Ihse Draco vario IP CPU User Manual

Page 1
IHSE GmbH Maybachstraße 11 88094 Oberteuringen Germany
info@ihse.com www.ihse.com phone: +49 7546-9248-0 fax: +49 7546-9248-48
Draco vario IP CPU
488 Series
User Manual
Edition: 2018-07-12
Page 2
Draco vario IP CPU KVM KVM Extender
2 2018-07-12
Copyright
© 2018. All rights reserved. This information may not be reproduced in any manner without the prior written consent of the manufacturer.
Information in this document is subject to change without notice.
Trademarks
All trademark and trade names mentioned in this document are acknowledged to be the property of their respective owners.
Disclaimer
While every precaution has been taken during preparation of this manual, the manufacturer assumes no liability for errors or omissions. The manufacturer assumes no liability for damages resulting from the use of the information contained herein.
The manufacturer reserves the right to change specifications, functions, or circuitry of the product without notice.
The manufacturer cannot accept liability for damage due to misuse of the
product or due to any other circumstances outside the manufacturer’s
control (whether environmental or installation related). The manufacturer shall not be liable for any loss, damage, or injury arising directly, indirectly, incidentally, or consequently from the use of this product.
Page 3
Contents
2018-07-12 3
Contents
1 About This Manual ....................................................................... 6
1.1 Scope .................................................................................. 6
1.2 Validity ................................................................................ 6
1.3 Cautions and Notes ............................................................ 6
2 Safety Instructions ....................................................................... 7
3 Description ................................................................................... 8
3.1 Application .......................................................................... 8
3.2 System Overview ................................................................ 9
3.3 Product Range .................................................................. 10
3.3.1 Part Numbers ...................................................... 10
3.3.2 Chassis ............................................................... 10
3.3.3 KVM Extender Modules ...................................... 11
3.3.4 Monitoring Modules ............................................. 11
3.4 Accessories Upgrade Kits ................................................. 12
3.5 Accessories ....................................................................... 13
3.6 Device Views .................................................................... 14
3.6.1 2-fold Vario Chassis 474-BODY2/2R .................. 14
3.6.2 2-fold Vario Chassis 474-BODY2N ..................... 14
3.6.3 4-fold Vario Chassis 474-BODY4/4R .................. 15
3.6.4 6-fold Vario Chassis 474-BODY6R ..................... 16
3.6.5 6-fold Vario Chassis 474-BODY6BP ................... 17
3.6.6 6-fold Vario Chassis 474-BODY6BPF ................. 18
3.6.7 21-fold Vario Chassis 474-BODY21R ................. 19
3.6.8 Model L488-BIPEC / -BIPECR ............................ 20
3.6.9 Model L488-BIPES / -BIPESR ............................ 20
3.6.10 Model 474-SNMP ................................................ 21
3.7 Status LEDs ...................................................................... 22
3.7.1 Status KVM Extender Module ............................. 22
3.7.2 Status Monitoring Module SNMP ........................ 24
Page 4
Draco vario IP CPU KVM KVM Extender
4 2018-07-12
4 Installation .................................................................................. 25
4.1 Package Contents ............................................................. 25
4.2 System Setup .................................................................... 26
4.2.1 KVM Extender Setup .......................................... 26
4.3 Example Applications ........................................................ 27
5 Configuration .............................................................................. 28
5.1 Transmission Parameters ................................................. 28
5.2 DDC Settings .................................................................... 28
5.3 Command Mode ............................................................... 29
5.4 USB-HID Ghosting ............................................................ 31
5.5 Configuration File .............................................................. 32
5.5.1 Parameters for CPU Units ................................... 32
5.6 Remote Access Configuration ........................................... 34
6 Operation .................................................................................... 38
6.1 Download of DDC Information .......................................... 38
6.2 Shared Operation of redundant CPU Units ....................... 38
7 Specifications ............................................................................. 40
7.1 Interfaces .......................................................................... 40
7.1.1 Single Link .......................................................... 40
7.1.2 USB-HID ............................................................. 40
7.1.3 USB 2.0 (transparent) ......................................... 41
7.1.4 RJ45 (Interconnect) ............................................ 41
7.1.5 Fiber SFP Type LC (Interconnect) ...................... 41
7.1.6 RJ45 (Network) ................................................... 42
7.2 Interconnect Cable ............................................................ 43
7.2.1 Cat X ................................................................... 43
7.2.2 Fiber .................................................................... 44
7.3 Supported Peripherals ...................................................... 45
7.3.1 USB-HID Devices ............................................... 45
7.3.2 USB 2.0 Devices ................................................. 45
7.4 Supported Network Protocols ........................................... 46
7.5 Connector Pinouts ............................................................ 47
Page 5
Contents
2018-07-12 5
7.6 Power Supply .................................................................... 48
7.7 Environmental Conditions ................................................. 49
7.8 Size ................................................................................... 49
7.9 Shipping Weight ................................................................ 50
8 Troubleshooting ......................................................................... 51
8.1 General Failures ............................................................... 51
8.2 Blank Screen ..................................................................... 52
8.3 USB-HID ........................................................................... 53
8.4 USB 2.0 embedded ........................................................... 54
8.5 Compute Module ............................................................... 55
9 Technical Support ...................................................................... 56
9.1 Support Checklist .............................................................. 56
9.2 Shipping Checklist ............................................................ 56
10 Certificates .................................................................................. 57
10.1 CE Declaration Of Conformity ........................................... 57
10.2 North American Regulatory Compliance ........................... 58
10.3 Product Safety .................................................................. 59
10.4 WEEE ............................................................................... 59
10.5 RoHS/RoHS 2 ................................................................... 59
11 Glossary ...................................................................................... 60
Pos: 1 /806-IHSE/Zu diesem Handbuch/ATB_Zu diesem Handbuch @ 5\mod_1278573163276_6.doc @ 41510 @ 1222 @ 1
Page 6
Draco vario IP CPU KVM KVM Extender
6 2018-07-12
1 About This Manual
1.1 Scope
This manual describes how to install your KVM Extender, how to operate it and how to perform trouble shooting.
1.2 Validity
This manual is valid for all devices listed on the front page. The product code is printed on the base of the devices.
1.3 Cautions and Notes
The following symbols are used in this manual:
This symbol indicates an important operating instruction that should be followed to avoid any potential damage to hardware or property, loss of data, or personal injury.
This symbol indicates important information to help you make the best use of this product.
This symbol indicates best practice information to show recommended and optimal ways to use this product in an efficient way.
Pos: 2 /806-IHSE/Sicherheitshinweise/ATB_Sicherheitshinweise @ 5\mod_1278573321245_6.doc @ 41528 @ 1 @ 1
Page 7
Safety Instructions
2018-07-12 7
2 Safety Instructions
To ensure reliable and safe long-term operation of your KVM Extender please note the following guidelines:
Installation
1. Only use in dry, indoor environments.
2. Only use the device according to this User Manual. Failure to follow these procedures could result in damage to the equipment or injury to the user or installer.
3. The KVM Extender and the power supply units can get warm. Do not install components in an enclosed space without any airflow.
4. Do not place the power supply directly on top of the device.
5. Do not obscure ventilation holes.
6. Only use power supplies originally supplied with the product or manufacturer-approved replacements. Do not use a power supply if it appears to be defective or has a damaged chassis.
7. Connect all power supplies to grounded outlets. In each case, ensure that the ground connection is maintained from the outlet socket through to the power supply's AC power input.
8. Do not connect the link interface to any other equipment, particularly network or telecommunications equipment.
9. Take any required ESD precautions.
In order to disconnect the device completely from the electric circuit, all power cables have to be removed.
Repair
10. Do not attempt to open or repair a power supply unit.
11. Do not attempt to open or repair the KVM Extender. There are no user serviceable parts inside.
12. Please contact your dealer or manufacturer if there is a fault.
Pos: 3 /806-IHSE/Beschreibung/UEB_Beschreibung @ 5\mod_1278573379151_6.doc @ 41546 @ 1 @ 1
Page 8
Draco vario IP CPU KVM KVM Extender
8 2018-07-12
3 Description
Pos: 4 /806-IHSE/Beschreibung/Verwendungszweck/474-xx @ 6\mod_1304579672848_6.doc @ 50785 @ 2 @ 1
3.1 Application
The KVM Extender is used to increase the distance between a source (computer, CPU) and its console (keyboard, mouse, and other peripheral devices).
The KVM Extender is designed for use with Cat X (Twisted Pair) interconnect cables or fiber interconnect cables.
The KVM Extender with Cat X interconnect cables is unsuitable for connection between buildings where a fiber optic-based product should be used instead.
The KVM Extender with fiber interconnect cables can also be used with applications in environments which are subject to electromagnetic interference. Electromagnetic interference can limit the maximum distance and reliability of operation.
Pos: 5 /806-IHSE/Beschreibung/System-Übersicht /474-xx @ 6\mod_1304579735410_6.doc @ 50803 @ 2 @ 1
Page 9
Description
2018-07-12 9
3.2 System Overview
The KVM Extender consists of at least one IP CPU module and one CON module. The various modules are summarized respectively in a vario chassis (2-fold, 4-fold or 6-fold) at CPU site and CON site (CPU and CON Unit).
