Integra Fireboy Plus 144000 Operating Instructions Manual

FIREBOY plus Operating instructions
144950_V07
Declaration of conformity
INTEGRA Biosciences AG –
7205 Zizers, Switzerland
declares on its own responsibility that the device
Zizers, November 4, 2016
Description Model
FIREBOY plus 144000
EU Directives (DoW: Date of Withdrawal) Before DoW DoW After DoW
Low Voltage Equipment 2006/95/EC 20.04.2016 2014/35/EU
Electromagnetic Compatibility 2004/108/EC 20.04.2016 2014/30/EU
Restriction of Hazardous Substances 2011/65/EU
Waste Electrical and Electronic Equipment 2012/19/EU
Battery Directive 2006/66/EC
EU Regulations
Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)
1907/2006
Capacity Labelling of Portable Secondary Batteries 1103/2010
Ecodesign - Power supplies 278/2009
Standards for EU
Safety requirements for electrical equipment for measurement, control and laboratory use - General requirements.
EN 61010-1: 2010
Electrical equipment for measurement, control and laboratory use ­EMC requirements.
EN 61326-1: 2013
Standards for Canada and USA
Safety requirements for electrical equipment for measurement, control and laboratory use - General requirements.
CAN/CSA-C22.2
No. 61010-1
Safety requirements for electrical equipment for measurement, control and laboratory use - General requirements.
UL 61010-1
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Part 15 of the
FCC Rules
Class A
Elmar Morscher CEO
Thomas Neher Quality Manager
FIREBOY plus – Operating instructions V07
www.integra-biosciences.com 3
English
Table of contents
Chapter 1 Introduction
1.1 Explanation of symbols ....................................................................5
1.2 Appropriate use ................................................................................6
1.3 Safety features of the FIREBOY plus...............................................6
1.4 Safety notes .....................................................................................7
Chapter 2 Description of the device
2.1 Scope of delivery..............................................................................9
2.2 Overview FIREBOY plus ..................................................................9
Chapter 3 Installation
3.1 Connecting FIREBOY plus to the electricity supply .......................11
3.2 Operating FIREBOY plus with optional battery ..............................11
3.3 Connecting FIREBOY plus to the gas supply.................................12
3.4 Connecting the foot or benchtop switch .........................................15
3.5 Removing and adding the burner head ..........................................15
3.6 Long burner head ...........................................................................15
Chapter 4 Operation
4.1 Switching FIREBOY plus on and off...............................................16
4.2 Overview of menu functions ...........................................................16
4.3 F
OOT SWITCH operating mode.........................................................16
4.4 B
UTTON operating mode .................................................................17
4.5 SENSOR operating mode.................................................................17
4.6 Adjusting the system parameters ...................................................18
4.7 Working with liquids........................................................................18
4.8 Troubleshooting..............................................................................19
Chapter 5 Maintenance
5.1 Cleaning and servicing ...................................................................21
5.2 Decontamination ............................................................................21
5.3 Disposal..........................................................................................22
Chapter 6 Technical data
6.1 Specifications .................................................................................23
Chapter 7 Accessories
7.1 Accessories ....................................................................................24
FIREBOY plus - Operating instructions V07
4 INTEGRA Biosciences AG
English
Imprint
© 2017 INTEGRA Biosciences AG
All rights relating to this documentation reserved. INTEGRA Biosciences AG especially reserves the rights of duplication, processing, translation and display format. Any reproduction of parts or the entire documentation, or storage thereof on electronic media, or processing or dissemination thereof, require the prior written consent of INTEGRA Biosciences AG.
These operating instructions have the part number 144950; the version is V07. They apply for firmware Version 1.n.
Manufacturer
INTEGRA Biosciences AG INTEGRA Biosciences Corp.
CH-7205 Zizers, Switzerland Hudson, NH 03051, USA T +41 81 286 95 30 T +1 603 578 5800 F +41 81 286 95 33 F +1 603 577 5529 info@integra-biosciences.com www.integra-biosciences.com
Customer service
Please contact your local INTEGRA Biosciences AG representative. You can find the name and address at www.integra-biosciences.com.
Further information and other languages are available on www.integra-biosciences.com or on request (info@integra-biosciences.com).
FIREBOY plus - Operating instructions V07 Introduction
www.integra-biosciences.com 5
English
1 Introduction
These operating instructions contain all information required for the commissioning, operation, and maintenance of the mobile safety Bunsen burner FIREBOY plus.
1.1 Explanation of symbols
1.1.1 Hazard warnings in these operating instructions
These operating instructions specifically advise of residual risks with the following symbols:
W
ARNING
This safety symbol advises of hazards that could result in injury or death. It also indicates hazards for machinery, materials, and the environment. It is essential that you follow the relevant precautions.
C
AUTION
This symbol cautions about potential material damage or data loss in a microprocessor controller. Follow the instructions.
