Ingersoll-Rand DS15-H, DS25-H, DS50-H, DS35-H, DS75-H, DS100-H User Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
GB
User manual
Page1
F
ES
P
D
Manuel d’utilisation
Manual de uso
Manual do utilizador
Benutzerhandbuch
Page7
Página13
Página19
Seite25
DS15--H---D S 1 0 0 --H
refrigeration dryer (60Hz)
DATE: 06.11.2002ISSUE: 2
272716
CPN: 85616902
Index
1Introductionpage2
1.1Forewordpage2
1.2Packagingpage2
1.3Transportpage2
1.4Storagepage2
1.5Inspectionpage2
2Installationpage2
2.1Dryer installationpage2
2.2Electrical connectionpage3
2.3Condensate drainpage3
3Start--- up and operationpage3
3.1Preliminary checkspage3
3.2Starting the dryerpage3
3.3Stopping the dryerpage4
3.4Operationpage4
4Maintenancepage4
4.1Preventive maintenancepage4
4.2Substituting an exhausted elementpage4
4.3Disassembling t he unitpage5
4.4Refrigerant leaks in the refrigeration circuitpage5
4.5Refrigerant chargingpage5
5Calibrationpage5
Safety warnings
Important:
S Keep this manual with the machine throughout its entire service life.
S Carefully read this manual before carrying out any operation on the machine.
S This m achine is designed for PROFESSIONAL USE only. Only use the ma-
chine for the purpose for which it is intended. Improper use of the machine
absolves the manufacturer from all liability.
This manual has been compiled to help the final user perform just those operations which do not require removal of the panels.
All other operations which involve the removal of covers from instruments or
electrical circuit--- breakers using special tools must only be carried out by
trained personnel due to the danger of rotating parts or live components.
Each machine is equipped with an electric disconnect device whichallows theoperator to work on the machinein absolute safety. This device must always be used
to disconnect the mains supply to avoid any risk of danger during maintenance
work (electric shocks, scalding, automatic start--- up, moving parts and remote
control).
Before servicing the dryer always make sure the compressed air circuit is depressurised.
When requesting technical assistance or ordering spare parts, always quote the
model and serial number on the identification plate mounted externally on the
unit.
IMPORTANT: data contained in this publication is to be considered as indicative
only. The manufacturer reserves the right to modify data without prior notice.
6Spare parts listpage5
7Troubleshootingpage6
CPN: 85616902 --- DS15-- H --- D S 1 0 0 -- H
English
1
CPN: 85616902 --- DS15-- H --- D S 1 0 0 -- H
English
2
2
All figures to which the “see Fig.” references in this text refer can be found at the
end this manual. The language translations for these figures can be found in the
Legend (A3--- sized page) inserted after all the figures.
1Introduction
1.1Foreword
The DS- H dryers are designed to guarantee high quality compressed air and minimum maintenance.
Please carefully read this manual to obtain maximum performance from your dryer
and ensure its correct installation and start ---up in compliance with manufacturer instructions.
1.2Packaging
The dryer is packaged with a strong cardboard box strapped to a wooden pallet.
Instruction symbols (UNI ISO 780) for the movement, transport and stocking of the
product are printed on two sides of the packing.
1.3Transport
S Keep the unit in an upright position and do not leave it outdoors.
S Use a forklift truck to move the machine.
S Care should be taken to avoid damaging internal components through poor
handling during movement, installation or use.
S Unpack the machine as close as possible to the installation site.
1.4Storage
If stored the packaged units must be kept inside, protected from humidity, direct
sunlight and rain.
Moreover, although stacking is permitted the maximum weight must not be more
than the value shown on the packaging.
1.5Inspection
On receipt of the machine, make sure it has incurred no damage during transit.
If any damage is detected promptly contact the haulage company.
2Installation
2.1Dryer installation (see Fig. 1)
THIS WAY UP
KEEP DRYDO NOT ROLLSTACKING
FRAGILE: HANDLE
WITH C ARE
USE NO HOOKS
Kg max
LIMITATION
a) Dryer should be installed indoors; where this is not possible it must however be
installed in a clean dry area, with a temperature within the limits 41---115˚F
( 5 --- 4 6 ˚C), and sheltered from the effects of direct weather (including direct sun-
light); do not install the dryer in rooms used for laundry operations.
b) The compressed air inlet temperature must never exceed 200˚F(93˚C). For dif-
ferent temperatures to those indicated above, consult the manufacturer.
c) For most compressed air applications we recommend following the installation
plan (see Fig. 1). This layout ensures optimum compressor, filter and dryer performance and also guarantees excellent air qua lity whilst minimising operating
costs.
d) Donotobstructthedryerairgrilles.
e) Allow sufficient gap around the unit to facilitate maintenance and ensure unim-
peded air discharge from the condenser.
f) Avoid recirculation of hot condenser air back into t he condenser air inlet.
.
g) If the system is prone to instantaneous pressure surges which exceed the dryer’s
rated capacity, mount a suitably sized receiver near the overpressure source. For
more precise information, contact the manufacturer or distributor.
h) Installing a by--- pass line with shut---off valves (supplied as option) is suggested
to permit maintenance or calibration without interrupting the compressed air
flow to the user.
Pay attention when you by--- pass the aftercooler section, as this will cause hot air
to flow through the compressed air network.
i) Correctly connect the dryer to the air inlet and outlet connections. If the com-
pressed air network is prone to vibrations, use hoses to make the connections.