The IP CPU module is connected the source (computer, CPU) via TCP/IP network cable.
The CON module is connected to the console (monitor, keyboard and mouse).
The CPU Unit and the CON modules communicate with each other through the interconnect cables.
System Overview
1 Source (computer, CPU) 2 TCP/IP network cable 3 KVM Extender IP CPU Unit 4 Interconnect cable 5 KVM Matrix 6 KVM Extender CON Unit 7 Console (monitor, keyboard, mouse)
See Chapter 4.3, Page 27 for installation examples.
Pos: 6 /806-IHSE/Beschreibung/Gerätetypen/481-xx @ 9\mod_1367825450210_6.doc @ 71653 @ 233333 @ 1
Page 10
Draco vario IP CPU KVM KVM Extender
10 2018-07-12
3.3 Product Range
3.3.1 Part Numbers
Part numbers for Connections via Cat X or Fiber Cable
All devices are available in the following versions:
Connection via Cat X cable (x = "C")  Connection via Single-mode fiber cable (x = "S")
Fiber devices can be used with Multi-mode and Single-mode cables (see Chapter 7.2.2, Page 44).
Part numbers for CPU Unit and CON Unit
The part numbers for the CPU Unit and the CON Unit can be derived from the part number of the complete device.
CPU Unit: L488  CON Unit: R488
All devices in the K488 series are technically compatible with devices in the K47x and K48x series.
3.3.2 Chassis
Model
Description
474-BODY2
Empty chassis for up to 2 boards, 1x external power supply unit
474-BODY2R
Empty chassis for up to 2 boards, 1x external power supply unit, preparation for redundancy for a second power supply unit (external)
474-BODY2N
Empty chassis for up to 2 boards, 1x internal power supply unit, preparation for redundancy for a second power supply unit (external)
474-BODY4
Empty chassis for up to 4 boards, 1x external power supply unit
474-BODY4R
Empty chassis for up to 4 boards, 1x external power supply unit, preparation for redundancy for a second power supply unit (external)
474-BODY6R
Empty chassis for up to 6 boards, 1x internal power supply unit, preparation for redundancy for a second power supply unit (external)
Page 11
Description
2018-07-12 11
Model
Description
474­BODY6BP
Empty chassis for up to 6 boards, active backplane, 2x internal power supply unit (redundancy)
474­BODY6BPF
Empty chassis for up to 6 boards, active backplane, 2x internal power supply unit (redundancy) with connectors on rear side
474­BODY21/4U
Empty chassis for up to 21 boards, 1x internal power supply unit, preparation for redundancy for a second power supply unit (internal)
3.3.3 KVM Extender Modules
Model
Description
L488-BIPEx
Single-Head IP CPU extender module for 1x Single Link (up to 1920x1200), 2x USB-HID and 2x USB 2.0 embedded
L488-BIPExR
Single-Head IP CPU extender module for 1x HDMI Single Link (up to 1920x1200) with 2x USB-HID, USB
2.0 embedded and redundant connector for interconnect cables
Pos: 7 /806-IHSE/Beschreibung/Überwachungsmodule/474-xx @ 14\mod_1415202166328_6.doc @ 157997 @ 3 @ 1
3.3.4 Monitoring Modules
Model
Description
474-SNMP
SNMP module for monitoring of extenders in the chassis 474-BODY6BP/F and 474-BODY21
Pos: 8 /806-IHSE/Beschreibung/Einbauoptionen/474-xx @ 6\mod_1304580008551_6.doc @ 50839 @ 2 @ 1
Page 12
Draco vario IP CPU KVM KVM Extender
12 2018-07-12
3.4 Accessories Upgrade Kits
Model
Description
474-2RMK
19"/1U rack mount kit for 2-fold chassis
474­2NRMK
19"/1U rack mount kit for 2-fold chassis with internal PSU 474-4RMK
19"/1U rack mount kit for 4-fold chassis
474-6RMK
19"/1U rack mount kit for 6-fold chassis
474­VPLATE
Fastening strips for screw or snap on for 2-, 4- and 6-fold chassis
474­BRACKET
Mounting bracket with screws for 2-, 4- and 6-fold chassis
474­OPTRED
Retrofitting for redundant power supply option (without power supply) for 2- and 4-fold chassis
474-PSU2
Power supply for 2-fold chassis (spare or redundancy)
474-PSU4
Power supply for 4-fold chassis (spare or redundancy)
474-PSU6
Power supply for 6-fold chassis (spare or redundancy)
474-PSU21
Power supply for 6-fold-chassis (spare or redundancy)
474-BLND1
Blind plate 3U/4HP for 2-, 4- and 6-fold chassis
474-BLND2
Blind plate 3U/8HP for 2-, 4- and 6-fold chassis
474-6FAN
Fan option for chassis 474-BODY6BP/F
KVM Extenders and the power supply units can get warm and must not be installed in closed rooms with no air circulation. For rack-mount installations, at least 0.5 U (height unit) is required above the KVM Extender for ventilation.
Pos: 9 /806-IHSE/Beschreibung/Zubehör/481-xx @ 9\mod_1367826991670_6.doc @ 71673 @ 2 @ 1
Page 13
Description
2018-07-12 13
3.5 Accessories
Model
Description
026-2A
Serial cable 1.8 m (RS232)
247-U1
USB cable 1.8 m (Type A to B)
260-5G
International power supply unit 100...240VAC / 5VDC / 3 A
260-5U
International power supply unit 100...240VAC / 5VDC / 4 A
436-AA
VGA cable 1.8 m (VGA to DVI-I)
436-HD
HDMI cable 1.8 m (DVI-D)
436-DVHD
Adapter DVI-D male to HDMI female
445-2H
DVI-D splitter cable
455-CK
Stereo jack cable 1.6 m (3.5 mm Stereo)
455-CR
RCA cable 2.5 m (Cinch male connector)
455-CT
TOSLINK cable 1.8 m (F05 male connector)
455-CX
Mini-XLR cable 1.8 m (3 pole)
474­IECLOCK
IEC connection cable for power supply lockable
Pos: 10 /806-IHSE/Beschreibung/Geräteansichten/UEB_Geräteansichten @ 5\mod_1278573737808_6.doc @ 41654 @ 2 @ 1
Page 14
Draco vario IP CPU KVM KVM Extender
14 2018-07-12
3.6 Device Views
Pos: 11 /806-IHSE/Beschreibung/Geräteansichten/474-xx/2-fach Vario-Gehäuse 474-BODY2/2R @ 6\mod_1304580280566_6.doc @ 50858 @ 3 @ 1
3.6.1 2-fold Vario Chassis 474-BODY2/2R
CPU and CON Unit
Rear View
1 Slot for modules #1 2 Connect to 5VDC power supply (standard) 3 Slot for modules #2 4 Connect to 5VDC power supply (redundancy, optional)
Pos: 12 /806-IHSE/Beschreibung/Geräteansichten/474-xx/2-fach Vario-Gehäuse 474-BODY2N @ 8\mod_1348578478411_6.doc @ 69380 @ 3 @ 1
3.6.2 2-fold Vario Chassis 474-BODY2N
CPU and CON Unit
Rear View
1 Slot for modules #1 2 Connect to power supply (standard) 3 Slot for modules #2 4 Connect to 5VDC power supply (redundancy)
The 2-fold vario chassis with an internal power supply is not equipped with a fuse on its primary side. Therefore the protection against excessive currents has to be provided by the electrical installation of the building.
Pos: 13 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1
Page 15
Description
2018-07-12 15
Pos: 14 /806-IHSE/Beschreibung/Geräteansichten/474-xx/4-fach Vario-Gehäuse 474-BODY4/4R @ 6\mod_1304580359098_6.doc @ 50876 @ 3 @ 1
3.6.3 4-fold Vario Chassis 474-BODY4/4R
CPU and CON Unit
Rear View
1 Slot for modules #3 2 Slot for modules #1 3 Connect to 5VDC power supply (standard) 4 Slot for modules #4 5 Slot for modules #2 6 Connect to 5VDC power supply (redundancy, optional)
For operation with three KVM Extender CON modules and a USB 2.0 CON module in a 4-fold vario chassis, two power supplies are necessary. In this case, redundancy is inapplicable.
Pos: 15 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1
Page 16
Draco vario IP CPU KVM KVM Extender
16 2018-07-12
Pos: 16 /806-IHSE/Beschreibung/Geräteansichten/474-xx/6-fach Vario-Gehäuse 474-BODY6R @ 6\mod_1304580442488_6.doc @ 50894 @ 3 @ 1
3.6.4 6-fold Vario Chassis 474-BODY6R
CPU and CON Unit
Rear View
1 Slot for modules #5 2 Slot for modules #3 3 Slot for modules #1 4 Connect to power supply (standard) 5 Connect to 5VDC power supply (standard) 6 Slot for modules #6 7 Slot for modules #4 8 Slot for modules #2
For operation with KVM Extender modules in a 6-fold vario chassis, two power supplies are necessary. In this case, redundancy is inapplicable.