N
OTE
This symbol identifies important notes regarding the correct operation of the device and labor-saving features.
1.1.2 Hazard warnings on the device
A
TTENTION HOT
Risk of burns from the flame.
FIREBOY plus - Operating instructions V07 Introduction
6 INTEGRA Biosciences AG
English
1.1.3 Hazard warnings and caution notes on the LCD display
The following symbols are displayed on the left in the LCD display (see “LCD display” on page 9
):
C
AUTION IN THE "SENSOR" MODE
Flame ignites automatically if object, e.g. hand, comes close to the sensor.
A
TTENTION HOT
Risk of burns from the device still being hot.
BATTERY EMPTY (OPTIONAL)
The symbol of the battery is displayed if no power supply is connected. A flashing symbol indicates that the battery is almost empty and must be recharged.
1.2 Appropriate use
The FIREBOY plus is an automatic safety Bunsen burner for heating or flame­sterilizing suitable laboratory materials. For continuous operation over an extended period of time, the optionally available long burner head (see “7.1 Accessories” on page 24) must be used.
If the FIREBOY plus is used in a manner not specified by INTEGRA Biosciences, the protection provided by the FIREBOY plus may be impaired.
FIREBOY plus may not be altered in design or in any of its safety aspects. If alterations are made, INTEGRA Biosciences will be relieved from all liability for any resulting damage.
1.3 Safety features of the FIREBOY plus
The FIREBOY plus is equipped with the following safety devices:
• If the flame has not ignited after about 3 seconds, the flame monitor closes off the gas valve.
• If the flame is inadvertently extinguished, an attempt will be made to reignite it. If this is not successful, a message is displayed.
• The burner chamber and the valve housing are monitored by a temperature sensor. If the temperature exceeds the safety level, the gas valve is automatically closed off.
FIREBOY plus - Operating instructions V07 Introduction
www.integra-biosciences.com 7
English
1.4 Safety notes
1.4.1 Operation of the FIREBOY plus
The FIREBOY plus corresponds to state of the art and recognized safety
regulations and is safe to operate. The FIREBOY plus may be operated only in flawless condition while observing these operating instructions.
The device may be associated with residual risks if it is used or operated improperly by untrained personnel.
Any person charged with the operation of the FIREBOY plus must have read and understood these operating instructions, and particularly, the safety notes, or must have been instructed by the supervisors so that safe operation of the device is guaranteed.
Regardless of the listed safety notes, additionally applicable regulations and guidelines of the trade associations, the health authorities, and the trade supervisory office, e. g. GLP, GMP, FDA, must be observed.
Please visit our website www.integra-biosciences.com
on a regular basis for up to date information regarding REACH classified chemicals contained in our products.
1.4.2 General safety notes
• Do not carry out any conversions and alterations on the device.
• Defective parts may only be replaced with original INTEGRA Biosciences spare parts.
• Do not open the FIREBOY plus. Repairs may only be performed by INTEGRA Biosciences or an authorized after-sales service member.
• The device may be operated only under constant supervision.
• Always wear protective goggles when working with the FIREBOY plus.
• Work only in well ventilated areas.
• Do not use the FIREBOY plus near flammable material or in explosive areas.
• Use only approved and tested safety gas tubing with threaded or hose connectors and inspect the device regularly for damage.
• Firmly tighten all gas connections and verify gas tightness using test equipment.
• Never remove the gas cartridge adapter while it is connected to the gas cartridge.
• Use only original INTEGRA Biosciences power supply pack or original INTEGRA Biosciences rechargeable batteries.
• Switch off the device before removing or inserting the optional rechargeable battery.
• Observe the hazard warnings on the device.
FIREBOY plus - Operating instructions V07 Introduction
8 INTEGRA Biosciences AG
English
The gas supply must be closed off when:
• the device is being transported or installed
• the gas cartridge is being changed
• extended breaks are taken and after the work has been completed
• cleaning and repair work is being performed
• the rechargeable battery or adapter is being replaced
1.4.3 Battery (optional)
• Old NiMH batteries may cause a safety risk. We recommend to replace the battery after 5 years of use. Also replace the battery if the charging intervals are unusually short or if the charging takes much longer than usual (13 hours or more). These are indicators that the battery has reached the end of its life-cycle.
• NiMH technology bears the risk of cell rupture if the battery was damaged. Do not expose the battery to heat (> 60°C) and avoid mechanical stress.
• To extend the battery life-cycle, it is recommended to charge the battery once a month if the FIREBOY plus is not used regularly. If the FIREBOY plus is not used for more than 3 months, unplug the battery.
1.4.4 Restrictions for use
The following uses of the FIREBOY plus are prohibited:
• rotating it and using it upside down
• using it as a cooker without the optionally available long burner head, see “7.1
Accessories” on page 24.
• carrying it by the burner head because the device may fall down