Instek GDS-1072B, GDS-1102B, GDS-1054B, GDS-1074B, GDS-1104B QuickStart Guide

Digital Storage Oscilloscope
properties.
instrument was purchased.
User manual CD
Power Cord x1
Region Dependent
Instrument cart, 470(W) x
GTC-001
Instrument cart, 330(W) x
GTC-002 Test lead, BNC to BNC heads
GTL-110
4P
Go-NoGo
Go-NoGo testing app.
*Optional apps are available as a free download from
11
4
68
10
3
1
5
9
7
2
5. Waveform Frequency
6. Trigger Configuration
7. Horizontal status
8. Bottom Menu
VARIABLE
POSITION
HORIZONTAL
TRIGGER
LEVEL
PUSH TO
ZERO
PUSH TO ZERO
SCALE
Measure
Display
Cursor
Help
APP
Save/Recall
Acquire
Utility
Autoset
Run/Stop
Single
Default
Select
Search
Set/Clear
Zoom
Menu
50 %
Force-Trig
POSITION
POSITION
VERTICAL
MATH
REF
BUS
SCALESCALE
PUSH TO
ZERO
PUSH TO
ZERO
M
R
B
POWER
CH1 CH2 EXT TRIG
2V
CAT I
1M
W
16pF
300Vrms MAX.
CAT I
1M
W
16pF
300Vrms MAX.
2
3
18
4
6
11
13
1
15
10
14
5
16
7
12
8
17
9
LINE VOLTAGE
AC 100 240V
RANGE
FREQUENCY 50 60Hz
POWER MAX. 30 Watts
CAUTION
TO AVOID ELECTRIC SHOCK THE POWER CORD PROTECTIVE GROUNDING
DO NOT REMOVE COVERS. REFER SERVICING TO QUALIFIED PERSONNEL.
CONDUCTOR MUST BE CONNECTED TO GROUND.
Ser. No. Label
7
3
4
56
21
GDS-1000B Series
QUICK START GUIDE
GW INSTEK PART NO. 82DS-1KB01ME1
-9001 CERTIFIED MANUFACTURER
ISO
SAFETY INSTRUCTIONS
This section contains the basic safety symbols that may appear on the accompanying User Manual CD or on the instrument. For detailed safety instructions and precautions, please see the Safety Instructions chapter in the user manual CD.
Safety Symbols
These safety symbols may appear in the user manual or on the instrument.
Warning: Identifies conditions or practices that could result in injury or
Warning
Caution
loss of life.
Caution: Identifies conditions or practices that could result in damage to the instrument or to other
DANGER High Voltage
Attention Refer to the Manual
Protective Conductor Terminal
Earth (ground) Terminal
Do not dispose electronic equipment as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this
1
Power Cord for the United Kingdom
When using the instrument in the United Kingdom, make sure the power cord meets the following safety instructions.
NOTE: This lead/appliance must only be wired by competent persons.
WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in this lead are coloured in accordance with the following code:
Green/ Yellow: Earth Blue: Neutral Brown: Live (Phase)
As the colours of the wires in main leads may not correspond with the coloured marking identified in your plug/appliance, proceed as follows: The wire which is coloured Green & Yellow must be connected to the Earth terminal marked with either the letter E, the earth symbol
or coloured Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Blue or Black. The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red. If in doubt, consult the instructions provided with the equipment or contact the supplier. This cable/appliance should be protected by a suitably rated and approved HBC mains fuse: refer to the rating information on the equipment and/or user instructions for details. As a guide, a cable of
2
should be protected by a 3A or 5A fuse. Larger conductors
0.75mm would normally require 13A types, depending on the connection method used. Any exposed wiring from a cable, plug or connection that is engaged in a live socket is extremely hazardous. If a cable or plug is deemed hazardous, turn off the mains power and remove the cable, any fuses and fuse assemblies. All hazardous wiring must be immediately destroyed and replaced in accordance to the above standard.
2
GETTING STARTED
The Getting started chapter introduces the oscilloscope's main features, appearance, and set up procedure.