The 6-fold vario chassis is not equipped with a fuse on its primary side. Therefore the protection against excessive currents has to be provided by the electrical installation of the building.
Pos: 17 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1
Page 17
Description
2018-07-12 17
Pos: 18 /806-IHSE/Beschreibung/Geräteansichten/481-xx/6-fach Vario-Gehäuse 474-BODY6BP @ 9\mod_1367827188730_6.doc @ 71694 @ 3 @ 1
3.6.5 6-fold Vario Chassis 474-BODY6BP
CPU and CON Unit
Front View
1 Connect to power supply 1 2 Connect to power supply 2 (redundancy) 3 Grounding
Rear View
1 Slot for modules #5 2 Slot for modules #3 3 Slot for modules #1 4 Slot for modules #6 5 Slot for modules #4 6 Slot for modules #2
Pos: 19 /806-IHSE/Beschreibung/Geräteansichten/474-xx/6-fach Vario-Gehäuse 474-BODY6BPF @ 11\mod_1392644763729_6.doc @ 132650 @ 3 @ 1
Page 18
Draco vario IP CPU KVM KVM Extender
18 2018-07-12
3.6.6 6-fold Vario Chassis 474-BODY6BPF
CPU and CON Unit
Rear View
1 Slot for modules #5 2 Slot for modules #3 3 Slot for modules #1 4 Connect to power supply 1 5 Connect to power supply 2 (redundancy) 6 Slot for modules #6 7 Slot for modules #4 8 Slot for modules #2
Pos: 20 /806-IHSE/Beschreibung/Geräteansichten/474-xx/21-fach Vario-Gehäuse 474-BODY21R @ 8\mod_1348579151346_6.doc @ 69400 @ 3 @ 1
Page 19
Description
2018-07-12 19
3.6.7 21-fold Vario Chassis 474-BODY21R
CPU and CON Unit
Rear View
1 Slots for modules #1 - #21
Front View
1 Connect to power supply 2 2 Locking for power supply 2 (redundancy) 3 Locking for power supply 1 (standard) 4 Connect to power supply 1
Pos: 21 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1 Pos: 22 /806-IHSE/Beschreibung/Geräteansichten/481-xx/Typ L- / R481-BHHC @ 9\mod_1367828248520_6.doc @ 71714 @ 3 @ 4
Page 20
Draco vario IP CPU KVM KVM Extender
20 2018-07-12
3.6.8 Model L488-BIPEC / -BIPECR
CPU Module
CPU Module
Rear View
Rear View
1 Service port 2 Connect to interconnect cable 3 To CPU: TCP/IP network
1 Service port 2 Connect to interconnect cable 1 3 Connect to interconnect cable 2 4 To CPU: TCP/IP network
Pos: 23 /806-IHSE/Beschreibung/Geräteansichten/481-xx/Typ L- / R481-BHHCR @ 9\mod_1373967661662_6.doc @ 77531 @ 3 @ 4
3.6.9 Model L488-BIPES / -BIPESR
CPU Module
CPU Module
Rear View
Rear View
1 Service port 2 Connect to interconnect cable 1 3 Connect to interconnect cable 2 4 To CPU: TCP/IP network
1 Service port 2 Connect to interconnect cable 1 3 Connect to interconnect cable 2 4 To CPU: TCP/IP network
Pos: 24 /806-IHSE/Beschreibung/Geräteansichten/481-xx/Typ L481-BHHCL @ 9\mod_1367828402398_6.doc @ 71734 @ 3 @ 1
Pos: 54 /806-IHSE/Beschreibung/Geräteansichten/483-xx/Typ 474-SNMP @ 13\mod_1412172938631_6.doc @ 151898 @ 3 @ 1
Page 21
Description
2018-07-12 21
3.6.10 Model 474-SNMP
Control Unit
Rear View
1 Connect to serial (D-Sub 9) 2 Connect to network (RJ45)
The 474-SNMP module can be only used with the chassis 474­BODY6BP/F and 474-BODY21 with a production date later than March 2014.
-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1 Pos: 56 /806-IHSE/Beschreibung/Diagnose LEDs/UEB_Diagnose_LEDs @ 6\mod_1304584004723_6.doc @ 51146 @ 2 @ 1
Page 22
Draco vario IP CPU KVM KVM Extender
22 2018-07-12
3.7 Status LEDs
Pos: 57 /806-IHSE/Beschreibung/Diagnose LEDs/481-xx/Diagnose KVM-Extender-Modul @ 9\mod_1367834480876_6.doc @ 71875 @ 3 @ 4
3.7.1 Status KVM Extender Module
The KVM Extender module is fitted with a multi color LED on both sides for overall status indication and with two further LEDs on the back side for indication of the connection status.
CPU Module
Rear View
Rear View
LED 1-4: Connection Status Link 1 & 2
Pos.
LED
Status
Description
1, 3
Failure LED
(red) Off
Connection available
On or Flashing
Connection failure (flashing for about 20 s following a connection failure)
2, 4
Status LED
(green)
Flashing
No connection via interconnect cable
On
Connection available
LED 5 & 6: USB and Video Status
LED color
Description
Red
Device ready
Violet
Connection and USB signal (interconnect) available
Green
Connection and video signal available
Light Blue
Connection, USB and video signal available (operating status)
Page 23
Description
2018-07-12 23
LED 7: Compute Module Status
LED color
Description
Red
Compute module available, kernel and application not available
Green
Kernel available, application not available
Light blue
Kernel and application available
LED 8: USB 2.0 embedded Status
LED color
Description
Green
Active USB 2.0 embedded link to CON Unit
Light Blue/green flashing
USB 2.0 host detected Light blue
flashing
USB 2.0 host and devices detected
LED 9 & 10: Connection Status TCP/IP (network)
Pos.
LED
Status
Description
9
Traffic LED
(green)
Off
No network traffic
Flashing
Network traffic available
10
Link LED
(green)
Off or flashing
No network connection available On
Network connection available
Page 24
Draco vario IP CPU KVM KVM Extender
24 2018-07-12
3.7.2 Status Monitoring Module SNMP
The monitoring module SNMP is fitted with a multi color LED on both sides for overall status indication and with two further LEDs for indication of the network status:
Rear View
Status LEDs of the SNMP board
Pos.
LED
Status
Description
1
Status 1
White
SNMP board is in registration process
Blue flashing
Registration of the SNMP board has started
Red flashing
Registration in progress
Green flashing
Operating condition Green
SNMP board de-registered
4 Status 2
White
SNMP board is in registration process
Status
Description
White
SNMP board is in registration process
Due to variations in LED type "white" might also appear as light purple or light blue.
Status LEDs of the network port
Pos.
LED
Status
Description
2
Link status
(orange) Off
Port not activated
Flashing
Port activated, no connection via network cable
3
Link status
(green) Off
Port not activated
Flashing
Port activated, no connection via network cable
Pos: 64 /806-IHSE/Installation/UEB_Installation @ 5\mod_1278574971589_6.doc @ 41768 @ 1 @ 1
Page 25
Installation
2018-07-12 25
4 Installation
Pos: 65 /806-IHSE/Installation/Lieferumfang prüfen/481-xx @ 9\mod_1367838010040_6.doc @ 71895 @ 2 @ 1
4.1 Package Contents
Your extender package contains the following items: KVM Extender:
KVM Extender (CPU Unit)  Draco vario chassis incl. power supply  1x (redundancy 2x) country-specific power cord  Quick Setup
If anything is missing, contact your dealer.
Pos: 67 /806-IHSE/Installation/System anschließen/474-xx @ 6\mod_1304584542160_6.doc @ 51273 @ 233 @ 1
Page 26
Draco vario IP CPU KVM KVM Extender
26 2018-07-12
4.2 System Setup
First time users are recommended to setup the system with the CPU Unit and the CON Unit in the same room as a test setup. This will allow you to identify and solve any cabling problems, and experiment with your system more conveniently.
Please verify that interconnect cables, interfaces, and handling of the
devices comply with the requirements (see Chapter 7, Page 40).
4.2.1 KVM Extender Setup
1. Switch off all devices.
CPU Unit Installation
2. Connect the TCP/IP network cable to the CPU Unit. Please ensure the cables are not strained.
3. Connect the CPU Unit to the interconnect cable(s).
4. Connect the 5VDC power supply to the CPU Unit.
5. Power up the system.
To power up the system, the following sequence is recommended: Monitor – CON Unit – CPU Unit – source.
Pos: 68 /806-IHSE/Installation/Installationsbeispiele/UEB_Installationsbeispiele @ 5\mod_1278581564870_6.doc @ 42759 @ 2 @ 1
Page 27
Installation
2018-07-12 27
4.3 Example Applications
This section illustrates a typical installation of IP CPU KVM extenders:
IP CPU KVM extender installation example
Pos: 70 /806-IHSE/Installation/Betriebsmodi/481-xx @ 9\mod_1373975439223_6.doc @ 77658 @ 2 @ 4
Page 28
Draco vario IP CPU KVM KVM Extender
28 2018-07-12
5 Configuration
Pos: 73 /806-IHSE/Konfiguration/Übertragungsparameter/477-xx @ 5\mod_1278937002401_6.doc @ 43075 @ 2 @ 1
5.1 Transmission Parameters
The device operates with a proprietary compression method. In default configuration, the device adapts dynamically to monitor
resolution and image content. This configuration is suitable for almost all conditions and should only be modified if image quality is not fully satisfactory.
