL |
|
|
|
|
|
RELAY 2 |
|
|
|
|
|
CONVECTION |
|
|
|
|
|
FAN MOTOR |
1L1 |
1L2 |
1L3 |
||
CYCLE END |
|||||
MODELS: XS208-6-1 |
|||||
BUZZER |
|||||
|
|
|
XS240-6-1 |
||
HEAT LAMP |
|
|
|
TB1 |
|
|
|
|
|
15K , 5W, 250WV |
|
|
|
HEATER RELAY 1 |
|
|
|
|
1L1 |
1L2 |
1L3 |
HEATER RELAY 2 |
MODELS: XS208-8-1 |
||
|
|
XS240-8-1 |
|
15K , 5W, 250WV |
|
|
|
HOLD MODE |
WIRING DIAGRAM WD-2 7 |
||
LAMP |
REPLACEMENT PARTS LIST
Part No. |
Description |
Cost |
NT1009 |
Heater, 208V, 12kW |
$177.58 |
NT1011 |
Heater, 240V, 12kW |
$177.58 |
NT1012 |
Heater, 208V, 6.24kW |
$173.50 |
NT1013 |
Heater, 240V, 6.24kW |
$177.58 |
NT1045 |
Heater, 208V, 8.5kW |
$174.88 |
NT1046 |
Heater, 240V, 8.5kW |
$177.58 |
NT1269 |
Heater, 208V, 14.4kW |
$177.58 |
NT1270 |
Heater, 240V, 14.4kW |
$23.86 |
NT1797 |
Heater, 208V, 14.4kW (new ver.) |
$40.22 |
NT1798 |
Heater, 240V, 14.4kW (new ver.) |
$19.42 |
NT1063 |
Buzzer, Continuous, Low Water/End of Cycle |
$61.80 |
NT1067 |
DP Contactor, Main Power |
$12.02 |
NT1070 |
Relay, 220V, Control |
$90.48 |
NT1072 |
Fan, Convection (Includes Blade Assy.) |
$6.30 |
NT1073 |
Fuse, 5 Amp |
$8.82 |
NT1075 |
Thermostat, Hold 100-212 Degrees |
$6.66 |
NT1076 |
Lamp, Red |
$9.55 |
NT1077 |
Lamp, Blue |
$9.55 |
NT1078 |
Lamp, Amber |
$36.09 |
NT1079 |
Thermostat, Bi-Metal, 325°F |
$55.60 |
NT1080 |
Thermostat, Bi-Metal 410°F |
$10.87 |
NT1083 |
Plug, Angle 250V 3PH |
$10.87 |
NT1085 |
Timer, 60 Minute |
$6.89 |
NT1086 |
Operator, Switch, PB, On |
$14.26 |
NT1087 |
Operator, Switch, PB, Off |
$14.26 |
NT1088 |
Mounting Latch, On/Off Switches |
$32.73 |
NT1089 |
Contact, NC, Off Switch |
$41.38 |
NT1090 |
Contact, NO, On Switch |
$9.00 |
NT1091 |
Switch, Pressure, 1/8" NPT |
$53.10 |
NT1092 |
Solid State Relay, 75A, AC Input |
$13.88 |
NT1093 |
Terminal block, 3-pos. |
$22.72 |
NT1098 |
Thermometer, Analog 100-220 Degrees |
$38.76 |
NT1100 |
Switch, Reed, Door Switch |
$37.92 |
NT1155 |
Aux. Contact, DP Contactor |
$20.77 |
NT1018 |
Door Seal |
$55.45 |
NT1115 |
Hinge, one pair |
$16.50 |
NT1119 |
Shaft Seal, 6mm |
$16.39 |
NT1144 |
Magnetic Door Latch |
$5.28 |
NT1175 |
Stand Caster, 5” Locking |
$11.14 |
NT1176 |
Stand Caster, 5” Non-locking |
$18.12 |
NT1178 |
Knob |
$14.13 |
NT1335 |
Nutplate |
$98.72 |
NT1127 |
Drain Valve |
$64.77 |
NT1064 |
Buzzer, Continuous, Low Water/End of Cycle |
$81.52 |
NT1022 |
Shell/Top |
$298.82 |
NT1023 |
Right Side, Shell |
$256.00 |
NT1151 |
Left Side Shell, Louvered |
$16.89 |
NT1021 |
Door Assembly |
$33.58 |
NT1137 |
Auto Fill Control Board with Probes |
$19.20 |
NT1028 |
Control Panel Overlay |
$10.20 |
NT1502 |
Check Valve Assembly |
$20.60 |
NT1116 |
Heat Sink |
$46.00 |
NT1132 |
3/4 Inch Hose |
$4.95 |
NT1001 |
Galvanized Bottom Plate |
$4.03 |
NT1003 |
Heater Plate, Aluminum |
$50.80 |
NT1120 |
Insulation, Chamber bottom |
$11.77 |
NT1135 |
Lens, Thermometer |
$24.12 |
NT1537 |
Inner Door Panel Assembly |
$19.04 |
NT1096 |
Thermocouple |
$43.72 |
NT1037 |
Shelf Bracket, Stand |
$12.63 |
NT1027 |
Pan BracketSteamer Bottom |
$.45 |
NT1035 |
Wire from Assembly, LH side |
$.55 |
NT1117 |
Steamer Foot, flanged |
$2.82 |
NT1104 |
Screw, 10-24 x 1/2 SS |
$5.10 |
NT1217 |
Nutsert |
$7.32 |
NT1158 |
Radial Lead Varistor |
|
NT1202 |
Brass Reducer, 1/2 x 1/8 |
|
NT1122 |
Insulation, Door |
|
8
SM-XS
9
SM-XS
10