Main Features
Model name Frequency bandwidth Input channels
GDS-1072B 70MHz 2
GDS-1102B 100MHz 2
GDS-1054B 50MHz 4
GDS-1074B 70MHz 4
GDS-1104B 100MHz 4
Features
7 inch, 800 X 480 TFT WVGA display.
Models available from 50MHz to 100MHz.
Real-time sampling rate of 1GSa/s, max.
Record length: 10M points record length.
Waveform capture rate of 50,000 waveforms per second.
Vertical sensitivity: 1mV/div~10V/div.
On-screen Help.
32 MB internal flash disk.
Go-NoGo app.
Remote Disk app (4 ch. only).
3
Interface
USB host port: front panel, for storage devices.
USB device port: rear panel, for remote control or printing (to PictBridge compatible printers).
Probe compensation output with selectable output frequency (1kHz ~ 200kHz).
Ethernet port (GDS-1054B, GDS­1074B, GDS-1104B only).
Calibration output.
4
This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of Good Will Corporation.
The information in this manual was correct at the time of printing. However, Good Will continues to improve its products and therefore reserves the right to change the specifications, equipment, and maintenance procedures at any time without notice.
Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan.
Package Contents and Accessories
Standard Accessories
Item
Quick Start Guide (this document) Passive Probe; 70 MHz for GTP-070B-4 GDS-1054B, GDS-1072B, GDS-1074B Passive Probe; 100 MHz for GTP-100B-4 GDS-1102B, GDS-1104B
Optional Accessories
Item Model Number
430(D)mm (U.S. type input socket)
430(D)mm (U.S. type input socket)
USB cable, USB2.0A-B type cable
Passive Probe; 70 MHz GTP-070B-4 Passive Probe; 100 MHz GTP-100B-4
Standard Apps*
Name Description
Remote Disk Allows the scope to mount a network
share drive (4 channel models only).
the GW Instek website at www.gwinstek.com.
Model Number
GTL-242
5
Display and Panel Overview
Display Overview
Description
1. Memory Bar 2. Trigger Status
3. Acquisition Status 4. Side Menu
9. Channel Status 10. Channel/Reference/ Math Indicators
11. Horizontal Position
6
Front Panel
Description
1. Hardcopy key 2. Variable knob and
3. Function keys 4. Autoset, Run/Stop,
5. Horizontal and Search* controls
7. Vertical controls 8. EXT trigger input
9. Analog channel inputs
11. Probe calibration output
13. Power button 14. Bottom menu keys
15. Option* key 16. Menu off key
17. Side menu keys 18. LCD
*The Bus, Search and Option keys are not available on the GDS-1000B.
Select key
Single & Default keys
6. Trigger controls
(2CH only)
10. Math, Reference & Bus* keys
12. USB Host port
7
Rear Panel
Description
1. USB device port 2. LAN port (GDS-1054B, GDS-1074B, GDS­1104B only)
3. Go-NoGo output 4. Key lock slot
5. Power input socket 6. Fan
7. Calibration output
8
Setting up the Oscilloscope

3. Set the probe attenuation voltage to x10.
VARIABLE
POSITION
HORIZONTAL
POSITION
POSITION
POSITION
POSITION
VERTICAL
MATH
REF
BUS
SCALE
TRIGGER
LEVEL
PUSH TO
ZERO
SCALESCALESCALE
PUSH TO
ZERO
PUSH TO
ZERO
PUSH TO
ZERO
PUSH TO ZERO
PUSH TO
ZERO
SCALE
POWER
CH1 CH2 CH3 CH4
2V
CAT I
1M
W
16pF
300Vrms MAX.
Measure
Display
Cursor
Help
APP
Save/Recall
Acquire
Utility
Autoset
Run/Stop
Single
Default
Select
Search
Set/Clear
Zoom
CH1 CH2 CH3 CH4
M
R
B
Menu
50 %
Force-Trig
x1
x10
X 10
X 1




Under
Compensation
Normal
Over
Compensation
start to use the oscilloscope.