In exceptional cases the displayed video image may exhibit "frame dropping" (loss of single pictures) or color effects.
Pos: 74 /806-IHSE/Konfiguration/DDC-Einstellungen/477-xx @ 5\mod_1278937107542_6.doc @ 43093 @ 2 @ 1
5.2 DDC Settings
By default, the device transmits the factory preset DDC information to the CPU. This information is suitable in most cases.
Downloading of the DDC information of the console monitor can be performed during normal operation (see Chapter 6.1, Page 38).
For special requirements, DDC information can be retrieved and uploaded as a binary file to both the CPU Unit and the CON Unit.
Connect your computer with a USB mini cable to the service port of the CPU Unit or CON Unit.
The data area of the unit is now accessible as a flash drive "Extender".
Uploading DDC Information
Copy the binary file containing your specific DDC information to the flash drive of the CPU Unit or CON Unit.
The current DDC information is replaced.
Retrieving DDC Information
Copy the file "DDC-EDID.bin" on the flash drive of the CPU Unit to your computer.
To open the binary file, you have to install a suitable software, e.g. WinDDCwrite, on your computer. Contact your dealer for this purpose.
Reset to Factory DDC Information
Delete the file called "DDC-EDID.bin" on the flash drive of the CPU Unit. By deleting this file, the factory DDC Information is restored.
Page 29
Configuration
2018-07-12 29
Pos: 75 /806-IHSE/Konfiguration/Kommando-Modus/474-xx @ 6\mod_1304585026863_6.doc @ 51291 @ 2 @ 1
5.3 Command Mode
During normal use, the console keyboard functions in the usual manner. However, for all KVM Extenders with USB-HID support, you can set the keyboard into a Command Mode by using a specific 'Hot Key' sequence. While in Command Mode, several functions are performed via keyboard commands. To exit Command Mode, press <Esc>.
While in Command Mode, the Shift and Scroll LEDs on the console keyboard will flash.
In Command Mode normal keyboard and mouse operation will cease. Only selected keyboard commands are available.
If no keyboard command is executed within 10 s after activating Command Mode, it will be automatically deactivated.
The following table lists the keyboard commands to enter and to exit Command Mode and to change the 'Hot Key' sequence:
Function
Keyboard Command
Enter Command Mode (default)
2x <Left Shift> / ('Hot Key')
Exit Command Mode
<Esc>
Change 'Hot Key' sequence
<current 'Hot Key'>, <c>, <new 'Hot Key' code>, <Enter> Until 2011-30-09: <Left Ctrl> + <Left Shift> + <c>,
<'Hot Key' Code>, <Enter>
<Key> + <Key> Press keys simultaneously <Key>, <Key> Press keys successively 2x <Key> Press key quickly, twice in a row
(similar to a mouse double-click)
Page 30
Draco vario IP CPU KVM KVM Extender
30 2018-07-12
The 'Hot Key' sequence to enter Command Mode can be changed. The following table lists the 'Hot Key' Codes for the available key sequences:
'Hot Key' Code
'Hot Key'
0
Freely selectable (from 2012-01-12)
2
2x <Scroll>
3
2x <Left Shift>
4
2x <Left Ctrl>
5
2x <Left Alt>
6
2x <Right Shift>
7
2x <Right Ctrl>
8
2x <Right Alt>
Set freely selectable 'Hot Key' (exemplary)
In order to set a freely selectable 'Hot Key' (e.g. 2x <Space>), use the following keyboard sequence:
<current 'Hot Key'>, <c>, <0>, <Space>, <Enter>
Reset 'Hot Key'
In order to set a 'Hot Key' back to default settings of the extender, press the key combination <Right Shift> + <Del> within 5 s after plugging in a keyboard.
Pos: 76 /806-IHSE/Konfiguration/USB-HID-Ghosting/K477_USB-HID-Ghosting @ 9\mod_1362404683851_6.doc @ 71192 @ 2 @ 1
Page 31
Configuration
2018-07-12 31
5.4 USB-HID Ghosting
This function allows specific keyboard and mice descriptors (device descriptions) to be permanently stored in the CPU unit. This eliminates the need to register and deregister the keyboard and mouse on an operating system each time there is a shared use of a source (computer, CPU) by two or more consoles within a KVM matrix.
The following table lists the keyboard commands for the configuration of USB-HID Ghosting:
Function
Keyboard Command
Writes the device descriptions of the input devices connected to the CON Unit into the CPU Unit. Activating the emulation in the CPU Unit.
<'Hot Key'>, <h>, <w>, <Enter> Activates the emulation of already
stored device descriptions in the CPU Unit
<'Hot Key'>, <h>, <e>, <Enter>
Deactivates the emulation of active device descriptions in the CPU Unit. The input devices connected to the CON Unit will be now passed transparently to the source (computer, CPU).
<'Hot Key', <h>, <d>, <Enter>
Deactivates the emulation of active device descriptions in the CPU Unit. Deletes the descriptions out of the CPU Unit. The input devices connected to the CON Unit will be now passed transparently to the source (computer, CPU).
<'Hot Key', <h>, <r>, <Enter>
When using a USB combo device as a USB-HID input device, switching to a CPU Unit with activated USB-HID Ghosting may cause limited functionality.
Pos: 77 /806-IHSE/Konfiguration/474_Konfigurationsdatei/474-xx 481-xx 482-xx 483-xx @ 7\mod_1331801555639_6.doc @ 58172 @ 2333 @ 1
Page 32
Draco vario IP CPU KVM KVM Extender
32 2018-07-12
5.5 Configuration File
The KVM Extender contains a configuration file (Config.txt) to set specific parameters and to read out device and video information. You can find it on the flash drive of the KVM Extender. The flash drive can be opened by a mini USB connection to a computer.
The configuration file can be edited with all common text editors.
After setting a parameter, the KVM Extender needs to be restarted.
To ensure correct identification and acceptance of the parameters, the start command #CFG has to be written into the first line of the Config.txt file.
5.5.1 Parameters for CPU Units
You can write the following parameters into the configuration file of a CPU Unit.
DDC-Management
Parameter
Function
ENAHPDET
Enable hotplug switch for K238-5x series
LOCKEDID
Activate DDC write protection
Digital-Audio
Parameter
Function
SRC32000
Activate sample rate conversion, sample rate 32 kHz (only with digital audio upgrade module)
SRC44100
Activate sample rate conversion, sample rate 44,1 kHz (only with digital audio upgrade module)
SRC48000
Activate sample rate conversion, sample rate 48 kHz (only with digital audio upgrade module)
SRC96000
Activate sample rate conversion, sample rate 96 kHz (only with digital audio upgrade module)
SRC_NONE
Deactivate sample rate conversion (only with digital audio upgrade module)
Page 33
Configuration
2018-07-12 33
Compression
Parameter
Function
MEDCPRATE
Activate medium compression rate
MINCPRATE
Activate low compression rate
MAXCPRATE
Activate high compression rate
ENADITHER
Activate dithering filter for Mac OS systems
Shared Operation
Parameter
Function
RELEASETIME=n
Release timer n = 0...9 seconds for Mouse and Keyboard Connect, without parameter = 2 seconds
General Settings
Parameter
Function
DISPLAY2
Show video channel 2 per default after switching on the respective Dual-Head unit (482 series only)
Page 34
Draco vario IP CPU KVM KVM Extender
34 2018-07-12
5.6 Remote Access Configuration
The IP CPU KVM extender requires an individual configuration to be able connecting to a source /computer, CPU) via TCP/IP network. The configuration must be performed via Draco tera KVM matrix and consists of the of the IP Session configuration, the IP CPU EXT Unit configuration and the assignment of the IP Session to the IP CPU Device.
The minimum firmware requirement for the Draco tera KVM matrix is version V03.06 and version 3.6.0.0 for the Java tool (Tera tool).
You have the following option to perform the configuration:
In order to configure the IP CPU extender, proceed as follows.
IP Session Configuration
The configuration of the IP session includes the relevant settings for the remote connections.
1. Connect to the Draco tera KVM matrix via Java tool.
2. Select Definition > CPU Devices in the task area of the Java tool and open the tab IP Session Config.
Page 35
Configuration
2018-07-12 35
Menu Extender & Devices – CPU Devices
3. Press the button New Config. A new IP Session Config will be created. Generally, an IP Session Config can be used for multiple IP CPU KVM extenders.
4. Name the IP Session Config in the field Name.
5. Select the Type of remote access in the corresponding field.
6. Insert a User Name and Password for the IP session user. The user can be a local user or part of a domain.
7. If the user is a domain user, enter the Domain name into the corresponding field.
8. If the network ports of the remote access type are not the standard ones (e.g. RDP port: 3389), enter the respective port into the field Port.