If the mains is subject to high levels of pulsation, ensure that the connection is
equipped with pulsation dampers.
j) Do not connect condensate drains common to other pressurised drain lines in a
closed circuit. Make sure the outflow from the condensate drains is unimpeded.
Connect the condensate piping in such a way to ensure that sound levels are kept
to a minimum during drainage.
Ensure that all condensate is disposed of in a responsible manner, in accordance
with local norms concerning environmental protection.
k) The ambient air around the dryer and compressor must not contain solid or gas-
eous contaminants. All compressed and condensed gases can generate acids or
chemical products which may damage the compressor or components inside the
dryer.
Take particular care with sulphur, ammonia, chlorine and installations in marine
environments. For further advice or assistance consult the manufacturer.
2.2Electrical connection (see Fig. 5 / Fig. 10)
The dryer is supplied with a 3 x AWG16 power cable complete with plug.
2.3Condensate drain
The dryer is supplied either with a float drain (see Fig. 9), a timed drain or an electronic level sensing drain.
Fortimed and electronic drains:refer to separate manual supplied with the dryer for
specific details concerning the condensate drain.
3Start---up and operation
3.1Preliminary checks
Beforestartingupthedryer,makesurethat:
a) the air inlet valves are closed and there is no air flow through the dryer.
b) The mains power supply is commensurate with the dryer voltage.
c) The dryer is installed in compliance with the installation instructions given in
Chapter 2.
3.2Starting the dryer
a) Use the switch to start the dryer.
b) Always start up the dryer before activating the air compressor.
c) Waitabout 5 minutes until the dryer is running at the correct operatingtempera-
tures and pressures.
d) Slowly open the air inlet valve to pressurise the dryer.
e) Slowly open the air outlet valve. The dryer is now operating (drying).
f) Always leave the dryer running while the air compressor is operating.
g)
After stopping the dryer wait at least 3 minutes before starting it again
Install an overcurrent and earth leakage circuit breaker upstream from the
plant (IDn = 0.03A) with a 0.12 inch (3 mm) gap between contacts when open (refer
also to local laws).
CPN: 85616902 --- DS15-- H --- D S 1 0 0 -- H
3.3Stopping the dryer
a) Use the switch to stop the dryer.
English
3
CPN: 85616902 --- DS15-- H --- D S 1 0 0 -- H
y
WEEKL
Y
CONDENATEDRAI
N
MONTHLY
Mak
t
h
d
t
200F(93C)
EVERY4MONTH
S
specification
s
English
4
4
b) Stop the dryer 2 minutes after shutting down the air compressor or interrupting
the air flow to the dryer.
Avoidallowingcompressedairtoenterthedr
er when the dryer is
switchedofforwhenitisinanalarmsituationwhichstopstherefrigeration
compressor.
3.4Operation
S The dryer operates automatically. It is factory set for a dew point of 50˚F(10˚C)
and therefore requires no further calibration.
S Do not exceed the machine’s design limits, by---pass excess air flow and check the
unit model and/or installation.
S For maximum performance from your dryer, follow the maintenance schedule de-
scribed i n Chapter 4.
S The sound pressure level recorded for these dryers 40 inch (at 1 metre) from the
machine in free fieldconditionsis less then50 dB(A) (models DS15-- H), 55dB(A)
(models DS25-- H --- D S 1 0 0 -- H)
Fig. 6 shows the Dryer’s refrigeration and air circuits.
N.B.: In the event of aftercooler fan malfunction leading to an increase in the tem-
perature within the filter, to above 149˚F(65˚C), check the integrity of the filter’s
element and drain and substitute these components if necessary.
4Maintenance
4.1Preventive maintenance
For optimum performance from your dryer follow the periodic maintenance schedule described below.
CONDENATE DRAIN
Verify that the condensate drain is draining correctly.
COMPRESSOR
˚
˚
YEARLY
esure
when running. If this is not the case consult Chapter 7.
REFRIGERANT CONDENSER AND AFTERCOOLER
Remove any dust from the condenser/aftercooler fins.
COMPRESSOR
Make sure compressor power consumptioncomplieswith data plate
AFTERCOOLER FAN MOTOR
S
Check that the fan rotates freely without any abnormal noise.
S
Make sure fan power consumption complies with the specifications on the fan’s data plate.
AFTERCOOLER
If necessary (coil blocked) remove the fan and clean the coil in the
opposite direction to the air flow using a high pressure water jet (this
operation must be performed by a technician to avoid damage).
FILTER ELEMENT
Replace the filter element (see para. 4.2)
CONDENSATE DRAIN
Completely disassemble the drain and clean all its components (see
Fig. 9 or separate manual, according to installed drain type).
e compressorhea
.
emperatureisbelow
Before accessing live electrical parts, disconnect the power supply to the
dryer using disconnect switch QS or disconnect the cable connections.
SAFETY DEVICES
SK overload protector
HP high pressure switch (installed on models DS50-- H --- D S 1 0 0 -- H)
COMPRESSOR TYPE
HERMETIC, PISTON (single phase)
N.B.: Always use original spares supplied by the manufacturer.
Failure to do so renders the manufacturer not liable for incorrect unit operation.
4.2Substituting an exhausted element (Fig. 9)
N.B.: Don’t touch the element sock with your bare hands; use gloves.
a) Shut off or by---pass air supply to dryer.
b) Depressurise filter usingmanual or automatic drainvalve (18). Leave valveopen.
c) Unscrew (anticlockwise) filter body from head.
d) Unscrew and remove element (17).
e) Clean inside of filter if necessary.