DC coupling: DC ~ 50MHz
4
7ns
20MHz
DC coupling: DC ~ 70MHz
2 + EXT (GDS-1072B) 5ns
20MHz
DC coupling: DC ~ 100MHz
:1mV~10V/div
Normal & Invert
300Vrms, CAT I
FFT: Spectral magnitude. Set
±15V
CH1, CH2, CH3*, CH4*, Line, Auto (supports Roll Mode for
Edge, Pulse Width(Glitch),
Delay (Duration: 4ns~10s)
5ns/div ~ 100s/div (1-2-5
10 div maximum
2,000,000 div maximum
2ns (typical)
Selectable from 2 to 256
Channel 1; Channel 3*
Channel 2; Channel 4* ±3° at 100kHz
36 sets: Pk-Pk, Max, Min,
LFF, Phase
Single-button, automatic setup
20set
24set
7" TFT WVGA color display
800 horizontal × 480 vertical Sin(x)/x
Dots, vectors, variable 50,000 waveforms per second, 8 x 10 divisions
YT, XT
USB 2.0 High-speed host port
RJ-45 connector, 10/100Mbps
5V Max/10mA TTL open
Rear-panel security slot
Kensington-style lock
Available
Temperature: 0°C to 50°C
Available
384mm x 208mm x 127.3mm
2.8kg
Type of Product: Digital Storage Oscilloscope Model Number: GDS-1104B, GDS-1102B, GDS-1174B, GDS-1072B,
EMC
EN 61326-1: EN 61326-2-1:
Electrical equipment for measurement, control and laboratory use –– EMC requirements (2013)
Conducted & Radiated Emission EN 55011: 2016
Electrical Fast Transients EN 61000-4-4: 2012
Current Harmonics EN 61000-3-2: 2014
Surge Immunity EN 61000-4-5: 2014
Voltage Fluctuations EN 61000-3-3: 2013
Conducted Susceptibility EN 61000-4-6: 2014
Electrostatic Discharge EN 61000-4-2: 2009
Power Frequency Magnetic Field EN 61000-4-8: 2010
Radiated Immunity EN 61000-4-3: 2006+A1: 2008+A2: 2010
Voltage Dip/ Interruption EN 61000-4-11: 2004
Low Voltage Equipment Directive 2014/35/EU
Safety Requirements
EN 61010-1: 2010 (Third Edition) EN 61010-2-030: 2010 (First Edition)
This section describes how to set up the oscilloscope properly including setting the stand, installing the optional modules and compensating the probe.
Tilting the Stand
The GDS-1000B has two adjustable tabs at the front that can be used to position the instrument into two preset orientations.
1. Pull the tabs out to lean the scope back.
2. Push the tabs under the casing to stand upright.
Probe Compensation
This section describes how to connect a signal, adjust the scale, and compensate the probe. Before operating the GDS-1000B in a new environment, run these steps to make sure the instrument performs at its full potential.
1. Press the
the factory settings.
2. Connect the probe to the Channel 1 input and to the probe calibration output. This output provides a 2Vp-p, 1kHz square wave for signal compensation by default.
key to reset the system to
4. Press the
5. A square waveform will appear in the center of the display.
6. Press the
waveform type from the bottom menu.
7. Turn the adjustment point on the probe to flatten the square waveform edge.
key.
key and select the Vector
8. Setting up the oscilloscope is complete. You may
SPECIFICATIONS
The specifications apply when the oscilloscope is powered on for at least 30 minutes under +20°C~+30°C.
Model Specific Specifications
GDS-1054B Bandwidth (–3dB) Channels Rise Time Bandwidth Limit
GDS-1072B & GDS-1074B Bandwidth (–3dB) Channels
Rise Time Bandwidth Limit
GDS-1102B & GDS-1104B Bandwidth (–3dB) Channels
Rise Time Bandwidth Limit
4 (GDS-1074B)
2 + EXT (GDS-1102B) 4 (GDS-1104B)
3.5ns 20MHz
Common Specifications
Vertical Resolution
Input Coupling Input Impedance DC Gain Accuracy
Polarity Maximum Input Voltage Offset Position Range
Waveform Signal Process
xternal Trigger
E Range Sensitivity Input Impedance
8 bit
AC, DC, GND 1MΩ// 16pF approx 1mV: ±4% full scale >2mV: ±3% full scale
1mV/div: ±1.25V 2mV/div ~ 100mV/div: ±2.5V 200mV/div ~ 10V/div: ±125V +, -, ×, ÷, FFT, FFTrms, User defined expression
FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman-Harris
DC ~ 100MHz Approx. 100mV 1MΩ±3% ~ 16pF
Trigger Source
Trigger Mode
Trigger Type
Holdoff range Coupling
Sensitivity
orizontal
H Timebase Range
Pre-trigger Post-trigger Timebase Accuracy
Real Time Sample Rate Record Length Acquisition Mode
Peak Detection Average
EXT** *4 channel models only. **2 channel models only.