9. Select the resolution of the remote connection (default: 1920x1080).
10. If the remote connection should be performed in Full Screen, check the corresponding check box.
11. If you want to transmit digital HDMI audio, check the box Sound.
12. Press the button Apply to confirm your configuration settings.
Any IP session config can be assigned to multiple IP CPU Devices at the same time.
IP CPU EXT Unit Configuration
The configuration of the IP CPU EXT Unit refers to the the respective network settings of the IP CPU extender (compute module).
1. Ensure that the IP CPU extender is physically connected to the Draco tera matrix and switched on. It can take up to 30 sec. until the it is finally registered at the KVM matrix.
2. Select Definition > EXT Units in the main menu of the Java tool.
3. Select the IP CPU EXT Unit to be configured in the EXT Units list and open the tab Server Settings.
Page 36
Draco vario IP CPU KVM KVM Extender
36 2018-07-12
Menu Extender & Devices – EXT Units
4. Press the button Read to show the current server settings of the IP CPU EXT Unit.
5. Enter a Hostname into the corresponding field.
6. If you want to use a DHCP server, check the box DHCP.
7. Configure the remaining server settings. The setting DNS Server is optional, all other settings are mandatory (Address, Subnet Mask,
Gateway, NTP server, TimeZone and Keyboard Layout)
Direct IP Session Assignment
This type of configuration allows the exclusive access of one IP session only. In order to assign a single IP session to an IP CPU Device, proceed as follows:
1. Select Definition > CPU Devices in the main menu of the Java tool and open the tab CPU.
2. Select the IP CPU Device to be configured in the list of Devices.
3. Select an IP Session Config in the field IP Direct Config. The selected IP Session Config will be directly assigned to the IP CPU Device.
4. Repeat the assignment for each IP CPU Device individually.
Page 37
Configuration
2018-07-12 37
5. The IP CPU Devices are now configured and so the IP CPU KVM extenders can be used.
Assignment of multiple IP session configs
This type of configuration allows the parallel access of multiple different IP sessions. In order to assign multiple IP session configs to an IP CPU Device, proceed as follows:
1. Select Definition > CPU Devices in the main menu of the Java tool and open the tab CPU.
2. Press the Button Configure IP CPU on the bottom of the working area. A pop-up window will appear.
Menu Configure IP CPU
3. Follow the instructions of the configuration wizard and perform the assignment accordingly.
4. After finishing the configuration wizard, the IP CPU Device can be used.
Page 38
Draco vario IP CPU KVM KVM Extender
38 2018-07-12
6 Operation
Pos: 79 /806-IHSE/Betrieb/Laden von DDC-Informationen/477-xx @ 5\mod_1278937455136_6.doc @ 43130 @ 2 @ 1
6.1 Download of DDC Information
By default, data from the internal DDC list is reported to the source (computer, CPU). If these are not optimal settings for the display device, the DDC information of the console monitor can be downloaded and stored internally. The devices have to be configured accordingly (see Chapter 5.2, Page 28).
On all KVM Extenders with USB-HID support, the user can load the DDC information of the console monitor via keyboard command under operating conditions.
1. Enter Command Mode with the 'Hot Key' (see Chapter 5.2, Page 28).
2. Press the <a> key to download the DDC information of the console monitor.
The screen will go black for a short time. At the same time Command Mode is closed and the keyboard LEDs
return to previous status.
3. Restart the corresponding source (computer, CPU). The video mode has been readjusted. Screen quality should be
optimal. The CPU should now show the console monitor as the current screen, together with the available video resolutions.
The DDC information of the console monitor was loaded once. Reloading is possible by repeating the operation.
Pos: 80 /806-IHSE/Betrieb/Parallelbetrieb/474-xx_Parallelbedienung redundanter CPU Units @ 9\mod_1373962269987_6.doc @ 77387 @ 2 @ 1
6.2 Shared Operation of redundant CPU Units
CPU Units with a redundant connector for interconnect cables offer the possibility for a competing control by two connected CON Units.
Taking over control is performed using a keyboard and/or mouse. The release timer function determines the release time of the input devices at one of the CON Units after that control can be taken over from the second CON Unit.
Page 39
Operation
2018-07-12 39
In order to configure a redundant CPU Unit for the operation with two competing CON Units, proceed as follows:
1. Connect a redundant CPU Unit to any source (computer, CPU) by using a mini USB connection.
2. Open the file "Config.txt" that is located on the appearing flash drive of the extender.
3. Activate the release timer by writing the parameter RELEASETIME=n into the second line. The variable "n" defines the time in seconds and has to be replaced by the numbers 0 to 9 (e.g. RELEASETIME=5). If this parameter is not activated at all, the release time is set to 2 seconds by default. The parameter RELEASETIME=X deactivates the shared operation.
4. Save your changes.
5. Reboot the CPU Unit.
Example View – Config.txt
When using redundant CPU Units in combination with a KVM matrix, the function of competing control will be automatically deactivated in the extender and will have to be performed by the KVM matrix.
Pos: 81 /806-IHSE/Betrieb/KVM-Schaltung/481-xx Lokale KVM-Umschaltung @ 9\mod_1369724748986_6.doc @ 72081 @ 2 @ 1
Page 40
Draco vario IP CPU KVM KVM Extender
40 2018-07-12
7 Specifications
Pos: 83 /806-IHSE/Technische Daten/Schnittstellen/UEB_Schnittstellen @ 5\mod_1278578201870_6.doc @ 42114 @ 2 @ 1
7.1 Interfaces
Pos: 84 /806-IHSE/Technische Daten/Schnittstellen/HDMI-Single-Link @ 9\mod_1367840986696_6.doc @ 71916 @ 3 @ 1
7.1.1 Single Link
Video
The audio / video interface can transmit monitor resolutions such as 1920x1200@60Hz, Full HD (1080p) or 2K HD (up to 2048x1152). Data rate is limited to 165 MPixel/s and 8 bit.
Audio
Various digital audio formats can be transmitted through the interface.
Standards
Stereo Linear Pulse Code Modulation (LPCM), DTS, DTS-HD (5.1), Dolby Digital, Dolby Digital Plus (5.1)
Bit Depth
16 to 24 bit
Sample Rate
32 to 192 kHz
Pos: 85 /806-IHSE/Technische Daten/Schnittstellen/USB-HID @ 5\mod_1278578292214_6.doc @ 42150 @ 3 @ 1
7.1.2 USB-HID
Our devices with USB-HID interface support a maximum of two devices with USB-HID protocol. Each USB-HID port provides a maximum current of 100 mA.
Keyboard
Compatible with most USB keyboards. Certain keyboards with additional functions may require custom firmware to operate. Keyboards with an integral USB Hub (Mac keyboards e.g.) are also supported.
Mouse
Compatible with most 2-button, 3-button and scroll mice.
Other USB-HID devices
The proprietary USB emulation also supports certain other USB-HID devices, such as specific touch screens, graphic tablets, barcode
Page 41
Specifications
2018-07-12 41
scanners or special keyboards. Support cannot be guaranteed, however, for every USB-HID device.
Only two USB-HID devices are supported concurrently, such as keyboard and mouse or keyboard and touch screen. A hub is allowed, but it does not increase the number of HID devices allowed.
To support other USB 'non-HID' devices, such as scanners, web cams or memory devices, choose our devices with transparent USB support.
Pos: 86 /806-IHSE/Technische Daten/Schnittstellen/PS/2 @ 9\mod_1362475419529_6.doc @ 71291 @ 3 @ 1
Pos: 87 /806-IHSE/Technische Daten/Schnittstellen/474-xx (USB 2.0 (transparent)) @ 7\mod_1331801757497_6.doc @ 58190 @ 3 @ 1
7.1.3 USB 2.0 (transparent)
KVM Extender models with transparent USB 2.0 support allow the connection of all types of USB 2.0 devices (without restriction). USB 2.0 data transfer is supported, depending on the upgrade module, with USB high speed (max. 480 Mbit/s) or USB embedded (max. 36/100/480 Mbits, depending on extender type).
Each USB embedded port provides a maximum current of 500 mA (high power). When using a USB high speed interface with 4 USB ports, respectively 2 connectors provides a maximum of 500 mA (high power) and 2 connectors a maximum of 100 mA.
Pos: 88 /806-IHSE/Technische Daten/Schnittstellen/RJ45 (Gerätekommunikation) @ 5\mod_1278578339308_6.doc @ 42186 @ 3 @ 1
7.1.4 RJ45 (Interconnect)
Communication between Cat X devices requires a 1000BASE-T connection.
Connector wiring must comply with EIA/TIA-568-B (1000BASE-T), with RJ45 connectors at both ends. All four cable wire pairs are used.
Pos: 89 /806-IHSE/Technische Daten/Schnittstellen/Glasfaser SFP Typ LC @ 5\mod_1278937700855_6.doc @ 43149 @ 3 @ 1
7.1.5 Fiber SFP Type LC (Interconnect)
Communication of fiber devices is performed via Gigabit SFPs that are connected to suitable fibers fitted with connectors type LC ().
The correct function of the device can only be guaranteed with SFPs provided by the manufacturer.
SFP modules can be damaged by electrostatic discharge (ESD). Please consider ESD handling specifications.
