INGENICO IST150 User Manual

iST150 INSTALLATION GUIDE
Graphic display
Contactless
Contactless lights
Angle position
Safety instruction
Power supply network: To switch off the iST150, disconnect first the link to the host and then the power adapter (if there is one) from the power supply network
For Pluggable Equipment Type A, the protection in the installation is assumed to be 20A. Only power adapter supplied by Ingenico must be used.
active area
Push the two buttons on each side at the same time and adjust the angle.
Reading card Contactless
Keep the card firmly up to the active area. Keep the card motionless to the target during the transaction.
Your contactless terminal has a row of four status lights that are visible from the front and back side.
Installing SAM and cable
Before starting, switch off the terminal by (see safety instruction). In order to access the SAM card you must first remove the cover located at the back:
on both side
buttons
Insert the SAM into the slot market (1), (2).
Press the clip of the cover and lift the cover
90000346 R11 000 01/4710 Copyright © 2010 Ingenico INGENICO – 192 avenue Charles de Gaulle 92200 Neuilly sur Seine – France All rights reserved
Hang on the connector
Take care to ensure that the SAM Card is inserted in the correct manner. The cut corner must be positioned as indicated on the picture.
To position the cable put it in the slot then proceed in reverse order.
iST150 INSTALLATION GUIDE
Physical characteristics: Weight (without cable) About 150g Dimensions 83x 27 x124 mm (lxWxH) Removable cable
Operating conditions: Temperature +5°C to +40°C Maximum relative humidity 85% RH at +40°C
Storage conditions: Temperature -20°C to +55°C Maximum relative humidity 85% RH at +55°C
Maximum consumption: 400mA at +5V, 300mA at +8V to +12V
Power Supply Voltage is a SELV circuits (Safety Extra Low Voltage, according to safety standard IEC 60950-1). The power supply has to be in compliance with §2.5 (Limited power source) of the standard IEC 60950-1