100 ms/div and slower), Normal, Single
Video, Pulse Runt, Rise & Fall, Timeout, Alternate, Event­Delay (1~65535 events), Time-
4ns to 10s AC, DC, LF rej., HF rej., Noise rej. 1 div
increments) ROLL: 100ms/div ~ 100s/div
±50 ppm over any ≥ 1ms time interval 1GSa/s, max. Maximum 10Mpts Normal, Average, Peak Detect, Single
9
X-Y Mode X-Axis Input
Y-Axis Input
Phase Shift
Cursors and Measurement Cursors
Automatic Measurement
Cursors measurement
Auto counter
C
ontrol Panel Function
Autoset
Save Setup Save Waveform
*4 channel models only.
*4 channel models only.
Amplitude, Time, Gating available; Unit: seconds(s), Hz(1/s), Phase(degree), Ration(%)
Amplitude, High, Low, Mean, Cycle Mean, RMS, Cycle RMS, Area, Cycle Area, ROVShoot, FOVShoot, RPREShoot, FPREShoot, Frequency, Period, RiseTime, FallTime, +Width, ­Width, Duty Cycle, +Pulses, ­Pulses, +Edges, -Edges, FRR, FRF, FFR, FFF, LRR, LRF, LFR,
Voltage difference between
cursors ( ∆V) Time difference between cursors ( ∆T)
6 digits, range from 2Hz minimum to the rated bandwidth
of all channels for vertical, horizontal and trigger systems, with undo Autoset
14
Display TFT LCD Type Display Resolution
Interpolation Waveform Display
Waveform Update Rate
Display Graticule Display Mode
10
pixels (WVGA)
persistence (16ms~4s), infinite persistence
maximum
15
Interface USB Port
Ethernet Port
Go-NoGo BNC
Kensington Style Lock
Miscellaneous Multi-language menu Operation Environment
On-line help Dimensions Weight
11
X1, USB High-speed 2.0 device port X1
with HP Auto-MDIX. (Only for the GDS-1054B, GDS-1074B, GDS-1104B)
collector output
connects to standard
Relative Humidity: ≤ 80% at 40°C or below; ≤ 45% at 41°C ~ 50°C
16
12
EC Declaration of Conformity
We GOOD WILL INSTRUMENT CO., LTD. declare that the below mentioned product
are herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Law of Member States relating to the EMC: 2014/30/EU, LVD: 2014/35/EU, WEEE: 2012/19/EU and RoHS: 2011/65/EU. For the evaluation regarding the Electromagnetic Compatibility and Low Voltage Directive, the following standards were applied:
GOODWILL INSTRUMENT CO., LTD.
No. 7-1, Jhongsing Road, Tucheng District, New Taipei City 236, Taiwan Tel: +886-2-2268-0389 Fax: +886-2-2268-0639 Web: http://www.gwinstek.com Email: marketing@goodwill.com.tw
GOODWILL INSTRUMENT (SUZHOU) CO., LTD.
No. 521, Zhujiang Road, Snd, Suzhou Jiansu 215011, China Tel: +86-512-6661-7177 Fax: +86-512-6661-7277 Web: http://www.instek.com.cn Email: marketing@instek.com.cn
GOODWILL INSTRUMENT EURO B.V.
De Run 5427A, 5504DG Veldhoven, The Netherlands Tel: +31-(0)40-2557790 Fax: +31-(0)40-2541194
GDS-1054B
Email: sales@gw
17
instek.eu
-
13
Loading...