Pos: 90 /806-IHSE/Technische Daten/Schnittstellen/Serielle Schnittstelle @ 5\mod_1291127444390_6.doc @ 44828 @ 3 @ 1 Pos: 93 /806-IHSE/Technische Daten/Schnittstellen/477-xx (Digital Audio-Schnittstellen) @ 6\mod_1304585776832_6.doc @ 51309 @ 3 @ 1
Page 42
Draco vario IP CPU KVM KVM Extender
42 2018-07-12
7.1.6 RJ45 (Network)
The communication of the Cat X devices requires a 100BASE-T connection.
The cabling must be done according to EIA/TIA-568-B (100BASE-T) with RJ45 connectors at both ends. All four wire pairs are used in both directions. The cabling is suitable for a full duplex operation. For the cable connection to a source (computer, CPU), a crossed network cable (cross cable) must be used.
Pos: 92 /806-IHSE/Technische Daten/Schnittstellen/Serielle Schnittstelle RS422 @ 9\mod_1362475591209_6.doc @ 71309 @ 3 @ 1
Page 43
Specifications
2018-07-12 43
7.2 Interconnect Cable
Pos: 95 /806-IHSE/Technische Daten/Verbindungskabel/Verbindungskabel (Cat X) @ 5\mod_1278578406026_6.doc @ 42205 @ 3 @ 1
7.2.1 Cat X
A point-to-point connection is required. Operation with several patch fields is possible. Routing over an active network component, such as an Ethernet Hub, Router or Matrix, is not allowed.
Avoid routing Cat X cables along power cables.
To maintain regulatory EMC compliance, correctly installed shielded Cat X cable must be used throughout the interconnection link.
To maintain regulatory EMC compliance, all Cat X cables need to carry ferrites on both cable ends close to the device.
Type of Interconnect Cable
The KVM Extender requires interconnect cabling specified for Gigabit Ethernet (1000BASE-T). The use of solid-core (AWG24), shielded, Cat 5e (or better) is recommended.
Cat X Solid-Core Cable AWG24
S/UTP (Cat 5e) cable according to EIA/TIA­568-B. Four pairs of wires AWG24. Connection according to EIA/TIA-568-B (1000BASE-T).
Cat X Patch Cable AWG26/8
S/UTP (Cat 5e) cable according to EIA/TIA­568-B. Four pairs of wires AWG26/8. Connection according to EIA/TIA-568-B (1000BASE-T).
The use of flexible cables (patch cables) type AWG26/8 is possible, however the maximum possible extension distance is halved.
Pos: 96 /806-IHSE/Technische Daten/Verbindungskabel/Verbindungskabel (Cat X)_Kabellänge 477-xx @ 5\mod_1278937761105_6.doc @ 43167 @ @ 1
Maximum Acceptable Cable Length
Cat X Installation Cable AWG24
140 m (400 ft)
Cat X Patch Cable AWG26/8
70 m (200 ft)
Pos: 97 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1
Page 44
Draco vario IP CPU KVM KVM Extender
44 2018-07-12
Pos: 98 /806-IHSE/Technische Daten/Verbindungskabel/Verbindungskabel (LWL) @ 5\mod_1278937967667_6.doc @ 43186 @ 3 @ 1
7.2.2 Fiber
A point-to-point connection is necessary. Operation with multiple patch panels is allowed. Routing over active network components, such as Ethernet Hubs, Switches or Routers, is not allowed.
Type of Interconnect Cable
(Cable notations according to VDE)
Type of cable
Specifications
Single-mode 9μm
Two fibers 9μm I-V(ZN)H 2E9 (in-house patch cable)  I-V(ZN)HH 2E9 (in-house breakout cable)  I/AD(ZN)H 4E9 (in-house or outdoor
breakout cable, resistant)
A/DQ(ZN)B2Y 4G9 (outdoor cable, with
protection against rodents)
Multi-mode 50μm
Two fibers 50μm I-V(ZN)H 2G50 (in-house patch cable)  I/AD(ZN)H 4G50 (in-house or outdoor
breakout cable, resistant)
Multi-mode 62.5μm
Two fibers 62.5μm I-V(ZN)HH 2G62.5 (in-house breakout
cable)
A/DQ(ZN)B2Y 4G62.5 (outdoor cable,
with protection against rodents)
Maximum Acceptable Cable Length
Type of cable
Maximum Acceptable Cable Length
Single-mode 9μm
10,000 m (32,800 ft)
Single-mode 9μm XV
5,000 m (16,400 ft)
Multi-mode 50μm (OM3)
1,000 m (3,280 ft)
Multi-mode 50μm
400 m (1,300 ft)
Multi-mode 62.5μm
200 m (650 ft)
If you use single-mode SFPs with multi-mode fibers, you normally can double the maximum acceptable cable length.
Pos: 99 /806-IHSE/Technische Daten/Verbindungskabel/Verbindungskabel (LWL)_Steckverbinder 477-xx @ 5\mod_1278954447542_6.doc @ 43740 @ @ 1
Type of Connector
Connector
LC Connector
Pos: 100 /806-IHSE/Technische Daten/Unterstützte Peripherie/UEB_Unterstützte Peripherie @ 5\mod_1278578478761_6.doc @ 42242 @ 2 @ 1
Page 45
Specifications
2018-07-12 45
7.3 Supported Peripherals
Pos: 101 /806-IHSE/Technische Daten/Unterstützte Peripherie/USB-HID-Geräte @ 5\mod_1278578523558_6.doc @ 42260 @ 3 @ 1
7.3.1 USB-HID Devices
The KVM Extender will support most USB-HID devices, including the vast majority of keyboards and mice currently on the market. Many other kinds of HID devices such as bar-code scanners and touch screens may also be compatible
It is not possible to guarantee support for all available USB-HID devices. In certain cases, custom firmware may be required.
USB-HID (and other) devices that are not supported as standard will normally operate with our devices featuring transparent USB support.
Please note that concurrent operation of more than two USB-HID devices is not possible even if you use a USB hub.
Pos: 102 /806-IHSE/Technische Daten/Unterstützte Peripherie/USB-2.0-Geräte @ 5\mod_1278578553933_6.doc @ 42278 @ 3 @ 1
7.3.2 USB 2.0 Devices
KVM Extender models featuring a transparent USB 2.0 connection use Extreme USB Technology from Icron Technologies.
This technology supports all types of USB 2.0 devices, however the manufacturer cannot guarantee compatibility with every device on the market. Please contact your dealer if any issues are found.
Page 46
Draco vario IP CPU KVM KVM Extender
46 2018-07-12
7.4 Supported Network Protocols
The KVM Extender supports various common network protocols for the TCP/IP connection between a source (computer, CPU) and the IP CPU KVM extender.
Remote Desktop Protocol (RDP)
Proprietary protocol (Microsoft) to connect to a source (computer, CPU) via network using RDP server software based on a graphical interface.
RemoteFX
Enhanced remote desktop protocol (Microsoft) to handle graphics­intensive applications.
Virtual Network Computing (VNC)
Platform-independent graphical desktop sharing system to remotely control a source (computer, CPU).
Secure Shell (SSH)
Cryptographic network protocol for operating network services securely over an unsecured network in a client-server architecture.
Pos: 103 /806-IHSE/Technische Daten/Pinbelegungen/UEB_Pinbelegungen @ 5\mod_127857868363
If you require the support of additional protocols, please contact your dealer.
6_6.doc @ 42315 @ 2 @ 1
Page 47
Specifications
2018-07-12 47
7.5 Connector Pinouts
Connector Mini USB Type B
Picture
Pin
Signal
Color
1
VCC (+5VDC)
Red
2
Data –
White
3
Data +
Green
4
n.c.
5
GND
Black
Pos: 109 /806-IHSE/Technische Daten/Pinbelegungen/RJ45 @ 5\mod_1278578820011_6.doc @ 42405 @ @ 1
RJ45 (interconnect)
Picture
Pin
Signal
Pin
Signal
1
D1+
5
D3–
2
D1–
6
D2–
3
D2+
7
D4+
4
D3+
8
D4–
Pos: 110 /806-IHSE/Technische Daten/Pinbelegungen/Glasfaser SFP Typ LC @ 5\mod
Fiber SFP Typ LC
Picture
Diode
Signal
1
Data OUT
2
Data IN
RJ45 (TCP/IP network)
Picture
Pin
Signal
Pin
Signal
1
D1+
5
n.c 2 D1–
6
D2–
3
D2+
7
n.c
4
n.c 8 n.c
Page 48
Draco vario IP CPU KVM KVM Extender
48 2018-07-12
Power Supply
Picture
Pin
Signal
Inside
VCC (+5VDC)
Outside
GND
Pos: 119 /806-IHSE/Technische Daten/Stromversorgung/481-xx @ 9\mod_1367841584586_6.doc @ 71953 @ 2 @ 1
7.6 Power Supply
AC Power Supply
Model
Max. Current
Max. Voltage
Frequency
474-BODY2N
700 mA max.
100-240 V
50/60 Hz
474-BODY6R
1,400 mA max.
100-240 V
47-63 Hz
474-BODY6BP
1,300 mA max.
100-240 V
50/60 Hz
474-BODY6BPF
1,300 mA max.
100-240 V
50/60 Hz
474-BODY21/4U
4,000 mA max.
2x 100-240 V
50/60 Hz
DC Power Supply
Model
Max. Current
Max. Voltage
474-BODY2/2R
3,000 mA
5 VDC
474-BODY2N
5,000 mA
5 VDC
474-BODY4/4R
5,000 mA
5 VDC
474-BODY6R
8,000 mA
5 VDC
Power Requirement
Power Requirement (per Unit)
KVM Extender:
Non-redundant devices: max. 1,400 mA  Redundancy devices: max. 1,650 mA
Pos: 120 /806-IHSE/Technische Daten/Einsatzbedingungen/ATB_Einsatzbedingungen @ 5\mod_1278578980026_6.doc @ 42480 @ 2 @ 1
Page 49
Specifications
2018-07-12 49
7.7 Environmental Conditions
Operating Temperature
41 to 113°F (5 to 45°C)
Storage Temperature
13 to 140°F (25 to 60°C)
Relative Humidity
Max. 80% non-condensing
Pos: 121 /806-IHSE/Technische Daten/Einsatzbedingungen/Zusatz Einsatzbedingungen 474/481/482/483 @ 15\mod_1446725775104_6.doc @ 164929 @ @ 1
Noise Emission
Sound Pressure Level (SPL)
max .21 dBA per fan (474-6FAN)
Heat Dissipation
Thermal output
Corresponds to power consumption in Watt (W) (see extender configurator on the website)
Pos: 122 /806-IHSE/Technische Daten/Abmessungen/474-xx @ 6\mod_1304586358176_6.doc @ 51345 @ 2 @ 1
7.8 Size
Devices in the 2-fold Vario Chassis 1
CPU Unit / CON Unit
145 x 147 x 41 mm (5.7" x 5.8" x 1.7")
Shipping Box
210 x 140 x 165 mm (8.3" x 5.5" x 6.5")
Devices in the 2-fold Vario Chassis 2
CPU Unit / CON Unit
221 x 147 x 41 mm (8.7" x 5.8" x 1.7")
Shipping Box
550 x 365 x 115 mm (21.7" x 14.4" x 4.5")
Devices in the 4-fold Vario Chassis
CPU Unit / CON Unit
293 x 147 x 41 mm (11.5" x 5.8" x 1.7")
Shipping Box
550 x 365 x 115 mm (21.7" x 14.4" x 4.5")
Devices in the 6-fold Vario Chassis 6R
CPU Unit / CON Unit
442 x 147 x 41 mm (17.4" x 5.8" x 1.7")
Shipping Box
760 x 365 x 115 mm (29.9" x 14.4" x 4.5")
Page 50
Draco vario IP CPU KVM KVM Extender
50 2018-07-12
Devices in the 6-fold Vario Chassis 6BP / 6BPF
CPU Unit / CON Unit
442 x 250 x 44 mm (17.4" x 9.8" x 1.7")
Shipping Box
550 x 372 x 155 mm (21.7" x 14.6" x 6.1")
Devices in the 21-fold Vario Chassis
CPU Unit / CON Unit
482 x 462 x 176 mm (19.0" x 18.2" x 6.9")
Shipping Box
645 x 574 x 368 mm (25.4" x 22.6" x 14.5")
Pos: 123 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1 Pos: 124 /806-IHSE/Technische Daten/Transportgewicht /474-xx @ 6\mod_1304586413879_6.doc @ 51363 @ 2 @ 1
7.9 Shipping Weight
Devices in the 2-fold Vario Chassis 1
CPU Unit / CON Unit
0.7 kg (1.5 lb)
Shipping Box
2.5 kg (5.5 lb)
Devices in the 2-fold Vario Chassis 2
CPU Unit / CON Unit
1.1 kg (2.4 lb)
Shipping Box
2.9 kg (6.4 lb)
Devices in the 4-fold Vario Chassis
CPU Unit / CON Unit
0.9 kg (2.0 lb)
Shipping Box
3.4 kg (7.5 lb)
Devices in the 6-fold Vario Chassis 6R
CPU Unit / CON Unit
1.9 kg (4.2 lb)
Shipping Box
5.1 kg (11.2 lb)
Devices in the 6-fold Vario Chassis 6BP / 6BPF
CPU Unit / CON Unit
2.5 kg (5.5 lb)
Shipping Box
3.5 kg (7.7 lb)
Devices in the 21-fold Vario Chassis
CPU Unit / CON Unit
10.0 kg (22.1 lb)
Shipping Box
14.5 kg (32.0 lb)
Pos: 125 /806-IHSE/Hilfe im Problemfall/UEB_Hilfe im Problemfall @ 5\mod_1278579113839_6.doc @ 42536 @ 1 @ 1
Page 51
Troubleshooting
2018-07-12 51
8 Troubleshooting
Pos: 126 /806-IHSE/Hilfe im Problemfall/Allgemeine Störung/474-xx @ 9\mod_1373964024756_6.doc @ 77427 @ 2 @ 1
8.1 General Failures
Diagnosis
Possible Reason
Measure
Config.txt parameter without function
Parameter not set or saved
Write parameter into Config.txt
file and save changes.
Start Command #CFG not set
Write start command #CFG into
first line of the Config.txt file.
Parameter written incorrectly
Check correct spelling and
capitalization.
Extender not restarted
Restart extender.
Pos: 127 /806-IHSE/Hilfe im Problemfall/Bildausfall/481-xx @ 9\mod_1367842260491_6.doc @ 71973 @ 2 @ 4
Page 52
Draco vario IP CPU KVM KVM Extender
52 2018-07-12
8.2 Blank Screen
CPU Module
Rear View
Rear View
Diagnosis
Possible Reason
Measure
LED 5, 6 off
Power supply
Check power supply units and
the connection to the power network.
LED 1, 3 flashing or LED 2, 4 off
Connection between CON Unit and CPU Unit
Check interconnect cables and
connections.
CPU Unit: LED 5, 6 violet
No video signal detected by source (computer, CPU)
Check DVI-D cable to CPU Download DDC information from
console monitors (see Chapter 6.1, Page 38). Reboot CPU if necessary.
CON Unit: LED 3 violet
No monitor detected
Check connection, length and
quality of the DVI-D cable to monitor, tighten cable thumbscrews.
No video signal detected from CPU Unit
Check connection, length and
quality of interconnect cables between the units.
Download DDC information from
console monitors (see Chapter 6.1, Page 38). Reboot CPU if necessary.
Pos: 128 /806-IHSE/Hilfe im Problemfall/Störung am USB-HID-Anschluss/481-xx @ 9\mod_1367843088075_6.doc @ 71993 @ 2 @ 4
Page 53
Troubleshooting
2018-07-12 53
8.3 USB-HID
CPU Module
Rear View
Rear View
Diagnosis
Possible Reason
Measure
Keyboard LEDs Shift and Scroll are blinking
Keyboard in Command Mode
Press <Esc> to leave Command
Mode.
CPU Unit: LED 5, 6 green or light blue/green flashing
No USB connection to CPU
Check connection of USB cable
to CPU; select another USB port if necessary.
Remove USB and power cable
and restart CPU. Connect power cable first.
CON Unit: LED 3 green or violet
Problems with USB connection
Check connection of USB cable
to USB-HID device.
Remove DVI and power cable
and restart CON Unit. Connect power cable first.
USB device without function
No USB-HID device
Connect USB-HID device.
USB-HID device is not supported
Contact dealer if necessary.
Pos: 129 /806-IHSE/Hilfe im Problemfall/Störung am seriellen Anschluss/474-xx @ 6\mod_1304586713332_6.doc @ 51418 @ 2 @ 1
Pos: 130 /806-IHSE/Hilfe im Problemfall/Störung am Analog-Audio-Anschluss/474-xx @ 6\mod_1304586773051_6.doc @ 51437 @ 2 @ 1
Pos: 131 /806-IHSE/Hilfe im Problemfall/Störung am Digital-Audio-Anschluss/474-xx @ 6\mod_1304586853379_6.doc @ 51456 @ 2 @ 1 Pos: 134 /806-IHSE/Hilfe im Problemfall/Störung am USB-2.0-Embedded-Anschluss/474-xx @ 7\mod_1331802913522_6.doc @ 58211 @ 2 @ 1
Page 54
Draco vario IP CPU KVM KVM Extender
54 2018-07-12
8.4 USB 2.0 embedded
CPU Module
Rear View
Rear View
Diagnosis
Possible Reason
Measure
CPU Unit: LED 8 off
No connection to CPU
Check connection USB cable to
CPU; select another USB port if necessary.
Remove USB and power cable
and restart CPU. Connect power cable first.
CPU Unit: LED 2, 4 off
No connection between CON Unit and CPU Unit
Check interconnect cable and
connectors.
CPU Unit: LED 8 flashing green
No USB 2.0 device
Connect USB 2.0 device.
USB 2.0 device is not supported
Check installation at the CPU,
also the necessary drivers.
New connection of the USB 2.0
device.
Contact dealer if necessary.
Page 55
Troubleshooting
2018-07-12 55
8.5 Compute Module
CPU Module
Rear View
Rear View
Diagnosis
Possible Reason
Measure
CPU Unit: LED 7 red
Kernel not active
Check TCP/IP network cable to
CPU Unit;
Repower IP CPU Unit
CPU Unit: LED 7 violet
Application not active
Check application on compute
module
Repower IP CPU Unit
CPU Unit: LED 10 flashing or off
TCP/IP network connection failure
Check connected network
devices (e.g. network switch)
Check TCP/IP network cable
connection
Page 56
Draco vario IP CPU KVM KVM Extender
56 2018-07-12
9 Technical Support
Prior to contacting support please ensure you have read this manual, and then installed and set-up your KVM Extender as recommended.
9.1 Support Checklist
To efficiently handle your request it is necessary that you complete a support request checklist (Download). Please ensure that you have the following information available before you call:
Company, name, phone number and email  Type and serial number of the device (see bottom of device)  Date and number of sales receipt, name of dealer if necessary  Issue date of the existing manual  Nature, circumstances and duration of the problem  Components included in the system (such as graphic source/CPU,
OS, graphic card, monitor, USB-HID/USB 2.0 devices, interconnect cable) including manufacturer and model number
Results from any testing you have done
9.2 Shipping Checklist
1. To return your device, contact your dealer to obtain a RMA number (Return-Material-Authorization).
2. Package your devices carefully, preferably using the original box. Add all pieces which you received originally.
3. Note your RMA number visibly on your shipment.
Devices that are sent in without a RMA number cannot be accepted. The shipment will be sent back without being opened, postage unpaid.
Pos: 138 /806-IHSE/Zertifikate/UEB_Zertifikate @ 5\mod_1278579534933_6.doc @ 42668 @ 1 @ 1
Page 57
Certificates
2018-07-12 57
10 Certificates
Pos: 139 /806-IHSE/Zertifikate/ATB_Europäische Konformitätserklärung @ 5\mod_1278579640901_6.doc @ 42686 @ 2 @ 1
10.1 CE Declaration Of Conformity
The products listed below in the form as delivered comply with the provisions of the following European Directives:
2014/30/EU Council Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility
2014/35/EU Council Directive on the harmonization of the laws of the
Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits
CE Marking Product list: 488 Series
The products comply with the following harmonized standards for Information Technology Equipment:
EN 55032:2012  EN 55024:2010 + A1:2015  EN 61000-3-2:2014  EN 61000-3-3:2013  EN 61000-6-2:2005  EN 60950-1:2006/A2:2013
Manufacturer: IHSE GmbH
Maybachstrasse 11 88094 Oberteuringen Deutschland
Oberteuringen, March 1st, 2017 The Management
Page 58
Draco vario IP CPU KVM KVM Extender
58 2018-07-12
Use in a Domestic Environment
This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures.
This declaration certifies the conformity to the specified directives but contains no assurance of properties. The safety instructions and installation guidelines noted in this manual shall be considered in detail. Compliance with the specifications for cable lengths and types is mandatory.
10.2 North American Regulatory Compliance
This equipment has been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Shielded cables must be used with this equipment to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances.
All power supplies are certified to the relevant major international safety standards.
Pos: 140 /806-IHSE/Zertifikate/481-xx_Produktsicherheit @ 9\mod_1367843931928_6.doc @ 72014 @ 2 @ 1
Page 59
Certificates
2018-07-12 59
10.3 Product Safety
The following devices comply with defined standards concerning product safety due to construction and design:
474-BODY2N 474-BODY6R 474-BODY21/4U
The product safety of the devices is proven by the compliance to the following standards:
IEC 60950-1/A1:2010  EN 60950-1/A12:2011/A1:2010/A11:2009  UL 60950-1-2007  CAN/CSA-C22.2 60950-1-07
The compliance is verified and confirmed by TÜV Süd, Germany.
Pos: 141 /806-IHSE/Zertifikate/ATB_WEEE @ 5\mod_1278579673292_6.doc @ 42704 @ 2 @ 1
10.4 WEEE
The manufacturer complies with the EU Directive 2012/19/EU on the prevention of waste electrical and electronic equipment (WEEE).
The device labels carry a respective marking.
Pos: 142 /806-IHSE/Zertifikate/ATB_RoHS @ 5\mod_1278579714214_6.doc @ 42722 @ 2 @ 1
10.5 RoHS/RoHS 2
This device complies with the Directive 2011/65/EU of the European Parliament and of the council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2, RoHS II).
The device labels carry a respective marking.
Pos: 143 /806-IHSE/Glossar/ATB_Glossar @ 5\mod_1278576825433_6.doc @ 41890 @ 1 @ 1
Page 60
Draco vario IP CPU KVM KVM Extender
60 2018-07-12
11 Glossary
The following terms are commonly used in this guide or in video and KVM technology:
Term
Explanation
AES/EBU
Digital audio standard that is officially known as AES3 and that is used for carrying digital audio signals between devices.
Cat X
Any Cat 5e (Cat 6, Cat 7) cable
CGA
Color Graphics Adapter (CGA) is an old analog graphic standard with up to 16 displayable colors and a maximum resolution of 640x400 pixels.
Component Video
Component Video (YPbPr) is a high-quality video standard that consists of three independently and separately transmittable video signals, the luminance signal and two color difference signals.
Composite Video
Composite Video is also called CVBS and it is part of the PAL TV standard.
CON Unit
Component of a KVM Extender or Media Extender to connect to the console (monitor(s), keyboard and mouse; optionally also with USB 2.0 devices)
Console
Keyboard, mouse and monitor
CPU Unit
Component of a KVM Extender or Media Extender to connect to a source (computer, CPU)
CVBS
The analog color video baseband signal (CVBS) is also called Composite Video and it is part of the PAL TV standard.
DDC
Display Data Channel (DDC) is a serial communication interface between monitor and source (computer, CPU). It allows a data exchange via monitor cable and an automatic installation and configuration of a monitor driver by the operating system.
DisplayPort
A VESA standardised interface for an all-digital transmission of audio and video data. It is differentiated between the DisplayPort standards 1.1 and 1.2. The signals have LVDS level.
Dual Access
A system to operate a source (computer, CPU) from two consoles
Page 61
Glossary
2018-07-12 61
Term
Explanation
Dual Link
A DVI-D interface for resolutions up to 2560x2048 by signal transmission of up to 330 MPixel/s (24-bit)
Dual-Head
A system with two video connections
DVI
Digital video standard, introduced by the Digital Display Working Group (http://www.ddwg.org). Single Link and Dual Link standard are distinguished. The signals have TMDS level.
DVI-I
A combined signal (digital and analog) that allows running a VGA monitor at a DVI-I port – in contrast to DVI-D (see DVI).
EGA
The Enhanced Graphics Adapter (EGA) is an old analog graphic standard, introduced by IBM in 1984. A D-Sub 9 connector is used for connection.
Fiber
Single-mode or multi-mode fiber cables
HDMI
An interface for an all-digital transmission of audio and video data. It is differentiated between the HDMI standards 1.0 to 1.4a.
The signals have TMDS level.
KVM
Keyboard, video and mouse
Mini-XLR
Industrial standard for electrical plug connections (3 pole) for the transmission of digital audio and control signals
Multi-mode
62.5µ multi-mode fiber cable or 50µ multi-mode fiber cable
OSD
The On-Screen-Display is used to display information or to operate a device.
Quad-Head
A system with four video connections
RCA (Cinch)
A non-standard plug connection for transmission of electrical audio and video signals, especially with coaxial cables
S/PDIF
A digital audio interconnect that is used in consumer audio equipment over relatively short distances.
SFP
SFPs (Small Form Factor Pluggable) are pluggable interface modules for Gigabit connections. SFP modules are available for Cat X and fiber interconnect cables.
Page 62
Draco vario IP CPU KVM KVM Extender
62 2018-07-12
Term
Explanation
Single Link
A DVI-D interface for resolutions up to 1920x1200 by signal transmission of up to 165 MPixel/s (24-bit).
Alternative frequencies are Full HD (1080p), 2K HD (2048x1080) and 2048x1152.
Single-Head
A system with one video connection
Single-mode
9µ single-mode fiber cable
S-Video (Y/C)
S-Video (Y/C) is a video format transmitting luminance and chrominance signals separately. Thereby it has a higher quality standard than CVBS.
TOSLINK
Standardized fiber connection system for digital transmission of audio signals (F05 plug connection)
Triple-Head
A system with three video connections
USB-HID
USB-HID devices (Human Interface Device) allow for data input.
There is no need for a special driver during installation; "New USB-HID device found" is reported.
Typical HID devices include keyboards, mice, graphics tablets and touch screens. Storage, video and audio devices are not HID.
VGA
Video Graphics Array (VGA) is a computer graphics standard with a typical resolution of 640x480 pixels and up to 262,144 colors. It can be seen as a follower of the graphics standards MDA, CGA and EGA.
=== Ende der Liste für Textmarke Inhalt ===
Loading...